* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download SmartStart:Solid State Starter
Electrical ballast wikipedia , lookup
Commutator (electric) wikipedia , lookup
Electric power system wikipedia , lookup
Power inverter wikipedia , lookup
Current source wikipedia , lookup
Electric machine wikipedia , lookup
Mercury-arc valve wikipedia , lookup
Electrical substation wikipedia , lookup
Pulse-width modulation wikipedia , lookup
History of electric power transmission wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Stray voltage wikipedia , lookup
Electrification wikipedia , lookup
Power engineering wikipedia , lookup
Brushless DC electric motor wikipedia , lookup
Opto-isolator wikipedia , lookup
Buck converter wikipedia , lookup
Distribution management system wikipedia , lookup
Electric motor wikipedia , lookup
Mains electricity wikipedia , lookup
Power electronics wikipedia , lookup
Voltage optimisation wikipedia , lookup
Alternating current wikipedia , lookup
Three-phase electric power wikipedia , lookup
Induction motor wikipedia , lookup
Brushed DC electric motor wikipedia , lookup
Motion Control Engineering REPAIR SOLUTIONS SmartStart: Solid State Starter Better hydraulic motor control performance demanding less power, maintenance and space SmartStart is a fully integrated starter that reliably controls voltage and current for hydraulic elevator pump motor applications. Standard features include a reverse phase sensor, adjustable trip class electronic overload protection, fault contactor, configurable auxiliary contacts, multiple start/stop modes, and increased motor/system diagnostics. Applications • Large horsepower motors • High elevator usage (high number of starts per hour) • Retrofit on existing installations with motor/contactor failure history • Power company line-current restrictions From any angle, SmartStart delivers value: • Controller space is at a premium Reliability — no contacts to replace saves material, labor and downtime costs; overcurrent protection extends motor life while maximizing maintenance intervals. Benefits Efficiency — low starting current with adjustable acceleration ramp eliminates high in-rush current. • Increased system performance • Maintenance not required • Compact, space-saving footprint Versatility — replaces across-the-line, resistance start, wye-delta and increment/part winding starting schemes with no additional space requirement. • Increased system flexibility • Decreased downtime Precision — up-to-speed contact feature determines exactly when to connect load to motor for smooth, trouble-free ride. • Easy to purchase, install and set up Features The streamlined SmartStart footprint is almost 70% smaller than leading competitive starters. www.mceinc.com 800.444.7442 916.463.9200 The leader in non-proprietary controllers, technical services and repair solutions for elevator modernization. • Eliminates motor damage resulting from contactor welding • Limits line disturbances from in-rush currents • Eliminates inspection and replacement of contacts • Offers advanced diagnostic monitoring • ABC\CBA rotation switch SmartStart: Solid State Starter SmartStart specifications Solid State Starter Current range 6.3–85A (3-Lead Motor), 10.9–147A (6-Lead Motor) Voltage range 200–600 VAC 50/60Hz Control voltage 120 VAC Starting modes Soft start Reduced space, high functionality SmartStart is a simple replacement for existing mechanical starter applications. SmartStart provides for 3, 6, 9 or 12 lead motor winding terminations with no major wiring change necessary. Current limit start High current rating in compact design Kick start Features Overload protection Fault diagnostics Flexibility in trip class (10, 15, 20 or OFF) Overtemperature in power section Connects to the motor using the inside-the-delta (√3 factor) wiring configuration, allowing the compact design of SmartStart to accommodate a higher motor amp rating. Phase reversal Selectable overload reset (Manual or Automatic) Transitionless motor starting Phase loss/Open load SmartStart uses a current limit starting method to eliminate the transition current spike found in StarDelta applications. This greatly reduces mechanical and electrical shock to the motor and is especially important when power supplies are limited. Shorted SCRs Phase imbalance (enable/disable switch) Compact size with true 3-phase control Integrated bypass contacts minimize heat generation during run-time. The bypass automatically closes when the motor reaches its nominal speed, resulting in a cooler-running component and reduction in starter size. Starter selection table 6 LEAD DELTA AC MCE PART Voltage No. FLA 50-07-0001 32 50-07-0002 51 200-600 50-07-0003 64 VAC 50-07-0004 74 50-07-0005 104 50-07-0006 147 3 LEAD WYE HP for Voltages @ 50/60 HZ 3 Phase 208 10 15 20 20 30 40 240 10 15 20 25 40 50 380/415 20 25 40 40 60 100 460 20 30 40 50 75 100 Easy and secure setup HP for Voltages @ 50/60 HZ 3 Phase 575 30 40 60 60 100 150 FLA 19 30 37 43 60 85 208 5 7.5 10 10 15 25 240 5 10 10 15 20 30 380/415 460 10 10 20 20 20 25 25 30 40 40 60 60 575 15 25 30 40 50 75 DIP switches allow for easy, precise and secure setting of the start/stop profile, overload trip class and auxiliary contact characteristics. Setting the overload FLA is easily accomplished using the rotary pot located on the front of the device. www.mceinc.com 800.444.7442 916.463.9200 The leader in non-proprietary controllers, technical services and repair solutions for elevator modernization. SS-DS-03-0505