* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download EEE307 Electromechanical Energy Conversion Homework I (Due
Current source wikipedia , lookup
Electrical ballast wikipedia , lookup
Mercury-arc valve wikipedia , lookup
Ground (electricity) wikipedia , lookup
Power inverter wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Stray voltage wikipedia , lookup
Power electronics wikipedia , lookup
Opto-isolator wikipedia , lookup
Voltage regulator wikipedia , lookup
Surge protector wikipedia , lookup
Distribution management system wikipedia , lookup
Magnetic core wikipedia , lookup
Earthing system wikipedia , lookup
Buck converter wikipedia , lookup
Power engineering wikipedia , lookup
Electrical substation wikipedia , lookup
Single-wire earth return wikipedia , lookup
Voltage optimisation wikipedia , lookup
Rectiverter wikipedia , lookup
Switched-mode power supply wikipedia , lookup
History of electric power transmission wikipedia , lookup
Mains electricity wikipedia , lookup
Resonant inductive coupling wikipedia , lookup
Alternating current wikipedia , lookup
EEE307 Electromechanical Energy Conversion Homework I (Due on March 24th 2015) 1. An inductor of the form given below has dimensions: Cross-sectional area Ac = 3.6 cm2 ; Mean core length lc = 15 cm ; N = 75 turns. Assuming a core permeability µ= 2100µ0 and neglecting the effects of leakage flux and fringing fields, calculate the air-gap length required to achieve an inductance of 6.0 mH. 2. Draw the magnetic circuit for the system given below: 3) The nameplate on a 9.2-kV:460-V, 46-kVA, single-phase transformer indicates that it has a series reactance of 10 percent (0.10 per unit). a) Calculate the series reactance in ohms as referred to (i) the low-voltage terminal and (ii) the high-voltage terminal. b) If three of these transformers are connected in a three-phase Y-Y connection, calculate (i) the three-phase voltage and power rating, (ii) per unit impedance of the transformer bank, (iii) the series reactance in ohms referred to the high-voltage terminal, and (iv) the series reactance in ohms as referred to the low-voltage terminal. EEE307 Electromechanical Energy Conversion Homework I (Due on March 24th 2015) c) Repeat part (b) if the three transformers are connected in ∆ on the high-voltage side and Y on their low-voltage terminal. 4) A 15-kV: 150-kV, 150-MVA, 60-Hz single-phase transformer has primary and secondary impedances of 0.0095 + j0.063 per unit each. The magnetizing impedance is j148 per unit. All quantities are in per unit on the transformer base. Calculate the primary and secondary resistances and reactances and the magnetizing inductance (referred to the low-voltage side) in ohms and henrys. 5) A 50-kVA, 2400/240-V, 60-Hz single phase transformer has a short-circuit test performed on its high-voltage side. The following test results are obtained: Voltage (V) Current (A) Power(W) Short-Circuit (LV shorted) 48 20.8 500 Open-Circuit (HV open) 240 5.4 150 a) Draw the transformers equivalent circuit. b) Determine its voltage regulation, and efficiency at rated load, 0.8 power factor lagging, and rated voltage at the secondary terminals.