• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Grid connected Converters for Photovoltaic, State of the
Grid connected Converters for Photovoltaic, State of the

... be build as a standard full-bridge for inverters with a transformer at the AC-side. For transformerless inverters other topologies (NPC, H5, HERIC, will be explained later) are used. 4) Power decoupling between DC- and AC-side: The power fluctuations between DC- and AC-side of the inverter (switchin ...
Superconducting Fault Current Limiters
Superconducting Fault Current Limiters

Calculation of Distributed Magnetic Flux Density under the Stator
Calculation of Distributed Magnetic Flux Density under the Stator

... Abstract This paper proposed an analytical model for the distributed magnetic field analysis of interior permanent magnet-type blush-less direct current motors under the stator-turn fault condition using the winding function theory. Stator-turn faults cause significant changes in electric and magnet ...
RF3827 数据资料DataSheet下载
RF3827 数据资料DataSheet下载

... RF3827 can be used as both low noise amplifier and linear transmit driver. Internal matching is such that the part can be used effectively in both 50 and 75 systems. The standard evaluation board is 50, as are the corresponding specifications shown within the data sheet. Perhaps more convenient f ...
Current input function
Current input function

... provide the pre-calculated current values to the subsequent software function blocks, deliver the calculated Fourier basic component values for on-line displaying. The current input function block receives the sampled current values from the internal operating system. The scaling (even hardware scal ...
Electronics-I Lecture-3
Electronics-I Lecture-3

1.2 This standard does not apply to
1.2 This standard does not apply to

DN302 - Ultraprecise Instrumentation Amplifier Makes Robust Thermocouple Interface
DN302 - Ultraprecise Instrumentation Amplifier Makes Robust Thermocouple Interface

... LTC2053 offers exceptionally low 10μV maximum input offset along with 116dB typical CMRR and PSRR, a result of a combination of switched capacitor and zero-drift op amp technologies. It is optimized for low voltage supplies from 2.7V to 11V single ended or up to ±5.5V with split supplies. The LTC205 ...
Project report
Project report

Faulted circuit indicator application guide COOPER POWER SERIES
Faulted circuit indicator application guide COOPER POWER SERIES

Part II - Indian Navy
Part II - Indian Navy

APC H10 Power Conditioner
APC H10 Power Conditioner

... Note: A product that is meant for uninterrupted service and for some specific reason, such as the possibility of the loss of an authorization code for a cable TV converter, is not intended to be unplugged by the user for cleaning or any other purpose, may exclude the reference to unplugging this dev ...
SECTION 16010
SECTION 16010

How to Coordinate Transformer Primary-Side Fuses with Feeder Reclosers Using Coordinaide
How to Coordinate Transformer Primary-Side Fuses with Feeder Reclosers Using Coordinaide

Student Text, pp. 479-481
Student Text, pp. 479-481

... conductor should be connected firmly to one of the terminals; the other wire should be touched momentarily to the other terminal. The resistance of the bare wire is very low. As a result, it draws a large current. This will cause the wire to get hot and the battery to discharge quickly if the termin ...
electrically isolated system response to rapid charging events using
electrically isolated system response to rapid charging events using

MAX14571/MAX14572/MAX14573 Adjustable Overvoltage and Overcurrent Protectors with High Accuracy EVALUATION KIT AVAILABLE
MAX14571/MAX14572/MAX14573 Adjustable Overvoltage and Overcurrent Protectors with High Accuracy EVALUATION KIT AVAILABLE

... The ICs feature programmable current-limit protection up to 4.2A. Once current reaches the threshold, the MAX14571 turns off after 20.7ms (typ) blanking time and stays off during the retry period. The MAX14572 latches off after the blanking time, and the MAX14573 limits the current continuously. A r ...
Power Supply Noise Reduction - The Designer`s Guide Community
Power Supply Noise Reduction - The Designer`s Guide Community

... Due to parasitics in the amplifier, the power supply rejection of the positive supply also deteriorates with frequency, but this is less severe than what occurs with the negative supply. This causes an asymmetrical pulse response. Typically, a positive-going pulse edge will have a response determine ...
H6HK Electric Heater Kit
H6HK Electric Heater Kit

Advantages of IC-Based Hot-Swap Circuit
Advantages of IC-Based Hot-Swap Circuit

... The MAX5902 controller keeps the MOSFET off when power is first applied. It maintains that off state indefinitely if the ON/OFF pin is held low, if the supply voltage is below the undervoltage lockout (UVLO) level, or if the die temperature exceeds +125°C (typ). If none of those conditions applies ...
Speeds Installation Time and Simplifies Wiring Wet Well Module
Speeds Installation Time and Simplifies Wiring Wet Well Module

Understanding Insulation Resistance Testing
Understanding Insulation Resistance Testing

FlexBar HRT Pressure Transmitter
FlexBar HRT Pressure Transmitter

SC-UN-FT - Universal Source Controller-Feed Through English Installation Guide
SC-UN-FT - Universal Source Controller-Feed Through English Installation Guide

... Source Controller via an external isolation breaker with sufficient capacity for the planned installation All Universal Source Controllers exceed the weight limit for one person lifting - always use at least two people when lifting and mounting the units Do not mix load types within a single channel ...
The Basic Principles of Electrical Overstress (EOS)
The Basic Principles of Electrical Overstress (EOS)

... more flux (light output) from the LEDs. The drawback of this type of protection circuitry is that the driver would require a power cycle following the activation of the feature. For the aforementioned reasons and due to cost, space limitations, and the wide range of targeted loads, the drivers do no ...
< 1 ... 127 128 129 130 131 132 133 134 135 ... 353 >

Earthing system

In electricity supply systems, an earthing system or grounding system is circuitry which connects parts of the electric circuit with the ground, thus defining the electric potential of the conductors relative to the Earth's conductive surface. The choice of earthing system can affect the safety and electromagnetic compatibility of the power supply. In particular, it affects the magnitude and distribution of short circuit currents through the system, and the effects it creates on equipment and people in the proximity of the circuit. If a fault within an electrical device connects a live supply conductor to an exposed conductive surface, anyone touching it while electrically connected to the earth will complete a circuit back to the earthed supply conductor and receive an electric shock.A protective earth (PE), known as an equipment grounding conductor in the US National Electrical Code, avoids this hazard by keeping the exposed conductive surfaces of a device at earth potential. To avoid possible voltage drop no current is allowed to flow in this conductor under normal circumstances. In the event of a fault, currents will flow that should trip or blow the fuse or circuit breaker protecting the circuit. A high impedance line-to-ground fault insufficient to trip the overcurrent protection may still trip a residual-current device (ground fault circuit interrupter or GFCI in North America) if one is present. This disconnection in the event of a dangerous condition before someone receives a shock, is a fundamental tenet of modern wiring practice and in many documents is referred to as automatic disconnection of supply (ADS). The alternative is defence in depth, where multiple independent failures must occur to expose a dangerous condition - reinforced or double insulation come into this latter category.In contrast, a functional earth connection serves a purpose other than shock protection, and may normally carry current. The most important example of a functional earth is the neutral in an electrical supply system. It is a current-carrying conductor connected to earth, often, but not always, at only one point to avoid flow of currents through the earth. The NEC calls it a groundED supply conductor to distinguish it from the equipment groundING conductor. Other examples of devices that use functional earth connections include surge suppressors and electromagnetic interference filters, certain antennas and measurement instruments.Regulations for earthing system vary considerably among countries and among different parts of electric systems. Most low voltage systems connect one supply conductor to the earth (ground).People use an earthing system mainly for these applications: To protect a structure from lightning strike, directing the lightning through the earthing system and into the ground rod rather than passing through the structure. Part of the safety system of mains electricity, preventing problems associated with floating ground and sky voltage. The most common ground plane for large monopole antenna and some other kinds of radio antenna.Other, less common applications of earthing systems include: single-wire earth return. part of a system that powers small devices from sky voltage. one at each end of a ground dipole ELF antenna.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report