• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Integrating Bourns® Resistive Products to Control Current and
Integrating Bourns® Resistive Products to Control Current and

Strand Dimming Systems Power and Diming Control solutions for
Strand Dimming Systems Power and Diming Control solutions for

A4954 - Elecanisms
A4954 - Elecanisms

... The A4954 is designed to operate two DC motors. The output drivers are all low-RDS(on) , N-channel DMOS drivers that feature internal synchronous rectification to reduce power dissipation. The current in each of the two output full bridges is regulated with fixed off-time pulse width modulated (PWM) ...
Homework Set 3
Homework Set 3

Electricity and Magnetism Test
Electricity and Magnetism Test

... Electricity and Magnetism Study Guide 1. If two charges repel each other, the two charges must be… 2. A device that can convert chemical energy to electrical energy is a… 3. An object becomes charged when the atoms in the object gain or lose… 4. What type of current comes from the outlets in your ho ...
Data Centers - engineering site
Data Centers - engineering site

... current are possible, there is no real site measurement exceeding 100% neutral current (In practice, standard circuit load is 50% of maximum current). Applications with currents < 200A These applications are the most likely to have higher than nominal neutral current values. The maximum theoretical ...
Q101-006 - Automotive Electronics Council
Q101-006 - Automotive Electronics Council

PDF
PDF

... current interruption (FCI) function. The former function has been presented in and the latter is described in this paper. It should be noted that limiting the fault current by the DVR disables the main and the backup protection (e.g., the distance and the over current relays). This can result in pro ...
Complex Impedance Measurement Device for Alkaline Batteries
Complex Impedance Measurement Device for Alkaline Batteries

... possible to provide a high accuracy external crystal oscillator through the MCLK (Pin 8). The system clock value should be reduced if the excitation frequency is < 5kHz that is further explained in the datasheet [8]. If the user requires measuring small impedances such as alkaline battery impedance ...
parallel
parallel

... • Easy to set up (cheap) • Batteries in series: voltages additive, increases current • Less connectors needed ...
Constant Current Constant Voltage Buck
Constant Current Constant Voltage Buck

Polylux_Comp_gb1.pps
Polylux_Comp_gb1.pps

... The main advantage of the Compensator is the absence of electronic components and capacitors. The Compensators are therefore maintenance free, have an extremely long lifetime compared with other types of filters and are compatible with any electrical installation ...
Master Notes
Master Notes

MAX1838 Dual USB Switch with Fault Blanking and Autoreset General Description
MAX1838 Dual USB Switch with Fault Blanking and Autoreset General Description

... auxiliary input supply. Each switch meets all IEC specifications for USB ports and is guaranteed to supply 500mA from either of two input supplies. A control pin selects the power source from either the main or auxiliary supply. The MAX1838 has multiple protection features, including independent the ...
Laboratory Manual
Laboratory Manual

PDF
PDF

... Fig. 4 global model of supply studied for a magnetron The figure 4 shows the incorporation of the equivalent circuit in π of the transformer in the power supply from the electric and magnetic equations of its operation. The advantage of this model is presented in its single-phase equivalent circuit ...
Basics of Switchboards
Basics of Switchboards

Technique for Accurate Voltage Measurement of Energized Street
Technique for Accurate Voltage Measurement of Energized Street

... distribution system’s neutral return current. It exists in any 4 wire distribution system, but becomes large enough to cause problems mostly at the end of long circuits, where load-to-source impedance is highest. Voltage fluctuates with circuit loading, but is relatively low (<10V) and steady state ...
Chapter 10 Magnets Notes
Chapter 10 Magnets Notes

... Both electrical force and magnetic force exist between electric charges. Scientists now believe both forces are two aspects of one force, the electromagnetic force. A current through a wire creates a magnet. The reverse is also true: If a magnet is moved through a coil of wire, then electric curren ...
Transmission System Supply Reliability and Quality Regulation
Transmission System Supply Reliability and Quality Regulation

... unless otherwise indicated by TEIAS. In cases where a special earthing infrastructure is required for connections to the transmission system, the technical requirements to be fulfilled for earthing and the results of analyses to be conducted upon rises in voltage is communicated to the user by TEIAS ...
SECTION 701 LOCATIONS CONTAINING A BATH OR
SECTION 701 LOCATIONS CONTAINING A BATH OR

... Where high density livestock rearing exists, food, water, temperature & ventilation:- suitably designed, installed and monitored with standby supplies if required. ...
TR41.7-01-05-009-TR41.7.2CostaMesa607ASpecificComments
TR41.7-01-05-009-TR41.7.2CostaMesa607ASpecificComments

... UTP cable to extend the Telecommunications Main Grounding Busbar (TMGB) in the telecommunications Entrance Facility (TEF) to certain types of ac-powered terminal equipment. It is intended to minimize, through mutual coupling with UTP cable conductors, lightning-introduced surge voltages between the ...
Bathroom Zone Information
Bathroom Zone Information

... - All circuits of the location must have additional protection provided by one or more RCDs that have a rated residual operating current (IΔ n ) not exceeding 30 mA and an operating time not exceeding 40 ms at a residual current of 5 IΔ n (701.411.3.3). - Providing all final circuits of the location ...
DC power supply connect to inverter
DC power supply connect to inverter

Arc flash hazards
Arc flash hazards

... to biomedical engineering, electric power and consumer electronics among others. NEC National Electrical Code. A set of regulations pertaining to electrical installation and design in the interest of the protection of life and property for the United States. Published biennially by the NFPA, (NFPA 7 ...
< 1 ... 134 135 136 137 138 139 140 141 142 ... 353 >

Earthing system

In electricity supply systems, an earthing system or grounding system is circuitry which connects parts of the electric circuit with the ground, thus defining the electric potential of the conductors relative to the Earth's conductive surface. The choice of earthing system can affect the safety and electromagnetic compatibility of the power supply. In particular, it affects the magnitude and distribution of short circuit currents through the system, and the effects it creates on equipment and people in the proximity of the circuit. If a fault within an electrical device connects a live supply conductor to an exposed conductive surface, anyone touching it while electrically connected to the earth will complete a circuit back to the earthed supply conductor and receive an electric shock.A protective earth (PE), known as an equipment grounding conductor in the US National Electrical Code, avoids this hazard by keeping the exposed conductive surfaces of a device at earth potential. To avoid possible voltage drop no current is allowed to flow in this conductor under normal circumstances. In the event of a fault, currents will flow that should trip or blow the fuse or circuit breaker protecting the circuit. A high impedance line-to-ground fault insufficient to trip the overcurrent protection may still trip a residual-current device (ground fault circuit interrupter or GFCI in North America) if one is present. This disconnection in the event of a dangerous condition before someone receives a shock, is a fundamental tenet of modern wiring practice and in many documents is referred to as automatic disconnection of supply (ADS). The alternative is defence in depth, where multiple independent failures must occur to expose a dangerous condition - reinforced or double insulation come into this latter category.In contrast, a functional earth connection serves a purpose other than shock protection, and may normally carry current. The most important example of a functional earth is the neutral in an electrical supply system. It is a current-carrying conductor connected to earth, often, but not always, at only one point to avoid flow of currents through the earth. The NEC calls it a groundED supply conductor to distinguish it from the equipment groundING conductor. Other examples of devices that use functional earth connections include surge suppressors and electromagnetic interference filters, certain antennas and measurement instruments.Regulations for earthing system vary considerably among countries and among different parts of electric systems. Most low voltage systems connect one supply conductor to the earth (ground).People use an earthing system mainly for these applications: To protect a structure from lightning strike, directing the lightning through the earthing system and into the ground rod rather than passing through the structure. Part of the safety system of mains electricity, preventing problems associated with floating ground and sky voltage. The most common ground plane for large monopole antenna and some other kinds of radio antenna.Other, less common applications of earthing systems include: single-wire earth return. part of a system that powers small devices from sky voltage. one at each end of a ground dipole ELF antenna.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report