Download 39904620

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

History of electric power transmission wikipedia , lookup

Buck converter wikipedia , lookup

Chirp compression wikipedia , lookup

Electromagnetic compatibility wikipedia , lookup

Islanding wikipedia , lookup

Spectral density wikipedia , lookup

Mathematics of radio engineering wikipedia , lookup

Heterodyne wikipedia , lookup

Public address system wikipedia , lookup

Alternating current wikipedia , lookup

Mains electricity wikipedia , lookup

Distribution management system wikipedia , lookup

Chirp spectrum wikipedia , lookup

Last mile wikipedia , lookup

Telecommunications engineering wikipedia , lookup

Ringing artifacts wikipedia , lookup

Transcript
COMMITTEE T1 – TELECOMMUNICATIONS
Working Group T1E1.4 (DSL Access)
Arlington, VA; April 20 - 23 1999
T1E1.4/99-183
CONTRIBUTION
TITLE:
Non-Continuous Events in the Telephone Outside Plant
SOURCE*:
AG Communication Systems/Lucent
PROJECT:
T1E1.4, Spectral Compatibility
_______________________________
ABSTRACT
Some recent submissions1, 2 to T1E1.4 suggest that non-continuous events, such as power
variances, can be detrimental to services shared within the binder. This contribution
characterizes three ubiquitous, non-continuous Plain Old Telephone Service (POTS) events:
ringing, supervision, and dial pulse in order to illustrate that intra-binder interference in DSL
frequency bands has been present for decades in the Public Switched Telephone Network
(PSTN). These normal events represent cross talk impairments of changing magnitude, which
are more severe than the classes currently under consideration for the Spectral Management
standard.
_______________________________
1.
INTRODUCTION
The discussion examines three common, non-continuous POTS events, with some supporting
test measurements, which are known to couple into DSL frequencies on adjacent pairs.
2.
DISCUSSION
2.1. Ringing
Ringing in North America is an AC voltage superimposed on a DC bias. The majority of
installations in the US use non-sinusoidal 20 Hz ringing with a nominal rms. 90 volts at the
ringing source. A significant number of telephone installations in North America use other
frequencies that range from 16 2/3 to 66 2/3 with voltages from 85 to 1353. One ANSI standard
sets the maximum voltage limit to 150V rms4 and notes cases where it can attain 175V rms.
Ringing is clearly a non-continuous disturber. At the beginning of each ringing burst there is a
transition from -48-Volt battery feed to -48-Volt with superimposed AC ringing. Nominal
NOTICE
This document has been prepared to assist Accredited Standards Committee T1-Telecommunications. This document is offered
to the Committee as a basis for discussion and is not a binding proposal on AG Communication Systems or any other company.
The content is subject to change in form and numerical value after more study. AG Communication Systems specifically reserves
the right to add to, amend, or withdraw the statements contained herein.
* CONTACT: Randy Brown; email: [email protected]; Tel: 602-581-4125; Fax: 602-582-7111
Non-Continuous Events In the Telephone Outside Plant
T1E1.4 Spectral Management
interrupts are 2 seconds on and 4 seconds off. Custom ringing cadences with multiple ringing,
such as triple cadences, are common. The ringing waveform is ideally a sine wave with its axis
of symmetry shifted -48-Volts from zero. The ringing burst can be characterized in terms of
100's of milliseconds as shown in Figure 1. In this depiction, the sine wave starts and stops in
unity with the DC bias and represents the best case relative to instantaneous power changes as a
result of ring application and trip.
-138 V
nominal peak
90 Vac rms.
4200 mS
1800 mS
Figure 1. Standard Ringing Potential with Best Case Start/End
Elements of synchronization are related to the application of ringing in many applications, such
as the use of a common ringing bus serving hundreds of lines. Central office implementations, in
many cases, simultaneously ring multiple lines with concurrent cadence. As such, the application
and withdraw of ringing is generally without regard to the phase angle of AC energy. The peak
voltage when ringing is tripped can be the sum of the DC and greatest AC or approximately 170
volts as shown in Figure 2.
20Hz or 50 mS Peak to Peak
~170V worst case
- 90Vrms ac
2
- 48Vdc
0
+ 48Vdc
Figure 2. Standard Ringing Potential Worst Case Start/End
AG Communication Systems
Page 2 of 8
06/27/17
Non-Continuous Events In the Telephone Outside Plant
T1E1.4 Spectral Management
Ringing is not balanced within the pair as it is ordinarily applied on only the ring conductor of
the telephone pair, while the tip conductor is held near earth ground. The unbalanced application
of ringing increases the pair-to-pair coupling within the binder group.
In practice, multi-vibrators generate the wave shape of the ringing energy. To smooth the
resulting wave edge, post filtering is applied to the generated waveform. The ringing interrupters
switch from the AC and DC ringing potentials to a DC-only potential during the silent interval as
illustrated in Figure 3. This switching is not synchronized with the ringing waveform.
DC
Bias
DC
Source
-48Vdc
Fuse
Line Frame
Interruption
Time i, i+2...
F
i
138 V l
-48Vdc
nominal
peak to peak t
e Ringing Bus
r
Driver
Transistor
Time i+1...
-48Vdc
Figure 3. Basic Ringing Generator
In its worst case, a generated ringing waveform is a trapezoidal shape, which means it has higher
frequency components occurring at 25 mS intervals. Transient energies often result from gap
switching in the ringing generator as shown in Figure 4.
The phase at the transition edge of ringing can be > 500Hz
infinity
Time i+2
Time i
< .5 mS
25 mS
Time i+1
1 mS
Figure 4. Ringing Waveforms (Worst Case Generalization)
AG Communication Systems
Page 3 of 8
06/27/17
Non-Continuous Events In the Telephone Outside Plant
T1E1.4 Spectral Management
A square waveform is made of a fundamental frequency f and all the odd harmonics rising to
infinity, that is, 3f, 5f, 7f and so on. As a ringing waveform nears a square or trapezoidal shape
together with its instantaneous application on a line, it can be expected to produce fundamental
harmonics across a wide array of frequencies. This was observed using a spectrum analyzer
sampling distinctive ringing frequencies at 3kHz for approximately 10 minutes, on a copper pair
with 135 Ohms termination impedance adjacent to a continually ringing line, within a binder of
10Kft 24AWG, for the upstream ADSL bandpass as shown in figure 5:
-58.6 dBm
-90 dBm
noise floor
Max ADSL
Upstream
Transmit
Power
-34.5 dBm5
Figure 5. Ringing Impulse Noise within the ADSL Upstream Bandpass
With the noise floor shown of approximately -90dBm along with a peak ringing amplitude of
about -58dBm, its clear that over 30dBm of ringing impulse noise within the frequencies of
interest to the spectral management project is not unusual. This effect of ringing was also
observed on various lengths of copper, with randomly selected pairs across a wide array of
frequencies using ringing generators, line circuits and ringing cards in current commercial service
as described in appendix A.
Various forms of ringing cadence exist as noted above such as "triple," "double," "long/short,"
"coded," and "teen ringing.6" For example, triple ringing bursts three times within 1800 mS as
shown in Figure 6. These have the effect of increasing random, ring application and removal
impulse effects as shown above. Plainly, one line alone ringing within a binder can represent a
significant non-continuous disturber, which all DSL systems must accommodate.
1800 mS
Figure 6. Triple Ringing Interval
AG Communication Systems
Page 4 of 8
06/27/17
Non-Continuous Events In the Telephone Outside Plant
T1E1.4 Spectral Management
Telephone Switching systems typically have the capability of ringing as many as one-fourth of
the connected lines. Accordingly, in the worst case, an average of 6 of the 25 pairs in a binder
group could be in some phase of ringing application or removal.
2.2. Supervision (hook flash)
As shown in Figure 7, the DC potential is applied to the customer loop through a battery-feed
device consisting of two inductive coils in series with tip and ring. An idle circuit is nominally 48
Volts with no current flowing.
48Vdc
Figure 7. Simple Battery Feed Arrangement
During service initiation, the customer closes the loop and a transient voltage migration occurs
within the cable pair of greater than 40 volts, that is, it drops to 6 volts across the telephone set.
A sudden voltage change in the presence of distributed capacitance can couple as not all of it gets
cancelled out. A wave front of the sudden change in loop voltage is unbounded and currently
unrestricted. In a theoretical situation with a short customer loop and no capacative leak between
tip and ring conductors, the instantaneous peak-to-peak value of these potentials can reach 2,000
volts due to the inductive reactance of the battery feed device. POTS filters for DSL are only on
the pair connected to and adjacent pairs are susceptible to the type of inductive kick as described
above. This exists throughout the network today.
AG Communication Systems
Page 5 of 8
06/27/17
Non-Continuous Events In the Telephone Outside Plant
T1E1.4 Spectral Management
In some cases, on longer loops, the voltage is boosted in order to achieve objective currents while
the telephone is off hook. Therefore, 48 volts is the minimum of voltage change that may be
encountered. This effect was observed on a spectrum analyzer lab setting as described above for
ringing with the collector located at the premise side as shown in Figure 8.
-80dBm
-90dBm
Figure 8. Hook Switch Coupling
2.3. Dial Pulse
These are periodic transitions from on-hook to off-hook in order to convey numeric values
typically at 10 pulses per second in North America. Usually, 40 ms make (close) versus 60 ms
break (open) as there is less time required to build the magnetic flux versus lose it. As soon as
the dial on the phone is turned, all of the resistance in the circuit (all the handset circuitry) is
shunted. There is a solid short in the circuit in order to get ready to go to maximum current.
The shorter the loop the higher the current but the less the cross talk potential. This is just the
opposite of longer loops. These phenomena exist on short and longer loops. The highest value is
a zero (10 pulses). The random, reoccurring cross talk effects of dial pulse were observed on a
spectrum analyzer with a lab setting as described above for supervision signaling with the
collector located at the premise side as shown in Figure 9. In some jurisdictions, all telephone
lines must support dial-pulse digit collection methods.
-74dBm
-90dBm
Figure 9. Dial Pulse Coupling
3.
CONCLUSION
These conditions co-exist with ISDN today. Therefore, ringing, hook flash and dial pulse noncontinuous characteristics exemplify tolerable interferers. Accordingly, services that are
frequency bounded and current limited in order to conform to service classes within the spectral
management project should be permitted independent of their temporal characteristics.
References:
[1] T1E1.4/99-103, "Stationarity and Time-Domain Specifications for Spectrum Management", Bellcore,
March 11, 1999, Costa Mesa, California;
[2] J. Stiscia and D. Johnson, "Selected Measurements of Non-Stationary and Stationary Crosstalk
Effects Upon FDM ADSL," T1E1.4/99-040, February 1, 1999.
[3] GTE Customer Handbook - 500, Issue 1, 1972
AG Communication Systems
Page 6 of 8
06/27/17
Non-Continuous Events In the Telephone Outside Plant
T1E1.4 Spectral Management
[4] T1.401-1993, "Interface Between Carriers and Customer Installations--Analog Voicegrade Switched
Access Lines Using Loop-Start and Ground-Start Signaling."
[5] T1.413-1998, " Network and Customer Installation Interfaces - Asymmetric Digital Subscriber Line
(ADSL) Metallic Interface."
[6] ANSI T1.401.02-1995, "Interface between Carriers and Customer Installations--Analog Voicegrade
Switched Access Lines with Distinctive Alerting Features."
[7] Federal Communications Commission Rules and Regulations, Code of Federal Regulations Title 47:
Part 68 - Connection of Telephone Equipment To The Network
AG Communication Systems
Page 7 of 8
06/27/17
Non-Continuous Events In the Telephone Outside Plant
T1E1.4 Spectral Management
Appendix A - Ringing Loop Simulation Setup & Testing Results
Setup

Test method: Distinctive ringing on pair 1, read impulse noise on pair 2

3 kHz sampling frequency, 25kHz - 140kHz & 0-300kHz

135 Ohms termination impedance on pair 2

2524 (24 Gauge) SEALPIC-FSF SX08 98C cable

5REN load on pair 1 at premise during ringing tests

5 minutes collection for ringing, 1-2 minutes for dial pulse and supervision

Commercial Line Card & Ringing Generator in use today in major ILEC market

Measured at CO during ringing and premise during dial pulse and supervision
Results for 0-300kHz Ringing Sampling Frequency
Loop Length ft
Noise Floor dBm Highest Peak dBm
18,000
-89.6
-60.8
15,000
-90.0
-59.8
10,000
-90.0
-59.8
5,000
-89.0
-55.2
1,000
-89.0
-57.6
Coupling was noted across the frequencies of interest. 6dB variance was observed based on the
pair selected.
AG Communication Systems
Page 8 of 8
06/27/17