• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
AVOP-ELEKTRO-SKA-010
AVOP-ELEKTRO-SKA-010

... Residual current device is an electrical device used for increased protection against injury caused by an electric current. It can‘t be used for basic protection – by automatic disconnection. Working wires are conducted through RCD, protective conductor mustn't be conducted through this device. It ...
DFB Mains supply considerations
DFB Mains supply considerations

Difference between Bonding, Grounding and
Difference between Bonding, Grounding and

4 Electricity - Home Distribution
4 Electricity - Home Distribution

... EARTH ...
rg-15 : implementing resistance grounding on solidly
rg-15 : implementing resistance grounding on solidly

Sample Paper Two partitioned (1)
Sample Paper Two partitioned (1)

... 27) The metallic pipe of a water utility supply shall not be used as an earth electrode. Other metallic water supply pipe work may be used as an earth electrode if it has been considered for such a use, and a) it is adequately buried in the ground b) precautions are taken against its removal c) is p ...
Chapter 20jeopardy
Chapter 20jeopardy

... Electricity ...
Earthing system
Earthing system

AS 90941 Student 3 Parallel circuit is a circuit where 2 or more path
AS 90941 Student 3 Parallel circuit is a circuit where 2 or more path

... Parallel circuit is a circuit where 2 or more path ways for electrons to pass through and go to the power user and all the power user gets all voltage from the power source whereas in a series circuit there is only one path way for the electrons to go through and if there is two or more power users ...
Session 20 – Earthing/Grounding Regulations
Session 20 – Earthing/Grounding Regulations

Electrical Safety -- and its implications for designing products
Electrical Safety -- and its implications for designing products

technical report of supply installation
technical report of supply installation

... Type of earthing arrangement is TNS: Yes Generator star point(s) / neutral point earthed: Yes All outgoing circuits are provided with circuit protective conductors: Yes Supplementary equipotential bonding provided for all extraneous parts: Yes Earth electrode resistance value __________ ohm(s) Earth ...
Motion Sensing Light Teardown
Motion Sensing Light Teardown

... Neutral to lights ...
Dia 1 - XAMK Moodle
Dia 1 - XAMK Moodle

An IEC Point of View on Grounding Systems of Outdoor
An IEC Point of View on Grounding Systems of Outdoor

... Not required, so far, by IEC standards because of the risk of repetitive shock to persons due to a persistent fault. Professional Engineers must decide on an ...
Electrical Engineering 1
Electrical Engineering 1

Testing of Low Voltage Installations
Testing of Low Voltage Installations

... • TT - when l.v. supply is given directly by the supply company • TN-S - allowed only when the supply transformer is owned by the consumer • Equipotential Bonding - to create an equipotential zone within reach, and all equipotential zones should be bonded to each other ...
Electricity
Electricity

... earth, any fault current is provided with low impedance path to earth I.e. one with little resistance so that fault current will operate protective devices and cut off the supply by breaking the circuit  If all exposed metalwork is properly bonded to earth, it cannot be made live by a fault and the ...
EVSTF09-32-TF2-04
EVSTF09-32-TF2-04

Understanding the Basics of Electrical Systems
Understanding the Basics of Electrical Systems

Earth Leakage Circuit Breaker (ELCB)
Earth Leakage Circuit Breaker (ELCB)

... ELCB sense coil with enough voltage to cause it to trip).  If the installation’s earth rod is placed close to the earth rod of a neighboring building, a high earth leakage current in the other building can raise the local ground potential and cause a voltage difference across the two earths, again ...
10EE36-Electric Power Generation(EPG) Unit 7 lecture
10EE36-Electric Power Generation(EPG) Unit 7 lecture

Earthing Transformer
Earthing Transformer

Accademia della Luce - educazione alle tecniche della luce
Accademia della Luce - educazione alle tecniche della luce

... the introduction of dangerous electrical potentials caused by failures in other equipments connected to the system. With regard to the latter, it is important to remember that an "improper" earthing system, with the consequent creation of extraneous earth, can be generated by the screenings of the s ...
Lecture 13
Lecture 13

... are designed to sense the development of a dangerous situation and operate to cut off the electrical supply to that circuit before the danger reaches an unacceptable level. ...
< 1 ... 348 349 350 351 352 >

Earthing system

In electricity supply systems, an earthing system or grounding system is circuitry which connects parts of the electric circuit with the ground, thus defining the electric potential of the conductors relative to the Earth's conductive surface. The choice of earthing system can affect the safety and electromagnetic compatibility of the power supply. In particular, it affects the magnitude and distribution of short circuit currents through the system, and the effects it creates on equipment and people in the proximity of the circuit. If a fault within an electrical device connects a live supply conductor to an exposed conductive surface, anyone touching it while electrically connected to the earth will complete a circuit back to the earthed supply conductor and receive an electric shock.A protective earth (PE), known as an equipment grounding conductor in the US National Electrical Code, avoids this hazard by keeping the exposed conductive surfaces of a device at earth potential. To avoid possible voltage drop no current is allowed to flow in this conductor under normal circumstances. In the event of a fault, currents will flow that should trip or blow the fuse or circuit breaker protecting the circuit. A high impedance line-to-ground fault insufficient to trip the overcurrent protection may still trip a residual-current device (ground fault circuit interrupter or GFCI in North America) if one is present. This disconnection in the event of a dangerous condition before someone receives a shock, is a fundamental tenet of modern wiring practice and in many documents is referred to as automatic disconnection of supply (ADS). The alternative is defence in depth, where multiple independent failures must occur to expose a dangerous condition - reinforced or double insulation come into this latter category.In contrast, a functional earth connection serves a purpose other than shock protection, and may normally carry current. The most important example of a functional earth is the neutral in an electrical supply system. It is a current-carrying conductor connected to earth, often, but not always, at only one point to avoid flow of currents through the earth. The NEC calls it a groundED supply conductor to distinguish it from the equipment groundING conductor. Other examples of devices that use functional earth connections include surge suppressors and electromagnetic interference filters, certain antennas and measurement instruments.Regulations for earthing system vary considerably among countries and among different parts of electric systems. Most low voltage systems connect one supply conductor to the earth (ground).People use an earthing system mainly for these applications: To protect a structure from lightning strike, directing the lightning through the earthing system and into the ground rod rather than passing through the structure. Part of the safety system of mains electricity, preventing problems associated with floating ground and sky voltage. The most common ground plane for large monopole antenna and some other kinds of radio antenna.Other, less common applications of earthing systems include: single-wire earth return. part of a system that powers small devices from sky voltage. one at each end of a ground dipole ELF antenna.