* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download Chapter 6: Single Phase Transformer
Power factor wikipedia , lookup
Ground loop (electricity) wikipedia , lookup
Induction motor wikipedia , lookup
Spark-gap transmitter wikipedia , lookup
Electric machine wikipedia , lookup
War of the currents wikipedia , lookup
Pulse-width modulation wikipedia , lookup
Electric power system wikipedia , lookup
Ground (electricity) wikipedia , lookup
Mercury-arc valve wikipedia , lookup
Electrification wikipedia , lookup
Power inverter wikipedia , lookup
Stepper motor wikipedia , lookup
Electrical ballast wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Amtrak's 25 Hz traction power system wikipedia , lookup
Power electronics wikipedia , lookup
Power MOSFET wikipedia , lookup
Earthing system wikipedia , lookup
Opto-isolator wikipedia , lookup
Current source wikipedia , lookup
Single-wire earth return wikipedia , lookup
Power engineering wikipedia , lookup
Surge protector wikipedia , lookup
Voltage regulator wikipedia , lookup
Stray voltage wikipedia , lookup
Electrical substation wikipedia , lookup
Buck converter wikipedia , lookup
Resonant inductive coupling wikipedia , lookup
Voltage optimisation wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Three-phase electric power wikipedia , lookup
Mains electricity wikipedia , lookup
History of electric power transmission wikipedia , lookup
BASIC ELECTRICAL TECHNOLOGY DET 211/3 Chapter 6: Single Phase Transformer Introduction to Transformer A transformer is a device that changes ac electric energy at one voltage level to ac electric energy at another voltage level through the action of a magnetic field. The most important tasks performed by transformers are: • • • changing voltage and current levels in electric power systems. matching source and load impedances for maximum power transfer in electronic and control circuitry. electrical isolation (isolating one circuit from another or isolating dc while maintaining ac continuity between two circuits). It consists of two or more coils of wire wrapped around a common ferromagnetic core. One of the transformer windings is connected to a source of ac electric power – is called primary winding and the second transformer winding supplies electric power to loads – is called secondary winding. Ideal Transformer An ideal transformer is a lossless device with an input winding and output winding. v p (t ) v s (t ) i p (t ) Np Ns 1 i s (t ) a Sp SS 1 lossless a N p i p ( t ) N s is ( t ) a = turns ratio of the transformer Power in ideal transformer Pout Pin V p I p cos Qout Qin V p I p sin S out S in V p I p sin Where is the angle between voltage and current Impedance transformation through the transformer The impedance of a device – the ratio of the phasor voltage across it in the phasor current flowing through it: ZL VL IL ZL' a2ZL The equivalent circuit of a transformer The major items to be considered in the construction of such a model are: • Copper (I2R) losses: Copper losses are the resistive heating in the primary and secondary windings of the transformer. They are proportional to the square of the current in the windings. • Eddy current losses: Eddy current losses are resistive heating losses in the core of the transformer. They are proportional to the square of the voltage applied to the transformer. • Hysteresis losses: Hysteresis losses are associated with the arrangement of the magnetic domain in the core during each half cycle. They are complex, nonlinear function of the voltage applied to the transformer. • Leakage flux: The fluxes ΦLP and ΦLS which escape the core and pass through only one of the transformer windings are leakage fluxes. These escaped fluxes produce a self inductance in the primary and secondary coils, and the effects of this inductance must be accounted for. Nonideal or actual transformer Mutual flux Nonideal or actual transformer Nonideal or actual transformer Transformer equivalent circuit, with secondary impedances referred to the primary side Ep = primary induced voltage Vp = primary terminal voltage Ip = primary current Ie = excitation current XM = magnetizing reactance RC = core resistance Rs = resistance of the secondary winding Xs = secondary leakage reactance Es = secondary induced voltage Vs = secondary terminal voltage Is = secondary current IM = magnetizing current IC = core current Rp = resistance of primary winding Xp = primary leakage reactance Nonideal or actual transformer Transformer equivalent circuit Dot convention 1. If the primary voltage is positive at the dotted end of the winding with respect to the undotted end, then the secondary voltage will be positive at the dotted end also. Voltage polarities are the same with respect to the dots on each side of the core. 2. If the primary current of the transformer flows into the dotted end of the primary winding, the secondary current will flow out of the dotted end of the secondary winding. Exact equivalent circuit the actual transformer a) The transformer model referred to primary side b) The transformer model referred to secondary side Approximate equivalent circuit the actual transformer a) The transformer model referred to primary side b) The transformer model referred to secondary side Exact equivalent circuit of a transformer Ep = primary induced voltage Vp = primary terminal voltage Ip = primary current Ie = excitation current XM = magnetizing reactance RC = core resistance Rs = resistance of the secondary winding Xs = secondary leakage reactance Es = secondary induced voltage Vs = secondary terminal voltage Is = secondary current IM = magnetizing current IC = core current Rp = resistance of primary winding Xp = primary leakage reactance Primary side Secondary side I p Ie I s / a ES I s ( Rs jX s ) Vs Ie IC I M Vs I s Z L V p I p ( R p jX p ) E p E p I C RC E p I M ( jX M ) E p I e ( RC // jX M ) Vp Ep Is N p a Vs Es I p N s Exact equivalent circuit of a transformer referred to primary side Rp Ip a2Xs Xp Is/a a2Rs Ie Vp Ep aVs Exact equivalent circuit of a transformer referred to secondary side Rp/a2 aIp Xp/a2 Rs Is Xs aIe Vp/a aIc Rc/a2 aIm Ep/a = Es XM/a2 Vs Approximate equivalent circuit of a transformer referred to primary side Ip Reqp jXeqp Is/a + Reqp=Rp+a2Rs + Xeqp=Xp+a2Xs Vp Rc aVs jXM - - Approximate equivalent circuit of a transformer referred to secondary side aIp Reqs + jXeqs Is + Reqs=Rp/a2+Rs Xeqs=Xp/a2+Xs Vp/a Rc/a2 - jXM/a2 Vs - Example A single phase power system consists of a 480V 60Hz generator supplying a load Zload=4+j3W through a transmission line ZLine=0.18+j0.24W. Answer the following question about the system. a) If the power system is exactly as described below (figure 1(a)), what will be the voltage at the load be? What will the transmission line losses be? b) Suppose a 1:10 step-up transformer is placed at the generator end of the transmission line and a 10:1 step down transformer is placed at the load end of the line (figure 1(b)). What will the load voltage be now? What will the transmission line losses be now? Example ILine IG ZLoad=0.18+j0.24W + ILoad VLoad V=48000V ZLoad=4+j3W - Figure 1 (a) T1 IG 1:10 ILine T2 ILoad ZLine=0.18+j0.24W + 10:1 V=48000V VLoad Figure 1 (b) - Solution Example (a) From figure 1 (a) shows the power system without transformers. Hence IG = ILINE = ILoad. The line current in this system is given by: I line V Z line Z load 4800V (0.18W j 0.24W) (4W j 3W) 4800 4800 4.18 j 3.24W 5.2937.8 90.8 37.8 Solution Example Therefore the load voltage is: Vload I lineZ load (90.8 37.8 A)( 4W j 3W) (90.8 37.8 A)(536.9W) 454 0.9 and the line losses are Ploss ( I line ) 2 Rline (90.8 A) 2 (0.18W) 1484W Solution Example (b) From figure 1 (b) shows the power system with the transformers. To analyze the system, it is necessary to convert it to a common voltage level. This is done in two steps: i) Eliminate transformer T2 by referring the load over to the transmission’s line voltage level. ii) Eliminate transformer T1 by referring the transmission line’s elements and the equivalent load at the transmission line’s voltage over to the source side. The value of the load’s impedance when reflected to the transmission system’s voltage is Z 'load a 2 Z load 10 2 ( ) ( 4W j 3W) 1 400W j 300W Solution Example The total impedance at the transmission line level is now: Z eq Z line Z 'load 400.18W j 300.24W 500.336.88W The total impedance at the transmission line level (Zline+Z’load) is now reflected across T1 to the source’s voltage level: Z 'eq a 2 Z eq a 2 ( Z line Z 'load ) 1 2 ( ) (0.18W j 0.24W 400W j 300W) 10 (0.0018W j 0.0024W 4W j 3W) 5.00336.88W Solution Example Notice that Z’’load = 4+j3 W and Z’line =0.0018+j0.0024 W. The resulting equivalent circuit is shown below. The generator’s current is: IG 4800V 95.94 36.88 A 5.00336.88W a) System with the load referred to the transmission system voltage level b) System with the load and transmission line referred to the generator’s voltage level Solution Example Knowing the current IG, we can now work back and find Iline and ILoad. Working back through T1, we get: N p1 I G N s1 I line I line N p1 N S1 IG 1 (95.94 36.88 A) 10 9.594 36.88 A Solution Example Working back through T2 gives: N p 2 I line N s 2 I load I load N p2 Ns2 I line 10 ( )(9.594 36.88 A) 1 95.94 36.88 A It is now possible to answer the questions. The load voltage is given by Vload I load Z load (9.594 36.88 A)(536.87W) 479.7 0.01V Solution Example and the line losses are given by: Ploss ( I line ) 2 Rline (9.594 A) 2 (0.18W) 16.7W Notice that raising the transmission voltage of the power system reduced transmission losses by a factor of nearly 90. Also, the voltage at the load dropped much less in the system with transformers compared to the system without transformers.