• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
373 ELR Earth Leakage Relay Specifications
373 ELR Earth Leakage Relay Specifications

VLSI Iterative Decoder Design
VLSI Iterative Decoder Design

... Objective and Background of the Presentation CMOS Power Dissipation CMOS Device Characteristics CMOS Current Mirror Design of Level Shifter through Mirror Circuit Circuit Simulation Delay and Power Analysis Leakage Analysis Comparison Analysis Summary and Discussion ...
Local area network (LAN) packet switch remote power system
Local area network (LAN) packet switch remote power system

... closed system is shoWn. An external AC source 50 (110/ 120v) is connected to an external poWer supply 52. External poWer supply 52 provides appliance poWer at 48v via poWer bus 70, Which may, for example, consist of tWisted pair or any other suitable connection. As further shoWn in FIG. 4, the LAN S ...
Practical Methods for Verifying Removal of Trojan Stable Operating
Practical Methods for Verifying Removal of Trojan Stable Operating

... It is well known that many useful circuits are plagued by the presence of undesired equilibrium (operating) points and that these Trojan equilibrium points must be eliminated with Trojan State Elimination (TSE) circuits for proper circuit operation. Self-stabilized bias generators, voltage and curre ...
Digital Systems: Combinational Logic Circuits
Digital Systems: Combinational Logic Circuits

... Advanced-performance CMOS, not pin but electrically compatible with TTL ...
CableServ CHAS Headend Amplifier System
CableServ CHAS Headend Amplifier System

... Product specifications are available for the following models which are produced in Power Doubled (PHD), PushPull (PP) and Gallium Arsenide (GaAs) technologies. Models are single (S) or dual (D) stage hybrid with specified bandwidth, technology and gain (dB) including 0 dB Isolation (I). ...
8W-01 WIRING DIAGRAM INFORMATION
8W-01 WIRING DIAGRAM INFORMATION

... DEVICES All ESD sensitive components are solid state and a symbol is used to indicate this. When handling any component with this symbol, comply with the following procedures to reduce the possibility of electrostatic charge build up on the body and inadvertent discharge into the component. If it is ...
Installation Guide, Serial Interface T942SI, TD90927gb.fm
Installation Guide, Serial Interface T942SI, TD90927gb.fm

WIRING DIAGRAM INFORMATION
WIRING DIAGRAM INFORMATION

Lifeway II Series Single Phase C UPS User Manual
Lifeway II Series Single Phase C UPS User Manual

... based DC to AC power inverter utilizing IGBT technology. It integrates a fully automatic 3rate battery charger, a solid-state transfer system, control circuitry, self testing and recording digital meter display, and maintenance free sealed lead calcium type batteries. The system components are caref ...
PDF Reference Designs
PDF Reference Designs

... sensor. A basic proximity sensor includes a receiver and a transmitter, each of which consists of metal traces formed on layers of a PCB. The AD7745 has an on-chip excitation source, which connects to the transmitter trace of the sensor. An electric field is generated between the receiver and the tr ...
ESD Protection Design & Qualification Challenges
ESD Protection Design & Qualification Challenges

... board) along with the different stress current wave shapes for the two tests, it is not surprising that they would lack correlation. • However when external pins are involved, a higher component level ESD on these pins could mean less load for the on-board clamp to handle. But this type of approach, ...
Simulation of AC Electrical Machines Behaviour Using Discrete
Simulation of AC Electrical Machines Behaviour Using Discrete

... software have been tested for this purpose. The result of this extended research is that many of these packages have their own power systems library inside. However, the approach used is always the same since the electrical machine has to be considered as a continuous system which has to be discreti ...
electric rewind installation instructions (h-8823)
electric rewind installation instructions (h-8823)

... installed and wired. 2. Charge the hose before winding it on the reel. This will protect the drum from excessive pressure. 3. If reel has flanged outlet riser: Remove the entire riser from the hub. Be careful not to damage the gasket. Apply thread compound to all threads and bushings. Thread the hos ...
Test products for power systems from Megger.
Test products for power systems from Megger.

MAX9621EVKIT.pdf
MAX9621EVKIT.pdf

... to 18V DC power supply connected between VBAT and GND. Jumpers JU2 and JU3 can be utilized to emulate a short-to-VBAT, a short-to-GND Hall output, or an open condition. See the S1/S2 Hall-Effect Sensors and External-User Sensor Evaluation section for more information. During the emulation of a short ...
technical note - Digi-Key
technical note - Digi-Key

... OK International (Oki &Metcal branded) soldering systems offer superior EOS/ESD protection. Because our soldering systems deliver continuous current, they cannot generate switching transients. Typical values for tip-to-ground resistance and tip potential are 0.8 ohms and 1.0mV RMS, well within the M ...
Aalborg Universitet Han, B.M. ; Nho, E.C.
Aalborg Universitet Han, B.M. ; Nho, E.C.

... The HVDC power converter operates in extremely high-voltage and high power condition. So, many thyristor are connected in series to comprise one valve in the power converter. The normal or abnormal operations of power converter should be tested before it is commissioned on site. A huge test facility ...
Analogue Differential Inputs - Rockwell Automation Knowledgebase
Analogue Differential Inputs - Rockwell Automation Knowledgebase

ha0220T_7_LD_Scanning Galvo System.fm
ha0220T_7_LD_Scanning Galvo System.fm

... The Scanner Position and Internal Command signals are scaled internally by the driver circuit and are essentially equivalent to the input signal /2. Positioning Error x 5 - This signal is proportional to the difference between the demanded and the actual positions - (Position - Command) x 5 (i.e. (P ...
2001 Power Plus Revs
2001 Power Plus Revs

... arc shutdown so less energy from the source is sent to the ESP during arcing. In addition, the Series requires less transformer fluid, reducing containment problems. The chance of fluid ignition is also reduced due to the high speed of its Insulated Gate Bipolar Transistor (IGBT) control devices and ...
8.0 ELECTRIC POWER
8.0 ELECTRIC POWER

... The U.S. EPR FSAR includes the following COL Item in Section 8.2.1.1: A COL applicant that references the U.S. EPR design certification will provide site-specific information regarding the offsite transmission system and connections to the station switchyard. This COL Item is addressed as follows: { ...
uojcourses.awardspace.com
uojcourses.awardspace.com

... Note: The equations seen above are for the transistor, not the circuit. ...
8.0 ELECTRIC POWER
8.0 ELECTRIC POWER

... The U.S. EPR FSAR includes the following COL Item in Section 8.2.1.1: A COL applicant that references the U.S. EPR design certification will provide site -specific information regarding the offsite transmission system and connections to the station switchyard. This COL Item is addressed as follows: ...
Chapter 12 Machine and System Control
Chapter 12 Machine and System Control

...  This step includes communications, Internal Diagnostics, etc. ...
< 1 ... 79 80 81 82 83 84 85 86 87 ... 256 >

Fault tolerance



Fault tolerance is the property that enables a system to continue operating properly in the event of the failure of (or one or more faults within) some of its components. If its operating quality decreases at all, the decrease is proportional to the severity of the failure, as compared to a naively designed system in which even a small failure can cause total breakdown. Fault tolerance is particularly sought after in high-availability or life-critical systems.A fault-tolerant design enables a system to continue its intended operation, possibly at a reduced level, rather than failing completely, when some part of the system fails. The term is most commonly used to describe computer systems designed to continue more or less fully operational with, perhaps, a reduction in throughput or an increase in response time in the event of some partial failure. That is, the system as a whole is not stopped due to problems either in the hardware or the software. An example in another field is a motor vehicle designed so it will continue to be drivable if one of the tires is punctured. A structure is able to retain its integrity in the presence of damage due to causes such as fatigue, corrosion, manufacturing flaws, or impact.Within the scope of an individual system, fault tolerance can be achieved by anticipating exceptional conditions and building the system to cope with them, and, in general, aiming for self-stabilization so that the system converges towards an error-free state. However, if the consequences of a system failure are catastrophic, or the cost of making it sufficiently reliable is very high, a better solution may be to use some form of duplication. In any case, if the consequence of a system failure is so catastrophic, the system must be able to use reversion to fall back to a safe mode. This is similar to roll-back recovery but can be a human action if humans are present in the loop.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report