* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download Optical Instruments
Reflector sight wikipedia , lookup
Magnetic circular dichroism wikipedia , lookup
Optical coherence tomography wikipedia , lookup
Ultraviolet–visible spectroscopy wikipedia , lookup
Confocal microscopy wikipedia , lookup
Birefringence wikipedia , lookup
Nonlinear optics wikipedia , lookup
Astronomical spectroscopy wikipedia , lookup
Atmospheric optics wikipedia , lookup
Night vision device wikipedia , lookup
Dispersion staining wikipedia , lookup
Surface plasmon resonance microscopy wikipedia , lookup
Schneider Kreuznach wikipedia , lookup
Photon scanning microscopy wikipedia , lookup
Anti-reflective coating wikipedia , lookup
Interferometry wikipedia , lookup
Lens (optics) wikipedia , lookup
Reflecting telescope wikipedia , lookup
Nonimaging optics wikipedia , lookup
Optical telescope wikipedia , lookup
Retroreflector wikipedia , lookup
Chapter 4 : Optical Instruments M A M EL-Morsy Optical Instruments 1. PHOTOGRAPHIC CAMERA A photographic camera consists essentially of a convex lens, a light sensitive film or plate at the back and a focussing arrangement. There is an adjustable aperture known as diaphragm that permits different amounts of light to enter the camera. Fig. 4-1 The image is focussed on the plate or film by altering the distance of the lens from it. There is a shutter placed in the path of light and the time for which it is opened depends upon the brightness of the object, the sensitivity of the photographic emulsion, the focal length of the lens and the size of the stop (Fig. 4. 1). The diameter d of the stop is usually given as a fraction of the focal length f of the lens system and the ratio called the f-ratio or f-number. 90 focal length diameter of the stop is Chapter 4 : Optical Instruments M A M EL-Morsy Suppose the focal length of the lens is 11 cm and the diameter of the f 11 stop is 1 cm. Then the f-ratio or f-number is 11 and d . The diameters of the stop of a camera are usually marked so that the exposure time is doubled between each position e.g. f , 5.6 f , 8 f , 11 f , 16 f 22 Therefore, the f-ratios are 5.6, 8, 11, 16, 22 etc. and their squares are in the ratio of 1 : 2 : 4 : 8 : 16. Therefore, if the correct exposure for for 2. f is one second, then, 5 .6 f f it is 2 seconds and for it is 4 seconds and so on. 11 8 DEPTH OF FOCUS Depth of focus is the maximum distance by which the film in a camera may buckle (move forward or backward along the axis) without causing the blurring of the image. Fig. 4-2 91 Chapter 4 : Optical Instruments M A M EL-Morsy Let r be the radius of the exit pupil of the coaxial optical system (camera lens system) and P the point image (Fig, 4.2). When the film is moved forward by a distance xl, the ray passing through the point A on the circumference of the exit pupil E, cuts the plane passing through P1, and normal to the axis at the point B. When the film is moved backward by a distance x2, the ray passing through the point A cuts the plane passing through P2, and normal to the axis at the point C. The location of the paint P2 is such that x1= x2. P1B=P2C=R s PP1B and POA are similar P1 B PP1 OA OP or R x1 r x x1 But, Rx r x2=x1. Depth of focus, P1P2 = x1 + x2 = 2 Rx r Determination of the depth of focus in a camera is of the great importance. It helps in estimating the amount by which the film in the camera may buckle without disturbing the image beyond the tolerable limit. 92 Chapter 4 : Optical Instruments M A M EL-Morsy 3. TELEPHOTO LENS To obtain an image of the object situated at a very long distance, a convex lens of large focal length should be used. In this case, to obtain a magnified image the distance between the lens and the photographic plate should be large. Thus a magnified image requires a long camera which may be unmanageable and inconvenient. To avoid this difficulty a telephoto lens is used. It consists of two lenses mounted in a tube. The tube is fixed in the camera in place of a single lens. One of the lenses is convex and the other is concave. Each lens is made achromatic (Fig. 4.3). Fig. 4-3 The concave lens L2 is placed in the original position of the lens in the camera, whereas the convex lens L1, is placed in the front of the lens L2. The combination of these two lenses acts as a single lens of large focal length. The combination acts as a convex lens. If fl and f2 are the focal lengths of the lenses L1 and L2 and is the distance between them, then 93 Chapter 4 : Optical Instruments M A M EL-Morsy 1 1 1 d f f1 f2 f1 f 2 Consider that the rays from the distant object after passing through the lens L1 meet at F1, but the lens L2 placed in the path diverges the rays and finally the rays meet at F2. The combination of lenses, L1 and L2 has formed the final image at F2 which can be formed by a single convex lens of focal length DF2 placed at D. Thus we find that the telephoto lens acts as a converging lens of large focal length. It also avoids the use of very long camera box and can be used for taking highly magnified images even with a small camera. 4. MICROSCOPES In the seventeenth century convex lenses were used as magnifying glasses. Afterwards two or more lenses were used to form powerful microscopes. In 1648, Hooke made use of microscopes in the study of existence of cells in animal and vegetable tissues. The angular magnification of a microscope in normal use is: M angle subtended at the eye by the image angle subtended at the unaided eye by the object placed at the near po int M 94 Chapter 4 : Optical Instruments M A M EL-Morsy 5. SIMPLE MICROSCOPE (MAGNIFYING GLASS) Suppose an object of length h is placed at the near point A and viewed by the eye. Then the visual angle is . tan h D (i) Fig. 4.4 Now suppose that a convex lens L of focal length f is used as a magnifying glass and the object AB is placed between O and F, such that the magnified erect image PQ is formed. If the observer's eye is close to the lens, then the distance OP is equal to the least distance of distinct vision. Here the visual angle is given by: tan PQ D Dividing (ii) by (i), 95 (ii) Chapter 4 : Optical Instruments M A M EL-Morsy tan PQ tan h PQ h or (for small angles) PQ v D h u u But, If M is the magnifying power M D u M D u 1 1 1 v u f Here, v = -D, and u is also negative 1 1 1 D u f 1 i.e. D D u f D D 1 u f M 1 D f 6. VIRTUAL IMAGE AT INFINITY When an object is placed at the focus of the lens the image is, formed at infinity (Fig. 4.5). 96 Chapter 4 : Optical Instruments M A M EL-Morsy Fig. 4.5 Then, linear magnification The visual angle PQ h is infinite, h f h f M h D Example 4.1 D M f A convex lens of focal length 10 cm is used as a magnifying glass. Find the magnifying power when (i) the image is formed at infinity and (ii) the image is formed at the least distance of distinct vision (25 cm from the lens). The Answer: (i) When the image in formed at infinity M D 25 2.5 f 10 (ii) When the image is formed at the near point M D 25 1 1 f 10 = 3.5 Example 4.2 A person has his near point at 15 cm and a range of distinct vision of 85 cm. What is his range of distinct vision when he wears close fitting spectacles having a power of -0.8 diopter ? The Answer: 97 Chapter 4 : Optical Instruments M A M EL-Morsy Power = -0,8 diopter f = metre = -125 cm In the first case, let the near point using spectacles be at a distance of ul cm from the eye. Here, v = -15 cm 1 1 1 v u1 f u1 =-17 cm 1 1 1 15 u1 125 ( approximately) In the second case, let the far point using spectacles be at a distance of u2 cm from the eye. Here, v = -(15+85) =-100 cm 1 1 1 v u2 f u2 = -500 cm Hence the range of vision = - 500-17 cm. = - 483 cm. Example 4.3 The ratio of the magnifying power of a converging lens when it is used to throw an image at infinity is 1.20. (a) What is the distance of distinct vision for the eye if the focal length of the lens is 4.80 cm ?. 98 Chapter 4 : Optical Instruments M A M EL-Morsy (b) At what distance from the lens must an object be placed so that the image falls at the distance of distinct vision calculated in (a) ?. The Answer: D f 1 (a) Here D f 1.20 f 1 1.20 D But f = 4.80 cm 4 .8 D 0.20 D = = 24 cm The least distance of distinct vision is 24 cm. (b) Here, f = 4.80 cm. u = ? v = -24 cm. 1 1 1 v u2 f 1 1 1 24 u 4.8 u = -4 cm. The object is placed at a distance of 4 cm from the lens. 7. COMPOUND MCROSCOPE 99 Chapter 4 : Optical Instruments M A M EL-Morsy The magnifying power of a simple microscope can be increased D M 1 by decreasing the focal length of the lens as f . But due to constructional difficulties, the focal length of a lens cannot be decreased beyond a certain limit. Moreover, the lens of small focal length has a small diameter because the curvature of the surface is large and the field of view is small. Therefore, to increase the magnifying power, two separate lenses are used. The lens near the object is called the objective and the other which is nearer the eye is known as the eyepiece. The objective and the eyepiece are both convex lenses. The objective is of small diameter and small focal length ( high power ) whereas the eyepiece is of large focal length than the objective. The object AB is placed at a distance slightly greater than the focal length of the objective (Fig. 4.6). An inverted image AB is formed at A. The eyepiece is adjusted so that the distance of A' from it is less than its focal length. As the eyepiece acts as a simple magnifying glass, the final image PQ is formed at P which is magnified and virtual. Magnifying Power When the microscope is in normal use, the final image PQ is formed at the ‘near point’ at a distance D from the eye. 100 Chapter 4 : Optical Instruments M A M EL-Morsy Fig. 4.6 M Angle subtended at the eye by the final image at D Angle subtended at the eye by the object at the same distance D PQ PQ M D AB AB D M PQ A B A B AB PQ M o Magnification of the eyepiece A B and A B M e Magnification of the objective AB M = Me x Mo As the eyepiece acts as a simple magnifying glass, its magnifying power = 1 D f Me 1 101 D fe Chapter 4 : Optical Instruments M A M EL-Morsy where fo is the focal length of the eyepiece. If the distance of the image AB from the objective = v and the distance of the image A B from the objective = v, and the distance of the object AB from the objective = u. Then, Mo Also 1 1 1 v u f v u (According to the sign convention u is –ve) 1 1 1 , v u fo Mo = v v ( 1) u fo v v ( 1) u fo M = Mo x Me M ( v D 1 )( 1 ) fo fe If the case of most of the microscopes the distance between the objective and the eyepiece is fixed. The lenses are fixed at the two ends of a tube. Then the microscope is focussed by moving it bodily either towards the object or away from the object. Therefore, in the relation for the magnifying power, M ( v D 1 )( 1 ) , it is necessary to find v in terms of fo, fe and the fo fe distance between the objective and the eyepiece. Suppose, the distance between the objective and the eyepiece 102 Chapter 4 : Optical Instruments M A M EL-Morsy = OE = L, OA = v v= OE - A E v = L- A E As A' acts as a point object for the eyepiece whose image is formed at P, 1 1 1 D A E fe (According to the sign convention D and A E are –ve) 1 1 1 D A E fe D fe 1 1 1 A E D fe D. f e or AE = D . fe D fe v ( L Dfe ) D fe Substituting the value of v in the formula for magnifying power, M (1 ( D )( fe ( L D fe )( fe L 103 Dfe ) D fe 1) fo Dfe ) fo D fe ) fo Chapter 4 : Optical Instruments ( D fe ) fe M A M EL-Morsy ( L fo Dfe ) D fe fo DL D f o Lfe f o f e Df e M fe . fo D( L f o f e ) f e ( L f o ) fe . fo From the last equation, knowing fe, fo, D and L, the magnifying power of the microscope can be calculated. Note. Actually the objective is not a single lens but it consists of one or more achromatic lenses and the eyepiece also consists of two lenses which give an optically true image. The above discussion only gives the simplest case where O represents the centre of the lens which in equivalent to the lenses present in the objective while E represents the centre of the lens which is equivalent to the lenses present in the eyepiece. 8. SPECTROMETER A spectrometer consists mainly of three parts: 1. Collimator, 2. Prism table and, 3. Telescope. Collimator It consists of an achromatic lens L1, such that the slit S is at its focus. The slit is placed in front of a source of light and the width of 104 Chapter 4 : Optical Instruments M A M EL-Morsy the slit can be adjusted (Fig. 4.7). The slit acts as a source of light and the rays coming out of the lens L1 are parallel. Fig.(4.7) Table The table can be adjusted and its position can be read with the help of the verniers V1, and V2. The table can be rotated about a vertical axis and its axis coincides with the axis of rotation of the telescope. A prism is placed on the table. A parallel beam of light is incident on the prism and the emergent beam is also parallel. Telescope It is an astronomical telescope fitted with a Ramsden's eyepiece and cross wires. When a parallel beam of light coming out of the prism falls on the objective, the spectrum produced is viewed through the eyepiece. If a photograph is to be taken, a photographic plate replaces the eyepiece. 1. Adjustments 105 Chapter 4 : Optical Instruments M A M EL-Morsy The eye-piece of the telescope is adjusted such that the cross wires are clearly visible. The telescope is focussed on a distant object. The parallax between the image and the cross-wires is removed. Thus, the telescope is set for parallel rays. Then, the spectrometer is placed in front of a monochromatic light source (sodium lamp) and the slit is adjusted. The position of the lens of the collimator is adjusted such that a sharp and well-defined image is seen through the telescope. 2. Setting the table The table can he levelled with the help of a spirit level. For accurate work three levelling screws A, B and C provided with the prism table are adjusted. Parallel lines are marked on the table, which are parallel to the line AB. The prism is placed with its edge ab perpendicular to the line AB (Fig. 4.31). Fig. (4.8) The table is adjusted so that both the faces ab and ac of the prism receive light coming out of the collimator. The telescope is brought into the position to receive light from the face ab. The screws A and B are adjusted till the image of the slit is in the centre of field. Then, the telescope is turned to receive light from the face ac. Again by 106 Chapter 4 : Optical Instruments M A M EL-Morsy adjusting the screw C, the image of the slit is brought to the centre of the field of view. 3. Schuster's method The prism is placed on the table and the approximate position for minimum deviation is observed through the telescope. The telescope is rotated for a position making an angle more than the minimum deviation. In this position of the telescope, there will be two positions of the prism when the image of the slit can be viewed through the telescope. Suppose, in the first case, the prism is in the position A (Fig. 4.9). The incident rays from the collimator are falling more obliquely on the prism. The telescope is focussed so that the image is sharp and there is no parallax between the image and the cross-wires. In this case the rays coming out of the prism become more parallel. Keeping the position of the telescope fixed, the prism table is rotated such that the image of the slit is again viewed through the telescope. Suppose the prism in now in the position B. Here less oblique rays pass through the prism. The image in this case will be blurred. It in focussed by adjusting the distance between the slit and the collimating lens. The telescope in not adjusted in this case. 107 Chapter 4 : Optical Instruments M A M EL-Morsy Fig.(4.10) The prism is again brought back to the position A and the process is repeated. When the image of the slit is sharp and there is no parallax between the image and the cross-wires, the spectrometer is adjusted. The collimator produces parallel rays, which are focussed on the cross-wires of the telescope after passing through the prism. 9. OF THE MATERIAL OF A PRISM Angle of the prism After setting the spectrometer, the prism is placed on the table as shown in Fig. (4.11). The slit is just close to the source of monochromatic light i.e., to light from the sodium lamp. 108 Chapter 4 : Optical Instruments M A M EL-Morsy Fig. (4.11) Both the faces ab and ac receive light from the collimator. The telescope is rotated and the image formed by reflection at the face a b is observed through the telescope in the position P. The readings of the verniers are noted. The telescope is rotated to receive light reflected by the face ac and again the readings are taken. The angle between the positions P and Q is twice the angle of the prism. Fig. (4.12). Use Fig.(4.12) to proof that the angle ( = 1+2) is equal to 2A . Where A is the angle of the prism. Angle of minimum deviation 109 Chapter 4 : Optical Instruments M A M EL-Morsy The prism is placed on the prism table and the image of the slit after refraction through the prism is observed through the telescope. The prism table is rotated so that the angle of deviation decreases. The telescope is also rotated so as to follow the image. Finally, a position is reached when the image is stationary and with the rotation of the prism table in the same direction, the image recedes and the angle of the deviation increases. The cross-wires of the telescope are made to coincide with the image of the slit when it is stationary. This is the position of minimum deviation (Fig. 4.13). The position of the telescope is observed. The telescope is brought to view the image of the slit directly and its position is noted. The angle through which the telescope has been rotated from the position of minimum deviation, gives the angle of minimum deviation. Fig.(4.13) Suppose the angle of the prism = A and the angle of minimum deviation = The refractive index of the material of the prism for the given monochromatic light in given by 110 Chapter 4 : Optical Instruments M A M EL-Morsy A 2 A sin 2 sin In a good spectrometer two lines are observed for sodium light. The two angles of minimum deviation are observed and the refractive indices for the two lines of sodium (D1 and D2) are calculated. The spectrometer is also used to determine: 1. The dispersive power of the material of a given prism. 2. The wavelength of a given source of light by using a diffraction grating. 10. PULFRICH REFRACTOMETER It is used to measure the refractive indices of solids and liquids. It consists of a right-angled prism A having its two faces perfectly plane. One of the faces is horizontal and the other is vertical (Fig. 4.14). 111 Chapter 4 : Optical Instruments M A M EL-Morsy Fig.(4.14) The solid B whose refractive index is to be determined is taken having two faces cut perpendicular to one another. The faces are made perfectly plane. The solid B is placed on the prism A. To bring perfect contact between the horizontal faces of A and B, a few drops of a liquiq whose refractive index is greater than the solid is used. In the case of a liquid, whose refractive index is to be determined, a glass cell ia used. Light is incident in a direction parallel to the horizontal surface so that light entering the prism A is incident at the critical angle c with the normal. Finally it emerges from the prism at an angle i. Let the refractive index of the solid be and that of the material of the prism A be o. Here o > and c is the critical angle. 112 Chapter 4 : Optical Instruments sin c = M A M EL-Morsy o ... (i) sin i sin r Also r + c = /2 , r = /2 -c sin i sin ( 2 c) sin i o cosc … (ii) Squaring and adding equations (i) and (ii) 2 sin 2 i sin c cos c 2 o o2 2 2 o2 sin2 i (iii) Knowing o and i, the value of can be calculated. To measure i, the apparatus has a collimating telescope with a circular scale attached to it. The telescope is adjusted so that the cross-wires lie on the dark edge of the field of view. This gives the position of the minimum angle of emergence i. The material of the prism A has a refractive index of 1.74. In modem instruments, the circular scale is calibrated in terms of the refractive index and readings can be read directly from the scale. In some cases a table is provided with the instruments, which gives the value of corresponding to i. 113 Chapter 4 : Optical Instruments M A M EL-Morsy 11. ABBE REFRACTOMETER Abbe refractometer is used to measure the refractive index of liquids. It consists of two prisms A and B. The prisms have angles 30o , 60o and 90o. The liquid whose refractive index is to be determined is placed between the two prisms (Fig. 4.15). Light is reflected from the glass plate or a ground glass surface P into the prism A. The emergent light is received by the telescope. The rays of light are incident on the hypotenuse face of the prism at various angles of incidence. Fig.(4.15) At a particular angle of incidence, the ray passes along the plane of the liquid and just passes into the second prism. These are the rays, which have an angle of incidence equal to the critical angle. The theory is just similar to Pulfrich refractometer. The telescope is set to a position where the cross-wires lie on the dark edge of the field of 114 Chapter 4 : Optical Instruments M A M EL-Morsy view. This reading is noted. The scale attached to the telescope is calibrated to give the refractive index of the liquid directly. 12. PRISM BINOCULARS Prism binoculars consists of two astronomical telescopes each containing two totally reflecting right angled prisms. In this way the distance between the objectives of the telescope is made Larger than the distance between the two eyes, thus increasing the field of view and the stereoscopic effect pertaining to distance. Moreover, the effective length is made half of the length of the telescope to be used for the same magnification and the final image is also erect. The Prism A is placed with its refracting edge horizontal while the prism B is placed with its refracting edge vertical. In an astronomical telescope the final image formed is inverted. The objective and the eyepiece are convex lenses. The prism A turns the image in the vertical direction upside down ( Fig.4.14). The prism B turns the image in the horizontal direction. The image produced after reflection is erect and magnified. The optical path is about three times the length of the binocular. Therefore, it works as astronomical telescope equal to three times its length. 13. DISPERSION BY A PRISM 115 Chapter 4 : Optical Instruments M A M EL-Morsy A beam of white light, when it passes through a prism is split up into its constituent colours and this is called dispersion of light. The image thus formed on a screen is called a spectrum. Fig. (4.16) The spectrum consists of visible and invisible regions. In the visible region the order of the colours is from violet to red. The principal colours are given by the word VIBGYOR (Violet, Indigo, Blue, Green, Yellow, Orange and Red). The deviation produced for the violet rays of light is maximum and for red rays of light it is minimum. Fig. (4.16) represents the dispersion of a white ray of light by a prism in the visible region. The region of the spectrum, of wavelengths shorter than violet is called ultra-violet and the region of wavelengths longer than red in called infra-red. In the present chapter, the discussion relates only to the visible region of the spectrum. The refractive index for the material of a prism (or a lens) is different for different wavelengths (or colours). The deviation and hence the refractive index is more for blue rays of light than the corresponding values for red rays of light. The deviation and the refractive index of the yellow constituent are taken as the mean 116 Chapter 4 : Optical Instruments M A M EL-Morsy values. If the dispersion through a prism does not follow the order given by VIBGYOR, it is said to be anomalous dispersion. 14. REFRACTION THROUGH A PRISM The refractive index of the material of a prism is given by Where A is the angle of the prism and D is the angle of minimum deviation. For a small angled prism 2 2 where and refer to the angle of the prism and the angle of minimum deviation (for small values of , the angle is also small and the sines of the angles are taken equal to the angles). ( 1 ) Fig.(4.17) Fig. (4.17) represents the angles of deviation b, and r, produced in the blue, mean yellow and red rays of light. The deviations b, and r can be written as : ( 1 ) 117 for mean yellow light ... (i) Chapter 4 : Optical Instruments M A M EL-Morsy b ( b 1 ) for blue light r ( r 1 ) ...(ii) for red light ... (iii) The difference in deviation between any two colours is called angular dispersion. From (ii) and (iii) b r ( b 1 ) ( r 1 ) ( b r ) (iv) b r ( b r ) b r ( 1 ) 1 d 1 ... (v) Dividing (iv) by (i) where b and r are the refractive indices for the blue and red rays of light and is the refractive index for the mean yellow rays of light. The expression b r d ( ) 1 1 is called the dispersive pews; of the material of the prism. It is constant for two colours (or wavelengths) chosen and is represented by . b r 1 The reciprocal of is called the constringence. It is also customary to represent b, and r as F , D and C where F, D and C correspond to the Fraunhoffer lines (dark lines) in the solar spectrum. The F, D and C lines lie in the blue, yellow and red regions of the spectrum and their wavelengths are 4861Å, 5893 Å and 6663 Å, respectively. (1 Å =1 Angstrom unit=10-8 cm). 15. CAUCHY'S DISPERSION FORMULA 118 Chapter 4 : Optical Instruments M A M EL-Morsy When an electromagnetic wave is incident on an atom or a molecule, the periodic electric force of the wave sets the bound charges into vibratory motion. The frequency with which these charges are forced to vibrate is equal to the frequency of the wave. The phase of this motion as compared to the impressed electric force will depend on the impressed frequency. It will vary with the difference between the impressed frequency and the natural frequency of the charges. Dispersion can be explained with the concept of secondary waves that are produced by the induced oscillations of pound charges. When a beam of light propagates through a transparent medium (solid or liquid), the amount of lateral scattering is extremely small. The scattered waves travelling in a lateral direction produce destructive interference. However, the secondary waves travelling in the same direction as the incident beam superimpose on one another. The resultant vibration will depend on the phase difference between the primary and the secondary waves. These superimposition changes the phase of the primary waves and this is equivalent to a change in the wave velocity. Wave velocity is defined as the speed at which a condition of equal phases is propagated. Hence the variation in phase due to interference, changes the velocity of the wave through the medium. The phase of the oscillations and hence that of the secondary waves depends upon the impressed frequency. It is clear, therefore, that the velocity of light in the medium varies with the frequency of light. 119 Chapter 4 : Optical Instruments M A M EL-Morsy Also refractive index depends upon the velocity of light in the medium. Therefore the refractive index of the medium varies with the frequency (wavelength) of light. The relative permittivity of the medium in the case of dynamic polarizability is used to obtain the Cauchy’s dispassion formula which can be written as: A B 2 This equation represents Cauchy's dispersion formula. A and B are called Cauchy's constant. The values of A and B depend on the medium. It is evident that the refractive index of the medium decreases with increase in wavelength of light. Example 4.1. Calculate the values of Cauchy's constants A and B for crown glass. Given c = 1.514, F = 1.524 c = 6563Å F = 4862Å and According to Cauchy's formula A B 2 1.514 A B ( 6563 x 10 8 )2 1.524 A B ( 6862 x 10 8 )2 0.1 B{ 1 1 } 8 2 ( 6862 x 10 ) ( 6563 x 10 8 )2 120 (i) Chapter 4 : Optical Instruments M A M EL-Morsy B= 5.236 X 10-11 cm2 Substituting the value of B in equation (i) and solving A = 1.502 121