Download Product Bulletin

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Wireless power transfer wikipedia , lookup

Power factor wikipedia , lookup

Power over Ethernet wikipedia , lookup

Control theory wikipedia , lookup

Opto-isolator wikipedia , lookup

Power inverter wikipedia , lookup

Electrification wikipedia , lookup

Three-phase electric power wikipedia , lookup

Capacitor wikipedia , lookup

Pulse-width modulation wikipedia , lookup

Variable-frequency drive wikipedia , lookup

Electric power system wikipedia , lookup

Rectifier wikipedia , lookup

Immunity-aware programming wikipedia , lookup

Amtrak's 25 Hz traction power system wikipedia , lookup

Triode wikipedia , lookup

Voltage regulator wikipedia , lookup

Electrical grid wikipedia , lookup

Distributed control system wikipedia , lookup

Surge protector wikipedia , lookup

Automation wikipedia , lookup

Distributed generation wikipedia , lookup

Stray voltage wikipedia , lookup

Electrical substation wikipedia , lookup

Buck converter wikipedia , lookup

Control system wikipedia , lookup

History of electric power transmission wikipedia , lookup

Metadyne wikipedia , lookup

Islanding wikipedia , lookup

Power engineering wikipedia , lookup

Resilient control systems wikipedia , lookup

Voltage optimisation wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Alternating current wikipedia , lookup

Mains electricity wikipedia , lookup

Transcript
CBC-8000
Capacitor Bank Control
Power Quality
Smart grid ready capacitor bank control
delivers automation and efficiency
This state-of-the-art
integrated volt/VAR
intelligent control is built to
easily adapt to emerging
changes you can expect
from the Smarter Grid.
Available as a single,
stand-alone field device
or an entire automation
solution, the CBC-8000
easily integrates with radios
and radio networks, and is
designed with a full suite
of deployment options to
enhance grid efficiency and
power quality.
panel and ProView™ NXG
Maximize distribution system
application software. Each
energy efficiency and power
CBC-8000 control can act as a
quality with the CBC-8000
stand-alone, one-way, or twocapacitor bank control and twoway communicating device
way communications. Eaton’s
with advanced distribution
Cooper Power Systems Smart
automation features and
Grid technology uses Volt/VAR
management products for energy communication loss capability.
efficiency and conservation
This smarter grid control is
voltage reduction (CVR) to reduce
designed for:
generation demand and energy
• Increased efficiency in energy
consumption while maintaining
delivery
customer voltage power quality.
Effective operation of down-line
• Flexible, easy to use
distribution capacitors optimizes
communications
the feeder voltage profile and
• Improved productivity
minimizes VAR flow – a crucial
element to successful energy
• Enhanced power quality
management and greater return
on investment.
The Eaton’s Cooper Power
Systems CBC-8000 capacitor
bank control is a member of a
line of fully integrated controls
which feature a modular,
universal design, capable of
being deployed with various
communications configurations
to meet differing application
needs. The control strategy is
based on field-proven algorithms
and utilizes Eaton’s Cooper
Power Systems standard front
CBC-8000 control — the
smarter choice
Utilities need intelligent
solutions to improve distribution
system voltages and power
factor in order to reduce
generation demand to achieve
significant energy savings.
The CBC-8000, a truly scalable
capacitor bank control, uses
selectable control strategies and
communications to enable users
to control their systems in the
optimum manner. The CBC-8000
control can adapt and grow
as your system does, without
hardware upgrades.
Flexible, easy-to-use
communications
The CBC-8000 control is
specifically designed for
remote operation and retrieval
of field measurement data for
analysis by integrated Volt/VAR
applications. Benefits from this
highly flexible and programmable
control include:
•
Easy integration into a variety
of communication radios,
radio networks, SCADA and
modems
•
Communications data log to
quickly debug communication
problems
•
Communication loss fail-safe
modes for grid stability
•
Unsolicited reporting of
state change, field alarms or
threshold violations for easy
monitoring
•
Available radio-ready or with
utility radio installed at factory
•
Control configurations
upgradable or downloadable
through Eaton’s Cooper Power
Systems ProView NXG
software
•
Meets IEC standards
supporting 120/240 Volt and
50/60 Hz electrical systems
for global applications
CBC-8000 control shown with wireless modem, one of many
communication methods available.
Improved productivity
•
•
Save time and money with remote field configuration and capacitor
bank operation.
The CBC-8000 control can be used with pad-mounted or overhead
capacitor banks.
2
EATON 
CBC-8000 Capacitor Bank Control 
•
Reduce time in the field,
and operating costs with
remote control, scanning,
programming and data log
downloads over the utility’s
secure network
Improve productivity with
remote, over-the-air firmware
and settings updates by
eliminating site visits and
reducing maintenance efforts:
•
Simplified installation
•
Less training needed
•
Highly flexible operational settings
Remote retrieval of over 100
unique analog data points:
•
Engineers can select up to 100
data points
•
Data logged into data log/
sequence of events (SOE)
•
Can be retrieved remotely from
utility’s back office - no need to
visit the control site
Three-phase power quality
measurements
•
Monitors every aspect of
site’s health with full threephase voltage, current, VAR
and harmonic monitoring as
well as capacitor bank neutral
current monitoring via analog
inputs for greater accuracy
•
Offers refined power quality
event monitoring—in the
event of problems or grid
anomalies that may need
detailed analysis
•
Allows utility to monitor and
improve customer’s power
quality
•
ANSI C84.1-2011 phase-to-phase
voltage unbalance monitoring and
reporting
•
Know all three phases of the
capacitor are operational with
Eaton’s three-phase bank operation
confirmation algorithm
Improve productivity with simplified installation.
Voltage Regulators
or Voltage Load Tap
Changer (LTC)
Voltage Regulators
and Controls
Capacitor Banks
and Controls
Overhead
Recloser
Transformers
Yukon IVVC
Software
Distribution automation
solution
Eaton’s Cooper Power Systems
offers the full suite of power
quality software and apparatus
to support your Volt/VAR
management solution. With
unparalleled expertise to make
your automation seamless we
offer:
•
Yukon™ Volt/VAR
management automation
software
•
CBC-8000 capacitor bank
control
•
Pad-mount or rack-mount
capacitor banks
Optimal feeder voltage
Power factor correction
Yukon Volt/VAR Control (IVVC)
software uses capacitors and
regulators to flatten the feeder
voltage profile. The capacitor
acts as both a voltage and power
factor device to deliver the
optimal feeder voltage profile.
The graph below represents the
Yukon IVVC software flattening
the voltage profile – resulting in a
reduction in bus voltage from 122
to 118 volts.
Power factor correction is a
crucial element in improving
energy efficiency and reducing
losses. Capacitors are used to
correct the distribution feeder
VAR flow. The graph below
represents before and after
effective implementation of
Yukon Volt/VAR management
software.
Power Factor
•
CL-7 voltage regulator controls
•
Voltage regulators
•
Recloser controls
2005/2006 Power Factor Comparison for Balch Springs 1905
100.00%
% Power Factor
98.00%
135
96.00%
94.00%
92.00%
90.00%
88.00%
86.00%
84.00%
130
0:
00
:
2: 00
00
:0
4: 0
00
:
6: 00
00
:
8: 00
00
10 :00
:0
0
12 :0 0
:0
0
14 :0 0
:0
0
16 :0 0
:0
0
18 :0 0
:0
0
20 :0 0
:0
0
22 :0 0
:0
0:
0: 0 0
00
:
2: 00
00
:0
4: 0
00
:
6: 00
00
:0
8: 0
00
10 :00
:0
0
12 :0 0
:0
0
14 :0 0
:0
0
16 :0 0
:0
0
18 :0 0
:0
0
20 :0 0
:0
0
22 :0 0
:0
0:
0: 0 0
00
:0
0
82.00%
125
Volts
Maximize the benefits from
implementing a Volt/VAR
management application with
Eaton’s Cooper Power Systems
CYME™ Engineering Services
team. We offer power system
studies to identify the best
combination of regulation
equipment to optimize feeder
voltage profiles and substation
VAR management.
102.00%
Voltage Profile: Local Regulation vs Yukon IVVC
135
Power system studies for
optimized results
Without Volt/VAR Automation
120
Two-Day Profile
Local Regulation
130
With Volt/VAR Automation
Yukon IVVC
115
125
110
120
0
2
4
6
8
Local Regulation
Yukon IVVC
115
10 Regulation
12
Local
14
16
Yukon IVVC
Distance
110
0
6
2
8
4
6
8
10
12
14
10
16
12
14
16
EATON 
CBC-8000 Capacitor Bank Control 
3
The CBC-8000 control is
specifically designed to
operate utility distribution
feeder capacitors. This highly
flexible control can be deployed
in a number of operational
strategies using site metrics,
which include voltage, VARs,
current, temperature and time
control configurations.
Key operating features
2
3
1
•
Trip and close operations
•
Local or remote control of
capacitor banks
•
Voltage threshold monitoring
•
Programmable time delays
for close, trip and re-close
operations
•
Independent control
parameters
Key two-way communication
features
•
Confirmation of trip and close
action
•
Real-time scanning
•
Site alarm notifications
•
Neutral current sensor
(optional)
1.Left-side LEDs to
indicate capacitor
information
2.Ten-key programing
area with LCD display
4
6
3.Right-side LEDs
to indicate control
information
4.Bottom color-coded
area for operating the
control
5.Trip/close push-buttons
with visual indication
5
6.One-touch mode keys
Eaton
1000 Eaton Boulevard
Cleveland, OH 44122
United States
Eaton.com
Eaton’s Cooper Power Systems Business
2300 Badger Drive
Waukesha, WI 53188
Cooperpower.com
© 2013 Eaton
All Rights Reserved
Printed in USA
Publication No. B1160-12066
January 2014
Eaton, Cooper Power Systems, Yukon and
ProView are valuable trademarks of Eaton in
the U.S. and other countries. You are not
permitted to use these trademarks without
the prior written consent of Eaton.
All other trademarks are property
of their respective owners.
For Eaton’s Cooper Power
Systems product information,
call 1-877-277-4636 or visit:
www.CooperPower.com