• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
The desired DC voltage increase from 420 to 600 V is shown in
The desired DC voltage increase from 420 to 600 V is shown in

... severe power quality issue which can produce damage to LV DC motors if this condition is not properly detected and action taken to disconnect the DC drive from the power supply. Similar voltage fluctuations on customer’s sensitive equipment fed through rectifiers can also become negatively impacted ...
DIN Low Voltage Relay Station
DIN Low Voltage Relay Station

... LVRS8-DIN and RadioLink™ model, STOLER821 feature 8 isolated, latching relay channels for switching low-voltage or dry contact closures to third party systems or devices. The DIN Low Voltage Relay Station (LVRS) does not produce or provide any power. Each relay is single-pole, double-throw, which of ...
Zero Current Monitor E-1076-SR 5
Zero Current Monitor E-1076-SR 5

... current transformer and an opto decoupled output circuit with a triac (with AC output circuit) or transistor (with DC output circuit). The current transformer in the monitoring circuit does not only supply the input signal but also the very low power consumption of the Monitor. Zero current monitors ...
Speed control for HF MIG welders I bought a Harbor Freight “Dual
Speed control for HF MIG welders I bought a Harbor Freight “Dual

AC Current transducer AP
AC Current transducer AP

... In order to guarantee safe operation of the transducer and to be able to make proper use of all features and functions, please read these instructions thoroughly! Safe operation can only be guaranteed if the transducer is used for the purpose it has been designed for and within the limits of the tec ...
Ahmed Tarek Reda sec(1)
Ahmed Tarek Reda sec(1)

... be easily implemented. The thermistor offers a low resistance at high temperature and high resistance at low temperature. This phenomenon is employed here for sensing the fire. The IC1 (NE555) is configured as a free running oscillator at audio frequency. The transistors T1 and T2 drive IC1. The out ...
doc
doc

... voltages due to the fault. Change from what? It is the change from the voltage without the fault, i.e., it is the pre-fault voltage. Consider any bus, let’s say bus j, with a prefault voltage of Vj. Then we can compute the bus j voltage under the faulted condition ...
Power amplifier 65W with HEXFET
Power amplifier 65W with HEXFET

... and no by current as the classically bipolar transistors. The circuit has symmetrical designing, resolving thus the harmonic distortion problem. All the transistors that are used in the circuit are simple and they exist in big clearings in the market. The pairs of differential amplifiers Q1-2 and Q3 ...
05 CMNB Block 3 Session 4
05 CMNB Block 3 Session 4

... course this is impossible but clearly Icap is extremely large and charges the membrane within a very small time (nannoseconds?). At 1ms, dV/dt = 0. The voltage is not changing with time during the step. Thus, from the equation, Icap = C * zero so Icap = zero. It is one of the important features of t ...
Buck-Boost converter circuit drawing
Buck-Boost converter circuit drawing

Zen Variations 8
Zen Variations 8

Mapping the Electric Field-
Mapping the Electric Field-

... region. Do this for the potentials of 2 volts, 4 volts, 6 volts, 8 volts, 10 volts, 12 volts, and 14 volts. 3. Record the potential inside the ring. Move the probe around and note the constant potential inside. C. Make a drawing 1. Locate the conductors on the graph. Although really ac, consider the ...
UML4N
UML4N

... The contents described herein are subject to change without notice. The specifications for the product described in this document are for reference only. Upon actual use, therefore, please request that specifications to be separately delivered. Application circuit diagrams and circuit constants cont ...
comparative study of different control strategies for
comparative study of different control strategies for

MEEPP 201 Power Electronic System Control -set1
MEEPP 201 Power Electronic System Control -set1

... 5. (a) Draw the block schematic diagram of a Switched Mode Power Supply. ...
two load line of vdb amplifier
two load line of vdb amplifier

... Class A operation of an amplifier means that the transistor operates in the active region at all times. Fig(a) shows Class A Amplifier. Output is not clipped. Collector current flows for 360° throughout the cycle. Some parameters useful in Class A Amplifiers are Power Gain Output Power, etc. With a ...
High Voltage System
High Voltage System

Level-Shifting MOSFET Driver
Level-Shifting MOSFET Driver

Current Transformers
Current Transformers

... A current transformer is an instrument that transforms one current value to another current value (e.g. 100A to 5A.) The advantage of using a current transformer in an industrial context is that it provides galvanic isolation from the voltage on the primary winding while simultaneously furnishing a ...
External Amplifier Keying from the IC-706
External Amplifier Keying from the IC-706

... The IC-706 now keys my amplifiers, but it gives the Alpha fits—not because of the T/R switching, but because the Alpha is a fully-protected high gain amp, and the IC-706 has an awful, full power leading edge spike than trips the overdrive protection. Even when the IC-706 is adjusted to the 40W or so ...
RC Circuits - McMaster Physics & Astronomy Outreach
RC Circuits - McMaster Physics & Astronomy Outreach

... vi) Final voltage across the capacitor ...
P6G
P6G

... Isolating transformers are designed to improve the safety of some electrical circuits, rather than change the voltage. ...
Bertan 230 Series of High Voltage Power Supplies, Spellman High
Bertan 230 Series of High Voltage Power Supplies, Spellman High

... Front Panel Metering and Controls: Power ON/OFF switch 3.5 digit metering for voltage and current, switch selectable Polarity indicator 10 turn locking potentiometer to set output voltage HV output connector ...
Series_Parallel_Connection_on_GS_1
Series_Parallel_Connection_on_GS_1

... In case of parallel connection of voltage source, one source is overload for the other one. (supposed to internal impedance of voltage source ≒0 Ω) The output current I1 and I2 are balanced each other, or either of them reach to the current limiter value and the other compensates for balancing. Ther ...
Field Instruction
Field Instruction

... restoration or corrective work is complete, all HPCC and Customer protection and control equipment is operational and the Horizon Power Network is stable. To enable the PPG to be reconnected to the Network upon the customers requestion, HPCC shall send an ‘Enable’ signal from the SCADA. ...
< 1 ... 989 990 991 992 993 994 995 996 997 ... 1160 >

Electrical substation



A substation is a part of an electrical generation, transmission, and distribution system. Substations transform voltage from high to low, or the reverse, or perform any of several other important functions. Between the generating station and consumer, electric power may flow through several substations at different voltage levels.Substations may be owned and operated by an electrical utility, or may be owned by a large industrial or commercial customer. Generally substations are unattended, relying on SCADA for remote supervision and control.A substation may include transformers to change voltage levels between high transmission voltages and lower distribution voltages, or at the interconnection of two different transmission voltages. The word substation comes from the days before the distribution system became a grid. As central generation stations became larger, smaller generating plants were converted to distribution stations, receiving their energy supply from a larger plant instead of using their own generators. The first substations were connected to only one power station, where the generators were housed, and were subsidiaries of that power station.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report