Survey
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
EBT CLINICAL UPDATE November 2000 EBT Clinical Applications CARDIAC IMAGING Coronary Artery Calcium Scanning Coronary Electron Beam Angiography (EBA) Functional Cardiac Imaging BODY IMAGING Pulmonary Embolism Low-Dose Lung Scanning Abdominal Scanning Colonography Peripheral EBA (Carotid, Aorta, Renal, Femoral) Head Scan EBT Radiation Dose Radiation dose from EBT scans compared to other sources of radiation Radiation Source Millirems Millisieverts EBT Coronary calcium scan 50 to 63 mrem 0.5 to 0.63 mSv EBT Coronary EBA scan 70 to 90 mrem 0.7 to 0.9 mSv EBT Low-dose Lung scan 100 to 150 mrem 1.0 to 1.5 mSv 300 mrem 3.0 mSv 2 mrem 0.02 mSv 8 to 10 mrem 0.08 to 0.1 mSv 48 mrem 4.8 mSv 300 mrem 3.o mSv 500 to 600 mrem 5.0 to 6.0 mSv 600 mrem 6.0 mSv Background radiation in 1year Cross country airplane trip Chest X-ray Abdominal X-ray Lumbar Spine X-ray series Coronary Angiogram Lower G.I. X-ray series The advantage of the EBT over conventional scanners is that, instead of exposing the entire circumference of the body to the X-ray beam, the EBT X-ray beam enters from the back. Thus, anterior structures such as the breast and thyroid are subjected to a lesser dose of radiation (17% of the entrance skin dose). Functional Cardiac Imaging Multi-Slice Mode Cine and Flow Acquisitions Cardiac Imaging Prospective ECG-Triggering Cine Mode – Functional Cardiac Imaging Flow Mode – Perfusion Imaging 80% RR1 40% RR2 Volume Mode – Coronary Imaging (Calcium & EBA) Functional Cardiac Imaging Pre Dobutamine Stress Myocardial Perfusion Scanning Protocol Flow Mode Table is slewed for Long Axis ECG Triggered to 40% of the R to R interval MSM 8 mm 15 to 20 images per level Injection of 35ml IV contrast @ 4ml per second. Repeat scan post stress Post Dobutamine Stress Functional Cardiac Imaging Diastole Systole Pre Dobutamine Stress Pre Dobutamine Stress Ejection Fraction Scanning Protocol Cine Mode Table is slewed for Short Axis ECG Triggered to 0% of the R to R interval MSM CINE mode 8 mm 15 to 20 images per level Injection of 35ml IV contrast @ 4ml per second Repeat scan post stress Post Dobutamine Stress Post Dobutamine Stress Coronary Artery Calcium Scanning Step Volume Mode ECG Triggered Acquisitions Coronary Calcium Scanning Coronary Artery Scanning Protocol Patient Preparation: None ECG Triggered to 60-70% of the R to R interval 3mm contiguous scans From carina to the apex Calcium Report Generation Coronary Artery Calcium Report Agatston Calcium Score Volume Calcium Score Example Images Clinical Findings Clinical Recommendations Further Cardiac testing Coronary Calcium Progression Progression of Right coronary artery calcium score over 5 years 1993 Calcium Score: 56 Volume Score: 45 1995 Calcium Score: 90 Volume Score: 78 1997 Calcium Score: 128 Volume Score: 113 Coronary Calcium Scanning Visualization of Non-obstructive Plaque Formation - EBT LAD LM LAD LCX Soft Plaque G.O. Kerkhoff, Alfried Krupp Hospital Essen (2000) Coronary EBA Step Volume Mode ECG Triggered Acquisition Coronary EBA CLINICAL INDICATIONS Follow-up PTCA and Stents Follow-up Bypass grafts Equivocal results following stress testing (or stress imaging) Congenital anomalies Symptomatic patients with Coronary Calcium score Asymptomatic patients with Coronary Calcium score greater than 400 or in the 75 percentile Pre and post operative Heart transplant patients People who are not willing to have an elective conventional angiogram Coronary EBA Coronary EBA Scanning Protocol Patient Preparation: Start IV ECG Triggered to 40% of the R to R interval 3mm x 2mm scans Injection of 150ml IV contrast @ 4ml per second Normal algorithm, 18 cm FOV Coronary EBA Report Generation Coronary Artery EBA Report Clinical Indication Procedure Example Images Clinical Findings Clinical Recommendations Further Cardiac testing Coronary EBA Posterior Descending Coronary artery This 3 Dimensional Volume Rendered image demonstrates normal coronary arterial flow in the Posterior Descending Coronary artery to the apex of the heart as well as the coronary sinus and cardiac vein. This ECG triggered acquisition consisted of sixty, 3 mm images, each taken at 100 milliseconds. The total acquisition time was 45 seconds with an intravenous injection of 150 ml of contrast media. Coronary EBA G.O. Kerkhoff, Alfried Krupp Hospital Essen (2000) Follow Up PTCA This 3 Dimensional Volume Rendered image demonstrates a re-stenosis in the mid LAD coronary artery in a patient post PTCA This ECG triggered acquisition consisted of sixty, 3 mm images, each taken at 100 milliseconds. The total acquisition time was 45 seconds with an intravenous injection of 150 ml of contrast media. Coronary EBA Coronary Artery Stent Scanning Protocol This 3 Dimensional Volume Rendered image demonstrates a 50% stenosis just proximal to the stent in the left anterior descending coronary artery . This ECG triggered acquisition consisted of sixty, 1.5 mm images, each taken at 100 milliseconds. The total acquisition time was 45 seconds with an intravenous injection of 150 ml of contrast media. Coronary EBA Coronary Stent Courtesy of Milwaukee Heart Scan, Milwaukee, WI Volume rendering technique VRT Virtual Angioscopy FLY THROUGH Maximum intensity projection MIP Coronary EBA Right Coronary Artery Stent G.O. Kerkhoff, Alfried Krupp Hospital Essen (2000) Stent - Ave gfxTM 3,0/30mm Coronary EBA Right Coronary Artery Bypass Graft – Distal anastomoisis G.O. Kerkhoff, Alfried Krupp Hospital Essen (2000) Coronary EBA Right Coronary Artery Bypass Graft G.O. Kerkhoff, Alfried Krupp Hospital Essen (2000) Coronary EBA Central occluded Right Coronary Artery Graft G.O. Kerkhoff, Alfried Krupp Hospital Essen (2000) Coronary EBA Congenital Anomalies This 3 Dimensional Volume Rendered image demonstrates an aberrant circumflex coronary artery that arises from the Right coronary artery. This ECG triggered acquisition consisted of fifty, 3 mm images, each taken at 100 milliseconds. The total acquisition time was 35 seconds with an intravenous injection of 120 ml of contrast media. Coronary EBA Sensitivity & Specificity Number of Patients Non-Evaluated Segments Sensitivity Specifity Moshage et al, Radiology 1995 20 ? 74% 100% Schmermund et al, JACC 1998* 28 12% 83% 91% Reddy et al, Radiology 1998 23 10% 88% 79% Rensing et al, Circulation 1998** 37 18% 77% 94% 125 25% 92% 94% Budoff et al, Am J Cardiol 1999 52 11% 78% 91% Achenbach et al, Heart 2000 36 20% 92% 91% 118 24% 90% 82% Achenbach et al, NEJM 1998 Ropers et al, Z Kardiol 2000 Coronary and Thoracic EBA 76.94mm 77.99mm Large Thoracic Aneurysm G.O. Kerkhoff, Alfried Krupp Hospital Essen (2000) Coronary and Thoracic EBA Thoracic aortic stent (Talent MedtronicTM) in dissection of the aorta True Lumen False Lumen G.O. Kerkhoff, Alfried Krupp Hospital Essen (2000) Lung Scanning Continuous Volume Scan Lung Scanning Lung Scan Protocol Patient Preparation: None This Continuous Volume acquisition consisted of forty seven, 6 mm images, each taken at 300 milliseconds. The total acquisition time was 18 seconds. Findings: Asbestosis Lung Scanning Lung Scan Protocol Patient Preparation: None This Continuous Volume acquisition consisted of forty seven, 6 mm images, each taken at 300 milliseconds. The total acquisition time was 18 seconds. Findings: Lung Nodule Right Upper Lobe Pulmonary Embolism Pulmonary Embolism Acute Scan Protocol Patient Preparation: None This Continuous Volume acquisition consisted of 42, 6 mm images, each taken at 100 milliseconds. The total acquisition time was 5 seconds with an intravenous injection of 50 ml of contrast media @ 3 ml per second. Findings: Large embolism in right and left main pulmonary arteries. Pulmonary Embolism Pulmonary Embolism Chronic Scan Protocol Patient Preparation: NPO 4 hour prior to scanning. This Continuous Volume acquisition consisted of 120, 3 mm images, each taken at 100 milliseconds. The total acquisition time was 5 seconds with an intravenous injection of 50 ml of contrast media @ 3 ml per second. Maximum Intensity Projections Abdominal Scanning Continuous Volume Scan Abdominal Scan Abdomen screen Protocol Patient Preparation: Optional NPO after midnight the night prior to the exam. Drink 24 oz of gastrographin and H2o mix 2 hour prior and 12 oz before scanning. This Continuous Volume acquisition consisted of, 6mm images, each taken at 400 milliseconds. The total acquisition time was 24 seconds. Abdominal Scan Abdomen Diagnostic Protocol Patient Preparation: NPO after Midnight the night prior to the exam. Drink 24 oz of gastrographin and H2o mix 2 hour prior and 12 oz before scanning. This Continuous Volume acquisition consisted of sixty one, 10 mm images, each taken at 600 milliseconds. The total acquisition time was 22 seconds with an intravenous injection of 90 ml of contrast media @ 2.0 ml per second. EBT Colonography EBT Colonography Patient Preparation: 24 to 48 hour colon preparation. NPO after midnight the night prior to the exam. This Continuous Volume acquisition consisted of 140, 3mm images, each taken at 200 milliseconds. The total acquisition time was 28 seconds with and air contrast enema. Peripheral EBA Continuous Volume Scan Renal EBA Renal Arteries This coronal Maximum Intensity Projection image demonstrates normal renal arterial flow. This Continuous Volume acquisition consisted of seventy, 3 mm images, each taken at 400 milliseconds. The total acquisition time was 28 seconds with an intravenous injection of 100 ml of contrast media. Abdominal Aortic EBA Abdominal Aortic EBA Scan Protocol This 3D Volume Rendered image loop demonstrates arterial flow through a post operative abdominal aortic graft. This Continuous Volume acquisition consisted of one hundred and forty, 3 mm images, each taken at 200 milliseconds. The total acquisition time was 28 seconds with an intravenous injection of 120 ml of contrast media. Abdominal Aortic EBA Post operative Abdominal Aortic Graft G.O. Kerkhoff, Alfried Krupp Hospital Essen (2000) Maximum intensity projection MIP Shaded surface display SSD Volume rendering technique VRT Femoral and Iliac EBA Femoral and iliac EBA Scanning Protocol This coronal Maximum Intensity Projection image demonstrates arterial flow through a post operative abdomenoiliac graft. G.O. Kerkhoff, Alfried Krupp Hospital Essen (2000) This Continuous Volume acquisition consisted of one hundred and forty, 3 mm images, each taken at 200 milliseconds. The total acquisition time was 28 seconds with an intravenous injection of 120 ml of contrast media. Carotid EBA Carotid Arteries This 3 Dimensional Volume Rendered image demonstrate the the carotid arteries (RED) and venous circulation (BLUE). This Continuous Volume acquisition consisted of forty, 3 mm images, each taken at 300 milliseconds. The total acquisition time was 12 seconds with an intravenous injection of 60 ml of contrast media. Head Scanning Continuous Volume Scan Cerebral EBA Internal Carotid This axial Maximum Intensity Projection image demonstrates the Left internal carotid artery with limited flow to the Right. G.O. Kerkhoff, Alfried Krupp Hospital Essen (2000) This Continuous Volume acquisition consisted of forty, 3 mm images, each taken at 600 milliseconds. The total acquisition time was 24 seconds with an intravenous injection of 80 ml of contrast media. Cerebral EBA Cerebral AVM This 3 Dimensional Volume Rendered image demonstrate the Circle of Willis with an Arterial Vascular Malformation (AVM). This Continuous Volume acquisition consisted of forty, 3 mm images, each taken at 600 milliseconds. The total acquisition time was 24 seconds with an intravenous injection of 100 ml of contrast media. Cerebral EBA Cerebral EBA This axial Maximum Intensity Projection image demonstrates cerebral arterial flow. This Continuous Volume acquisition consisted of forty-five, 6 mm images, each taken at 600 milliseconds. The total acquisition time was 27 seconds with an intravenous injection of 100 ml of contrast media. Head Scan Head Scanning Protocol Patient Preparation: NPO 4 hours before the scan. This Continuous Volume acquisition consisted of forty one, 6 mm images, each taken at 600 milliseconds. The total acquisition time was 25 seconds with an intravenous injection of 90 ml of contrast media @ 2.0 ml per second.