* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download AVOP-ELEKTRO-SKA-010
Resistive opto-isolator wikipedia , lookup
Electrical substation wikipedia , lookup
Stepper motor wikipedia , lookup
War of the currents wikipedia , lookup
Aluminium-conductor steel-reinforced cable wikipedia , lookup
History of electromagnetic theory wikipedia , lookup
Voltage optimisation wikipedia , lookup
Electrification wikipedia , lookup
Power engineering wikipedia , lookup
Ground loop (electricity) wikipedia , lookup
Electric machine wikipedia , lookup
Current source wikipedia , lookup
Mercury-arc valve wikipedia , lookup
Buck converter wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Opto-isolator wikipedia , lookup
Stray voltage wikipedia , lookup
Transformer wikipedia , lookup
History of electric power transmission wikipedia , lookup
Surge protector wikipedia , lookup
Skin effect wikipedia , lookup
Overhead power line wikipedia , lookup
Two-port network wikipedia , lookup
Protective relay wikipedia , lookup
Portable appliance testing wikipedia , lookup
Ground (electricity) wikipedia , lookup
Transformer types wikipedia , lookup
Mains electricity wikipedia , lookup
Three-phase electric power wikipedia , lookup
Network analysis (electrical circuits) wikipedia , lookup
Electrical wiring in the United Kingdom wikipedia , lookup
Alternating current wikipedia , lookup
Tutorial: Mechanic - electrician Topic: Fundamentals of electrical engineering the 2nd. year, RCD Prepared by : Škarka Miloš Projekt Anglicky v odborných předmětech, CZ.1.07/1.3.09/04.0002 je spolufinancován Evropským sociálním fondem a státním rozpočtem České republiky. Residual current device is an electrical device used for increased protection against injury caused by an electric current. It can‘t be used for basic protection – by automatic disconnection. Working wires are conducted through RCD, protective conductor mustn't be conducted through this device. It is used in environments with higher danger of injuries caused by an electric current. It‘s main parameters are: Nominal current Residual (differential) current Selectivity In normal conditions the vector sum of currents in working conductors equals null. In the secondary winding of the transformer no voltage is induced. In case of a current leak from the phase conductor to the ground, the voltage emerges in the secondary transformer winding, the current gets through the coil of the electro magnet and a malfunction is quickly disconnected from the rest of the electric network. Test buttons For one-phase circuits For three-phase circuits (1) Input power terminals (2) Output load terminals (3) Reset button (4) Contacts (the second one is for relay) (5) Relay equipment (6) Differential transformer (7) Control valve (8) Test button (9) Test conductor (orange) RCD connection in TNC-S network One-phase appliance With null Without null RCDs in TT, IT network TT Network IT Network L1 L1 Principle of RCD Which conductors have to be conducted through RCD? What is a residual current? When do you have to use RCD? Draw the connection of RCD in TN network What do numbers in picture 1 connote? Picture 1 • • http://www.jtlelektro.cz www.wikipedia.cz