BDTIC www.BDTIC.com/infineon Wireless Components ASK Single Conversion Receiver
... As can be seen from the block diagram in Figure 2-1, the basic concept of the TDA5200 is a single conversion receiver with an on-chip fully integrated PLL frequency synthesizer and an IF of nominal 10.7MHz. The 10.7MHz IF was selected because of the availability of low-cost ceramic filters in a vari ...
... As can be seen from the block diagram in Figure 2-1, the basic concept of the TDA5200 is a single conversion receiver with an on-chip fully integrated PLL frequency synthesizer and an IF of nominal 10.7MHz. The 10.7MHz IF was selected because of the availability of low-cost ceramic filters in a vari ...
Stakeholder Comparison Comment Rationale Matrix 2010-07-15 AESO AUTHORITATIVE DOCUMENT PROCESS
... NOTE: The AESO is asking market participants to give an initial indication of their support for, or opposition to, the specific Alberta Reliability Standard variances to the NERC requirements referenced below. Such an initial indication assists in the AESO’s practical understanding of the receptivit ...
... NOTE: The AESO is asking market participants to give an initial indication of their support for, or opposition to, the specific Alberta Reliability Standard variances to the NERC requirements referenced below. Such an initial indication assists in the AESO’s practical understanding of the receptivit ...
Model Paper for LACCEI Proceedings
... simulation platforms; PSpice and MultiSim, and as a supplement how this in turn relates to higher level abstraction languages such as VHDL. It was shown in examples above that both perform at a high level in terms of ease of use, clear and concise displays and corresponding result outcomes. While ma ...
... simulation platforms; PSpice and MultiSim, and as a supplement how this in turn relates to higher level abstraction languages such as VHDL. It was shown in examples above that both perform at a high level in terms of ease of use, clear and concise displays and corresponding result outcomes. While ma ...
elg7186_15power - School of Electrical Engineering and
... • If a processor uses a single supply voltage V and completes a task T just at its deadline, then V is the unique supply voltage which minimizes the energy consumption of T. • If a processor can only use a number of discrete voltage levels, then a voltage schedule with at most two voltages minimizes ...
... • If a processor uses a single supply voltage V and completes a task T just at its deadline, then V is the unique supply voltage which minimizes the energy consumption of T. • If a processor can only use a number of discrete voltage levels, then a voltage schedule with at most two voltages minimizes ...
IGC193T120T8RM IGBT4 Medium Power Chip
... Due to technical requirements, components may contain dangerous substances. For information on the types in question, please contact the nearest Infineon Technologies Office. The Infineon Technologies component described in this Data Sheet may be used in life-support devices or systems and/or automo ...
... Due to technical requirements, components may contain dangerous substances. For information on the types in question, please contact the nearest Infineon Technologies Office. The Infineon Technologies component described in this Data Sheet may be used in life-support devices or systems and/or automo ...
Activity: A Peizoelectric Smart Sensor
... We will use the term “Smart Sensor” to refer to systems that employs a sensor device mated to microelectronics. In this activity we will use metal coated PVDF films as our sensor system and a computer will take the place of the microelectronics. The system used in this activity is not engineered to ...
... We will use the term “Smart Sensor” to refer to systems that employs a sensor device mated to microelectronics. In this activity we will use metal coated PVDF films as our sensor system and a computer will take the place of the microelectronics. The system used in this activity is not engineered to ...
Augmentation Protection
... they will not operate for plant loading levels up to at least those shown in Table A-2. TNSP must ensure that protection and control systems and settings are implemented such that they will not operate for voltage conditions that the plant must ride through. These voltage conditions are set out in T ...
... they will not operate for plant loading levels up to at least those shown in Table A-2. TNSP must ensure that protection and control systems and settings are implemented such that they will not operate for voltage conditions that the plant must ride through. These voltage conditions are set out in T ...
MAX16128/MAX16129 Evaluate: MAX16128/MAX16129 Evaluation Kits General Description
... The MAX16128/MAX16129 evaluation kits (EV kits) demonstrate high overvoltage protection of the MAX16128/ MAX16129 for automotive applications that must survive load-dump and high-voltage transient conditions. The fully assembled and tested surface-mount EV kit board provides two circuits: One full-f ...
... The MAX16128/MAX16129 evaluation kits (EV kits) demonstrate high overvoltage protection of the MAX16128/ MAX16129 for automotive applications that must survive load-dump and high-voltage transient conditions. The fully assembled and tested surface-mount EV kit board provides two circuits: One full-f ...
Automating amplifier circuit design
... applications using TI components. To minimize the risks associated with Buyers’ products and applications, Buyers should provide adequate design and operating safeguards. TI does not warrant or represent that any license, either express or implied, is granted under any patent right, copyright, mask ...
... applications using TI components. To minimize the risks associated with Buyers’ products and applications, Buyers should provide adequate design and operating safeguards. TI does not warrant or represent that any license, either express or implied, is granted under any patent right, copyright, mask ...
Circuit Breakers - Selective Coordination
... 1. Overload Region: The opening of a molded case circuit breaker in the overload region is generally accomplished by a thermal element, while a magnetic coil is generally used on power breakers. Electronic sensing breakers will utilize CTs. As can be seen, the overload region has a wide tolerance ba ...
... 1. Overload Region: The opening of a molded case circuit breaker in the overload region is generally accomplished by a thermal element, while a magnetic coil is generally used on power breakers. Electronic sensing breakers will utilize CTs. As can be seen, the overload region has a wide tolerance ba ...
5.4.016 Cartridge Solenoid Valves.qxd - NOR
... These products are intended for use in industrial compressed air systems only. Do not use these products where pressures and temperatures can exceed those listed under ‘Technical Data’. Before using these products with fluids other than those specified, for non-industrial applications, life-support ...
... These products are intended for use in industrial compressed air systems only. Do not use these products where pressures and temperatures can exceed those listed under ‘Technical Data’. Before using these products with fluids other than those specified, for non-industrial applications, life-support ...
Full-Text PDF
... made by modern distance relays in less than one cycle. However, the operating time of the relay and its give the distance of fault location are not the only factor to be considered while selecting a distance protection for a transmission line that requires dynamic loading but also the loading of tra ...
... made by modern distance relays in less than one cycle. However, the operating time of the relay and its give the distance of fault location are not the only factor to be considered while selecting a distance protection for a transmission line that requires dynamic loading but also the loading of tra ...
Lecture 7: High-level power reduction and management
... Duplicate part of logic to precompute circuit output values one cycle before they are required Use these values to reduce the total amount of switching in the circuit in the next cycle ...
... Duplicate part of logic to precompute circuit output values one cycle before they are required Use these values to reduce the total amount of switching in the circuit in the next cycle ...
RARF Workshop_NPRR425
... aggregation does not reduce ERCOT’s ability to model pre- and post-contingency conditions.” If: – The mix of wind turbine models and sizes causes no degradation in the dynamic performance – The mix of wind turbines are included in the Resource asset registration information submitted for the WGR; – ...
... aggregation does not reduce ERCOT’s ability to model pre- and post-contingency conditions.” If: – The mix of wind turbine models and sizes causes no degradation in the dynamic performance – The mix of wind turbines are included in the Resource asset registration information submitted for the WGR; – ...
Elmas Soyak - Department Of | Electrical And Electronics Engineering
... I have performed my summer practice in TAI-TUSAŞ (Turkish Aerospace IndustriesTürkiye Uzay ve Havacılık Anonim Şirketi). It is the center of technology in design, development, manufacture, integration of aerospace systems, modernization and after sales support in Turkey. My internship lasted 20 days ...
... I have performed my summer practice in TAI-TUSAŞ (Turkish Aerospace IndustriesTürkiye Uzay ve Havacılık Anonim Şirketi). It is the center of technology in design, development, manufacture, integration of aerospace systems, modernization and after sales support in Turkey. My internship lasted 20 days ...
EX-30 - Panasonic Electric Works
... The EX-30 series solves all of the difficulties associated with fiber sensors, such as: • Difficulty finding a suitable place for the amplifier • Fragility of the fiber • Extra space needed because of difficulty in bending the fiber • The nuisance of having to use a protective tube to prevent fiber ...
... The EX-30 series solves all of the difficulties associated with fiber sensors, such as: • Difficulty finding a suitable place for the amplifier • Fragility of the fiber • Extra space needed because of difficulty in bending the fiber • The nuisance of having to use a protective tube to prevent fiber ...
... On the side of possible victims, special attention shall be given to control and protection systems as well as security and safety systems (including communication and navigation systems). As these systems depend for their function on low energy signals they can be sensitive to electromagnetic pheno ...
CMOS_ch1.12_z-A Circuit Design Example
... • Thus, the nMOS net may consist of nested series-parallel, connections of nMOS transistors between the output node and the ground. Introduction to VLSI Design – Lec01. ...
... • Thus, the nMOS net may consist of nested series-parallel, connections of nMOS transistors between the output node and the ground. Introduction to VLSI Design – Lec01. ...
Fault tolerance
Fault tolerance is the property that enables a system to continue operating properly in the event of the failure of (or one or more faults within) some of its components. If its operating quality decreases at all, the decrease is proportional to the severity of the failure, as compared to a naively designed system in which even a small failure can cause total breakdown. Fault tolerance is particularly sought after in high-availability or life-critical systems.A fault-tolerant design enables a system to continue its intended operation, possibly at a reduced level, rather than failing completely, when some part of the system fails. The term is most commonly used to describe computer systems designed to continue more or less fully operational with, perhaps, a reduction in throughput or an increase in response time in the event of some partial failure. That is, the system as a whole is not stopped due to problems either in the hardware or the software. An example in another field is a motor vehicle designed so it will continue to be drivable if one of the tires is punctured. A structure is able to retain its integrity in the presence of damage due to causes such as fatigue, corrosion, manufacturing flaws, or impact.Within the scope of an individual system, fault tolerance can be achieved by anticipating exceptional conditions and building the system to cope with them, and, in general, aiming for self-stabilization so that the system converges towards an error-free state. However, if the consequences of a system failure are catastrophic, or the cost of making it sufficiently reliable is very high, a better solution may be to use some form of duplication. In any case, if the consequence of a system failure is so catastrophic, the system must be able to use reversion to fall back to a safe mode. This is similar to roll-back recovery but can be a human action if humans are present in the loop.