• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Electrical Safety Policy
Electrical Safety Policy

... In those cases where the exposed live parts are not deenergized, either because of increased or additional hazards or because of infeasibility due to equipment design or operational limitations, other safety-related work practices must be used to protect employees who may be exposed to the electrica ...
ppt
ppt

...  Need to ramp-down HV following a fast quench (t ~ 280s) ...
MehrdadMokhtariMFKE2013ABS
MehrdadMokhtariMFKE2013ABS

... Lightning arrester in a power system is categorized as a device, which operates in transient conditions. Therefore, the performance of the arrester must be analyzed in transient circumstances. Some particular considerations such as physical (grounding installation) and electrical (impulse current) a ...
Method for Static and Dynamic Resistance Measurements of HV
Method for Static and Dynamic Resistance Measurements of HV

... components are usually very low (10-1000 μΩ); nevertheless their increase above acceptable values may lead to serious problems, since operation of electrical equipment depends on the controlled flow of current within the design parameters of the given piece of equipment. ...
UEENEEG118A Maintain operation of electrical mining equipment
UEENEEG118A Maintain operation of electrical mining equipment

... equipment, gas or any other hazardous substance/material carries risk in deeming a person competent. Sources of evidence need to be ‘rich’ in nature to minimise error in judgment. Activities associated with normal every day work have a bearing on the decision as to how much and how detailed the data ...
0943p ERICO CRITEC in switchboard components
0943p ERICO CRITEC in switchboard components

How to set up a single phase input device from a three phase input
How to set up a single phase input device from a three phase input

answer
answer

... Name an appliance that uses resistance to ...
answer
answer

Wiring Main Circuit and Peripheral Devices
Wiring Main Circuit and Peripheral Devices

(no dtcs): check the fan control primary circuits
(no dtcs): check the fan control primary circuits

Winding Resistance Measurements Megger MTO210
Winding Resistance Measurements Megger MTO210

Applying Interrupting Rating: Circuit Breakers
Applying Interrupting Rating: Circuit Breakers

Datasheet - STMicroelectronics
Datasheet - STMicroelectronics

Circuits II Tut
Circuits II Tut

... and explain the relative brightness of the bulbs. A. Three students give predictions and explanations for the relative brightness of bulbs A, B, and C. Identify which students, if any, are reasoning correctly. For the ones not reasoning correctly, offer a response that would help them understand whe ...
Circuits II Tut
Circuits II Tut

... B. Four students give explanations for the relative brightness of bulbs in the circuit below. Identify which students, if any, are reasoning correctly. For the ones not reasoning correctly, offer a response that would help them understand where their thinking went astray. ...
Earth fault protection in isolated and compensated
Earth fault protection in isolated and compensated

... by Statkraft. The report consists of three main parts. The first part presents a problem description and theory, the second part presents possible solutions to the problem described, and simulations with one of the mentioned solutions. At the end, a conclusion is drawn. In the introductory chapters ...
TB67S105FTG Usage considerations
TB67S105FTG Usage considerations

... Use an appropriate power supply fuse for the power supply line to ensure that a large current does not continuously flow in the case of over-current and/or IC failure. The IC will fully break down when used under conditions that exceed its absolute maximum ratings, when the wiring is routed improper ...
DS507 Manual - Dyne Systems
DS507 Manual - Dyne Systems

A leakage Current Replica Keeper for Dynamic Circuits
A leakage Current Replica Keeper for Dynamic Circuits

RadioRA 2 Architectural RF GrafikTT Local Controls product specifications
RadioRA 2 Architectural RF GrafikTT Local Controls product specifications

AD5203设计的8串白光LED驱动方案
AD5203设计的8串白光LED驱动方案

HELICALLY FORMED FITTINGS
HELICALLY FORMED FITTINGS

... OPGW ...
392KB - NZQA
392KB - NZQA

... solve a circuit problem in a parallel circuit. ...
Three phase Rotation Conventions
Three phase Rotation Conventions

< 1 ... 141 142 143 144 145 146 147 148 149 ... 353 >

Earthing system

In electricity supply systems, an earthing system or grounding system is circuitry which connects parts of the electric circuit with the ground, thus defining the electric potential of the conductors relative to the Earth's conductive surface. The choice of earthing system can affect the safety and electromagnetic compatibility of the power supply. In particular, it affects the magnitude and distribution of short circuit currents through the system, and the effects it creates on equipment and people in the proximity of the circuit. If a fault within an electrical device connects a live supply conductor to an exposed conductive surface, anyone touching it while electrically connected to the earth will complete a circuit back to the earthed supply conductor and receive an electric shock.A protective earth (PE), known as an equipment grounding conductor in the US National Electrical Code, avoids this hazard by keeping the exposed conductive surfaces of a device at earth potential. To avoid possible voltage drop no current is allowed to flow in this conductor under normal circumstances. In the event of a fault, currents will flow that should trip or blow the fuse or circuit breaker protecting the circuit. A high impedance line-to-ground fault insufficient to trip the overcurrent protection may still trip a residual-current device (ground fault circuit interrupter or GFCI in North America) if one is present. This disconnection in the event of a dangerous condition before someone receives a shock, is a fundamental tenet of modern wiring practice and in many documents is referred to as automatic disconnection of supply (ADS). The alternative is defence in depth, where multiple independent failures must occur to expose a dangerous condition - reinforced or double insulation come into this latter category.In contrast, a functional earth connection serves a purpose other than shock protection, and may normally carry current. The most important example of a functional earth is the neutral in an electrical supply system. It is a current-carrying conductor connected to earth, often, but not always, at only one point to avoid flow of currents through the earth. The NEC calls it a groundED supply conductor to distinguish it from the equipment groundING conductor. Other examples of devices that use functional earth connections include surge suppressors and electromagnetic interference filters, certain antennas and measurement instruments.Regulations for earthing system vary considerably among countries and among different parts of electric systems. Most low voltage systems connect one supply conductor to the earth (ground).People use an earthing system mainly for these applications: To protect a structure from lightning strike, directing the lightning through the earthing system and into the ground rod rather than passing through the structure. Part of the safety system of mains electricity, preventing problems associated with floating ground and sky voltage. The most common ground plane for large monopole antenna and some other kinds of radio antenna.Other, less common applications of earthing systems include: single-wire earth return. part of a system that powers small devices from sky voltage. one at each end of a ground dipole ELF antenna.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report