• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Instructor : Dr - eem.anadolu.edu.tr
Instructor : Dr - eem.anadolu.edu.tr

electrical fires
electrical fires

... probable death ...
Chapter 18 - Cloudfront.net
Chapter 18 - Cloudfront.net

GOOD GROUNDING PRACTICES
GOOD GROUNDING PRACTICES

There are occasions where changes may need to be
There are occasions where changes may need to be

Today`s PPT
Today`s PPT

... the circuit from question five and six from the parallel circuit work sheet.  Measure the voltage, resistance, and current in the circuit.  Compare the worksheet values to the simulations values and summarize your findings using academic vocabulary (measuring devices, voltage, resistance, current, ...
LAB#4 - SIUE
LAB#4 - SIUE

LCR and resonance
LCR and resonance

Power Supply IC for Low Power AC Adapters
Power Supply IC for Low Power AC Adapters

Circuits (Series and Parallel) notes
Circuits (Series and Parallel) notes

... - the total resistance is increased What happens to the current in a parallel circuit when more loads are added? - the amount of current is greater on the paths with the smaller resistances - adding resistors in parallel decreases the total resistance of the circuit How do combination circuits help ...
Kirchoff Loop Laws …
Kirchoff Loop Laws …

monitoring of 24 V DC load circuits
monitoring of 24 V DC load circuits

... But even this theoretically possible high output current is not the perfect solution for the problem – since in practice, ohmic resistances of the feed and return wires to and from the fault location often prevent this maximum current from flowing. Already at a loop impedance of only 0.4 Ohm (for a ...
Unit 1001 Safe working practices in construction
Unit 1001 Safe working practices in construction

... Dealing with electric shocks ● Always disconnect the power supply first before helping someone. ● Use a wooden object to knock someone free or push away the source of the shock ● Don’t touch the person until they are clear of the supply. ● Call an ambulance immediately. ● Check for response and brea ...
ANALYSIS OF GROUNDING PRACTICES IN UNIFORM LAYER
ANALYSIS OF GROUNDING PRACTICES IN UNIFORM LAYER

... grounding systems. The isolation is provided by transformer primary and secondary windings that are coupled only by magnetic means. Thus, the system boundary is defined by the lack o f a physical connection that is either metallic or through a significantly high impedance [1], ...
A NOVEL THREE-PHASE TO FIVE
A NOVEL THREE-PHASE TO FIVE

TR41.9.1-06-11-004- Proposed Revisions to TIA-968
TR41.9.1-06-11-004- Proposed Revisions to TIA-968

... applicable to all states of loop-start devices, should not be applied to the Tip Ground state of loop-start Central-Office-implemented telephones per TSB-31-C. Recommend revising this clause as shown below: 4.6.2.1 For analog one-port 2-wire terminal equipment with loop-start, ringdown, or inband si ...
Resistance - BYU Physics and Astronomy
Resistance - BYU Physics and Astronomy

... Now consider non-equilibrium situations where E  0 and V  0 in a conductor. A non-zero E-field inside a conductor drives a non-zero current density J, which requires a continous source of flowing electric charge (e.g. a battery or power supply). When the electric current in a conductor is constan ...
FTZ4.3E
FTZ4.3E

... The products listed in this document are designed to be used with ordinary electronic equipment or devices (such as audio visual equipment, office-automation equipment, communications devices, electrical appliances and electronic toys). Should you intend to use these products with equipment or devic ...
charging by - Mrs. Wiedeman
charging by - Mrs. Wiedeman

GROUNDING AND NOISE
GROUNDING AND NOISE

Bifurcated Arc Fault Detection and Power Distribution
Bifurcated Arc Fault Detection and Power Distribution

... for repair. Comparison of a manufacturer base line with the post flight wire maps may allow for detection of other structural degradation of the mechanical components in the UCAV. Wing loading, fuselage flex or sensor package movements can also be determined by post flight review of the ARCMAS data. ...
EET 162.01
EET 162.01

... COURSE DESCRIPTION: The definition of sinusoidal voltage and current waveforms and the analysis of AC circuits. The concept of frequency is studied and how it affects resistance, inductance, and capacitance. Topics in the course include reactance, impedance, admittance, resonance, filters, Bode plot ...
dk 100 200 b420 b - Europower Components Ltd
dk 100 200 b420 b - Europower Components Ltd

... The transducer shall be used in electric/electronic equipment with respect to applicable standards and safety requirements and in accordance with all the related systems and components manufacturer’ operating instructions. Caution, Risk of electrical shock ...
Designation of total impedance and vector
Designation of total impedance and vector

... Now vectors of currents and voltages in circuit will be plotted. Note that lengths of vectors depend from their values. We have formulas only with symbols. We don’t calculate numeric value of vectors lengths. We will start plotting vectors from lasts elements in circuit. These elements are inductivi ...
Basic Lab Equipment
Basic Lab Equipment

... Although an "ideal" voltmeter would act like an open circuit (no current through the meter) and an ideal ammeter would act like a short circuit (no voltage across the meter), the instruments actually available for these measurements cannot be perfect. This means that the multimeter may actually load ...
< 1 ... 281 282 283 284 285 286 287 288 289 ... 353 >

Earthing system

In electricity supply systems, an earthing system or grounding system is circuitry which connects parts of the electric circuit with the ground, thus defining the electric potential of the conductors relative to the Earth's conductive surface. The choice of earthing system can affect the safety and electromagnetic compatibility of the power supply. In particular, it affects the magnitude and distribution of short circuit currents through the system, and the effects it creates on equipment and people in the proximity of the circuit. If a fault within an electrical device connects a live supply conductor to an exposed conductive surface, anyone touching it while electrically connected to the earth will complete a circuit back to the earthed supply conductor and receive an electric shock.A protective earth (PE), known as an equipment grounding conductor in the US National Electrical Code, avoids this hazard by keeping the exposed conductive surfaces of a device at earth potential. To avoid possible voltage drop no current is allowed to flow in this conductor under normal circumstances. In the event of a fault, currents will flow that should trip or blow the fuse or circuit breaker protecting the circuit. A high impedance line-to-ground fault insufficient to trip the overcurrent protection may still trip a residual-current device (ground fault circuit interrupter or GFCI in North America) if one is present. This disconnection in the event of a dangerous condition before someone receives a shock, is a fundamental tenet of modern wiring practice and in many documents is referred to as automatic disconnection of supply (ADS). The alternative is defence in depth, where multiple independent failures must occur to expose a dangerous condition - reinforced or double insulation come into this latter category.In contrast, a functional earth connection serves a purpose other than shock protection, and may normally carry current. The most important example of a functional earth is the neutral in an electrical supply system. It is a current-carrying conductor connected to earth, often, but not always, at only one point to avoid flow of currents through the earth. The NEC calls it a groundED supply conductor to distinguish it from the equipment groundING conductor. Other examples of devices that use functional earth connections include surge suppressors and electromagnetic interference filters, certain antennas and measurement instruments.Regulations for earthing system vary considerably among countries and among different parts of electric systems. Most low voltage systems connect one supply conductor to the earth (ground).People use an earthing system mainly for these applications: To protect a structure from lightning strike, directing the lightning through the earthing system and into the ground rod rather than passing through the structure. Part of the safety system of mains electricity, preventing problems associated with floating ground and sky voltage. The most common ground plane for large monopole antenna and some other kinds of radio antenna.Other, less common applications of earthing systems include: single-wire earth return. part of a system that powers small devices from sky voltage. one at each end of a ground dipole ELF antenna.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report