• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Application Note: Medium Voltage Transformer Selection
Application Note: Medium Voltage Transformer Selection

RevG_102
RevG_102

... a Voc of 300 volts and then place a 5 ohm resistor across the generator output and verify the voltage measurement across the resistor is one half the Voc (+10%). If the Voc reduces to 135 volts, this would be within the +10% tolerance. In this case the generator impedance is a little over 6.1 ohms w ...
dranflex 3003xlb/6003xlb
dranflex 3003xlb/6003xlb

... WARNING Death, serious injury, or fire hazard could result from improper connection of this instrument. Read and understand these instructions and the Operator’s Manual before connecting this instrument. Follow all installation and operating instructions while using this instrument. Connection of t ...
OCXO Layout Guidelines - Connor
OCXO Layout Guidelines - Connor

evaluation of simple fault location on a mv feeder with dg
evaluation of simple fault location on a mv feeder with dg

... The DG is producing 3 MW at a power factor of 1. It is modeled as a synchronous generator, since it is the most common generator type in small hydro power plants. Simulated voltages and currents are converted to phasors using the Fast Fourier Transform. The values denoted as “during fault” are read ...
PowerLogic Multi-Circuit Meter
PowerLogic Multi-Circuit Meter

The Use of Low-Voltage Current-Limiting Fuses to Reduce Arc-Flash Energy Kenneth Borgwald
The Use of Low-Voltage Current-Limiting Fuses to Reduce Arc-Flash Energy Kenneth Borgwald

Reducing energy costs
Reducing energy costs

IOSR Journal of VLSI and Signal Processing (IOSR-JVSP)
IOSR Journal of VLSI and Signal Processing (IOSR-JVSP)

... values affect the number of OFF transistors in the NMOS and PMOS networks of a logic gate. For example, the minimum leakage current of a two-input NAND gate corresponds to he case when both its inputs are zero. In this case, both NMOS transistors in the NMOS network are off, while both PMOS transist ...
Experiment 2 AC circuit analysis
Experiment 2 AC circuit analysis

... After doing this experiment, students will be able to: i. ...
Electrical Appliances Testing Policy
Electrical Appliances Testing Policy

... Tests shall be done using a P.A.T (portable appliance tester) or appropriate testing equipment in accordance with the AS/NZS 3760. The P.A.T. should be routinely calibrated i.e. 6 monthly and to be maintained accurate to 5%. Larger departments are expected to purchase and maintain this equipment. Sm ...
UniGear 500R 17.5 kV, arc-proof, air insulated
UniGear 500R 17.5 kV, arc-proof, air insulated

... UniGear 500R in IEC version has the same overall dimensions (height and depth) and the same main busbar arrangement as UniGear ZS1 with a maximum current of 4000 A. The result is that it is possible to connect this panel to UniGear ZS1, 550 and MCC without the use of adaptor panel making it a very f ...
GS-Series Pinsetters - MC Bowling Services
GS-Series Pinsetters - MC Bowling Services

Site Considerations for Equipment Installation, Grounding
Site Considerations for Equipment Installation, Grounding

... pipes, cabinets or even the earth itself. Adjacent equipment may not have been properly wired or grounded, may be defective or may have one or more loose system grounds. Measure between the case of a questionable piece of equipment and its earth ground for voltage. If a voltage is present, something ...
AAT4626 数据资料DataSheet下载
AAT4626 数据资料DataSheet下载

... If an excessive load is applied to either output of an AAT4626, the load current will be limited by the device’s current limit circuitry. Refer to the “Current Limit” curve in the Typical Characteristics section of this datasheet. If a short circuit were to occur on the load applied to either the A ...
320lxf czone manual
320lxf czone manual

AAT4616A 数据资料DataSheet下载
AAT4616A 数据资料DataSheet下载

... The AAT4616A is a single channel current limiting load switch that is intended to protect against short circuit and over current events by current limiting to a preset level. This device also provides a reverse current blocking feature, ON/OFF enable control and a fault flag to notify a system contr ...
ADG419 数据手册DataSheet下载
ADG419 数据手册DataSheet下载

... Stresses above those listed under Absolute Maximum Ratings may cause permanent damage to the device. This is a stress rating only; functional operation of the device at these or any other conditions above those listed in the operational sections of this specification is not implied. Exposure to abso ...
ICTD-100CP / ICTD-101CP ICTD-102CP / ICTD
ICTD-100CP / ICTD-101CP ICTD-102CP / ICTD

36V H-Bridge Transformer Driver for Isolated Supplies General Description Benefits and Features
36V H-Bridge Transformer Driver for Isolated Supplies General Description Benefits and Features

... indirect limiting of secondary-side load currents. The current limit of the MAX13256 is set by an external resistor. A FAULT output asserts when the device detects an overtemperature or overcurrent condition. In addition, the device features a low-power mode to reduce the overall supply current to 0 ...
Lab 4 - Procedure Handout - Gateway Engineering Education
Lab 4 - Procedure Handout - Gateway Engineering Education

... SHOWN BELOW. NOTE this circuit uses the debounce circuit you just completed except the switch input is replaced by additional circuitry. The circuit should give a count pulse each time the light beam from the LED to the photocell is interrupted. ...
IEC 61000-4-x - AN96-07
IEC 61000-4-x - AN96-07

... short circuit current stress levels are defined with the 8 x 20µs waveform for power supply applications with a 2Ω source impedance. For data lines requiring a 42Ω source impedance, the short-circuit current waveform is defined as 8 x 20µs. For telecommunications applications, the open-circuit volta ...
Document
Document

MAX2181 FM Automotive Low-Noise Amplifier General Description Features
MAX2181 FM Automotive Low-Noise Amplifier General Description Features

... For best performance, the device must be mounted on a PCB that is designed for a low thermal resistance. A thermal ground must be placed near the device. This can consist of a mounting screw to a large thermal mass, ideally placed no more than 5mm from the package. The backside ground of the MAX2181 ...
Demagnetisation of CT cores under exposure of operating currents
Demagnetisation of CT cores under exposure of operating currents

... magnetisation. At the time when this experiment was made, it would have been probably ver y difficult to find out that the same reduction would have occurred most likely after 24 cycles and not only after 24 hours. Reference [3] displays some oscillographic recordings which indicate that most of the ...
< 1 ... 128 129 130 131 132 133 134 135 136 ... 353 >

Earthing system

In electricity supply systems, an earthing system or grounding system is circuitry which connects parts of the electric circuit with the ground, thus defining the electric potential of the conductors relative to the Earth's conductive surface. The choice of earthing system can affect the safety and electromagnetic compatibility of the power supply. In particular, it affects the magnitude and distribution of short circuit currents through the system, and the effects it creates on equipment and people in the proximity of the circuit. If a fault within an electrical device connects a live supply conductor to an exposed conductive surface, anyone touching it while electrically connected to the earth will complete a circuit back to the earthed supply conductor and receive an electric shock.A protective earth (PE), known as an equipment grounding conductor in the US National Electrical Code, avoids this hazard by keeping the exposed conductive surfaces of a device at earth potential. To avoid possible voltage drop no current is allowed to flow in this conductor under normal circumstances. In the event of a fault, currents will flow that should trip or blow the fuse or circuit breaker protecting the circuit. A high impedance line-to-ground fault insufficient to trip the overcurrent protection may still trip a residual-current device (ground fault circuit interrupter or GFCI in North America) if one is present. This disconnection in the event of a dangerous condition before someone receives a shock, is a fundamental tenet of modern wiring practice and in many documents is referred to as automatic disconnection of supply (ADS). The alternative is defence in depth, where multiple independent failures must occur to expose a dangerous condition - reinforced or double insulation come into this latter category.In contrast, a functional earth connection serves a purpose other than shock protection, and may normally carry current. The most important example of a functional earth is the neutral in an electrical supply system. It is a current-carrying conductor connected to earth, often, but not always, at only one point to avoid flow of currents through the earth. The NEC calls it a groundED supply conductor to distinguish it from the equipment groundING conductor. Other examples of devices that use functional earth connections include surge suppressors and electromagnetic interference filters, certain antennas and measurement instruments.Regulations for earthing system vary considerably among countries and among different parts of electric systems. Most low voltage systems connect one supply conductor to the earth (ground).People use an earthing system mainly for these applications: To protect a structure from lightning strike, directing the lightning through the earthing system and into the ground rod rather than passing through the structure. Part of the safety system of mains electricity, preventing problems associated with floating ground and sky voltage. The most common ground plane for large monopole antenna and some other kinds of radio antenna.Other, less common applications of earthing systems include: single-wire earth return. part of a system that powers small devices from sky voltage. one at each end of a ground dipole ELF antenna.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report