• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
DIY Kit 125 - NEGATIVE ADJUSTABLE POWER SUPPLY
DIY Kit 125 - NEGATIVE ADJUSTABLE POWER SUPPLY

... The regulator develops a nominal 1.25V reference voltage between the output and adjust terminals. This constant voltage is applied across R1, causing a constant current to flow. This constant current flows through trimpot VR1. By varying VR1, the voltage across it will vary and hence the output volt ...
IU3416131619
IU3416131619

... utilizes flooded lead-acid battery cell for energy storage. For electrical energy storage application, a large number of cells are connected in series to produce the required operating voltage [6], [7]. In order to verify the effectiveness of proposed system, the current control mode of voltage sour ...
Technical Datasheet for Series OLH10K 10kW
Technical Datasheet for Series OLH10K 10kW

... voltage power supplies designed to meet the rigorous requirements of ion and electron beam systems, ion implantation and X-ray equipment. There are three different input voltage variants available to order: the OLH10K (208VAC), the OLH10KC (380VAC) and the OLH10KE (400VAC). The systems consist of tw ...
III. 3-phase Active Shunt Filter - Faculdade de Engenharia
III. 3-phase Active Shunt Filter - Faculdade de Engenharia

... electronics has a main role on this task. Two VSWT topologies are emerging as preferred technologies. Doubly-Fed Induction Generator (DFIG) wind turbines utilize a wound rotor induction generator, where the rotor winding is fed through back-to-back variable frequency, voltage source converters [3]. ...
Jun 1999 The LT1576: 200kHz, 1.5A Monolithic
Jun 1999 The LT1576: 200kHz, 1.5A Monolithic

... reduced from 3.5V (LT1376) to 3V. Current used by the boost circuit is considered an efficiency loss. Supplying current from a lower voltage via the boost diode, D2, improves the efficiency. For most applications with outputs above 3V, the configuration shown in Figure 2 is optimal. Converters with ...
Hazardous Location, Sealed Lead Calcium Battery
Hazardous Location, Sealed Lead Calcium Battery

... The unit incorporates a solidstate switching transistor which eliminates corroded and pitted contacts or mechanical failures associated with relays. The switching circuit is designed to detect a loss of AC voltage and automatically energizes the lamps. Upon restoration of the AC power, the emergency ...
1395 Connection Guide - Allen
1395 Connection Guide - Allen

Transient over Voltage Due to Switching Operation of Industrial
Transient over Voltage Due to Switching Operation of Industrial

... operation. A method based on R-C surge suppression in reducing the peak surge magnitude is reported by Vollety et al. [1]. It is known that current chopping in vacuum contactors and breakers also lead to generation of higher transient voltages. Electric drives in heavy industries are mostly located ...
SONOVISION
SONOVISION

... Sonovision is a ruggedised, portable ultrasonic inspection system capable of simultaneous multi-channel Time-of-Flight-Diffraction (TOFD) and Pulse Echo (PE) Corrosion/Erosion Mapping capable of interfacing to a wide range of single/multi-axis manipulators including video tracking. The system comes ...
TruWave VLT Sinewave Power Inverters
TruWave VLT Sinewave Power Inverters

STN851-A
STN851-A

... UNLESS OTHERWISE SET FORTH IN ST’S TERMS AND CONDITIONS OF SALE ST DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTY WITH RESPECT TO THE USE AND/OR SALE OF ST PRODUCTS INCLUDING WITHOUT LIMITATION IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE (AND THEIR EQUIVALENTS UNDER THE LAWS ...
programmable ac power source model 61700 series
programmable ac power source model 61700 series

... be controlled by a powerful and user-friendly softpanel through GPIB or RS-232 inter face. Besides that, the softpanel includes a waveform editor that can edit up to 40th order harmonic components. By this way, the 61700 series get the ability to output distorted waveform as users like. The self-dia ...
504e - İnfotek
504e - İnfotek

Lecture_15_SRAM_52
Lecture_15_SRAM_52

... Forward BB: stronger PMOS makes a wider butter fly curve more SNM during read operation Higher leakage (only applied on selected banks) ...
Workshop Materials
Workshop Materials

Ted3
Ted3

... 3. Starts sending the IR stream. If the joystick is not moved for 5 seconds, a small bip is given, so you will not forget to switch off TED when you have fineshed using it. ...
Current Transducer HAT 200..1500
Current Transducer HAT 200..1500

... Pins Arrangement ...
White paper - Power Factor and Input Current Distortion
White paper - Power Factor and Input Current Distortion

Datasheet Danfoss TLX8
Datasheet Danfoss TLX8

... to harvest all the energy of the PV modules. ...
Fault Finding
Fault Finding

An introduction to AC/DC power supply as a simple system
An introduction to AC/DC power supply as a simple system

... DC-DC Converter • Most modern power supplies also contain one or more DC-DC converters • Modern electronics often demand different voltages to function. • A DC-DC converter changes one DC voltage to another, higher or lower DC voltage. • A DC-DC converter is used with a power supply to prevent the ...
Electrical Faults Simulation Trainer ESAE www.edibon.com Technical Teaching Equipment
Electrical Faults Simulation Trainer ESAE www.edibon.com Technical Teaching Equipment

... Electrical Faults Simulation Trainer ESAE Technical Teaching Equipment ...
Interconnection Application/Agreement - Part 1
Interconnection Application/Agreement - Part 1

... the specific information necessary for the EDC to adequately evaluate the impact of the proposed facility on the EDC’s electrical distribution system at the time of the initial application. Often times the equipment for which this information is needed hasn’t been specified. The type information nec ...
Blue-Box Approach to Power Electronics and
Blue-Box Approach to Power Electronics and

... presented. Schematics and construction techniques for the hardware are publicly available. Index Terms — Power engineering education, education, energy conversion, educational technology ...
Bryston B-60 SST Integrated Amplifier
Bryston B-60 SST Integrated Amplifier

... The Bryston B-60 Integrated Amplifier is without question one of the most sonically transparent and reliable audio products available. It offers performance levels equal to the finest separate audio components. The B-60 provides 60 watts per channel at 8 ohms and 100 watts ...
< 1 ... 1112 1113 1114 1115 1116 1117 1118 1119 1120 ... 1315 >

Variable-frequency drive



A variable-frequency drive (VFD) (also termed adjustable-frequency drive, variable-speed drive, AC drive, micro drive or inverter drive) is a type of adjustable-speed drive used in electro-mechanical drive systems to control AC motor speed and torque by varying motor input frequency and voltage.VFDs are used in applications ranging from small appliances to the largest of mine mill drives and compressors. However, around 25% of the world's electrical energy is consumed by electric motors in industrial applications, which are especially conducive for energy savings using VFDs in centrifugal load service, and VFDs' global market penetration for all applications is still relatively small. That lack of penetration highlights significant energy efficiency improvement opportunities for retrofitted and new VFD installations.Over the last four decades, power electronics technology has reduced VFD cost and size and has improved performance through advances in semiconductor switching devices, drive topologies, simulation and control techniques, and control hardware and software.VFDs are available in a number of different low- and medium-voltage AC-AC and DC-AC topologies.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report