• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
A Tutorial on Calculating Source Impedance Ratios
A Tutorial on Calculating Source Impedance Ratios

... by a high SIR is the voltage measured at the relay for an outof-zone fault. If the SIR is high, the voltage will be small and measurement errors can dominate the reach calculation. Distance elements use a comparator that uses current and voltage. We can think of current as an operating quantity and ...
Aalborg Universitet Coordination between Fault-Ride-Through Capability and Overcurrent Protection of
Aalborg Universitet Coordination between Fault-Ride-Through Capability and Overcurrent Protection of

... generator rated current. The generator step up transformer is usually protected with fuses dimensioned to 2-3 times its rated current. The collector feeder protection is simplified considering it as a radial distribution feeder using overcurrent protection (50/51). A basic challenge arises due to th ...
AN96-07 - Semtech
AN96-07 - Semtech

... short circuit current stress levels are defined with the 8 x 20µs waveform for power supply applications with a 2Ω source impedance. For data lines requiring a 42Ω source impedance, the short-circuit current waveform is defined as 8 x 20µs. For telecommunications applications, the open-circuit volta ...
Document
Document

... as before. This current can be much higher than in the previous scheme. It is more reliable to work with higher currents. Leakage current compensation assured by a separate scheme (next slide). ...
Capacitor unbalance protection for blocks in double
Capacitor unbalance protection for blocks in double

... breakdown of an element, the fuse connected to it will blow and isolate it from the remaining part of the capacitor, which allows the unit to continue in service. The blowing of one or more fuses decreases the capacitance value and additionally it will cause voltage changes within the bank. If no in ...
Slide 1
Slide 1

... verifies that the insulation of a product or component is sufficient to protect the operator from electrical shock. In a typical Hipot test, high voltage is applied between a product's current-carrying conductors and its metallic chassis. The resulting current that flows through the insulation, know ...
IOM Manual
IOM Manual

Power Supply Rejection for Low Jitter Clocks
Power Supply Rejection for Low Jitter Clocks

Three Phase Transformers
Three Phase Transformers

4 Controls
4 Controls

A method of nonlinearities of transformer no
A method of nonlinearities of transformer no

Section 26 24 16
Section 26 24 16

... Schedules, after approval, shall be typed on the panel directory cards and installed in the appropriate panelboards, incorporating all applicable contract changes pertaining to that schedule. Include the room numbers and items served on the cards. E. Mount the panelboard fully aligned and such that ...
Building a CIM Network Model
Building a CIM Network Model

... VH = Vnominal-high VL = Vnominal-low ...
DC Machines
DC Machines

... 8.1 DC Motor • The direct current (dc) machine can be used as a motor or as a generator. • DC Machine is most often used for a motor. • The major advantages of dc machines are the easy speed and torque regulation. • However, their application is limited to mills, mines and trains. As examples, trol ...
Lecture Notes EEE 360
Lecture Notes EEE 360

... Conversion II ...
S320-42-1
S320-42-1

... intended solely for use with faulted circuit indicators being installed on dead-front design equipment. DO NOT USE the auxiliary contact feature on fault indicators being applied to overhead conductors or live-front equipment. Exposed ends of the auxiliary contact cable may contact bare conductors o ...
Components and Methods for Current Measurement
Components and Methods for Current Measurement

... The Power Metal Strip series all-metal welded construction with a CTE of approximately 13 ppm/°C is more compatible with the 18 ppm/°C CTE of the FR4 material, therefore stress due a CTE mismatch is significantly reduced. This leads to longterm reliability, which is the reason why the Power Metal St ...
MAX1894/MAX1924 Advanced Li+ Battery-Pack Protectors General Description Features
MAX1894/MAX1924 Advanced Li+ Battery-Pack Protectors General Description Features

... DSO, TKO, CGO to BN.............................-0.3V to (VSRC + 0.3V) B4P to B3P ...............................................................-0.3V to +6V B3P to B2P ...............................................................-0.3V to +6V B2P to B1P ............................................ ...
C h a p t e r   2
C h a p t e r 2

... instantaneously be opposed within the target by the field of this electric charge distribution created at the target boundaries. A secondary electric field created by these charges will cause a poloidal current flow that tends to cancel most of the primary electric field (i.e. the field associated w ...
Circuit Breaker Types.doc
Circuit Breaker Types.doc

... [edit] Origins An early form of circuit breaker was described by Edison in an 1879 patent application, although his commercial power distribution system used fuses. [1] Its purpose was to protect lighting circuit wiring from accidental short-circuits and overloads. ...
LGK-ID
LGK-ID

Fast Ignitron Trigger Circuit Using Insulated Gate Bipolar Transistors
Fast Ignitron Trigger Circuit Using Insulated Gate Bipolar Transistors

... current (100–250 A) pulse to the ignitor, a semiconducting rod which extends into the mercury pool that forms the ignitron’s cathode. Variance in turn-on time (jitter) will be minimized and ignitron lifetime prolonged if a high energy trigger pulse with peak current near the rated maximum is used [5 ...
Two-electrode non-differential biopotential amplifier
Two-electrode non-differential biopotential amplifier

... structure and uses a small number of components. The current source maintains balanced common-mode interference currents, thus ensuring high signal input impedance. In addition, these currents can be tolerated up to more than 10 mA per input, at a supply voltage of  5 V. A two-electrode differentia ...
The Sensitivity of the Input Impedance Parameters of Track Circuits
The Sensitivity of the Input Impedance Parameters of Track Circuits

LED Lighting Systems - CITEL Surge Protection
LED Lighting Systems - CITEL Surge Protection

... Surge Protective Devices for LED Outdoor Lighting ( courtesy of AEC Italy ) ...
< 1 ... 130 131 132 133 134 135 136 137 138 ... 353 >

Earthing system

In electricity supply systems, an earthing system or grounding system is circuitry which connects parts of the electric circuit with the ground, thus defining the electric potential of the conductors relative to the Earth's conductive surface. The choice of earthing system can affect the safety and electromagnetic compatibility of the power supply. In particular, it affects the magnitude and distribution of short circuit currents through the system, and the effects it creates on equipment and people in the proximity of the circuit. If a fault within an electrical device connects a live supply conductor to an exposed conductive surface, anyone touching it while electrically connected to the earth will complete a circuit back to the earthed supply conductor and receive an electric shock.A protective earth (PE), known as an equipment grounding conductor in the US National Electrical Code, avoids this hazard by keeping the exposed conductive surfaces of a device at earth potential. To avoid possible voltage drop no current is allowed to flow in this conductor under normal circumstances. In the event of a fault, currents will flow that should trip or blow the fuse or circuit breaker protecting the circuit. A high impedance line-to-ground fault insufficient to trip the overcurrent protection may still trip a residual-current device (ground fault circuit interrupter or GFCI in North America) if one is present. This disconnection in the event of a dangerous condition before someone receives a shock, is a fundamental tenet of modern wiring practice and in many documents is referred to as automatic disconnection of supply (ADS). The alternative is defence in depth, where multiple independent failures must occur to expose a dangerous condition - reinforced or double insulation come into this latter category.In contrast, a functional earth connection serves a purpose other than shock protection, and may normally carry current. The most important example of a functional earth is the neutral in an electrical supply system. It is a current-carrying conductor connected to earth, often, but not always, at only one point to avoid flow of currents through the earth. The NEC calls it a groundED supply conductor to distinguish it from the equipment groundING conductor. Other examples of devices that use functional earth connections include surge suppressors and electromagnetic interference filters, certain antennas and measurement instruments.Regulations for earthing system vary considerably among countries and among different parts of electric systems. Most low voltage systems connect one supply conductor to the earth (ground).People use an earthing system mainly for these applications: To protect a structure from lightning strike, directing the lightning through the earthing system and into the ground rod rather than passing through the structure. Part of the safety system of mains electricity, preventing problems associated with floating ground and sky voltage. The most common ground plane for large monopole antenna and some other kinds of radio antenna.Other, less common applications of earthing systems include: single-wire earth return. part of a system that powers small devices from sky voltage. one at each end of a ground dipole ELF antenna.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report