* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download INSTALLATION INSTRUCTIONS - Power
Ground loop (electricity) wikipedia , lookup
Spark-gap transmitter wikipedia , lookup
Power engineering wikipedia , lookup
Immunity-aware programming wikipedia , lookup
Stepper motor wikipedia , lookup
Pulse-width modulation wikipedia , lookup
Power inverter wikipedia , lookup
Electrical ballast wikipedia , lookup
Electrical substation wikipedia , lookup
History of electric power transmission wikipedia , lookup
Three-phase electric power wikipedia , lookup
Integrating ADC wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Current source wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Power electronics wikipedia , lookup
Power MOSFET wikipedia , lookup
Distribution management system wikipedia , lookup
Schmitt trigger wikipedia , lookup
Buck converter wikipedia , lookup
Opto-isolator wikipedia , lookup
Surge protector wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Alternating current wikipedia , lookup
Stray voltage wikipedia , lookup
Voltage regulator wikipedia , lookup
INSTALLATION INSTRUCTIONS VR504A-21ODC Voltage Regulator Serial #O4O1OO92 and up lnput from generator, RUN/IDLE SW 5Arc 277 vac. F+ - rl tt \--1 vv /Exc \ DO NOT CONNECT WIRINGTO THIS TOP TERMINAL BOARD. Externalvoltage adjustment,1 to 5k, 1/5w pot. Installa jumperbetween5 and 6 if not used. 1 Flicker / indicator light 1 UNITED STATES PATENT NUMBER 51.38205 Voftageinput required: Operationaloutputvoltage ranger Maximumoperationalamperage: Minimumfield resistance: Operationalfrequerrcyrange: Regulationacqrracy: Physical size: Totalweighr Intemalfusing: Maximum/ minimumKW: MinimumresidualBUV: 5OTA 277 VAC .75 TO 240 VDC 5 ADC* 20 OHMS** 40 TO 80 HZ +/- .596 1.25 in.X 6 in. X 4.75 in. 7 q.JNcEs 5 AAC Unlimited 3 VAC @ 50 HZ * Higheramperages with optionalSE35O-2OO adaptors. ** @120vac input,40 ohms@24OvacinBut. Makesurethat exciterfield resistance is 20 ohmsor more. Makesurethat exciter 1. grounded is lessthan fieldsarenot or connectedto anyothercircuitry.lf the field resistance 20 ohms,a SE350-200excitermoduleshouldbe usedwith this regulator. \* regulator.To limitthe output ?.. Input50 to 277 vacto the inputof the VR504A-21ODC potential voltage of this regulatorfor lowerexcitervoltagessuchas 32 vdc or less,60 to 120 208 to 24Avacis recommended. vacis suggested.Formostapplications, Mfg bla Power-Tronics,Inc. CorpusChristi, Texas \_, lnstalla runlidleswitchin the inputvoltagecircuitif the generatoris goingto operate 3. belowratedgeneratorrpmsuchaswarmup or cooldownidle. of lessthan 5 adc,installa fuseratedto Forextraprotectionon fieldrequirements 4. regulator. into the inputof the VR504A-21ODC desiredamperage DO NOT: Supplypoweranddc outputthru a commoncableunlesseachpairis shieldedand to ground. oneendconnected if a to volt metersor otherinstrumentation Connectinputto the VR504A-21ODC phaseselectorswitchis used. Openthe dc outputwhilethe generatoris operating. SET UP AND \_- OPERATION UP NEVERUSEA DIGITALMETERFORSETTING A GENERATOR.USE ONLY A VANE TYPE METER. MECHANICAL This regulatoruses SCRphasecontrol which resultsin incorrectreadings in digitalmeters becauseof averagingtime samplingof the digital meter. 1. Turnall controlpots fully ccw. 2. for properhookup. Checkall connections 3. Startprimemoverandbringup to ratedspeed. 4. Turnon powerswitchif used. 5. ( When first installed, the build up voltage at the requlator will be approximately35 vac and erratic) Slowlyadjust P1 cw until the line voltage is reading807oof desiredsetting. lf at this time the voltageis erraticor pulsing,slowly turn P3 untilthe voltagestabilizes.Thiscanbe observedwith the stability/ indicator of P3 aremade,the voltagewill rise. lightlocatedjust aboveP3. As the adjustments Keepvoltageat 80% by alsoadjustingPl lowerto compensate.Makeall adjustmentsvery slowly! The indicatorlight will not glow until the voltageat the regulatoris at or above50 vac. 6. Installgeneratoron line. Observevoltageandadjustif needed. Mfgby Power-Tronics, Inc. Corpus Christi, Texas TROUBLE SI{OOTING No build up of voltage: With generator running at operating speed, check the residualvoltage at 1 and 2 on the VR504A-21ODCterminalstrip. The voltage shouldbe more than 3 volts ac. lf the volta_oe is belowthis value,removethe exciter fields from the regulatorand momentarilyapply 1Z vdc to them while the generatoris runningat speed. The voltage at i and 2 at the voltage regulatorshould increaseto a much highervalue duringthis test. lf the voltage does not increaseto a rnuchhigher value,checkall wiringand fusingthat leadto th€ regulatorfor open circuits. lf the voltage at 1 and 2 on the voltage regulatorincreasesduringthe test, this could indicatethat the regulatoris darnagedor defective or the internal fuses have blown. lf the line voltage did not increaseon the generatorwhen the exciter fields were connectedto the 12 vcic,there is an internaiproblemin the generatorsuch as an open exciterfield, shortedor open diodes in the rectifier bank, open i'oior or biowrrstaior'. After this test, disconnectthe 12 vdc from the exciterfields and re- connectthe field leadsio the regulator. Makesure that the lead that was connectedto the positiveof the I2 volts is connectedto 3 and the leadthat was connectedto negativeis connectedto 4 on the voltage regulator. Runthe generatorup to speed. Go aheadand set up the regulatoras previouslydescribed. lf there is no buildup and the residualvoltage at 1 and 2 is still too low, changethe input voltage to 24O or ?77 vac which shoulddoublethe residualvoltage at 1 and 2. lf when hookedup with a ?4O vac input, if the residualis still too low for build up, then an external flashing circuit will have to be installed. Minor flickering of voltage: P3 is not set far enough cw. With generator disconnected from load, slowlyturn P3 cw until flickeringstops. " \-, Voltage is high and uncontrollable: Low input voltage to 1 and 2, voltage regulator is defective or the exciterfield is grounded. Anotherreasonfor this is that the exciteramperageexceedsthe rating of the voltage regulator. Intermittent flashes or glitches in voltage: Loose connection to regulator ac input or a defective exciter field with a carbon track or interrnittent open in field coil or loose componentsin the voltage regulator due to excessivevibration. Voltage rises with load: Unbalancedloading of generator leads or P3 needs to be adjusted more cw. Voltage falls off with load: P3 is adjusted too far cw, adjust ccw until voltage droop is satisfactory.Another reasoncould be that the input voltage to 1 and 2 is too low for full load exciter voltage. Voltage will not adjust to lower values: lnput wiring to voltage regulator is supplied thru a cord or cable that is unshielded. Use loose wirinq or shieldedcables. Voltage is affected when SCR heating or motor speed controls are used on generator: This is due to line notchingcausedby the SCR. Installa 2.5 uf 250 v capacitoracrossthe 1 and 2 input of the requlator. If you need advice or technical assistance please call: POWER-TRONICS, INC. (s1.2)881-e382 Mfg b;c Power-Tronics, Inc. Corpus Christi, Texas