Download Fluorescence, Quenching, and Applications Thereof
Physical organic chemistry wikipedia , lookup
Stability constants of complexes wikipedia , lookup
Two-dimensional nuclear magnetic resonance spectroscopy wikipedia , lookup
Rotational–vibrational spectroscopy wikipedia , lookup
Astronomical spectroscopy wikipedia , lookup
Chemical imaging wikipedia , lookup
Determination of equilibrium constants wikipedia , lookup
Franck–Condon principle wikipedia , lookup
Fluorescence correlation spectroscopy wikipedia , lookup
X-ray fluorescence wikipedia , lookup
Fluorescence, Quenching, and Applications Thereof Christopher Hampton, Dr. E. F. Healy, Advisor The Nature of Luminescence Production of light is most commonly associated with heat “Cold light” Phenomena (Rendell) Fluorescence Phosphorescence Chemiluminescence Radioluminescence Triboluminescence Fluorescence Dilute atomic vapors Na 3s -> 3p* 589.6nm & 589.0nm resonant fluorescence Stokes Shift Molecular fluorescence Longer wavelengths than the resonance line Jablonski Diagram Absorbance and Emission Absorbance of photon 10^-14 to 10^-15s Deactivation Processes Vibrational Relaxation Internal Conversion External Conversion Intersystem Crossing Radiative Emission Quantum Yield The ratio of the number of molecules that luminesce to the total number of excited molecules Ф = Kf / Kf + Kisc + Kec + Kic + Kpred + Kd More efficient in * -> than * -> n Molar absorptivity 100x more for pp* Lifetime is shorter (10^-7 to 10^9) for pp* Quenching Internal Filtering* or Concentration Quenching Static Quenching (A*+Q -> AQ* ~> AQ) Dynamic Quenching (A*+Q -> A+Q*) Thermal Quenching Oxygen Quenching Photodecomposition or Reaction Fluorescence Work Lucigenin has been known to be quenched by Chloride anions for a long time This phenomenon has not been extensively studied, and no analytical characterization has been done in 40 years. What They Did Lucigenin (dimethylbis(acridinium) nitrate) was obtained and recrystallized twice Absorption spectra were taken with a Cary 14 Fluorescence spectra Xenon ™ Corp 31A nanosecond fluoremetry system. Other organics used as shipped (DMSO, Acetonitrile, and DMF ) Their Results KF (100%) - 17.4 eV NaClO4 (100%) - ?? Na2SO4 (60%) - ?? NaC2H3O2 (31%) - 10.35 NaHSO3 (8.5%) - ?? KCN (5.5%) - 13.7 KCl (5.1%) - 13.0 Ns2SO3 (3.4%) - ?? NaSCN (1.4%) - ?? Na2S (0.3%) - 10.5 Hand-waving Lies and Propaganda Linear dependence of ionization potential works if you leave out 1/2 of their data points. “Heavy atom” effect is ignored for everything but Cl, I, and Br…? No solvent effect on quenching Presence of amines causes photodecomposition so can’t be studied Fluoroscopy Benefits Small samples (3mL) Widely available Limitations Not all materials fluoresce Cost of fluorescent materials Detection limits Fluoroscopy Experimental Method Instrument Used Chemicals Used All of ACS reagent grade Chloride solutions were made from a volumetric NaCl standard solution obtained from Sigma Aldrich (1g Cl- / 100g water) All solutions were made with Millipore water Experimental Method, contd. Standards prepared Lucigenin concentration from an ethanol stock, diluted in water Solutions were combined in a capped cuvette, and vortexed for 30-45 seconds Experimental Method, contd. An excitation spectrum was obtained at 505nm Maximum peak intensity and differentiation was consistently observed at 368 and 432 nm 0.1 µM Lucigenin Quenching 0.1 µM Lucigenin Regression 0.05 µM Lucigenin Quenching 0.05 µM Lucigenin Regression What Does it Mean? 50 nano-molar concentration of Lucigenin, and a 50 micro-molar Clsolutions. 1000:1 ratio of Cl- to Lucigenin. This can be further reduced, but with an introduction of noise to signal ratio loss Ok, but is it real? Still working at concentrations that are showing very distinct patterns We are approaching the limits of detection of our instrument and operator Contamination of our water? Where are we going from here? CE is going to make or break it. Buffer has been problematic Repeat of 25 nm fluorescence data set (clean it up some) Lower the Cl- : Lucigenin ratio to 1:100 (I.e. 10-1µM Cl) Questions?