• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
MAX16839 Evaluation Kit Evaluates: General Description Features
MAX16839 Evaluation Kit Evaluates: General Description Features

... The EV kit operates from a 5V to 40V rated power supply providing up to 300mA and the EV kit can withstand a 45V load-dump condition. The input supply is filtered by common-mode choke L1 and capacitor C1, while battery-reverse protection is provided by diode D1. The input supply chopper circuit is c ...
iCoupler® Isolation in RS-485 Applications Application Note (AN-727)
iCoupler® Isolation in RS-485 Applications Application Note (AN-727)

... system grounds connected to the bus and separated by hundreds or thousands of meters will be at the same potential. Because these grounds are unlikely to be at the same potential, current will flow between these points. This unintended current flow can damage or destroy components. ...
Siemens STEP 2000 Course
Siemens STEP 2000 Course

UNIT  - StudyGuide.PK
UNIT - StudyGuide.PK

... Outline The concepts of flux and flux linkage are introduced so that electromagnetic induction may be studied. Aspects of alternating current are also included. Online Resources. In this unit repeated use is made of Java Applets. These are usually well animated programmes. It has been found preferab ...
Electrical Measuring Instruments
Electrical Measuring Instruments

... were no ‘volts’ and no ‘amperes’, as these units of measurement didn’t exist until nearly thirty years after his death! And, of course, there was no ‘resistance’, as this was a word coined by Ohm himself, and its unit of measurement named in his honour only after his death. Experimental scientists, ...
Dimensioning of electrical installations  Calculation softwares examined
Dimensioning of electrical installations Calculation softwares examined

... requirements as regards humans and animals must be fulfilled in any situation. Electrical faults may also cause fire. This is why electrical installations must be planned and dimensioned correctly to ensure a safe installation for users. The installation should also be reliable and qualitative to gu ...
PS21767 - Powerex
PS21767 - Powerex

... of each input should be as short as possible. When using RC coupling circuit, make sure the input signal level meets the turn-on and turn-off threshold voltage. See application notes for details. 2) Internal HVIC provides high voltage level shifting allowing direct connection of all six driving sign ...
Faraday`s Law of Electromagnetic Induction
Faraday`s Law of Electromagnetic Induction

... This electromotive force acts as the driving force for the current induced in the closed circuit C, and Faraday’s law states that this emf results from any change in the magnetic flux linking that circuit. Notice that the mathematical expression (3) of Faraday’s law is a statement of an independent ...
EMI EMISSIONS
EMI EMISSIONS

... Electromagnetic Interference (EMI) noise is defined as an unwanted electrical signal that produces undesirable effects in a control system, such as communication errors, degraded equipment performance and malfunction or non-operation. References on the general principles of EMI are available, as wel ...
2012S
2012S

Earth Magnetic Field
Earth Magnetic Field

... 6. More details on the analysis: 6.a Determination of calibration constant: 6.a.1 Method 4.4 is recommended for the calibration. Take at least 20 points, covering as wide a range of deflection as possible. 6.a.2 Once you know de , every deflection and current measurement yields a measurement of the ...
Chapter 13
Chapter 13

... resonance in a series RLC circuit because they are equal in magnitude and 180° out of phase • In a parallel RLC circuit, the smaller reactance determines the net reactance of the circuit • In a parallel resonant circuit, the impedance is maximum at the resonant frequency • A parallel resonant circui ...
IEEE-NFPA Small Wire Report
IEEE-NFPA Small Wire Report

... of the conductors where the maximum possible I2t, instantaneous peak current, and voltage would be imposed on the conductor pertaining to the various systems. The four types of systems investigated are shown in Fig.4 through Fig. 7. The three phase bolted fault test configuration described previousl ...


... For warranty service or repair, the product must be properly packaged, and returned to Xytronix Research & Design, Inc. The purchaser shall prepay all charges for shipping to Xytronix Research & Design, Inc., and Xytronix Research & Design, Inc. will pay the shipping charges to return the product to ...
Wavenology EM Tutorial (Graphic Circuit Editor)
Wavenology EM Tutorial (Graphic Circuit Editor)

... 6. V probe with three resistors: graphic_circuit_demo\vProbe\vp01.wnt 7. Differential V probe with three resistors: graphic_circuit_demo\vProbe\vp02.wnt 8. I probe with three resistors: graphic_circuit_demo\IProbe\ip01.wnt 9. I probe with resistor, source and inductor: graphic_circuit_demo\IProbe\ip ...
3 Electric Currents from Magnetism
3 Electric Currents from Magnetism

(ii) Loading cycle test.
(ii) Loading cycle test.

... 2. Gap should be premises. 3. Nobody should go near the H.T. bushing when the test being conducted. 4. Ignore the first one or two readings, as the air between the electrodesmay not ionize. 5. The equipment must be grounded firmly. ...
II 777 HVR P2 B Installation Instructions
II 777 HVR P2 B Installation Instructions

... provide protection against short cycling and to allow adequate cool down time between motor starts. This timer is initiated when power is first applied to the unit. If no voltage fault conditions exists, the output relay will energize (the NO will close and the NC will open) as soon as RD1 timer exp ...
TRANSIENTS IN NO-LOAD CONDITION OF POWER
TRANSIENTS IN NO-LOAD CONDITION OF POWER

Reliable Protection for systems, generators and motors up to 1600 A
Reliable Protection for systems, generators and motors up to 1600 A

... Circuit-breakers NZM protect entire systems as well as cables and wiring on all levels, from the main distribution board right up to the loads. As the incoming circuit-breaker, the NZM will of course also provide secondary side overload protection for the transformer. A variant with modified short-c ...
Electricity - FLYPARSONS.org
Electricity - FLYPARSONS.org

transformers - BRUSH SEM sro
transformers - BRUSH SEM sro

Download T3200 Datasheet
Download T3200 Datasheet

... The instrument output has been adapted for connection of a megaohmmeter which indicates the actual insulation level, either by means of two instruments simultaneously indicating for both insulation systems (I and II), or by means of one instrument which can be connected to the two instrument outputs ...
THE EFFECT OF ELECTRIC FIELD ON
THE EFFECT OF ELECTRIC FIELD ON

How to achieve consistency with AD
How to achieve consistency with AD

... required just a short connection through a via. As there are likely to be occasions where more than one voltage level is required, then several power planes may be necessary or a single plane may be split into different voltage levels. ...
< 1 ... 140 141 142 143 144 145 146 147 148 ... 353 >

Earthing system

In electricity supply systems, an earthing system or grounding system is circuitry which connects parts of the electric circuit with the ground, thus defining the electric potential of the conductors relative to the Earth's conductive surface. The choice of earthing system can affect the safety and electromagnetic compatibility of the power supply. In particular, it affects the magnitude and distribution of short circuit currents through the system, and the effects it creates on equipment and people in the proximity of the circuit. If a fault within an electrical device connects a live supply conductor to an exposed conductive surface, anyone touching it while electrically connected to the earth will complete a circuit back to the earthed supply conductor and receive an electric shock.A protective earth (PE), known as an equipment grounding conductor in the US National Electrical Code, avoids this hazard by keeping the exposed conductive surfaces of a device at earth potential. To avoid possible voltage drop no current is allowed to flow in this conductor under normal circumstances. In the event of a fault, currents will flow that should trip or blow the fuse or circuit breaker protecting the circuit. A high impedance line-to-ground fault insufficient to trip the overcurrent protection may still trip a residual-current device (ground fault circuit interrupter or GFCI in North America) if one is present. This disconnection in the event of a dangerous condition before someone receives a shock, is a fundamental tenet of modern wiring practice and in many documents is referred to as automatic disconnection of supply (ADS). The alternative is defence in depth, where multiple independent failures must occur to expose a dangerous condition - reinforced or double insulation come into this latter category.In contrast, a functional earth connection serves a purpose other than shock protection, and may normally carry current. The most important example of a functional earth is the neutral in an electrical supply system. It is a current-carrying conductor connected to earth, often, but not always, at only one point to avoid flow of currents through the earth. The NEC calls it a groundED supply conductor to distinguish it from the equipment groundING conductor. Other examples of devices that use functional earth connections include surge suppressors and electromagnetic interference filters, certain antennas and measurement instruments.Regulations for earthing system vary considerably among countries and among different parts of electric systems. Most low voltage systems connect one supply conductor to the earth (ground).People use an earthing system mainly for these applications: To protect a structure from lightning strike, directing the lightning through the earthing system and into the ground rod rather than passing through the structure. Part of the safety system of mains electricity, preventing problems associated with floating ground and sky voltage. The most common ground plane for large monopole antenna and some other kinds of radio antenna.Other, less common applications of earthing systems include: single-wire earth return. part of a system that powers small devices from sky voltage. one at each end of a ground dipole ELF antenna.