• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
78M6612 Printed Circuit Board Layout Guidelines
78M6612 Printed Circuit Board Layout Guidelines

(b) a
(b) a

... that we have been introduced to the superposition principle and source transformation, it is possible to develop two more techniques that will greatly simplify the analysis of many linear circuits. ...
Document
Document

... A circuit breaker is an overcurrent protective device that does not need to be replaced each time the circuit current rating is exceeded. Circuit breakers may be thermally or magnetically operated. ...
Selective Coordination Overview of Short Circuit Selective
Selective Coordination Overview of Short Circuit Selective

... occurs. 6.5.2 Short Circuit Current. The maximum available short circuit current from both the utility source and the emergency energy source shall be evaluated for the ability to satisfy this coordination capability. ...
AAT4625 数据资料DataSheet下载
AAT4625 数据资料DataSheet下载

... affecting the operation of the AAT4625. For example, if an AAT4625 is used in a circuit that operates from a 5V power supply with poor step load response, turning on the load switch could cause the input power supply to drop below the AAT4625's under-voltage lockout threshold. This drop in voltage w ...
Go Picture These! - Lake Area Radio Klub
Go Picture These! - Lake Area Radio Klub

All About Electric Fields
All About Electric Fields

Problem B - Geneva Area City Schools
Problem B - Geneva Area City Schools

... 9. A wind turbine is built to service farmers in England. The turbine is connected to a generator, which can supply a rms current of 1.3 A on a 12 kΩ load. If the rms potential difference is 15.6 kV, find the maximum output emf provided by the wind turbine. Calculate the maximum ac current. How much ...
AC Generators with 2/3rd and 5/6th winding pitch 429.56 KB
AC Generators with 2/3rd and 5/6th winding pitch 429.56 KB

... It is important to understand the differences between neutral star point reference earthing and equipotential bonding. The latter applies no matter what the winding pitch or neutral configuration and is an electrical safety consideration. The former is an electrical system design function that may h ...
BE ON GUARD FOR EFFECTIVE TESTING
BE ON GUARD FOR EFFECTIVE TESTING

Toolkit 2 - Apprentice Training and Profiling
Toolkit 2 - Apprentice Training and Profiling

Shipboard Electrical Equipment
Shipboard Electrical Equipment

... The ship’s forward distribution switchboard is also used as the control switchboard. This switchboard has instruments and controls for the aft generators. These instruments and controls are necessary to parallel the generators to equalize the load. An automatic voltage regulator is mounted on each s ...
ELECTRIC CIRCUITS I
ELECTRIC CIRCUITS I

Earth Grounding Pamphlet - Defense Technical Information Center
Earth Grounding Pamphlet - Defense Technical Information Center

MS-5UD-3E - Fire
MS-5UD-3E - Fire

... detector rating. Additionally, both the MS-5UD-3 and MS10UD-7 are compatible with conventional input devices such as two- and four-wire smoke detectors, pull stations, waterflow devices, tamper switches, and other normally-open contact devices. Refer to the Fire•Lite Device Compatibility Document fo ...
OESC Code Rule 02-022 and Rule 02-028
OESC Code Rule 02-022 and Rule 02-028

... Existing Subrules (3)(a) and (b), are edited to eliminate using both “and” and “or” at the end of items in Subrule (3). Existing Subrule (3)(c)(iii) is deleted because it is redundant. Portable battery-operated equipment is exempted from the approval requirements based on the Product Safety Guidelin ...
English - Hotline Electric Fencing
English - Hotline Electric Fencing

... mains equivalent to that provided by the energizer. NOTE 1 Ancillary equipment that complies with the requirements relating to isolation between the fence circuit and the supply mains in Clauses 14, 16 and 29 of the standard for the electric fence energiser is considered to provide an adequate level ...
iew rev Book 93
iew rev Book 93

... starts with an Introduction chapter ...
Checking ground electrode impedance for commercial, industrial
Checking ground electrode impedance for commercial, industrial

the design and construction of an electrophoresis machine
the design and construction of an electrophoresis machine

P85271
P85271

... obstructions, special attention should be given to the location of the strobes so that their operating effect can be seen by all intended viewers, with the intensity, number, and type of strobes being sufficient to make sure that the intended viewer is alerted by proper illumination, regardless of t ...
2010 EMC Modeling of an Industrial Variable Speed Drive Wih an Adapted PEEC Method
2010 EMC Modeling of an Industrial Variable Speed Drive Wih an Adapted PEEC Method

... (i.e., extraction of equivalent circuit components thanks to integral approach) is known to be well adapted to model complex geometries with an important surrounded air region [1]–[4]. However, the classical PEEC method which is widely used at high frequencies (antennas, RF devices, etc.), would be ...
Optional Extra Credit Exercise
Optional Extra Credit Exercise

... problem correctly. Show your work. No credit will be given for answers not supported by your work. Test Questions 2, Which of the following is not true about the electric potential, V? a, V at a point is the electric potential energy per unit charge at that point. b, We are normally only interested ...
Lecture 14 Disadvantages of Transformers and Introduction to the
Lecture 14 Disadvantages of Transformers and Introduction to the

... makes for a two winding inductor--each separately wound and isolated electrically from each other except for the common magnetic core coupling . We now lose the common ground. Current no longer flows simultaneously in the two electrically isolated inductor windings due to the core coupling alone bec ...
Transformers and transmission
Transformers and transmission

... The electrician connects the house to the 240 VRMS supply using lines with a total resistance of 2.0 Ω. Some of the appliances in the house are turned on to test the new supply. Measurements reveal that, under these test conditions, the current flowing is 30 A. Calculate the power loss in the supply ...
< 1 ... 145 146 147 148 149 150 151 152 153 ... 353 >

Earthing system

In electricity supply systems, an earthing system or grounding system is circuitry which connects parts of the electric circuit with the ground, thus defining the electric potential of the conductors relative to the Earth's conductive surface. The choice of earthing system can affect the safety and electromagnetic compatibility of the power supply. In particular, it affects the magnitude and distribution of short circuit currents through the system, and the effects it creates on equipment and people in the proximity of the circuit. If a fault within an electrical device connects a live supply conductor to an exposed conductive surface, anyone touching it while electrically connected to the earth will complete a circuit back to the earthed supply conductor and receive an electric shock.A protective earth (PE), known as an equipment grounding conductor in the US National Electrical Code, avoids this hazard by keeping the exposed conductive surfaces of a device at earth potential. To avoid possible voltage drop no current is allowed to flow in this conductor under normal circumstances. In the event of a fault, currents will flow that should trip or blow the fuse or circuit breaker protecting the circuit. A high impedance line-to-ground fault insufficient to trip the overcurrent protection may still trip a residual-current device (ground fault circuit interrupter or GFCI in North America) if one is present. This disconnection in the event of a dangerous condition before someone receives a shock, is a fundamental tenet of modern wiring practice and in many documents is referred to as automatic disconnection of supply (ADS). The alternative is defence in depth, where multiple independent failures must occur to expose a dangerous condition - reinforced or double insulation come into this latter category.In contrast, a functional earth connection serves a purpose other than shock protection, and may normally carry current. The most important example of a functional earth is the neutral in an electrical supply system. It is a current-carrying conductor connected to earth, often, but not always, at only one point to avoid flow of currents through the earth. The NEC calls it a groundED supply conductor to distinguish it from the equipment groundING conductor. Other examples of devices that use functional earth connections include surge suppressors and electromagnetic interference filters, certain antennas and measurement instruments.Regulations for earthing system vary considerably among countries and among different parts of electric systems. Most low voltage systems connect one supply conductor to the earth (ground).People use an earthing system mainly for these applications: To protect a structure from lightning strike, directing the lightning through the earthing system and into the ground rod rather than passing through the structure. Part of the safety system of mains electricity, preventing problems associated with floating ground and sky voltage. The most common ground plane for large monopole antenna and some other kinds of radio antenna.Other, less common applications of earthing systems include: single-wire earth return. part of a system that powers small devices from sky voltage. one at each end of a ground dipole ELF antenna.