• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Typical Factory Test Procedures for Medium
Typical Factory Test Procedures for Medium

... • Check that appropriate barriers are in place to isolate all medium voltage compartments. Barriers are to ensure that personnel cannot touch live medium voltage in a cell that is otherwise de-energized. 5. Verify that bus and bus connections have proper clearance, creepage, phasing, and torque. • V ...
Charging System Fundamentals
Charging System Fundamentals

1 or 2Ø – High Performance AC Power Source 6,000VA 15
1 or 2Ø – High Performance AC Power Source 6,000VA 15

High Power AC Drive and Motor Applications
High Power AC Drive and Motor Applications

... density NdFeB magnets with high TC superconducting magnets. The zero dc resistance offered by superconducting wires allows very high current densities to be conducted by the wires resulting in very high magnetic field generation. Furthermore, the associated zero wire resistance results in low synchr ...
International Electrical Engineering Journal (IEEJ) Vol. 5 (2014) No.11, pp. 1632-1638
International Electrical Engineering Journal (IEEJ) Vol. 5 (2014) No.11, pp. 1632-1638

... updating factor, whose value is derived from fuzzy logic, with the plant error and error change ratio as input variables. The result shows the effective control rule reduction of the proposed methods which can be carried out on a four-phase 8/6 pole SRM are given to show the very good stability and ...
maxon DC motor and maxon EC motor Key information
maxon DC motor and maxon EC motor Key information

... Therefore, the apparent torque produced is lower. Current is also fed back into the controller’s power stage. As a result, motor behaviour deviates from the ideal linear speed-torque gradient. The apparent speed-torque gradient depends on voltage and speed: The gradient is steeper at higher speeds. ...
A Constant-current Source - BYU Physics and Astronomy
A Constant-current Source - BYU Physics and Astronomy

... Two of the capacitors in this circuit serve as low-pass filters to reduce high-frequency noise in the output current. The first, C3, is a 0.01 µF capacitor in parallel with the current output. This capacitor is added to reduce the level of high-frequency noise at the current output. The value of thi ...
i-class Induction Heating
i-class Induction Heating

... 19"-Power Supply ...
Automotive Qualified 40V to 100V Gen 10.2 MOSFETs
Automotive Qualified 40V to 100V Gen 10.2 MOSFETs

Electric Drives Experiment 2 Two-Pole Switch-Mode DC Converter and
Electric Drives Experiment 2 Two-Pole Switch-Mode DC Converter and

Identified – Functionality and Features of Electric Motors
Identified – Functionality and Features of Electric Motors

... cles have the simplest type of electric powertrain: a high-voltage battery pack provides direct current power (DC), which is converted by a frequency in­ verter into three-phase alternating current power (AC) of variable frequency. The electric motor finally converts the electric power into mechanic ...
AC Circuit
AC Circuit

... A Capacitor in an AC Circuit ...
display
display

Study and Simulation of Current Controlled PWM Inverters
Study and Simulation of Current Controlled PWM Inverters

... detail in [1].These are thus essentially open loop systems where the switching patterns are predetermined. There is no feedback and thus the system cannot ensure whether the output voltages and currents remain within desired margins. Current in this case and the nature of current (both magnitude and ...
Project Proposal
Project Proposal

... leakage. For each circuit we would analyze the worst case input transitions, and calculate power dissipated for the best voltage regulator. ...
lab4a - inst.eecs.berkeley.edu
lab4a - inst.eecs.berkeley.edu

... MOSFET, shorting the drain and gate gives a two-terminal device with behavior that is qualitatively diode-like, but has a (roughly) quadratic current-voltage relationship. Even though it’s decidedly not a diode, people still often call this drain-to-gate shorted device “diode-connected”. Build the d ...
Catheter Guidewire Control System
Catheter Guidewire Control System

High Power Common Mode Chokes for 1- and 3-Phase
High Power Common Mode Chokes for 1- and 3-Phase

Installation Instructions For SLO
Installation Instructions For SLO

... GENERAL SAFETY INFORMATION Dangerous voltages, currents, temperatures, and energy levels exist within this unit, on certain accessible terminals, and at the motor. NEVER operate the unit with its protective cover removed! Exercise caution when installing and using this unit. Only qualified personnel ...
M22087093
M22087093

... hydropower farms [2]-[5]. The basic principle of the alternative energy relates to issues of sustainability, renewability and pollution reduction. The low energy conversion and the cost of the photovoltaic systems compared with the wind power promote using the wind power systems. In the recent years ...
IRIS POWER Volume 1, Issue 1 February 2006
IRIS POWER Volume 1, Issue 1 February 2006

... the presence of inverter voltage impulses. Qualification and Testing of Stator Insulation Systems for Inverter Duty Motors Probably the most important new technical specification concerning machine insulation systems to be developed in the past 20 years is IEC 60034 Part 18 - 41: Rotating Electrical ...
Design of a 4-pole Line Start Permanent Magnet Synchronous Motor
Design of a 4-pole Line Start Permanent Magnet Synchronous Motor

Motors and Generators Revision for Trials
Motors and Generators Revision for Trials

MDS-065APS24 B Datasheet
MDS-065APS24 B Datasheet

... The MDS series of embedded power supply come with universal AC input at 90Vac to 264Vac. Other features include low touch current, risk management report available and the electric shock protection comply with 2 x MOPP. The MDS series is certified for EMC standards according to EN 55011 for industri ...
Document
Document

< 1 ... 1111 1112 1113 1114 1115 1116 1117 1118 1119 ... 1315 >

Variable-frequency drive



A variable-frequency drive (VFD) (also termed adjustable-frequency drive, variable-speed drive, AC drive, micro drive or inverter drive) is a type of adjustable-speed drive used in electro-mechanical drive systems to control AC motor speed and torque by varying motor input frequency and voltage.VFDs are used in applications ranging from small appliances to the largest of mine mill drives and compressors. However, around 25% of the world's electrical energy is consumed by electric motors in industrial applications, which are especially conducive for energy savings using VFDs in centrifugal load service, and VFDs' global market penetration for all applications is still relatively small. That lack of penetration highlights significant energy efficiency improvement opportunities for retrofitted and new VFD installations.Over the last four decades, power electronics technology has reduced VFD cost and size and has improved performance through advances in semiconductor switching devices, drive topologies, simulation and control techniques, and control hardware and software.VFDs are available in a number of different low- and medium-voltage AC-AC and DC-AC topologies.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report