• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
TB6640FTG
TB6640FTG

Practical Methods for Verifying Removal of Trojan Stable Operating
Practical Methods for Verifying Removal of Trojan Stable Operating

NOVA Family of Products
NOVA Family of Products

... source for operation. A fully charged battery and trip-andclose capacitors provide interrupter operation upon loss of control power. This feature provides dead-line operation capability–a requirement for many SCADA applications. ...
SHAFT GROUNDING ENGINEERING SPECIFICATION FOR AC
SHAFT GROUNDING ENGINEERING SPECIFICATION FOR AC

TraceNet TCM2 Installation Guide
TraceNet TCM2 Installation Guide

... A wide variety of TraceNet TCM2 system configurations are possible. The TCM2 control panels are designed to operate in ambients ranging from -40°F (-40°C) to 104°F (40°C) and higher. TraceNet TCM2 heat trace control and monitoring systems have been approved/certified for installation and operation i ...
Ampacity - garyklinka.com
Ampacity - garyklinka.com

... motors require GFCI protection under the following conditions: a. Connected to single phase circuit b. Cord-and-plug or direct connection c. Regardless of location d. all of the above -------------------------------------------------------------------------------------------------------------------- ...
PUMP TECHNICAL SERVICES/JUNG PUMPEN US EX
PUMP TECHNICAL SERVICES/JUNG PUMPEN US EX

ISO Rules Part 500 Facilities Division 502 Technical Requirements
ISO Rules Part 500 Facilities Division 502 Technical Requirements

... 12(1) A current transformer used in a protection system must be either magnetic or optical, and must not be the limiting element in the transmission facility’s rating. (2) The maximum available current transformer ratio must be sized for the ultimate fault level of the facility as set out in the fun ...
FIB Circuit Edit and Debug
FIB Circuit Edit and Debug

... to get functional prototypes samples in customer and internal development groups hands. FIB circuit edit can enable you to accelerate your product development cycle. FIB edits can be done quickly and easily, at a small fraction of the cost of a new lot of wafers in a fab. Circuit edits are often per ...
BUM 62 T - Baumüller Services
BUM 62 T - Baumüller Services

Al-Balqa` Applied University Faculty of Engineering Technology
Al-Balqa` Applied University Faculty of Engineering Technology

Calculation and Analysis of Transformer Inrush Current Based on
Calculation and Analysis of Transformer Inrush Current Based on

2 SMART Transmitter Power Supply SAFETY MANUAL SIL
2 SMART Transmitter Power Supply SAFETY MANUAL SIL

Evaluates:  MAX9940 MAX9940 Evaluation Kit General Description Features
Evaluates: MAX9940 MAX9940 Evaluation Kit General Description Features

... Enables the MAX9940 using the MAXQ2000’s GPIO pin, which is used for power saving. Power is only applied when the START pushbutton (SW2) is pressed. Power is disabled when the MAXQ2000 is done communicating with the DS2413. Before changing shunt positions, press the STOP pushbutton (SW3). Note: The ...
PSCAD Essential Tutorials
PSCAD Essential Tutorials

AM1600 Service Information
AM1600 Service Information

Short-Circuit Withstand Capability of Power Transformers
Short-Circuit Withstand Capability of Power Transformers

Relay Boards
Relay Boards

Gas-insulated switchgear type series 8DN8
Gas-insulated switchgear type series 8DN8

1C.4.1—Harmonic Distortion
1C.4.1—Harmonic Distortion

... Some customers may want rules-of-thumb to help keep their harmonic distortion under control without formal analysis. PacifiCorp suggests that harmonic producing devices used by these customers be limited or filtered at the individual device or equipment level. PacifiCorp’s recommended maximum indivi ...
Statistical Modeling of Leakage in Nano-CMOS Circuits - Mos-AK
Statistical Modeling of Leakage in Nano-CMOS Circuits - Mos-AK

DS2731 Cache-Memory Battery-Backup Management IC General Description Features
DS2731 Cache-Memory Battery-Backup Management IC General Description Features

... Supply-current specification is only for current drain of the IC and does not include cell-charge current, load-supply current, or any external resistor bias currents. The only exception is ISLEEP, which does account for complete current drain of the lithium cell during low-battery conditions. Below ...
Why is a transformer needed?
Why is a transformer needed?

... the ambient operating temperature to an appropriate power supply design to avoid overloading the power supply. Second, the purchaser of the power supply must pay attention to the differences in operating temperature ratings so as to make an intelligent buy decision, as the performance differences be ...
Enhanced SWEC Products and Services for Electrical
Enhanced SWEC Products and Services for Electrical

... Switchboard/ Switchgear /MCC/ Vacuum Circuit Breaker (VCB)Vacuum Contactor Unit (VCU)/Busbar) Rename as High Voltage Switchboard / Switchgear / Vacuum Circuit Breaker (VCB) / Vacuum Contactor Unit (VCU) / Contactor / Busbar ...
MV/LV transformer substations: theory and examples of short
MV/LV transformer substations: theory and examples of short

< 1 ... 74 75 76 77 78 79 80 81 82 ... 353 >

Earthing system

In electricity supply systems, an earthing system or grounding system is circuitry which connects parts of the electric circuit with the ground, thus defining the electric potential of the conductors relative to the Earth's conductive surface. The choice of earthing system can affect the safety and electromagnetic compatibility of the power supply. In particular, it affects the magnitude and distribution of short circuit currents through the system, and the effects it creates on equipment and people in the proximity of the circuit. If a fault within an electrical device connects a live supply conductor to an exposed conductive surface, anyone touching it while electrically connected to the earth will complete a circuit back to the earthed supply conductor and receive an electric shock.A protective earth (PE), known as an equipment grounding conductor in the US National Electrical Code, avoids this hazard by keeping the exposed conductive surfaces of a device at earth potential. To avoid possible voltage drop no current is allowed to flow in this conductor under normal circumstances. In the event of a fault, currents will flow that should trip or blow the fuse or circuit breaker protecting the circuit. A high impedance line-to-ground fault insufficient to trip the overcurrent protection may still trip a residual-current device (ground fault circuit interrupter or GFCI in North America) if one is present. This disconnection in the event of a dangerous condition before someone receives a shock, is a fundamental tenet of modern wiring practice and in many documents is referred to as automatic disconnection of supply (ADS). The alternative is defence in depth, where multiple independent failures must occur to expose a dangerous condition - reinforced or double insulation come into this latter category.In contrast, a functional earth connection serves a purpose other than shock protection, and may normally carry current. The most important example of a functional earth is the neutral in an electrical supply system. It is a current-carrying conductor connected to earth, often, but not always, at only one point to avoid flow of currents through the earth. The NEC calls it a groundED supply conductor to distinguish it from the equipment groundING conductor. Other examples of devices that use functional earth connections include surge suppressors and electromagnetic interference filters, certain antennas and measurement instruments.Regulations for earthing system vary considerably among countries and among different parts of electric systems. Most low voltage systems connect one supply conductor to the earth (ground).People use an earthing system mainly for these applications: To protect a structure from lightning strike, directing the lightning through the earthing system and into the ground rod rather than passing through the structure. Part of the safety system of mains electricity, preventing problems associated with floating ground and sky voltage. The most common ground plane for large monopole antenna and some other kinds of radio antenna.Other, less common applications of earthing systems include: single-wire earth return. part of a system that powers small devices from sky voltage. one at each end of a ground dipole ELF antenna.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report