Constant Voltage Power Supply , Constant Current Mode
... For example you can set the current limiting value to 1.5 amp , and the power supply will go into CC mode when the output current is more than 1.5 amp. And the power supply will give a constant current of 1.5Amp to the load usually with a voltage lower than the voltage at CV (constant voltage )mode ...
... For example you can set the current limiting value to 1.5 amp , and the power supply will go into CC mode when the output current is more than 1.5 amp. And the power supply will give a constant current of 1.5Amp to the load usually with a voltage lower than the voltage at CV (constant voltage )mode ...
specification sheet for Problem 1B
... The PQ12 –P actuators can be used as a linear servo by connecting the actuator to a microcontroller such as the CIB control board offered by Firgelli. This control board reads the position signal from the PQ12, compares it with your input control signal then command ...
... The PQ12 –P actuators can be used as a linear servo by connecting the actuator to a microcontroller such as the CIB control board offered by Firgelli. This control board reads the position signal from the PQ12, compares it with your input control signal then command ...
Design and Implementation of Carrier Based Sinusoidal PWM
... The dc-ac converter, also known as the inverter, converts dc power to ac power at desired output voltage and frequency. The dc power input to the inverter is obtained from an existing power supply network or from a rotating alternator through a rectifier or a battery, fuel cell, photovoltaic array o ...
... The dc-ac converter, also known as the inverter, converts dc power to ac power at desired output voltage and frequency. The dc power input to the inverter is obtained from an existing power supply network or from a rotating alternator through a rectifier or a battery, fuel cell, photovoltaic array o ...
english - KEK Concept GmbH
... provides 0.5A of DC output. ROHM's high-efficiency 6MHz synchronous stepdown switching regulator BU9000xGWZ utilizes an ultra-low current pulsefrequency modulation (PFM) mode and provides up to 1.0A of load current with an input voltage range from 4.0V to 5.5V. ...
... provides 0.5A of DC output. ROHM's high-efficiency 6MHz synchronous stepdown switching regulator BU9000xGWZ utilizes an ultra-low current pulsefrequency modulation (PFM) mode and provides up to 1.0A of load current with an input voltage range from 4.0V to 5.5V. ...
ioSelect DC to Frequency Isolating Signal Conditioner
... If, for example, the input represents a flow in gallons per hour, then the time integral of this flow signal (total count) will represent total gallons. The input of the UP475 can supply voltage for a 2-wire current loop, up to 20 V dc. There are two output choices, an npn open collector or a reed r ...
... If, for example, the input represents a flow in gallons per hour, then the time integral of this flow signal (total count) will represent total gallons. The input of the UP475 can supply voltage for a 2-wire current loop, up to 20 V dc. There are two output choices, an npn open collector or a reed r ...
ROBOTICS BASED HVDC TRANSMISSION LINE HARMONIC
... damping oscillations in power systems or in parallel HVAC lines. The advantages described above encourage the use of DC links for separating large power systems into several non synchronous parts. Harmonic control techniques In order to control the harmonic in this system there are many techniques c ...
... damping oscillations in power systems or in parallel HVAC lines. The advantages described above encourage the use of DC links for separating large power systems into several non synchronous parts. Harmonic control techniques In order to control the harmonic in this system there are many techniques c ...
6 position wall switch for 2-speed evaporative coolers to control high
... installing switch. The installer of this switch must be technically qualified for this type of installation. A qualified electrician should check all wiring and circuit breakers and be sure that the cooler installation is effectively grounded. ...
... installing switch. The installer of this switch must be technically qualified for this type of installation. A qualified electrician should check all wiring and circuit breakers and be sure that the cooler installation is effectively grounded. ...
DCPMU and Programmable Loads
... For Open Collector Output situations, look at the circuit in the device spec that is recommended for loading. The IOH value is ...
... For Open Collector Output situations, look at the circuit in the device spec that is recommended for loading. The IOH value is ...
L0446166
... DIRECT torque control (DTC) of induction motors has gained popularity in industrial applications mainly due to its simple control structure from its first introduction in 1986 [1]. The speed of an induction motor depend on the frequency of the supply voltage 50Hz and the speed can only be controlled ...
... DIRECT torque control (DTC) of induction motors has gained popularity in industrial applications mainly due to its simple control structure from its first introduction in 1986 [1]. The speed of an induction motor depend on the frequency of the supply voltage 50Hz and the speed can only be controlled ...
Supply Voltage Drop on Fast Current Demand
... To avoid voltage losses the layout must be done with large trace for the Vin, Vout and ground. The output capacitors must be placed as close as possible to the voltage regulator output pin. To allow the same voltage reference for all circuits, the output connection from the output capacitor to the d ...
... To avoid voltage losses the layout must be done with large trace for the Vin, Vout and ground. The output capacitors must be placed as close as possible to the voltage regulator output pin. To allow the same voltage reference for all circuits, the output connection from the output capacitor to the d ...
XUPS-600-1000
... voltage regulation with surge protection and noise filtering, and also overvoltage protection with a threshold of 135 vac, and undervoltage protection with a threshold of 95 vac. Upon a brownout, overvoltage, or loss of power, the XUPs will transfer to battery power in less ...
... voltage regulation with surge protection and noise filtering, and also overvoltage protection with a threshold of 135 vac, and undervoltage protection with a threshold of 95 vac. Upon a brownout, overvoltage, or loss of power, the XUPs will transfer to battery power in less ...
induction motor* parameters extraction
... parameters, are to test motor under no-load and locked rotor conditions. FIRST NO-LOAD TEST The no-load test, like the open circuit test on a transformer, gives information about exciting current and rotational losses. The test is performed by applying balanced rated voltage on the stator windings a ...
... parameters, are to test motor under no-load and locked rotor conditions. FIRST NO-LOAD TEST The no-load test, like the open circuit test on a transformer, gives information about exciting current and rotational losses. The test is performed by applying balanced rated voltage on the stator windings a ...
Power Factor Correction Boost Controller
... efficiency as much as 5%. The LT8312 is suitable for universal AC (90–265VAC) input and higher ranges, depending on the choice of external components. The LT8312 uses hysteretic start-up, eliminating the need for a bias power supply. After start-up the device is powered by a bootstrap winding off of ...
... efficiency as much as 5%. The LT8312 is suitable for universal AC (90–265VAC) input and higher ranges, depending on the choice of external components. The LT8312 uses hysteretic start-up, eliminating the need for a bias power supply. After start-up the device is powered by a bootstrap winding off of ...
VIBRATION OF AC INDUCTION ELECTRIC MOTORS
... The rotor laminations are skewed to provide smoother torque The rotor does not quite keep up with the rotating magnetic field of the stator, however. It falls behind or slips as the field rotates. Motor slip is necessary for so that the shaft can supply useful torque. Another type of AC induction mo ...
... The rotor laminations are skewed to provide smoother torque The rotor does not quite keep up with the rotating magnetic field of the stator, however. It falls behind or slips as the field rotates. Motor slip is necessary for so that the shaft can supply useful torque. Another type of AC induction mo ...
Why a Mini Inverter?
... A modified sine wave (sometimes referred to as a “simulated” sine wave is an AC current that is not a pure sine wave. Modified sine waves have some load limitations in regards to electronic equipment. Lighting loads, however, are typically unaffected by modified sine wave current (see note at the bo ...
... A modified sine wave (sometimes referred to as a “simulated” sine wave is an AC current that is not a pure sine wave. Modified sine waves have some load limitations in regards to electronic equipment. Lighting loads, however, are typically unaffected by modified sine wave current (see note at the bo ...
EPAD® Technology (Electrically Programmable Analog Device)
... set voltage and current levels are stored indefinitely inside the device, even with power removed. Unlike microcontroller-based trimming, the EPAD requires no additional active circuitry, a tiny fraction of the power, and far less board space. The entire EPAD programming system consists of the EPAD ...
... set voltage and current levels are stored indefinitely inside the device, even with power removed. Unlike microcontroller-based trimming, the EPAD requires no additional active circuitry, a tiny fraction of the power, and far less board space. The entire EPAD programming system consists of the EPAD ...
Variable-frequency drive

A variable-frequency drive (VFD) (also termed adjustable-frequency drive, variable-speed drive, AC drive, micro drive or inverter drive) is a type of adjustable-speed drive used in electro-mechanical drive systems to control AC motor speed and torque by varying motor input frequency and voltage.VFDs are used in applications ranging from small appliances to the largest of mine mill drives and compressors. However, around 25% of the world's electrical energy is consumed by electric motors in industrial applications, which are especially conducive for energy savings using VFDs in centrifugal load service, and VFDs' global market penetration for all applications is still relatively small. That lack of penetration highlights significant energy efficiency improvement opportunities for retrofitted and new VFD installations.Over the last four decades, power electronics technology has reduced VFD cost and size and has improved performance through advances in semiconductor switching devices, drive topologies, simulation and control techniques, and control hardware and software.VFDs are available in a number of different low- and medium-voltage AC-AC and DC-AC topologies.