• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Effects of Stray Capacitance to Ground in Three
Effects of Stray Capacitance to Ground in Three

IEEE Paper Template in A4 (V1)
IEEE Paper Template in A4 (V1)

... Each building should be protected from lightning and the electrical equipment shall not only be protected from the direct stroke of the lightning but also be protected from transferring surge intruded by the lightning stroke away from the equipment at the plant. In this paper the characteristics of ...
SMARTHOME™ 1-800-SMART-HOME 949-221
SMARTHOME™ 1-800-SMART-HOME 949-221

A high-voltage bipolar voltage-to-current converter (HVB-VIC)
A high-voltage bipolar voltage-to-current converter (HVB-VIC)

ESD0P4RFL
ESD0P4RFL

... For information on the types in question, please contact the nearest Infineon Technologies Office. Infineon Technologies components may be used in life-support devices or systems only with the express written approval of Infineon Technologies, if a failure of such components can reasonably be expect ...
EDS 08-0121 Supplies to HOT Sites and
EDS 08-0121 Supplies to HOT Sites and

... voltage sites (e.g. 132kV, 33kV etc.) that are HOT or owned by National Grid1. Supplies to these sites require special consideration to avoid the earth potential rise (EPR) during an earth fault being exported onto the HV or LV network and into a customer's premises where it could cause danger to li ...
power factor correction filters with static switching fre series
power factor correction filters with static switching fre series

service reminder
service reminder

Electricity
Electricity

... Scout must have a buddy: a friend, parent, guardian, brother, sister, or other relative—or better yet, another Scout working on the same badge—along with him attending the session. When the Scout meets with the counselor, he should bring any required projects. If these cannot be transported, he shou ...
electromagnetic induction
electromagnetic induction



ATE Quick Start Guide
ATE Quick Start Guide

... operating mode is indicated by LED mode indicators at the front panel (Figure 1). Operating mode crossover is automatic and may be monitored remotely by means of a flag signal, available at the rear programming connector. The power supply features “full range” output control by means of 10-turn, hig ...
Aalborg Universitet Fuel Cell Equivalent Electric Circuit Parameter Mapping
Aalborg Universitet Fuel Cell Equivalent Electric Circuit Parameter Mapping

... this paper, a simplified Randle’s EEC is utilized, where only one arc is included. This is done since the impedance response is rather simple for the fuel cell used in this work. A simpler EEC also reduces the fitting time, which is convenient for online diagnostic purposes. In order to get a suitab ...
ProSafe Isolation Transformer - Marlow
ProSafe Isolation Transformer - Marlow

New algorithms to improve the sensitivity of differential protection of
New algorithms to improve the sensitivity of differential protection of

Flat Transformers for Low Voltage, High Current, High Frequency
Flat Transformers for Low Voltage, High Current, High Frequency

... Due to the low probable number of primary turns, the current density of the transformer can be increased dramatically beyond the capability of any conventional designs. The advantage of this transformer has been well documented previously [1, 3, 4, 5, 6, 8], and will only be summarized here. The mai ...
Homage to James Clerk Maxwell - James Clerk Maxwell Foundation
Homage to James Clerk Maxwell - James Clerk Maxwell Foundation

... As one privileged to learn the fundamentals of electromagnetic theory at the feet of Nicholas Kemmer in the Old Tait Institute in Edinburgh during the1950's, it was inevitable that I should at an early stage acquire a deep admiration, indeed awe, in relation to the massive achievements of James Cler ...
WHY METALS CORRODE
WHY METALS CORRODE

... conversely, be the cause of corrosion. Whenever current leaves a metal to go into the ground the metal will be attacked: whenever the current comes onto a metal from the ground, the metal will be protected. Stray currents originating from DC power source can travel for miles over a system of pipelin ...
Testing the Efficiency of a Joule Thief LED Light Circuit J0915
Testing the Efficiency of a Joule Thief LED Light Circuit J0915

... bulb with 0.03 mA whereas the simple circuit could not light the LED. When converted to joules using the equation mA # V= Power, Joules, or mW, the power usage of the Joule Thief circuit was less than the power used by the simple circuit. The Joule Thief circuit used 28.19% less power than the simpl ...
IF 1670 Revision 1
IF 1670 Revision 1

... All gasket seals must be clean. Before opening, electrical power to the floodlight must be turned off. Keep tightly closed when in operation. ...
elite-616 installation
elite-616 installation

Power Quality Improvement by Shunt Active Performance Filters
Power Quality Improvement by Shunt Active Performance Filters

Circuit Symbols of Electronic Components
Circuit Symbols of Electronic Components

... Drawfile circuit symbols (29K) - for RISC OS (Acorn) computers. These high quality vector drawings are suitable for almost all documents on a RISC OS computer. All the symbols were originally drawn in this format. They print perfectly and can be enlarged without loss of quality. Sorry, this format i ...
Fault Identification and Islanding in DC Grid Connected PV System
Fault Identification and Islanding in DC Grid Connected PV System

... create large backed current and very high Earth-fault current. Without any sensor, these faults are identified, when the sign of the monitored primary grid current is changed [21]. 2) Bridging fault When low-resistance connection recognized between two points of different potential in string of modu ...
Safety First!
Safety First!

< 1 ... 144 145 146 147 148 149 150 151 152 ... 353 >

Earthing system

In electricity supply systems, an earthing system or grounding system is circuitry which connects parts of the electric circuit with the ground, thus defining the electric potential of the conductors relative to the Earth's conductive surface. The choice of earthing system can affect the safety and electromagnetic compatibility of the power supply. In particular, it affects the magnitude and distribution of short circuit currents through the system, and the effects it creates on equipment and people in the proximity of the circuit. If a fault within an electrical device connects a live supply conductor to an exposed conductive surface, anyone touching it while electrically connected to the earth will complete a circuit back to the earthed supply conductor and receive an electric shock.A protective earth (PE), known as an equipment grounding conductor in the US National Electrical Code, avoids this hazard by keeping the exposed conductive surfaces of a device at earth potential. To avoid possible voltage drop no current is allowed to flow in this conductor under normal circumstances. In the event of a fault, currents will flow that should trip or blow the fuse or circuit breaker protecting the circuit. A high impedance line-to-ground fault insufficient to trip the overcurrent protection may still trip a residual-current device (ground fault circuit interrupter or GFCI in North America) if one is present. This disconnection in the event of a dangerous condition before someone receives a shock, is a fundamental tenet of modern wiring practice and in many documents is referred to as automatic disconnection of supply (ADS). The alternative is defence in depth, where multiple independent failures must occur to expose a dangerous condition - reinforced or double insulation come into this latter category.In contrast, a functional earth connection serves a purpose other than shock protection, and may normally carry current. The most important example of a functional earth is the neutral in an electrical supply system. It is a current-carrying conductor connected to earth, often, but not always, at only one point to avoid flow of currents through the earth. The NEC calls it a groundED supply conductor to distinguish it from the equipment groundING conductor. Other examples of devices that use functional earth connections include surge suppressors and electromagnetic interference filters, certain antennas and measurement instruments.Regulations for earthing system vary considerably among countries and among different parts of electric systems. Most low voltage systems connect one supply conductor to the earth (ground).People use an earthing system mainly for these applications: To protect a structure from lightning strike, directing the lightning through the earthing system and into the ground rod rather than passing through the structure. Part of the safety system of mains electricity, preventing problems associated with floating ground and sky voltage. The most common ground plane for large monopole antenna and some other kinds of radio antenna.Other, less common applications of earthing systems include: single-wire earth return. part of a system that powers small devices from sky voltage. one at each end of a ground dipole ELF antenna.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report