• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
MV Prot Relay 7SJ61/62 - Siemens Industry, Inc.
MV Prot Relay 7SJ61/62 - Siemens Industry, Inc.

Managing Subthreshold Leakage in Charge
Managing Subthreshold Leakage in Charge

RF2472 2.4GHz LOW NOISE AMPLIFIER WITH ENABLE Features
RF2472 2.4GHz LOW NOISE AMPLIFIER WITH ENABLE Features

... The RF2472 is a low-noise amplifier with internal bias circuitry. It is DC-coupled on the input and output; therefore, it can be used to arbitrarily low frequency. It has useful gain to above 6GHz. Its design is optimized for use at 2.4GHz. Because of the high-frequency gain, the designer must take ...
Additional Installation, Operating and Maintenance Instructions
Additional Installation, Operating and Maintenance Instructions

Power and Protection for Modern Tetrodes
Power and Protection for Modern Tetrodes

... This is a very high-gain feedback loop, so it requires stabilization over a wide range of frequencies. An ordinary internally compensated op-amp is not suitable – in fact it will oscillate. The simple trick, courtesy of G4JZQ, is to use an uncompensated op-amp such as the 748 with heavy external com ...
Surge Arrester Application on Mv-Capacitor Banks to
Surge Arrester Application on Mv-Capacitor Banks to

... operations in MV networks, due to its associated transients. During the opening operation the transient recovery voltage (TRV) across the circuit breaker can rise to very high values and that can initiate breaker restrikes which in turn generate even higher overvoltages. Consequently, any restrike i ...
Drive Circuits
Drive Circuits

... • Signal processing circuits which generate the logic control signals not considered part of the drive circuit • Drive circuit amplifies control signals to levels required to drive power switch • Drive circuit has significant power capabilities compared to logic level signal processing circuits ...
S270-15-2
S270-15-2

... confine outages to smaller sections of line. The sectionalizer does not interrupt fault current but can be closed into a faulted line. It opens during the open interval of the backup device. For this reason, it must always be used in series with a fault-interrupting, backup protective reclosing devi ...
Bipolar Transistor Epilayer Design Using the MAIDS Mixed-Level Simulator
Bipolar Transistor Epilayer Design Using the MAIDS Mixed-Level Simulator

... The program structure has been optimized for speed during transient and harmonic balance simulations by using the previous solution as a starting guess. This approach is very robust for small voltage steps; when the voltage steps become too large, intermediate voltage steps are used. The circuit sim ...
Instruction Manual:PSD-10 Electrosurgical Unit
Instruction Manual:PSD-10 Electrosurgical Unit

Reset Circuit for the TMS320C6000 DSP
Reset Circuit for the TMS320C6000 DSP

pH Circuit DataSheet 5.0
pH Circuit DataSheet 5.0

... your reading request the pH Circuit will use a default temperature of 25 C°. See page 7 for more information. ...
a CMOS 3 V/5 V, Wide Bandwidth Quad 2:1 Mux ADG774
a CMOS 3 V/5 V, Wide Bandwidth Quad 2:1 Mux ADG774

... suitable for switching USB 1.1 data signals and fast Ethernet signals. The on resistance profile is very flat over the full analog input range ensuring excellent linearity and low distortion when switching audio signals. Fast switching speed, coupled with high signal bandwidth, also makes the parts ...
lecture1423723226
lecture1423723226

... Lenz‟s law, opposes the first flux. Use the right-hand rule to find the natural current direction corresponding to this second flux [see Fig. 14-7(b)]. Now place a dot at the terminal of the second winding where the natural current leaves the winding. This terminal is positive simultaneously with th ...
Understanding Power Impedance Supply for Optimum
Understanding Power Impedance Supply for Optimum

... ideal characteristics. In power supply design, the most important parasitics are the capacitors’ Equivalent Series Resistance (ESR) and Equivalent Series Inductance (ESL). Even these parasitic elements are not constant with time, temperature or frequency. At a frequency of 100 Hz, the ESR of the cap ...
GF2211111118
GF2211111118

... period of time, ranging from a few microseconds to 1sec. The study and understanding of this phenomenon is of extreme importance because during this time period, the system suffers greatest stress from excessive over-currents or voltages which if severe, can cause extensive damage[3,4,5]. Switching ...
Guide to International Travel with Electrical Appliances
Guide to International Travel with Electrical Appliances

... transformers or dual-voltage appliances. Please refer to the Voltage Chart in this brochure for a detailed list of the most commonly used adapter types throughout the world. Lewis N. Clark offers three types of adapter plugs: (Note to Canadian Consumers: Product offerings may be slightly different i ...
NERC Synchronizing Islands
NERC Synchronizing Islands

Protection of RS-232 Serial Connections
Protection of RS-232 Serial Connections

... All computer equipment is equipped with three wire grounding type AC power connectors. Many types of equipment, such as lamps, have only two wire type plugs since two wires are all that is necessary to deliver AC power. The third wire is a safety ground wire which is connected to any exposed metal p ...
Document
Document

Fuse Selection Guide
Fuse Selection Guide

Power Distribution Systems
Power Distribution Systems

February 26, 2013 MEMORANDUM TO: Patrick Hiland, Director Division
February 26, 2013 MEMORANDUM TO: Patrick Hiland, Director Division

... Licensees for the current operating plants stated that Class 1E buses are not designed to detect and automatically respond to a single-phase open circuit condition or high impedance ground fault condition on a credited offsite power circuit or other power sources. Specifically, the licensees stated ...
4. Genie Breaker Panel Theory
4. Genie Breaker Panel Theory

CT-8000 S3.indd
CT-8000 S3.indd

... be recalled and printed on the unit's built-in 4.5" wide thermal printer. Test records can also be transferred to a USB Flash drive or exported to a PC via the USB port or Bluetooth (optional) with the included Windows-based software. Up to 100 circuit breaker test plans can be stored in the CT-8000 ...
< 1 ... 77 78 79 80 81 82 83 84 85 ... 353 >

Earthing system

In electricity supply systems, an earthing system or grounding system is circuitry which connects parts of the electric circuit with the ground, thus defining the electric potential of the conductors relative to the Earth's conductive surface. The choice of earthing system can affect the safety and electromagnetic compatibility of the power supply. In particular, it affects the magnitude and distribution of short circuit currents through the system, and the effects it creates on equipment and people in the proximity of the circuit. If a fault within an electrical device connects a live supply conductor to an exposed conductive surface, anyone touching it while electrically connected to the earth will complete a circuit back to the earthed supply conductor and receive an electric shock.A protective earth (PE), known as an equipment grounding conductor in the US National Electrical Code, avoids this hazard by keeping the exposed conductive surfaces of a device at earth potential. To avoid possible voltage drop no current is allowed to flow in this conductor under normal circumstances. In the event of a fault, currents will flow that should trip or blow the fuse or circuit breaker protecting the circuit. A high impedance line-to-ground fault insufficient to trip the overcurrent protection may still trip a residual-current device (ground fault circuit interrupter or GFCI in North America) if one is present. This disconnection in the event of a dangerous condition before someone receives a shock, is a fundamental tenet of modern wiring practice and in many documents is referred to as automatic disconnection of supply (ADS). The alternative is defence in depth, where multiple independent failures must occur to expose a dangerous condition - reinforced or double insulation come into this latter category.In contrast, a functional earth connection serves a purpose other than shock protection, and may normally carry current. The most important example of a functional earth is the neutral in an electrical supply system. It is a current-carrying conductor connected to earth, often, but not always, at only one point to avoid flow of currents through the earth. The NEC calls it a groundED supply conductor to distinguish it from the equipment groundING conductor. Other examples of devices that use functional earth connections include surge suppressors and electromagnetic interference filters, certain antennas and measurement instruments.Regulations for earthing system vary considerably among countries and among different parts of electric systems. Most low voltage systems connect one supply conductor to the earth (ground).People use an earthing system mainly for these applications: To protect a structure from lightning strike, directing the lightning through the earthing system and into the ground rod rather than passing through the structure. Part of the safety system of mains electricity, preventing problems associated with floating ground and sky voltage. The most common ground plane for large monopole antenna and some other kinds of radio antenna.Other, less common applications of earthing systems include: single-wire earth return. part of a system that powers small devices from sky voltage. one at each end of a ground dipole ELF antenna.