• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
ComboLight New Construction Recessed w/Trim - 12V AR111 - 6 Light
ComboLight New Construction Recessed w/Trim - 12V AR111 - 6 Light

... configuration available. ...
Optimal Placement of UPFC to Enhance Power System Voltage
Optimal Placement of UPFC to Enhance Power System Voltage

AVC63-12 and AVC125-10 Voltage Regulators
AVC63-12 and AVC125-10 Voltage Regulators

... controllers, the AVC63-12 and the AVC125-10. These environmentally rugged products are ideally suited for controlling the output of brushless excited synchronous generators up to 5MW. These devices offer higher powered output and accept a variety of accessory items for new and retrofit applications ...
Set No. 1
Set No. 1

Installation Instructions
Installation Instructions

... 3. Connect proper transformer to terminals marked [AC] (Voltage Output/Transformer Selection Table). Use 18 AWG or larger for all power connections (Battery, DC output). Keep power-limited wiring separate from non power-limited wiring (115VAC / 60Hz Input, Battery Wires). Minimum 0.25” spa ...
Design Review
Design Review

... • 2. An ability to aim the projectile by controlling of the azimuth and elevation angles of the barrel • 3. An ability to charge a capacitor bank to a variable voltage, up to 400V • 4. An ability to gather images and perform target recognition and tracking • 5. An ability for a user to enter command ...
a-d conversion
a-d conversion

... Sources of Error • The fact that we are using a converter which has a finite number of bits introduces an error called “quantization error” • The fact that it takes a finite (non-zero) amount of time to perform the conversion introduces the possibility of an error called ...
LectureOutline-Circuits [Compatibility Mode]
LectureOutline-Circuits [Compatibility Mode]

KFD2-CR4-1.2O Transmitter Power Supply Connection Assembly
KFD2-CR4-1.2O Transmitter Power Supply Connection Assembly

... Both outputs provide a 0/4 mA ... 20 mA current corresponding to the input signal. The minimum available field voltage is 16 V at 20 mA. If necessary, the internal resistance of 250 Ω between terminals 8, 9 and 11, 12 can be used for conversion into a 0 V ... 5 V voltage signal. ...
Lab 8 - La Salle University
Lab 8 - La Salle University

... Flip-flops serve as the elementary units for memory in digital systems. Two features are needed: 1. The circuit must be able to “hold” either state (a high or low output) and not simply reflect the input at any given time. 2. But in some circumstances, we must be able to change (to “set” and “reset” ...
Modeling and Simulation of Intelligent Controller of Solar Energy
Modeling and Simulation of Intelligent Controller of Solar Energy

voltagesummary
voltagesummary

Lab 2 - Faculty
Lab 2 - Faculty

... Original Location Between R1 and R2 Between R2 and R3 Between R3 and common Table 3. 2. Using circuit 6, move the position of the milliammeter from its position between R1 and R2 to a position between R2 and R3. Record the current in Table 3. 3. Using circuit 6, move the position of the milliammeter ...
return loss
return loss

... output of an amp, tap, modulator), transmission medium (coaxial cable) and a termination (input to a tap, amp, cable modem, etc.). If the impedances of all three are exactly the same, all power transmitted by the source is absorbed by the termination. The assumption here is that the transmission med ...
8.  Electric Power AP1000 Design Control Document
8. Electric Power AP1000 Design Control Document

... loss of the normal, preferred, and maintenance power sources. The reserve auxiliary transformers also serve as a source of maintenance power. The maintenance sources are site-specific. Maintenance power is provided at the medium voltage level (6.9 kV) through normally open circuit breakers. Bus tran ...
Iris Power PDAlert Bantam PD Detection During Short Risetime Voltage Surges
Iris Power PDAlert Bantam PD Detection During Short Risetime Voltage Surges

... The introduction of modern voltage source, pulse width modulated inverters using IGBTs/IGCTs in the early 1990s created a new stator winding failure mechanism in motors rated as low as 440 V. In “random wound” motor stator windings typical of motors rated less than 1000 V, partial discharges were fo ...
HECO Dynamics Seminar - Alaska Energy Authority
HECO Dynamics Seminar - Alaska Energy Authority

... Typical ramp rates for thermal units in Railbelt range from1.25 MW/ minute to 3.4 MW/minute Typical ramp rates for hydros range from 5 MW/minute to 25 MW/minute Hydros have time constants of 7-15 seconds for upward regulation ...
pad1 pad2 pad5 pad10 pad20 pad50 pad100 pad200 pad500
pad1 pad2 pad5 pad10 pad20 pad50 pad100 pad200 pad500

... CONTROL SIGNAL ...
APPLICATION BULLETIN
APPLICATION BULLETIN

... Electrical energy is the same regardless of the system configuration in which it is measured. In other words, 500 watts is 500 watts regardless of whether it is distributed throughout a 3 phase wye (Y) system or a delta (∆) configured system. Blondel’s Theorem suggests that the number of watt meters ...
12a VELCO stationery
12a VELCO stationery

... These meetings are part of VELCO’s public outreach. The purpose of the meetings is to share the proposed project plans and to give us a chance to listen to your concerns and suggestions prior to our formal application for a Certificate of Public Good (the ”Section 248” permit process),which is expec ...
Q25085089
Q25085089

4 Controls
4 Controls

... 3.5 The following data must be sent in real time from the substation of the windpark to the Elering Electricity System Control Centre: 3.5.1 the maximum possible active power (MW) 3.5.2 the total nominal active power (MW) of wind turbines under repair, 3.5.3 the total nominal active power (MW) of wi ...
6. Organization, training and methodological support of students` self
6. Organization, training and methodological support of students` self

... Hardware is set of experimental set-ups with real high voltage equipment and high voltage level. They are: 1. Facility for AC and DC high voltage generation with measuring system for research electro-physical processes in gases. 2. Marx generator with pulsed voltage level up to 300 kV. 3. Marx gener ...
A Carrier-Based Neutral Voltage Modulation Strategy for Multilevel
A Carrier-Based Neutral Voltage Modulation Strategy for Multilevel

Skalar Devices
Skalar Devices

... Optional hardware modules extend the scope of Skalar applications. Whatever you want to do – routing, pulse recording, switching or recording status messages – the flexible device concept always meets your demands and almost every application needs only one device: Skalar. The integrated user admini ...
< 1 ... 991 992 993 994 995 996 997 998 999 ... 1160 >

Electrical substation



A substation is a part of an electrical generation, transmission, and distribution system. Substations transform voltage from high to low, or the reverse, or perform any of several other important functions. Between the generating station and consumer, electric power may flow through several substations at different voltage levels.Substations may be owned and operated by an electrical utility, or may be owned by a large industrial or commercial customer. Generally substations are unattended, relying on SCADA for remote supervision and control.A substation may include transformers to change voltage levels between high transmission voltages and lower distribution voltages, or at the interconnection of two different transmission voltages. The word substation comes from the days before the distribution system became a grid. As central generation stations became larger, smaller generating plants were converted to distribution stations, receiving their energy supply from a larger plant instead of using their own generators. The first substations were connected to only one power station, where the generators were housed, and were subsidiaries of that power station.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report