* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download Timer and switching relay
Nanogenerator wikipedia , lookup
Index of electronics articles wikipedia , lookup
Transistor–transistor logic wikipedia , lookup
Analog-to-digital converter wikipedia , lookup
Integrating ADC wikipedia , lookup
Josephson voltage standard wikipedia , lookup
Current source wikipedia , lookup
Valve RF amplifier wikipedia , lookup
Operational amplifier wikipedia , lookup
Power MOSFET wikipedia , lookup
Power electronics wikipedia , lookup
Current mirror wikipedia , lookup
Surge protector wikipedia , lookup
Schmitt trigger wikipedia , lookup
Immunity-aware programming wikipedia , lookup
Voltage regulator wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Network analysis (electrical circuits) wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Timer and switching relay Timer and switching relays Timers ¾ ¾ ¾ ¾ Power-on delayed Power-off delayed Power-on and power-off delayed Switch-on and/or switch-off wiping (pulse shaper) Function timer relay ¾ ¾ ¾ ¾ ¾ ¾ Clock generator Flasher relay Relay for star-delta changeover Pulse counter Coupling relay Tilting relay Additional function relay ¾ is available in the product overview and on our home page www.schleicher-electronic.com 45 x 75 mm Page 25 2 Equipment sizes 2 72 x 72 mm 48 x 48 mm 2 22.5 x 90 mm 2 Subject to change without further notice FUNCTIONAL RELAYS CLOCK GENERATOR TIMERS VERSION DZ 12-SL DZN 12-SL DZ 52-SL DZA 52-SL DZD 92 L KPT 11 KD KSP 12 KMZ 71 KMZ 72 KMZ 91 KMZ 92 KZTH 11 NGB 12 NGD 31 NGM 1004 NGM 1600 NGS 12 NGZ 11 NGZ 12 NGZ 12-S NGZ 71 NGZ 110 NGZ 310 NGZ 710 NGZ 720 NGZP 32 SSP 56 SSY 12 UZD 51 Product overview timer and switching relays Multi-function Single function Multi-range Single range • Fixed time Response delay • Power-on delay (pulse excitation) Power-off delay Power-off delay without auxiliary voltage Power-on and power-off delay, symmetrical Switch-on wiper Switch-off wiper Switch-on wiper and switch-off wiper Start of pause, symmetrical and adjustable Start of pause, pause and pulse can be adjusted separately Start of impulse, symmetrical and adjustable Start of pulse, symmetrical and fixed setting Start of pulse, pause and pulse can be adjusted separately Start of pause and pulse, sym. & fixed clock time setting range Pulse generator, power-on delay, pulse output Pulse generator, start of pause, pause duration adjustable, fixed pulse time Pulse generator, alternating, pause or pulse time adjustable Pulse generator (switch-on wiper) Continuation relay, function: On-off Flasher relay, start of pause, symmetrical and fixed setting Coupling relay with immediate changer Tilt relay, zero-voltage safe Star-delta relay: Changeover, switch-on wiper CONTACT S Time changer 8 4 4 8 8 • • 5/6 6 7 10 • • • 10 16 • • • 7 7 7 7 3 8 • • • • • • • 13 • • • • • 16 16 • • • • • • • 16 16 • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • 2 1 1 2 2 2 1 2 1 3 2 • 1 2 1 1 2 1 1 1 1 1 2 2 1 1 1 1 1 2 1 Immediate NO 1 2 1 1 2 1 1 2 1 1 3 Multi-voltage AC/DC 24 - 230V Separated voltage ranges CHARACTERISTIC 1 1 2 Closing / opening contact each HOUSING • • • 1 1 1 1 2 Immediate changer • • • • • • • • • • • • • • • • • • • • • • + • • + + + + + Immediate signal via B1 (B) or reset (R) Setting digital (D) or analogue (A) ± B A A A A A/D A A A A A A R A A A A A A A A A A A A D 48 x 48 mm 72 x 72 mm 22.5 mm • • Zero-voltage safe Adding (+) or adding or subtracting (±) • • Remote potentiometer connection Body housing • • • • Time NO Built-in housing 8 • • • • • • • 45 mm • • • • • • • • • • • • • • • • • • • • • • 1 = 1 timer and 1 immediate changer or 2 timers, depending on the function = 1 timer and immediate changer or 2 time changers, adjustable 3 = semi-conductor 2 Page 26 Subject to change without further notice DZ 12 - SL DZ 12-SL DZN 12-SL Response-delayed single-domain time relay • • • • Devices for Mono voltage Function: response delay (AV), zero voltage-proof at DZN 12-S L 1 time domain Contact assembly: 1 timed and 1 immediate contact 72 mm x 72 mm Wiring diagram Time domains available setting ranges: 0.05 … 1 s 0.1 … 3 s 0.2 … 6 s 0.4 … 12 s 1 … 30 s 2 … 60 s 3.3 … 100 s 0.1 … 3 min 0.2 … 6 min 0.4 … 12 min General information • The electromechanical timed relays are equipped with a synchronous motor and a magnet coupling. • The infinitely adjustable time setting within a domain is performed with the aid of the transparent knob. The time elapse indicator runs during operation from the set time to 0. Notes: • By a frequency inversion on the bottom of the casing, the relay can be adjusted to the respective frequency (50 or 60 Hz). The factory setting is 50 Hz. • The relays have separate motor and magnet connectors. This results in various operation modes: 1. Time addition: Saving already elapsed times and/or adding various time sections by separate actuation of the magnet coupling and the motor. 2. Quick start: Reduction of time Scatter to a minimum by constantly maintaining the motor's voltage and only exciting as well as deexciting the magnet coupling after the time elapse. This avoids the motor fault. At elapsed times over 60 s, the quick start no longer affects the time Scatter. 3. Normal operation: Simultaneous excitation and de-excitation of the magnet coupling and the motor. Recommended for elapsed times over 60 s. • The greatest recurrence precision can be attained by selecting the smallest possible time domain for the multi-domain version. • The time domain toggle on the devices should only occur in the default position - since otherwise, time errors and faulty contact toggles may occur. 1 2 4 0.1 0.2 0.4 1 2 4 … … … … … … … … … 30 60 120 3 6 12 30 60 120 min min min h h h h h h Function Upon excitation of the motor and the magnet, the immediate contact is moved to the operating position, and the time elapse begins. If the preselected time is attained, the time contact is activated and the motor is powered off. After the de-excitation, the magnet, the timing element and all contacts move to the default position. If a voltage interruption occurs during the time elapse, then the magnet, immediate contact and timing element fall into the default position. For the zero voltage-proof timed relay DZN 12-S L, the function is as described above; however, in the course of the excitation, the magnetic valve is latched by a latch pin, so that even in the deenergized state, the already elapsed time is maintained. The time elapse can be interrupted any number of times. Even during the voltage interruption, the immediate contact remains in the operating position. If the preselected time is attained. The latch pin is released and the timed contact is activated. Impulse triggering: To activate the zero voltage-proof timed relay, an impulse to the coupling suffices, since immediate latching occurs by way of the latch pin (Motor and inductor connectors separate). The time elapse begins upon motor excitation. The immediate contact moves to its operating position after the impulse triggering until the end of the time elapse. After the time elapses, it moves back to the default position. The time contact only opens for approx. 10 ms. A toggle of the time contact to the "a" contact side does not transpire. Reset: A mechanical Reset to 0 is possible for these devices. Reset DZN 12-S L: An electrical and mechanical reset to 0 is only possible with this device when the mechanical latch is canceled. If a reset must occur after an interruption of the time elapse, the knob is to be turned to 0. DZ 12 SL Page 27 DZ 12 SL Function diagrams Dimensional drawing Accessories Bushing plate Plug-in socket Adapter B5 B7 BT 421 Cover Recloseable cap Seal DA 1 V4 Z1 for installation and setup for installation for track assembly of the bushing plate B 5 for switchboard cut-out for switchboard installation Device overview / Order numbers Type DZ 12-S L Setting range 0.05 … 1 s 0.1 … 3 s 0.2 … 6 s 0.4 … 12 s 1 … 30 s 2 … 60 s 3.3 … 100 s 0.1 … 3 min 0.2 … 6 min 0.4 … 12 min 1 … 30 min 2 … 60 min 4 … 120 min 0.1 … 3 h 0.2 … 6 h 0.4 … 12 h 1 … 30 h 2 … 60 h 4 … 120 h 0.4 … 12 min DZN 12-S L Page 28 DZ 12 SL Rated voltage AC 230 V 50/60 Hz AC 110-115 V 50/60 Hz AC 230 V 50/60 Hz AC 110-115 V 50/60 Hz AC 230 V 50/60 Hz AC 110-115 V 50/60 Hz AC 230 V 50/60 Hz AC 24 V 50/60 Hz AC 110-115 V 50/60 Hz AC 230 V 50/60 Hz AC 110-115 V 50/60 Hz AC 230 V 50/60 Hz AC 230 V 50/60 Hz AC 110-115 V 50/60 Hz AC 230 V 50/60 Hz AC 110-115 V 50/60 Hz AC 230 V 50/60 Hz AC 24 V 50/60 Hz AC 48 V 50/60 Hz AC 110-115 V 50/60 Hz AC 230 V 50/60 Hz AC 110-115 V 50/60 Hz AC 230 V 50/60 Hz AC 110-115 V 50/60 Hz AC 230 V 50/60 Hz AC 110-115 V 50/60 Hz AC 230 V 50/60 Hz AC 110-115 V 50/60 Hz AC 230 V 50/60 Hz AC 110-115 V 50/60 Hz AC 230 V 50/60 Hz AC 110-115 V 50/60 Hz AC 230 V 50/60 Hz AC 110-115 V 50/60 Hz AC 230 V 50/60 Hz AC 110-115 V 50/60 Hz AC 230 V 50/60 Hz AC 230 V 50/60 Hz AC 24 V 50/60 Hz AC 230 V 50/60 Hz Order number R2.024.1029.0 R2.024.0109.0 R2.024.1769.0 R2.024.0629.0 R2.024.0839.0 R2.024.1959.0 R2.024.1009.0 R2.024.0819.0 R2.024.0099.0 R2.024.1019.0 R2.024.0789.0 R2.024.1229.0 R2.024.0449.0 R2.024.0539.0 R2.024.0129.0 R2.024.0799.0 R2.024.0909.0 R2.024.0849.0 R2.024.1529.0 R2.024.0549.0 R2.024.0859.0 R2.024.0529.0 R2.024.1169.0 R2.024.0559.0 R2.024.0399.0 R2.024.0349.0 R2.024.1129.0 R2.024.1079.0 R2.024.1899.0 R2.024.1069.0 R2.024.0729.0 R2.024.1519.0 R2.024.1089.0 R2.024.1639.0 R2.024.0709.0 R2.024.0379.0 R2.024.0809.0 R2.024.1139.0 R2.024.1499.0 R2.024.0979.0 DZ 12 - SL Technical Data Function type according to DIN VDE 0435 Section 110:04.89 Function indicator Supply circuit Nominal voltage UN Rated output Motor at 50 Hz and UN (AC) Rated output inductor at 50 Hz and UN (AC) Nominal frequency Operating voltage range Timing circuit Time setting / Quantity of time domains Available time domains Standby reactivation interval Minimum power-on time Fallback value Parallel consumer loads permissible Internal one-way rectification direction Error (mean value of the scale end value) Scatter Setting range 0.03 to 1 s Setting range 0.3 to 10 s Setting range 3.3 to 100 s End time ≥ 3 min Output circuit Contact allocation Contact material Switching nominal voltage Un Max. steady current In Usage category according to EN 60947-5-1:1991 Permissible frequency of operation Mechanical service life Response time Fallback time General Data Air and creep sections between the power circuits Rated surge voltage Over-voltage category Degree of contamination Rated voltage Testing voltage Ueff 50 Hz according to DIN VDE 0110-1, Table A.1 Safety class for casing/terminals according to DIN VDE 0470 Section 1:11.92 Interference emission Interference resistance Ambient temperature, work area Dimensional drawing Wiring diagram Weight Accessories DZ 12-S L Electro-mechanical time relay for Mono voltage Item 3.13: Response-delayed time relay Indicator for elapsed time FD 0008 DZN 12-S L Electro-mechanical time relay for Mono voltage Item 3.14: Response-delayed, zero voltage-proof timed relay Indicator for elapsed time FD 0033 see Device overview approx. 1.3 VA / approx. 1.1 W approx. 4.5 VA / approx. 3.8 W 50 and 60 Hz, can be toggled on the device 0.8 to 1.1 x UN Analog / 1 s. Table "Time domains" ≤ 250 ms – ≥ 15 % UN yes yes In normal operation: Setting range > 6 s; ± 1.5 % Setting range 6 s; ± 2 % Setting range 3 s; ± 3 % Setting range 1 s; ± 8 % Normal operation Quick start ± 0.045 s ± 0.015 s ± 0.09 s ± 0.06 s ± 0.54 s ± 0.51 s ± 0.5 % based on scale end value 30 ms 1 timed and 1 immediate contact Ag Cu AC/DC 230 V 5A AC-15: Ue 230 V AC, Ie 2 A DC-13: Ue 24 V DC, Ie 2 A ≤ 3600 switching cycles/h 6 30 x 10 switching cycles or 4 3 x 10 motor operation hours ≤ 30 ms ≤ 60 ms according to DIN VDE 0110-1:04.97 4 kV III 3 exterior, 2 interior AC 250 V 2.21 kV IP 30/IP 20 EN 50081-1:03.93. -2:03.94 EN 50082-2:1995 –10 to +55 °C D 1-18 KS 5102/3 0.6 kg B 5, B 7, BT 421, DA 1, V 4, Z 1 DZ 12 SL Page 29 DZ DZA / DZAN 52 / 53 L / SL DZA 52-SL DZA 53-SL Response-delayed multi-domain time relay • • • • • • • 72 mm x 72 mm DZAN 52-SL DZA 52 L Devices for Mono voltage Function: response delay (AV), zero voltage-proof at DZAN 52-S L 1 Setting range subdivided into 6 time domains contact assembly: DZA 52-S L = 1 timed and 1 immediate contact DZAN 52-S L = 1 timed and 1 immediate contact DZA 53-S L = 2 timed contacts and 1 immediate "a" contact DZA 52 L = 2 timed contacts Wiring diagram Time domains Available setting ranges: 0.1 s to 1000 s subdivided into 6 time domains 0.1 … 3 s 0.3 … 10 1 … 30 s 3.3 … 100 s 10 … 300 s 33 … 1000 s 0.2 s to 60 h subdivided into 6 time domains 0.2 … 6 s 2 … 60 s 0.2 … 6 min 2 … 60 min 0.2 … 6 h 2 … 60 h 0.1 s to 30 h subdivided into 6 time domains 0.1 … 3 s 1 … 30 s 0.1 … 3 min 1 … 30 min 0.1 … 3 h 1 … 30 h General information Function (continued) Impulse triggering: To trigger the zero voltage-proof timed relay, an impulse to the coupling suffices - since immediate latching occurs by way of the latch pin (motor and inductor connectors separate). The time elapse begins upon the motor excitation. After triggering the impulse, the immediate contact moves to its working position, at which time elapse has ended. After this time has elapsed, it falls back to the default position. The timed contact opens only for approx. 10 ms. A toggle of the time contacts to the "a" contact side does not transpire. Reset: A mechanical Reset to 0 is possible for these devices. Reset DZAN 52-S L: An electrical and mechanical Reset to 0 is only possible on this device when the mechanical latch is deactivated. If a Reset must take place following an interruption of the time elapse, then the extinguisher lever on the front plate (top right on the front plate) in the direction of the arrow. Accessories Bushing plate Plug-in socket Adapter B 5 or B 9 B 7 or B 8 BT 421 Cover Recloseable cap Seal DA 1 V4 Z1 Page 30 for installation and setup for installation for track assembly of the bushing plate B 5 for switchboard cut-out for switchboard installation A / DZAN 52 / 53 L / SL • The electromechanical timed relays are equipped with a synchronous motor and magnetic coupling. • The setting of the time domains occurs at the front, via a selector switch,. The infinitely adjustable time setting within a domain is performed with the aid of the transparent knob. • The time elapse indicator runs during operation from the set time value to 0. Function Upon the excitation of the motor and the magnet, the immediate contact is set to the operating positions, and the time elapse begins. If the preselected time is attained, the time contact is activated and the motor powered off. After the de-excitation, the magnet, the timing element and all contacts move to the default position. If a voltage interruption occurs during the time elapse, then the magnet, the immediate contact and the timing element fall into the default position. For the zero voltage-proof timed relay DZAN 52-S L, the function is as described above; however, during excitation, the magnetic flap is latched shut by a latch pin, so that even in the deenergized state, the alreadyelapsed time is maintained. The time elapse can be interrupted any number of times. The immediate contact also remains in the operating position during the voltage interruption. If the preselected time has been attained, the latch pin is released, the time contacts are activated and the motor powered off. DZA / DZAN 52 / 53 L / SL Function diagrams Notes • By way of a frequency toggle on the bottom of the casing, the relay can be adjusted to the respective frequency (50 or 60 Hz). The plant's default setting is 50 Hz. • The relays have separate motor and magnet connectors. This results in various operation modes: 1. Time addition: Saving already-elapsed times and/or adding different time sections by separate actuation of the magnet coupling and the motor. 2. Quick start: Reduction of time scatter to a minimum, by always keeping the motor live (and only the magnet coupling is excited and de-excited after the time elapses). This avoids the motor fault. For elapsed times over 60 s, the quick start no longer affects time scatter. 3. Normal operation: Simultaneous excitation and de-excitation of the magnetic coupling and the motor. Recommended for elapsed times over 60 s. • The largest return precision is attainable by selecting the smallest possible time domain in the multi-domain version. • The time domain toggle on the devices should only occur in the default position - since otherwise, time errors and faulty toggle of the contacts may occur. Dimensional drawing Device overview / Order numbers Type DZA 52-S L Setting range 0.1 s … 1000 s 0.1 s … 30 h 0.2 s … 60 h DZAN 52-S L 0.1 s … 1000 s 0.1 s … 30 h 0.2 s … 60 h DZA 53-S L DZA 52 L 0.2 s … 60 h 0.2 s … 60 h Rated voltage AC 24 V 50/60 Hz AC 110-115 V 50/60 Hz AC 125-127 V 50/60 Hz AC 230 V 50/60 Hz AC 24 V 50/60 Hz AC 110-115 V 50/60 Hz AC 125-127 V 50/60 Hz AC 230 V 50/60 Hz AC 24 V 50/60 Hz AC 42 V 50/60 Hz AC 48 V 50/60 Hz AC 110-115 V 50/60 Hz AC 125-127 V 50/60 Hz AC 230 V 50/60 Hz AC 24 V 50/60 Hz AC 110-115 V 50/60 Hz AC 230 V 50/60 Hz AC 24 V 50/60 Hz AC 110-115 V 50/60 Hz AC 230 V 50/60 Hz AC 24 V 50/60 Hz AC 110-115 V 50/60 Hz AC 230 V 50/60 Hz AC 230 V 50/60 Hz AC 24 V 50/60 Hz AC 110-115 V 50/60 Hz AC 230 V 50/60 Hz Order number R2.027.0219.0 R2.027.0039.0 R2.027.0049.0 R2.027.0099.0 R2.027.0329.0 R2.027.0279.0 R2.027.0309.0 R2.027.0079.0 R2.027.0339.0 R2.027.0179.0 R2.027.0229.0 R2.027.0259.0 R2.027.0279.0 R2.027.0059.0 R2.027.0289.0 R2.027.0239.0 R2.027.0199.0 R2.027.0119.0 R2.027.0129.0 R2.027.0089.0 R2.027.0149.0 R2.027.0189.0 R2.027.0029.0 R2.027.0269.0 R2.027.0209.0 R2.027.0139.0 R2.027.0069.0 DZA / DZAN 52 / 53 L / SL Page 31 DZ DZA / DZAN 52 / 53 L / SL Technical Data Function type according to DIN VDE 0435 Section 110:04.89 DZA 52-S L DZAN 52-S L DZA 53-S L DZA 52 L Electro-mechanical time relay for Mono voltage Responsedelayed time relay Responsedelayed time relay FD 0040 FD 0011 Function indicator Function diagram Responsedelayed, zero voltage proof time relay Indicator for elapsed time FD 0008 FD 0033 Supply circuit Nominal voltage UN Rated output (motor) at 50 Hz and UN (AC) Rated output (inductor) at 50 Hz and UN (AC) Nominal frequency Operating voltage range see Device overview approx. 1.3 VA / approx. 1.1 W approx. 1.0 VA / approx. 0.9 W 50 and 60 Hz, can be toggled on the device 0.8 to 1.1 x UN Responsedelayed time relay Timing circuit Time setting / Number of time domains Available time domains Standby reactivation interval Minimum power-on time Fallback value Parallel consumer loads permissible Internal one-way rectification direction Fault (mean value of the scale end value) Scatter Setting range 0.3 to +6 s Setting range 3 to +60 s End time ≥ 60 s Output circuit Contact allocation Contact material Switching nominal voltage Un max. steady current In Usage category according to EN 60947-5-1:1991 Permissible frequency of operation Mechanical service life Response time Fallback time General Data Air and creep sections between the electric circuits Rated voltage impulse Excess voltage category Degree of contamination Rated voltage Testing voltage Ueff 50 Hz according to DIN VDE 0110-1, Table A.1 Safety class for casing on the front side/casing on the rear side/flat plug Interference emission Interference resistance Ambient temperature, work area Dimensional drawing Wiring diagram Weight Accessories Page 32 A / DZAN 52 / 53 L / SL analog / 6 s. Table "Time domains" ≤ 250 ms – 30 ms ≥ 15 % UN yes yes at normal operation: Setting range > 6 s; ± 1.5 % Setting range 6 s; ± 2 % Normal operation Quick start ± 0.06 s ± 0.03 s ± 0.22 s ± 0.19 s ± 0.3 % based on scale end value 1 timed and 1 timed and 1 immediate 1 immediate contact contact Ag Cd O AC/DC 230 V 5A AC-15: Ue 230 V AC, Ie 2 A DC-13: Ue 24 V DC, Ie 2 A ≤ 3600 switching cycles/h 6 30 x 10 switching cycles or 4 3 x 10 Motor operation hours ≤ 25 ms ≤ 80 ms – – 2 time contact 2 time contact and 1 immediate "a" contact according to DIN VDE 0110-1:04.97 4 kV III 3 exterior, 2 interior AC 250 V 2.21 kV IP 54/IP 20/IP 00 EN 50081-1:03.93. -2:03.94 EN 50082-2:1995 –10 to +55 °C D 1-25 KS 5102/3 KS 5102/3 KS 5151/2 0.4 kg B 5, B 7, B 8, B 9, BT 421, DA 1, V 2, Z 2 KS 5153/2 DZD 92 L DZD 92 L Multi-Function - Multi-domain time relay • • • • Mono voltage 8 Functions Setting range 0.05 s to 100 h subdivided into 7 time domains 1 immediate-action and 1 time contact or 2 time contacts (adjustable) 72 mm x 72 mm Wiring diagram Time domains Setting range 0.05 s to 100 h subdivided in: 0.05 s … 1 s 3 min … 1 0.5 s … 10 s 30 min … 10 3s … 1 min 5 h … 100 30 s … 10 min h h h Function Dimensional drawing The setting of the functions and the time domains as well as the fitting with contacts occurs via a dual in-line switch on the rear of the device (see Settings). The infinitely adjustable time setting within a domain is made with the aid of the transparent knob. The set target value is indicated digitally, with a three-digit (7-Segment) LED indicator. The respective actual value is indicated during the time elapse in analog mode (with 11 LEDs above the scale numbers) and also digitally (with the LED indicator). Functions: • Response delay (AV) • Power-off delay (RV) • Switch-on wiper (EW) • Switch-off wiper (AW) • Response and fallback delay (ARV) • Impulse former (IF) • Pulse relay beginning with pause(TP) • Pulse relay beginning with impulse(TI) Indicators B1 red LED, lit in presence of the excitation B2 red LED, lit in presence of the excitation for additive operation K Accessories Bushing plate Plug-in socket Cover Recloseable cap Seal B5 B7 DA 1 V4 Z1 for installation and setup for installation for switchboard cut-out for switchboard installation red LED, lit upon the toggling of the time contact s; m; h red LEDs for the domain indicator; the lit section indicates the set time domain and flashes when the time elapses 3-digit LED indicator for the set target value (and or during the countdown - indication of the actual value DZD 92 L Page 33 DZD 92 L Function diagrams Page 34 DZD 92 L Function diagrams DZD 92 L Function diagrams Function diagrams Settings The setting of the functions, the time domains and the contact assembly occurs via a dual-in-line switch (equipped with 10 On/Off switches) on the rear of the device. Switch position Time domain 0.05 s to 1 s 0.5 s to10 s 3 s to 1 min 30 s to 10 min 3 min to 1 h 30 min to 10 h 5 h to 100 h Function response delay Power-off delay Switch-on wiper Switch-off wiper Response and fallback delay Impulse former Pulse relay beginning with pause Pulse relay beginning with impulse Contacts 1 timed and 1 immediate changer 2 time changer Resolution 0.01 s 0.05 s 0.5 s 5 s 0.5 min 5 min 0.5 h 1 2 3 4 5 6 7 8 9 o o o •o •o oo •o •o •o •o •o •• o o o •o •o oo ••o o o • •o• o • • ••• • = ON (cam at top) Switch position: Switch, 8 to +0 available DZD 92 L o • Page 35 0 DZD 92 L Technical Data DZD 92 L Function type according to IEC 60050 (445) Function check Analog-adjustable MultiFunction relay for Mono voltage - Response-delayed time relay - Fallback-delayed time relay with supply voltage - Power- on interval time relay - Power-off interval time relay - Response and fallback delayed time relay - Impulse former - Pulse relay 6 LED red, 3-digit LED indicator, red, digit height: 7.6 mm Supply circuit Nominal voltage UN Rated output at 50 Hz and UN (AC) Rated output DC Nominal frequency Operating voltage range Nominal current of the energizing quantity (B1) see Device overview 4.7 VA / 4.6 W 2.6 W 50 to 60 Hz 0.8 to 1.1 x UN 8 mA Timing circuit Time setting/Number of time domains Available setting range Operate time of the energizing quantity (B1) Fallback interval of the energizing quantity (B1) Standby reactivation interval Minimum power-on time Fallback value Parallel consumer loads permissible Internal one-way rectification direction Mean value of the fault Scatter Influence of energizing, supply voltage Influence of the ambient temperature analog/7 s. Table "Time domains" ≤ 20 ms; ≤ 2 ms at 24 V DC ≤ 20 ms; ≤ 3 ms at 24 V DC ≤ 40 / ≤ 60 ms; ≤ 40 / ≤ 10 ms at 24 V DC ≤ 40 ms; ≤ 5 ms at 24 V DC ≥ 15 % UN yes no ≤ 1 % ± 10 ms ≤ ± 0.5 % + ± 10 ms ≤ 0.005 % / % ∆ UN ≤ 0.005 % / K Output circuit Contact allocation Contact material Switching nominal voltage Un max. steady current In Usage category according to EN 60947-5-1:1991 Permissible frequency of operation Mechanical service life Operate time Fallback time General Data Air and creep sections between the electric circuits Rated surge voltage Over-voltage category Degree of contamination Rated voltage Testing voltage Ueff 50 Hz according to DIN VDE 0110-1, Table A.1 Safety class for casing / terminals according to DIN VDE 0470 Section 1:11.92 Interference resistance according to IEC 61000-4 Ambient temperature, work area Weight Accessories Approvals 1 immediate-action and 1 time changer or 2 time changers Ag alloy; gold-plated 250/300 V AC/DC 5A AC-15: Ue 230 V AC, Ie 2 A DC-13: Ue 24 V DC, Ie 2 A ≤ 6000 switching cycles/h 6 30 x 10 switching cycles approx. 10 ms approx. 10 ms according to DIN VDE 0110-1:04.97 4 kV III 3 exterior, 2 interior 250 V AC 2.21 kV IP 30 / IP 20 Test acuity 3 –20 to +60 °C 0.4 kg B 5, B 7, DA 1, V 4, Z 1 – Device overview / Order numbers Type DZD 92 L Page 36 Time delay s. Table "Time domains" DZD 92 L Rated voltage DC 24 V AC 24 V 50-60 Hz AC 42 V 50-60 Hz AC 115 V 50-60 Hz AC 230 V 50-60 Hz Order number R2.054.0349.1 R2.054.0329.1 R2.054.0339.1 R2.054.0309.1 R2.054.0319.1 KPT 11 / 31 KD KPT 11 KD KPT 31 KD Multi range repeat cycle timer • • • • • • Dual voltage 1 function: KPT 11 KD: repeat cycle starting with OFF (TP) KPT 31 KD: repeat cycle starting with ON (TI) Setting range from 0.05 s to 10 h divided into 10 time ranges 1 change-over contact 2 LEDs for function display Circuit diagram Time ranges Setting range from 0.05 s to 10 h divided into: 0.05 s … 1 s 15 s 0.15 s … 3 s 50 s 0.5 s … 10 s 0.05 h 1.5 s … 30 s 0.15 h 5s … 100 s 0.5 h … … … … … 300 1000 1 3 10 s s h h h Function Function diagrams Different OFF and ON times can be selected in decimal increments on the relay front by means of selector switches. The OFF and ON time within a range is set using the selector wheel. The different supply voltages have to be connected to their respective assigned terminal. Dimension diagram KPT 11 / 31 KD Page 37 DZ KPT 11 / 31 KD Technical data Function type according to EN 60050 Function display Function diagrams Power supply circuit Rated voltage UN AC/DC AC Rated consumption at 50 Hz and UN (AC) Rated consumption at 50 Hz and UN (AC) Rated consumption DC Starting current inrush stroke Rated frequency Operating voltage range A / ms Time circuit Time setting / number of time ranges Available setting range Recovery time 1/2 Minimum on time Release value Repeat cycle starting with Parallel loads permissible Internal half-wave rectification Mean value of the error Dispersion Influence of the energizing quantity, supply voltage Influence of the ambient temperature Output circuit Contact assignment Contact material Rated operating voltage Un Max. continuous current In Application category according to EN 60947-5-1:1991 Permissible switching frequency Mechanical life Response time Release time General information Creepage distances and clearances between the circuits Rated impulse voltage Overvoltage category Degree of pollution Rated voltage Test voltage Ueff 50 Hz according to DIN VDE 0110-1. table A.1 Protection degree housing/terminal according to DIN VDE 0470 sec. 1:11.92 Noise immunity according to IEC 61000-4 Ambient temperature, operating range Dimension diagram Circuit diagram Weight Accessories KPT 11 KD KPT 31 KD Electronic multi-range repeat cycle timer starting with OFF. For dual voltage. Repeat cycle relay with two different supply voltage terminals 1 green LED, 1 red LED FD 0069 Electronic multi-range repeat cycle timer starting with ON. For dual voltage. Repeat cycle relay with two different supply voltage terminals 24 V 115 V 5.5 VA 1.2 W 1.2 VA 1.0 W 0.7 W 1.5 / 2 0.5 / 2 50 – 60 Hz 0.8 – 1.1 x UN 24 V 1.2 VA 1.0 W 0.7 W 1.5 / 2 analogous/ 10 See table "Time ranges" approx. 40 / approx. 80 ms – ≥ 15 % UN OFF Yes No ≤ ± 10 % ≤ ± 0.5 % + ± 10 ms ≤ 0.005 % / % ∆ UN ≤ 0.005 % / K 230 V 7.5 VA 1.5W 0.5 / 3 42 V 60 V 1.2 VA 1.0 W 0.8 W 0.1 / 6 1.5 VA 1.3 W 1.2 W 0.05 / 10 ON 1 change-over contacts Ag alloy, gold-plated 230/230 V AC/DC 5A AC-15: Ue 230 V AC, Ie 2 A DC-13: Ue 24 V DC, Ie 2 A ≤ 6000 switching cycles/h 6 30 x 10 switching cycles – approx. 40 ms according to DIN VDE 0110-1:04.97 4 kV III 3 outside, 2 inside 250 V AC 2.21 kV IP 30 / IP 20 Test severity 3 –20 to +60 °C K1-8 W3 KS 0342/2 0.12 kg – Overview of devices / Part numbers Type KPT 11 KD KPT 31 KD Page 38 Rated voltage AC/DC 24 V and AC 115 V 50-60 Hz AC/DC 24 V and AC 230 V 50-60 Hz AC/DC 42 V and AC 60 V 50-60 Hz AC/DC 24 V and AC 115 V 50-60 Hz AC/DC 24 V and AC 230 V 50-60 Hz AC/DC 42 V and AC 60 V 50-60 Hz DZD 92 L ON-delay time See table "Time ranges" See table "Time ranges" Part No. R2.111.0019.3 R2.111.0029.3 R2.111.0039.3 R2.111.0049.1 R2.111.0059.1 R2.111.0069.1 KSP 12 KSP 12 Electronic flip-flop relay • Mono voltage • 1 Function: flip-flop relay • 1 changer, 1 NO contact Wiring diagram Function With the application of the supply voltage to the terminals A2/A3, the contacts 11/14, 23/24 are closed. After the supply voltage is powered off, the contact position is maintained. With the application of the supply voltage to the terminals A1/A3 the contacts toggle, 11/12 are closed and 23/24 open. After the supply voltage is powered off, the contact position is maintained. The relay can also be activated manually (at the front), by a lever. The simultaneous excitation of both circuits is not permissible. Function diagram Dimensional drawing KSP 12 Page 39 KSP 12 Technical Data KSP 12 Function type according to IEC 60050 Electronic flip-flop relay for Mono voltage - flip-flop relay Switch position indicator FD 0128 Function check Function diagram Supply circuit Nominal voltage UN Rated output at 50 Hz and UN (AC) (50 ms after activation)) Rated output DC (50 ms after activation)) Power-on current pulse Peak current at 50 Hz and UN (AC) (activation)) Peak current at DC (activation)) Nominal frequency Operating voltage range AC/DC Timing circuit Time setting / Quantity of time domains Available setting range Standby reactivation interval Minimum power-on time fallback value Parallel consumer loads permissible Internal one-way rectification direction Median value of the fault Scatter Influence of the energizing quantity, supply voltage Influence of the ambient temperature Output circuit Contact assembly Contact material Switching nominal voltage Un Max. steady current In Usage category according to EN 60947-5-1:1991 Permissible frequency of operation Mechanical useful life Operate time fallback time General Data Distances (sparking and "crawl") between the electric circuits Rated voltage impulse Excess voltage category Degree of contamination Rated voltage Testing voltage Ueff 50 Hz according to DIN VDE 0110-1, Table A.1 Safety class for casing / terminals according to DIN VDE 0470 Section 1:11.92 Interference resistance according to IEC 61000-4 Ambient temperature, work area Dimensional drawing Wiring diagram Weight Accessories Approvals 24 V 0.6 VA / 0.4 W 0.4 W – ≤ 110 mA approx. 80 mA 50 to 60 Hz 0.8 to 1.1 x UN 42 to +48 V 0.8 VA / 0.6 W 0.4 W – ≤ 110 mA approx. 80 mA 110 to 120 V 1.1 VA / 0.7 W 0.5 W – ≤ 40 mA approx. 30 mA –/– – 3s 30 ms – yes yes – – – – 1 contact, 1 "a" contact Ag, gold-mist-plated 230/230 V AC/DC 5A AC-15: Ue 230 V AC, Ie 3 A DC-13: Ue 24 V DC, Ie 2 A ≤ 1200 switching cycles/h 6 1 x 10 switching cycles ≤ 25 ms at AC, ≤ 10 ms at DC – according to DIN VDE 0110-1:04.97 4 kV III 3 exterior, 2 interior 250 V AC 2.21 kV IP 30 / IP 20 Test acuity 3 –20 to +60 °C K1-12 W3 KS 5189/2 0.12 kg – – Device overview / Order numbers Type KSP 12 Page 40 Rated voltage AC/DC 24 V 50-60 Hz AC/DC 42-48 V 50-60 Hz AC/DC 110-120 V 50-60 Hz AC/DC 220-240 V 50-60 Hz KSP 12 Order number R2.156.0019.2 R2.156.0029.2 R2.156.0039.2 R2.156.0049.2 220 to 240 V 1.1 VA / 0.7 W 0.4 W – ≤ 38 mA approx. 25 mA KMZ 71 / 72 KZL 72 KZL 71 KMZ 71 KMZ 72 Multi-function multi-range timer relay Multi voltage for AC/DC 24 up to 230 V 4 functions Setting range from 0.1 s to 120 h divided into 7 time ranges KZL 72 = 1 instantaneous and 1 timed change-over contact or 2 timed change-over contacts (selectable) • KZL 71 = 1 timed change-over contact • • • • Circuit diagram KMZ72 Time ranges Setting range from 0.1 s to 120 h divided into: 0.1 s … 1.2 s 0.1 h 1s … 12 s 1h 0.1 min … 1.2 min 10 h 1 min … 12 min … 1.2 … 12 … 120 h h h General information The functions and time ranges are set on the front through selector switches. KMZ71 Setting of the operating mode Rotate the operating mode selector switch with a screwdriver until the desired operating mode appears in the “MODE” display window. Functions for KZL 72, KZL 71: • A = ON-delay • B2 = repeat cycle starting with ON • E = interval ON • J = one shot (ON-delay) (AV) (TI) (EW) (AI) Setting of the time and time range factor Rotate the time selector switch located in the upper right corner of the control panel to set the desired time (sec., min. or hrs.) The time unit will be shown in the display window over the time selecting wheel. The time range factor (0.1 or 1) is set by rotating the selector switch located in the upper left corner of the operating panel. The selected time range factor will be shown in the display window above the selector switch. Setting of the operating time Use the time selecting wheel (ratio 0 – 12) to set the desired operating time. Setting of the contact assignment The function of the contacts for the model KZL 72 can be selected through a switch located at the bottom of the housing: 2 timed changeover contacts or 1 instantaneous and 1 timed change-over contact. KMZ 71 / 72 Page 41 KMZ 71 / 72 Function diagrams Displays and operating components 1 2 3 4 5 6 7 time range switch indicator (orange) (Lit while Time relay output.) Power ON LED (green) (Lit while the Voltage supply.) mode switch only KMZ 72: Switch INIT / TIME (default setting for timed output) * position for attaching the Users label main command for setting development time * If you leave the switch between the settings, is a proper operation may not be possible. Pay attention to the correct setting of the switch. Note: The factory setting is mode A and 0.1 s. Dimension diagram Page 42 KMZ 71 / 72 KMZ 71 / 72 Technical data Function type according to IEC 60050 (445) KZL 72 KZL 71 Function display Function diagrams Multi-function relay with 4 functions for multi-voltage – ON-delay timer relay – Interval ON relay – Repeat cycle starting with ON – One shot (ON-delay) relay 1 LED green, 1 LED orange FD 239-4/10 – 14 Power supply circuit Rated voltage UN Rated consumption at 50 Hz and UN 24 V AC Rated consumption at UN 24 V DC Rated consumption at 50 Hz and UN 230 V AC Rated consumption at UN 230 V DC Starting current inrush A1/A2 at 24 V DC Rated frequency Operating voltage range Release value der Excitation voltage A1/A2 AC/DC 24 – 230 V 1.1 VA / 0.9 W 0.9 W 2.7 VA / 1.7 W 1.4 W approx. 250 mA 50 – 60 Hz 0.85 – 1.1 x UN < 8 V AC/DC Time circuit Time setting / number of time ranges Available setting range Recovery time Repeatability Setting tolerance Influence of the energizing quantity or supply voltage Influence of the ambient temperature Analog / 7 See table "Time ranges" ≥ 100 ms ± 1 % + ± 10 ms average value of all measured values ± 10 % + ± 50 ms ± 0.5 % + ± 10 ms ± 2 % + ± 10 ms Output circuit Contact assignment Contact material Rated operating voltage Un Max. continuous current In Application category according to EN 60947-5-1:1991 Permissible switching frequency Mechanical life Electrical life General information Creepage distances and clearances between the circuits Rated impulse voltage Overvoltage category Degree of pollution Rated voltage Test voltage Ueff 50 Hz according to DIN VDE 0110-1, table A.1 Protection degree housing/terminal according to DIN VDE 0470 sec. 1:11.92 Noise immunity according to IEC 61000-4 Ambient temperature, operating range Dimension diagram Circuit diagram Weight Accessories 0.7 VA / 0.6 W 0.6 W 2.3 VA / 1.4 W 1.4 W 1 timed change-over contact 1 instantaneous and 1 timed change-over contact or 2 timed change-over contacts AgNi gold-flashed 230/125 V AC/DC 5A AC-13: Ue 250 V AC, Ie 5 A DC-13: Ue 24 V DC, Ie 0.1 A AC-15: Ue 250 V AC, Ie 3 A ≤ 3600 switching cycles/h 6 10 x 10 switching cycles 4 80 x 10 switching cycles at AC 5 A, 250 V, 360 switching cycles/h according to DIN VDE 0110-1:04.97 4 kV III 3 outside, 2 inside 250 V AC 2.21 kV IP 30 / IP 20 Test severity 3 –10 to +55 °C K1-16 KS 0328/4 0.12 kg – KS 0328/3 Overview of devices / Part numbers Type KMZ 71 KMZ 72 Rated voltage AC/DC 24-230 V 50-60 Hz AC/DC 24-230 V 50-60 Hz ON-delay time See table "Time ranges" See table "Time ranges" Part No. R2.066.0019.0 R2.066.0029.0 KMZ 71 / 72 Page 43 KMZ 91 / 92 KZL 92 KZL 91 KMZ 92 KMZ 91 Multi-function multi-range timer relay Multi voltage for AC/DC 24 up to 230 V 8 functions Setting range from 0.1 s to 120 h divided into 7 time ranges KMZ 92 = 1 instantaneous and 1 timed change-over contact or 2 timed change-over contacts (selectable) • KMZ 91 = 1 timed change-over contact • • • • Circuit diagram Time ranges Setting range from 0.1 s to 120 h divided into: 0.1 s … 1.2 s 0.1 h 1s … 12 s 1h 0.1 min … 1.2 min 10 h 1 min … 12 min KMZ92 … 1.2 … 12 … 120 h h h General information The functions and time ranges are set on the front through selector switches. Setting of the operating mode Rotate the operating mode selector switch with a screwdriver until the desired operating mode appears in the “MODE” display window. KMZ91 Functions for KMZ 92, KMZ 91: • A = ON-delay • B = repeat cycle starting with OFF • B2 = repeat cycle starting with ON • C = interval ON/OFF • D = OFF-delay • E = interval ON • G = ON-delay and OFF-delay • J = one shot (ON-delay) (AV) (TP) (TI) (EAW) (RV) (EW) (ARV) (AI) Setting of the time and time range factor Rotate the time selector switch located in the upper right corner of the operating panel to set the desired time (sec., min. or hrs.) The time unit will be shown in the display window over the time selecting wheel. The time range factor (0.1 or 1) is set by rotating the selector switch located in the upper left corner of the operating panel. The selected time range factor will be shown in the display window above the selector switch. Setting of the operating time Use the time selecting wheel (ratio 0 – 12) to set the desired operating time. Setting of the contact assignment The function of the contacts for the model KZL 92 can be selected through a switch located at the bottom of the housing: 2 timed changeover contacts or 1 instantaneous and 1 timed change-over contact. Page 44 KMZ 91 / 92 KMZ 91 / 92 Function diagrams Function diagrams Displays and operating components 1 2 3 4 5 6 7 time range switch indicator (orange) (Lit while Time relay output.) Power ON LED (green) (Lit while the Voltage supply.) mode switch only KMZ 92: Switch INIT / TIME (default setting for timed output) * position for attaching the Users label main command for setting development time * If you leave the switch between the settings, is a proper operation may not be possible. Pay attention to the correct setting of the switch. Note: The factory setting is mode A and 0.1 s. Dimension diagram KMZ 91 / 92 Page 45 KMZ 91 / 92 Technical data KZL 92 KZL 91 Function display Function diagrams Multi-function relay with 8 functions for multi-voltage – ON-delay timer relay – OFF-delay timer relay with supply voltage – Interval ON relay – ON-delay and OFF-delay timer relay – Repeat cycle starting with OFF/ON – Interval ON and OFF relay – One shot (ON-delay) relay 1 LED green, 1 LED orange FD 239-4/1 – 9 Power supply circuit Rated voltage UN Rated consumption at 50 Hz and UN 24 V AC Rated consumption at UN 24 V DC Rated consumption at 50 Hz and UN 230 V AC Rated consumption at UN 230 V DC Starting current inrush A1/A2 at 24 V DC Rated frequency Operating voltage range Rated current B1 - Input at 50 Hz and UN 24 V AC Rated current B1 - Input at UN 24 V DC Rated current B1 - Input at 50 Hz and UN 230 V AC Rated current B1 - Input at UN 230 V DC Minimum ON time B1 Excitation voltage B1 Release value of the Excitation voltage B1 AC/DC 24 – 230 V 1.1 VA / 0.9 W 0.7 VA / 0.5 W 0.8 W 0.5 W 2.8 VA / 1.6 W 2.3 VA / 1.5 W 1.6 W 1.4 W approx. 250 mA 50 – 60 Hz 0.85 to 1.1 x UN 0.1 mA 0.2 mA 0.8 mA 1.5 mA 50 ms High: 20.4 – 253 V AC/DC; Low: 0 – 2.4 V AC/DC < 8 V AC/DC Time circuit Time setting / number of time ranges Available setting range Recovery time Repeatability Setting tolerance Influence of the energizing quantity or supply voltage Influence of the ambient temperature Analog / 7 See table "Time ranges" ≥ 100 ms ± 1 % + ± 10 ms average value of all measured values ± 10 % + ± 50 ms ± 0.5 % + ± 10 ms ± 2 % + ± 10 ms Function type according to IEC 60050 (445) Output circuit Contact assignment Contact material Rated operating voltage Un Max. continuous current In Application category according to EN 60947-5-1:1991 Permissible switching frequency Mechanical life Electrical life General information Creepage distances and clearances between the circuits Rated impulse voltage Overvoltage category Degree of pollution Rated voltage Test voltage Ueff 50 Hz according to DIN VDE 0110-1, table A.1 Protection degree housing/terminal according to DIN VDE 0470 sec. 1:11.92 Noise immunity according to IEC 61000-4 Ambient temperature, operating range Dimension diagram Circuit diagram Weight Accessories 1 timed change-over contact 1 instantaneous and 1 timed change-over contact or 2 timed change-over contacts AgNi gold-flashed 230/125 V AC/DC 5A AC-13: Ue 250 V AC, Ie 5 A DC-13: Ue 24 V DC, Ie 0.1 A AC-15: Ue 250 V AC, Ie 3 A ≤ 3600 switching cycles/h 6 10 x 10 switching cycles 4 80 x 10 switching cycles at AC 5 A, 250 V, 360 switching cycles/h according to DIN VDE 0110-1:04.97 4 kV III 2 outside, 2 inside 250 V AC 2.21 kV IP 30 / IP 20 Test severity 3 –10 to +55 °C K1-16 KS 0328/2 0.12 kg – KS 0328/1 Overview of devices / Part numbers Type KMZ 91 KMZ 92 Page 46 Rated voltage AC/DC 24-230 V 50-60 Hz AC/DC 24-230 V 50-60 Hz KMZ 91 / 92 ON-delay time See table "Time ranges" See table "Time ranges" Part No. R2.066.0039.1 R2.066.0049.0 KZTH 11 KZTH 11 ON-delay single-range timer relay with semiconductor output (two-wire) • • • • Multi voltage AC/DC 24 to 110 or 60 to 230 V 1 function: ON-delay (AV) 1 time range 1 semiconductor output Circuit diagram Time ranges Available time ranges: 0.05 s … 1 s 0.15 s … 3 s 0.5 s … 10 s 1.5 s … 30 s 5s … 100 s Function Function diagrams Infinitely variable time setting is selected with a thumbwheel disc. The scale values are absolute values related to the selected time unit. Application example Dimension diagram When the control contact S is closed, the KZTH 11 is energized through the load L and the countdown starts (see “Function diagram”). After the timing period has elapsed, the KZTH 11 connects the load L. The load L must be chosen so that even with lower supply voltage the holding current will not fall below 10 mAeff and the maximum load current is ≤ 0.8 Aeff. At max. load current, a voltage drop ≤ 3.5 Veff must be considered due to the KZTH. KZTH 11 Page 47 DZ KZTH 11 Technical data KZTH 11 Function type according to IEC 60050 (445) Function display Function diagrams ON-delay timer relay with semiconductor output for multi-voltage – FD 0034 Power supply circuit Rated voltage UN Rated consumption at 50 Hz and UN (AC) Rated consumption DC Starting current inrush stroke Rated frequency Operating voltage range AC/DC 24 – 110 V – – – 50 – 60 Hz 0.8 – 1.1 x UN 60 – 230 V – – – Time circuit Time setting / number of time ranges Available setting range Recovery time 1/2 Minimum on time Release value Parallel loads permissible Internal half-wave rectification Mean value of the error Dispersion Influence of the energizing quantity, supply voltage Influence of the ambient temperature analogous/ 1 See table "Time ranges" approx. 50 / approx. 300 ms – – No No – ≤ ± 1 % + ± 10 ms – ≤ 0.15 % / K Output circuit Contact assignment Contact material Rated operating voltage Un Max. load current Max. impulse current, 1 half wave 50 Hz Holding current Voltage drop in the device Permissible switching frequency Response time Release time 1 semiconductor – – 0.8 Aeff 30 As ≤ 15 mAeff ≤ 3.5 mVeff ≤ 3600 switching cycles/h – – General information Creepage distances and clearances between the circuits Rated impulse voltage Overvoltage category Degree of pollution Rated voltage Test voltage Ueff 50 Hz according to DIN VDE 0110-1, table A.1 Protection degree housing/terminal according to DIN VDE 0470 sec. 1:11.92 Noise immunity according to IEC 61000-4 Ambient temperature, operating range Dimension diagram Circuit diagram Weight Accessories Approvals according to DIN VDE 0110-1:04.97 – – 3 outside, 2 inside – – IP 30 / IP 20 Test severity 3 –20 to +60 °C K1-7 KS 0164/2 0.11 kg – – Overview of devices / Part numbers Type KZTH 11 Page 48 Rated voltage AC/DC 60-230 V AC/DC 24-110 V AC/DC 60-230 V AC/DC 24-110 V AC/DC 60-230 V AC/DC 60-230 V AC/DC 60-230 V KZTH 11 50-60 Hz 50-60 Hz 50-60 Hz 50-60 Hz 50-60 Hz 50-60 Hz 50-60 Hz ON-delay time 0.05 ... 1 s 0.15 ... 3 s 0.5 ... 10 s 1.5 ... 30 s 5 … 100 s Part No. R2.060.0069.2 R2.060.0089.2 R2.060.0099.2 R2.060.0049.2 R2.060.0059.2 R2.060.0079.2 R2.060.0039.2 NGB 12 NGB 12 Fixed time flasher relay • • • • • Multi-voltage for AC/DC 24 to 240 V 1 function: symmetrical flashing, starts OFF Fixed time 0.5 s / 0.5 s 2 change-over contact 2 LEDs for function display Circuit diagram Time ranges Fixed time 0.5 s / 0.5 s Function ON-delay time The NGB 12 timer relay is available with fixed ON and OFF time. ON time = 0.5 s OFF time = 0.5 s Function diagrams LEDs show the state of the excitation input and the position of the contacts. You can monitor the countdown on a flashing LED. Notes The device is designed for multi-voltage. Phase L1 or L+ must be connected to terminal A1; neutral conductor N or M must be connected to terminal A2. Dimension diagram NGB 12 Page 49 NGB 12 Technical data NGB 12 Product standard (timer relays) Function type of the relay according to IEC 60050 Function display Function diagrams EN 61812-1:1999-08 445-01-06 2 LEDs green FD 250-33 Input circuit Rated voltage A1-A2 Rated consumption AC Rated consumption DC Rated voltage limits Rated frequency fn Release value of the input voltage (power capacity approx. 150 pF/m) Rated current on control connection (A1) Rated consumption on control connection (A1) Parallel loads permissible Internal half-wave rectification AC/DC 24 – 240 V 3.5 VA / 1.7 W 1.6 W 70 – 110 % 50 – 60 Hz ± 5 % ≥ AC/DC 10 V; permissible line capacity 0.2 µF 1 mA < 0.25 W A1-A2 yes A1-A2 no Time circuit Time setting / number of time ranges Setting ranges for time delay Cycle start Recovery time 1/2 Repeatability (to set value) Influence of temperature (within range) Influence of voltage (within range) analog / 1 Fixed time 0.5 s / 0.5 s Pause ≤ 50 / ≤ 50 ms ≤ ± 0.01 % + ± 10 ms ≤ ± 0.002 % ≤ ± 0.002 % Output circuit Contact assignment Contact material Rated operating voltage Rated value for limiting continuous current Ith Minimum contact load Application category according to IEC 60947-5-1 Permissible switching frequency Mechanical life Electrical life 20/2 A, AC 250 V, cos ϕ = 0.3 Response time / release time at excitation of A1-A2 2 change-over contacts AgNi 90/10 AC/DC 24 – 240 V 5A ≥ AC/DC 5 V / ≥ 10 mA AC-15 Ue AC 230 V, Ie 3 A DC-13 Ue DC 24 V, Ie 2 A ≤ 3600 switching cycles/h 6 30 x 10 switching cycles 6 0.12 x 10 switching cycles AC-15 40 ms Other data Creepage distances and clearances Degree of pollution Overvoltage category Rated voltage Degree of protection according to IEC 60529 housing/terminals Noise immunity according to IEC 61000-4 Ambient temperature, operating range Dimension diagram (housing) Circuit diagram of the terminals Wire ranges stranded or solid stranded with ferrules Weight Accessories according to IEC 60664-1 3 outside, 2 inside III AC/DC 275 V IP 40 / IP 20 Test severity 3 -25 – +60 °C K 3-2 KS 250-20 2 1 x 0.2 – 6 or 2 x 0.2 to 2.5 mm 2 1 x 0.4 – 4 or 2 x 0.2 to 1.5 mm 0.11 kg – Overview of devices / Part numbers Type NGB 12 Page 50 Rated voltage AC/DC 24-240 V 50-60 Hz NGB 12 ON-delay time 0.5 s / 0.5 s Part No. R2.105.0029.0 NGD 31 NGD 31 Interval ON star-delta relay • • • • • Multi voltage for AC/DC 24 up to 240 V 1 function: star-delta switching, interval ON (EW) 4 time ranges available from 0.1 s to 100 s 2 normally open contacts 2 LEDs for function display Circuit diagram Time ranges Available time ranges: <0.1 ... 1 0.5 ... 10 1.5 ... 30 5 ... 100 s s s s Function Setting the time delay The desired delay time is set with a selecting wheel. It can be set using a screwdriver. Function diagrams Method of operation: The NGD 31 has two sequentially switching delayed outputs for starting motors in star-delta mode. After expiration of the pre-selected acceleration time tH for the star mode and a fixed transit time tU the second contact switches into the operating position for the delta mode. When the energizing quantity switches off the contact switches into the OFF position. The LEDs shows the switching position of the contacts. The countdown can be monitored on the LEDs. Notes The device is designed for multi-voltage. Phase L1 or L+ must be connected to terminal A1; neutral conductor N or M must be connected to terminal A2. You can change the delay time during operation. The change is effective immediately. Dimension diagram NGD 31 Page 51 NGD 31 Technical data NGD 31 Product standard (timer relays) Function type of the relay according to IEC 60050 Function display Function diagrams EN 61812-1:1999-08 445-01-10 + 445-01-08 2 LEDs green FD 250-44 Input circuit Rated voltage A1-A2 Rated consumption AC Rated consumption DC Rated voltage limits Rated frequency fn Release value of the input voltage (power capacity approx. 150 pF/m) Rated current on control connection (A1) Rated consumption on control connection (A1) Parallel loads permissible Internal half-wave rectification AC/DC 24 – 240 V 3.5 VA / 1.7 W 1.6 W 70 – 110 % 50 – 60 Hz ± 5 % ≥ AC/DC 10 V; permissible line capacity 0.2 µF 1 mA < 0.25 W A1-A2 yes A1-A2 no Time circuit Time setting / number of time ranges Setting ranges for time delay Constant fixed transition time Setting tolerance Repeatability (to set value) Influence of temperature (within range) Influence of voltage (within range) analogous/ 1 See table "Time ranges" 100 ms ≤ ± 2 % ≤±5% ≤ ± 0.01 % + ± 10 ms ≤ ± 0.002 % ≤ ± 0.002 % Output circuit Contact assignment Contact material Rated operating voltage Rated value for limiting continuous current Ith Minimum contact load Application category according to IEC 60947-5-1 Permissible switching frequency Mechanical life Electrical life 20/2 A, AC 250 V, cos ϕ = 0.3 Response time / release time at excitation of A1-A2 2 normally open contacts AgNi 90/10 AC/DC 24 – 240 V 5A ≥ AC/DC 5 V / ≥ 10 mA AC-15 Ue AC 230 V, Ie 3 A DC-13 Ue DC 24 V, Ie 2 A ≤ 3600 switching cycles/h 6 30 x 10 switching cycles 6 0.12 x 10 switching cycles AC-15 40 ms Other data Creepage distances and clearances Degree of pollution Overvoltage category Rated voltage Degree of protection according to IEC 60529 housing/terminals Noise immunity according to IEC 61000-4 Ambient temperature, operating range Dimension diagram (housing) Circuit diagram of the terminals Wire ranges stranded or solid stranded with ferrules Weight Accessories according to IEC 60664-1 3 outside, 2 inside III AC/DC 275 V IP 40 / IP 20 Test severity 3 -25 – +60 °C K 3-2 KS 250-21 2 1 x 0.2 – 6 or 2 x 0.2 to 2.5 mm 2 1 x 0.4 – 4 or 2 x 0.2 to 1.5 mm 0.11 kg – Overview of devices / Part numbers Type NGD 31 Page 52 Rated voltage AC/DC 24-240 V 50-60 Hz NGD 31 ON-delay time <0.1 ... 1 0.5 ... 10 1.5 ... 30 5 ... 100 s s s s Part No. R2.062.0039.0 R2.062.0029.0 R2.062.0049.0 R2.062.0019.0 NGM 1004 NGM 1004 Multi-function multi-range timer relay • • • • • Multi voltage for AC/DC 24 up to 240 V 10 functions Setting range from 0.1 s to 300 h divided into 16 selectable time ranges 1 change-over contact 2 LEDs for function display Circuit diagram Time ranges Setting range from 0.1 s to 300 h divided into: <0.1 ... 1 s 5 ... 100 s 1.5 ... 30 min 0.15 ... 3 s 15 ... 300 s 3 ... 60 min 0.5 ... 10 s 50 ... 1000 s 5 ... 100 min 1.5 ... 30 s 0.5 ... 10 min 0.15 ... 3 h 0.5 ... 1.5 ... 5 ... 15 ... 10 30 100 300 h h h h Function Function diagrams See the following pages for the function diagrams Setting the function The function is set with the MODE selector switch and displayed by the function code in the window next to it. The code designation for the function can be found in the column “Function diagrams”. Setting the time delay The time range is set with the RANGE selector switch and displayed in the window next to it. The desired delay time is set with a selecting wheel. LEDs show the state of the excitation input and the position of the contacts. You can monitor the countdown on a flashing LED. Notes • The device is designed for multi-voltage. Connect phase L1 or L+ to terminal A1 and B1 and neutral N and/or M to terminal A2. • You can change the function or delay time during operation. The change is effective immediately. Dimension diagram NGM 1004 Page 53 NGM 1004 Function diagrams Page 54 NGM 1004 Function diagrams NGM 1004 Function diagrams Function codes / times Functioncode 11 11-C 12 21 22 44 81C-1s 81C-2s 82 83-1s Functiondiagram 250-6 250-7 250-10 250-26 250-28 250-43 250-55 250-55 250-56 250-59 Recovery time (ms) 1 ≤ 50 ≤ 50 0 ≤ 50 – ≤ 50 ≤ 50 ≤ 50 0 ≤ 50 2 ≤ 50 ≤ 25 0 ≤ 50 – – ≤ 25 ≤ 25 0 – 3 – – – – – – 0 0 – – Minimum ON time (ms) 1 2 ≤ 25 – – – ≤ 25 – ≤ 25 – ≤ 25 ≤ 50 ≤ 25 – – – – – ≤ 25 – ≤ 25 – NGM 1004 Page 55 NGM 1004 Technical data NGM 1004 Product standard (timer relays) Relay function according to IEC 60050 (445) Function display Function diagrams EN 61812-1:1999-08 Multi-function relay with multi-time range 2 LEDs green See column "Function diagrams" Input circuit Rated voltage A1-A2 Rated consumption AC Rated consumption DC Rated voltage limits Rated frequency fn Release value of the input voltage (power capacity approx. 150 pF/m) Rated current on control connection (B1-A2) Rated consumption on control connection (B1-A2) Parallel loads permissible Internal half-wave rectification AC/DC 24 – 240 V 3.5 VA / 1.7 W 1.6 W 70 – 110 % 50 – 60 Hz ± 5 % ≥ AC/DC 10 V; permissible line capacity 0.2 µF 1 mA < 0.25 W A1-A2 yes / B1-A2 yes A1-A2 no / B1-A2 yes Time circuit Time setting / number of time ranges Setting ranges for time delay Recovery time 1/2/3 Minimum ON time 1/2 Setting tolerance Repeatability (to set value) Influence of temperature (within range) Influence of voltage (within range) analogous/ 16 See table "Time ranges" See table "Function codes / times" See table "Function codes / times" ≤±5% ≤ ± 0.01 % + ± 10 ms ≤ ± 0.002 % ≤ ± 0.002 % Output circuit Contact assignment Contact material Rated operating voltage Rated value for limiting continuous current Ith Minimum contact load Application category according to IEC 60947-5-1 Permissible switching frequency Mechanical life Electrical life 20/2 A, AC 250 V, cos ϕ = 0.3 Response time / release time at excitation of A1-A2 Response time / release time at excitation of B1-A2 1 change-over contacts AgNi 90/10 AC/DC 24 – 240 V 5A ≥ AC/DC 5 V / ≥ 10 mA AC-15 Ue AC 230 V, Ie 3 A DC-13 Ue DC 24 V, Ie 2 A ≤ 3600 switching cycles/h 6 30 x 10 switching cycles 6 0.12 x 10 switching cycles AC-15 40 ms 20 ms Other data Creepage distances and clearances Degree of pollution Overvoltage category Rated voltage Degree of protection according to IEC 60529 housing/terminals Noise immunity according to IEC 61000-4 Ambient temperature, operating range Dimension diagram (housing) Circuit diagram of the terminals Wire ranges stranded or solid stranded with ferrules Weight Accessories according to IEC 60664-1 3 outside, 2 inside III AC/DC 275 V IP 40 / IP 20 Test severity 3 -25 – +60 °C K 3-1 KS 250-30 2 1 x 0.2 – 6 or 2 x 0.2 to 2.5 mm 2 1 x 0.4 – 4 or 2 x 0.2 to 1.5 mm 0.1 kg – Overview of devices / Part numbers Type NGM 1004 Page 56 Rated voltage AC/DC 24-240 V 50-60 Hz NGM 1004 ON-delay time See table "Time ranges" Part No. R2.065.0039.0 NGM 1600 NGM 1600 Multi-function multi-range timer relay Multi voltage for AC/DC 24 up to 240 V 16 functions Setting range from 0.1 s to 300 h divided into 16 selectable time ranges 2 change-over contacts or 1 instantaneous change-over contact and 1 timed change-over contact (function-dependent) • 3 LEDs for function display • • • • Circuit diagram Time ranges Setting range from 0.1 s to 300 h divided into: <0.1 ... 1 s 5 ... 100 s 1.5 ... 30 min 0.15 ... 3 s 15 ... 300 s 3 ... 60 min 0.5 ... 10 s 50 ... 1000 s 5 ... 100 min 1.5 ... 30 s 0.5 ... 10 min 0.15 ... 3 h 0.5 ... 1.5 ... 5 ... 15 ... 10 30 100 300 h h h h Function Setting the function The function is set with the MODE selector switch and displayed by the function code in the window next to it. The code designation for the function can be found in the column “Function diagrams”. Function diagrams See the following pages for the function diagrams Setting the time delay The time range is set with the RANGE selector switch and displayed in the window next to it. The desired delay time is set with a selecting wheel. LEDs show the state of the excitation input and the position of the contacts. You can monitor the countdown on a flashing LED. Notes • The device is designed for multi-voltage. Connect phase L1 or L+ to terminal A1 and B1 and neutral N and/or M to terminal A2. • You can change the function or delay time during operation. The change is effective immediately. Dimension diagram NGM 1600 Page 57 NGM 1600 Function diagrams Page 58 NGM 1600 Function diagrams NGM 1600 Function diagrams Function diagrams Function codes / times Function code 11 11-ON 11C-ON 12 12-ON 11-12 12-22 21 21-ON 21-22 22-ON 43-44 51 81-1s-ON 82-ON 83-84-1s Function diagram 250-3 250-5 250-8 250-12 205-13 250-14 250-15 250-21 250-25 250-27 250-29 250-41 250-46 250-53 250-57 250-60 Recovery time (ms) 1 ≤ 50 ≤ 50 ≤ 50 0 0 ≤ 25 0 ≤ 50 ≤ 50 ≤ 25 ≤ 50 ≤ 50 2 ≤ 50 ≤ 50 ≤ 50 0 0 0 tWA+0 ≤ 50 ≤ 50 – ≤ 50 ≤ 50 ≤ 50 0 ≤ 50 ≤ 50 0 – NGM 1600 3 – – – – – – – – – – – – – – – – Minimum ON time (ms) 1 2 – – – – – – ≤ 25 ≤ 25 ≤ 25 ≤ 25 ≤ 25 – ≤ 25 – – – – – ≤ 25 – – – – – – – – – ≤ 25 – – – Page 59 NGM 1600 Technical data NGM 1600 Product standard (timer relays) Relay function according to IEC 60050 (445) Function display Function diagrams EN 61812-1:1999-08 Multi-function relay with multi-time range 3 LEDs green See column "Function diagrams" Input circuit Rated voltage A1-A2 Rated consumption AC Rated consumption DC Rated voltage limits Rated frequency fn Release value of the input voltage (power capacity approx. 150 pF/m) Rated current on control connection (B1-A2) Rated consumption on control connection (B1-A2) Parallel loads permissible Internal half-wave rectification AC/DC 24 – 240 V 3.5 VA / 1.7 W 1.6 W 70 – 110 % 50 – 60 Hz ± 5 % ≥ AC/DC 10 V; permissible line capacity 0.2 µF 1 mA < 0.25 W A1-A2 yes / B1-A2 yes A1-A2 no / B1-A2 yes Time circuit Time setting / number of time ranges Setting ranges for time delay Recovery time 1/2/3 Minimum ON time 1/2 Setting tolerance Repeatability (to set value) Influence of temperature (within range) Influence of voltage (within range) analogous/ 16 See table "Time ranges" See table "Function codes / times" See table "Function codes / times" ≤±5% ≤ ± 0.01 % + ± 10 ms ≤ ± 0.002 % ≤ ± 0.002 % Output circuit Contact assignment Contact material Rated operating voltage Rated value for limiting continuous current Ith Minimum contact load Application category according to IEC 60947-5-1 Permissible switching frequency Mechanical life Electrical life 20/2 A, AC 250 V, cos ϕ = 0.3 Response time / release time at excitation of A1-A2 Response time / release time at excitation of B1-A2 2 change-over contacts AgNi 90/10 AC/DC 24 – 240 V 5A ≥ AC/DC 5 V / ≥ 10 mA AC-15 Ue AC 230 V, Ie 3 A DC-13 Ue DC 24 V, Ie 2 A ≤ 3600 switching cycles/h 6 30 x 10 switching cycles 6 0.12 x 10 switching cycles AC-15 40 ms 20 ms Other data Creepage distances and clearances Degree of pollution Overvoltage category Rated voltage Degree of protection according to IEC 60529 housing/terminals Noise immunity according to IEC 61000-4 Ambient temperature, operating range Dimension diagram (housing) Circuit diagram of the terminals Wire ranges stranded or solid stranded with ferrules Weight Accessories according to IEC 60664-1 3 outside, 2 inside III AC/DC 275 V IP 40 / IP 20 Test severity 3 –25 to +60 °C K 3-3 KS 250-31 2 1 x 0.2 – 6 or 2 x 0.2 to 2.5 mm 2 1 x 0.4 – 4 or 2 x 0.2 to 1.5 mm 0.13 kg – Overview of devices / Part numbers Type NGM 1600 Page 60 Rated voltage AC/DC 24-240 V 50-60 Hz NGM 1600 ON-delay time See table "Time ranges" Part No. R2.065.0040.0 NGS 12 NGS 12 Electronic coupling relays • • • • 4 mono voltages AC/DC available 1 function: coupling relay 2 change-over contacts 1 LED for function control Circuit diagram Function By applying supply voltage to terminals A1 and A2, the two change-over contacts switch into the ON position. If the supply voltage is switched off, they will switch back into the OFF position. The LED shows the switching position of the contacts. Notes Phase L1 or L+ must be connected to terminal A1; neutral conductor N or M must be connected to terminal A2. Function diagrams The internal switching relays are controlled electronically in order to ensure safe switching of the coupling relays even under the most difficult conditions. External connection to freewheeling diodes or RC combinations is not required, as the relays are wired internally accordingly. Dimension diagram NGS 12 Page 61 NGS 12 Technical data Product standard Function type according to IEC 60050 Function display Function diagrams NGS 12 EN 618122-1:1999-08 Item 2.1: switching relays 1 LED green FD 242-1 Input circuit Rated voltage UN Rated consumption at 50 Hz Rated consumption at 60 Hz Rated consumption DC Switch-on peak Rated voltage limits Rated frequency fn Release value of the input voltage (power capacity approx. 150 pF/m) Parallel loads permissible Internal half-wave rectification Output circuit Contact assignment Contact material Rated operating voltage Rated value for limiting continuous current Ith Minimum contact voltage Application category according to IEC 60947-5-1 AC/DC AC/DC AC/DC 24 V 28 V 110-127 V 1.1 VA / 1.0 W 1.2 VA / 1.0 W 1.7 VA / 1.4 W 1.1 VA / 1.0 W 1.2 VA / 1.0 W 1.7 VA / 1.4 W 1.0 W 1.1 W 1.1 W 0.3 A / 0.5 ms 0.3 A / 0.5 ms 0.3 A / 0.2 ms 80 – 110 % 50 – 60 Hz ± 5 % ≥ 15 % UN; permissible line capacity 0.2 µF A1-A2 yes A1-A2 no Permissible switching frequency Mechanical life Electrical life 20/2 A, AC 250 V, cos ϕ = 0.3 Response time / release time at excitation of A1-A2 2 change-over contacts Ag with 2 to 5 μm Au AC/DC 250 V 5A AC/DC 15 V AC-15 Ue AC 230 V, Ie 3 A DC-13 Ue DC 24 V, Ie 2 A ≤ 3600 switching cycles/h 6 30 x 10 switching cycles 6 0.12 x 10 switching cycles AC-15 10 ms / 13 ms Other data Creepage distances and clearances Degree of pollution Overvoltage category Rated voltage Degree of protection according to IEC 60529 housing/terminals Ambient temperature, operating range Dimension diagram (housing) Circuit diagram of the terminals Wire ranges stranded or solid stranded with ferrules Weight Accessories Approvals according to IEC 60664-1 3 outside, 2 inside III 250 V IP 40 / IP 20 -25 – +60 °C K 3-3 KS 242-1 2 1 x 0.2 – 6 or 2 x 0.2 to 2.5 mm 2 1 x 0.4 – 4 or 2 x 0.2 to 1.5 mm 0.12 kg – – Overview of devices / Part numbers Type NGS 12 Page 62 Rated voltage AC/DC 24 V 50-60 Hz AC/DC 28 V 50-60 Hz AC/DC 220-240 V 50-60 Hz AC 110-127 V 50-60 Hz NGS 12 ON-delay time – – – – Part No. R2.154.0039.0 R2.154.0049.0 R2.154.0029.0 R2.154.0019.0 AC/DC 220-240 V 1.9 VA / 1.6 W 2.0 VA / 1.7 W 1.6 W 0.2 A / 0.1 ms NGZ 11 NGZ 11 ON-delay single-range timer relay • • • • • Multi voltage for AC/DC 24 up to 240 V 1 function: ON-delay (AV) 13 time ranges available from 0.1 s to 100 h 1 change-over contact 2 LEDs for function display Circuit diagram Time ranges Available time ranges: <0.1 ... 1 s 5 ... 100 s 0.15 ... 3 s 15 ... 300 s 0.5 ... 10 s 50 ... 1000 s 1.5 ... 30 s 0.5 ... 10 min 1.5 ... 30 min 3 ... 60 min 0.5 ... 10 h 1.5 ... 30 h 5 ... 100 h Function Setting the time delay The desired delay time is set with a selecting wheel. It can be set using a screwdriver. Function diagrams LEDs show the state of the excitation input and the position of the contacts. You can monitor the countdown on a flashing LED. Notes The device is designed for multi-voltage. Phase L1 or L+ must be connected to terminal A1; neutral conductor N or M must be connected to terminal A2. You can change the delay time during operation. The change is effective immediately. Dimension diagram Subject to change without further notice NGZ 11 Page 63 NGZ 11 Technical data NGZ 11 Product standard (timer relays) Function type of the relay according to IEC 60050 Function display Function diagrams EN 61812-1:1999-08 445-01-02 2 LEDs green FD 250-1 Input circuit Rated voltage A1-A2 Rated consumption AC Rated consumption DC Rated voltage limits Rated frequency fn Release value of the input voltage (power capacity approx. 150 pF/m) Rated current on control connection (A1) Rated consumption on control connection (A1) Parallel loads permissible Internal half-wave rectification AC/DC 24 – 240 V 3.5 VA / 1.7 W 1.6 W 70 – 110 % 50 – 60 Hz ± 5 % ≥ AC/DC 10 V; permissible line capacity 0.2 µF 1 mA < 0,25 W A1-A2 yes A1-A2 no Time circuit Time setting / number of time ranges Setting ranges for time delay Recovery time 1/2 Minimum ON time 1/2 Setting tolerance Repeatability (to set value) Influence of temperature (within range) Influence of voltage (within range) analogous/ 1 See table "Time ranges" ≤ 50 / ≤ 50 ms – / – ms ≤±5% ≤ ± 0,01 % + ± 10 ms ≤ ± 0,002 % ≤ ± 0,002 % Output circuit Contact assignment Contact material Rated operating voltage Rated value for limiting continuous current Ith Minimum contact load Application category according to IEC 60947-5-1 Permissible switching frequency Mechanical life Electrical life 20/2 A, AC 250 V, cos ϕ = 0.3 Response time / release time at excitation of A1-A2 1 change-over contacts AgNi 90/10 AC/DC 24 – 240 V 5A ≥ AC/DC 5 V / ≥ 10 mA AC-15 Ue AC 230 V, Ie 3 A DC-13 Ue DC 24 V, Ie 2 A ≤ 3600 switching cycles/h 6 30 x 10 switching cycles 6 0.12 x 10 switching cycles AC-15 40 ms Other data Creepage distances and clearances Degree of pollution Overvoltage category Rated voltage Degree of protection according to IEC 60529 housing/terminals Noise immunity according to IEC 61000-4 Ambient temperature, operating range Dimension diagram (housing) Circuit diagram of the terminals Wire ranges stranded or solid stranded with ferrules Weight Accessories according to IEC 60664-1 3 outside, 2 inside III AC/DC 275 V IP 40 / IP 20 Test severity 3 -25 – +60 °C K 3-1 KS 250-1 2 1 x 0.2 – 6 or 2 x 0.2 to 2.5 mm 2 1 x 0.4 – 4 or 2 x 0.2 to 1.5 mm 0.1 kg – Overview of devices / Part numbers Type NGZ 11 Page 64 Rated voltage AC/DC 24-240 V 50-60 Hz NGZ 11 ON-delay time <0.1 ... 1 0.15 ... 3 0.5 ... 10 1.5 ... 30 5 ... 100 15 ... 300 50 ... 1000 0.5 ... 10 1.5 ... 30 3 ... 60 0.5 ... 10 1.5 ... 30 5 ... 100 s s s s s s s min min min h h h Part No. R2.064.0079.0 R2.064.0129.0 R2.064.0069.0 R2.064.0119.0 R2.064.0079.0 R2.064.0039.0 R2.064.0019.0 R2.064.0059.0 R2.064.0109.0 R2.064.0139.0 R2.064.0049.0 R2.064.0099.0 R2.064.0029.0 Subject to change without further notice NGZ 12 NGZ 12 ON-delay single-range timer relay • • • • • Multi voltage for AC/DC 24 up to 240 V 1 function: ON-delay (AV) 13 time ranges available from 0.1 s to 100 h 2 change-over contact 2 LEDs for function display Circuit diagram Time ranges Available time ranges: <0.1 ... 1 s 5 ... 100 s 0.15 ... 3 s 15 ... 300 s 0.5 ... 10 s 50 ... 1000 s 1.5 ... 30 s 0.5 ... 10 min 1.5 ... 30 min 3 ... 60 min 0.5 ... 10 h 1.5 ... 30 h 5 ... 100 h Function Setting the time delay The desired delay time is set with a selecting wheel. It can be set using a screwdriver. Function diagrams LEDs show the state of the excitation input and the position of the contacts. You can monitor the countdown on a flashing LED. Notes The device is designed for multi-voltage. Phase L1 or L+ must be connected to terminal A1; neutral conductor N or M must be connected to terminal A2. You can change the delay time during operation. The change is effective immediately. Dimension diagram Subject to change without further notice NGZ 12 Page 65 NGZ 12 Technical data NGZ 12 Product standard (timer relays) Function type of the relay according to IEC 60050 Function display Function diagrams EN 61812-1:1999-08 445-01-02 2 LEDs green FD 250-2 Input circuit Rated voltage A1-A2 Rated consumption AC Rated consumption DC Rated voltage limits Rated frequency fn Release value of the input voltage (power capacity approx. 150 pF/m) Rated current on control connection (A1) Rated consumption on control connection (A1) Parallel loads permissible Internal half-wave rectification AC/DC 24 – 240 V 3.5 VA / 1.7 W 1.6 W 70 – 110 % 50 – 60 Hz ± 5 % ≥ AC/DC 10 V; permissible line capacity 0.2 µF 1 mA < 0.25 W A1-A2 yes A1-A2 no Time circuit Time setting / number of time ranges Setting ranges for time delay Recovery time 1/2 Minimum ON time 1/2 Setting tolerance Repeatability (to set value) Influence of temperature (within range) Influence of voltage (within range) analogous/ 1 See table "Time ranges" ≤ 50 / ≤ 50 ms –/– ≤±5% ≤ ± 0.01 % + ± 10 ms ≤ ± 0.002 % ≤ ± 0.002 % Output circuit Contact assignment Contact material Rated operating voltage Rated value for limiting continuous current Ith Minimum contact load Application category according to IEC 60947-5-1 Permissible switching frequency Mechanical life Electrical life 20/2 A, AC 250 V, cos ϕ = 0.3 Response time / release time at excitation of A1-A2 2 change-over contacts AgNi 90/10 AC/DC 24 – 240 V 5A ≥ AC/DC 5 V / ≥ 10 mA AC-15 Ue AC 230 V, Ie 3 A DC-13 Ue DC 24 V, Ie 2 A ≤ 3600 switching cycles/h 6 30 x 10 switching cycles 6 0.12 x 10 switching cycles AC-15 40 ms Other data Creepage distances and clearances Degree of pollution Overvoltage category Rated voltage Degree of protection according to IEC 60529 housing/terminals Noise immunity according to IEC 61000-4 Ambient temperature, operating range Dimension diagram (housing) Circuit diagram of the terminals Wire ranges stranded or solid stranded with ferrules Weight Accessories according to IEC 60664-1 3 outside, 2 inside III AC/DC 275 V IP 40 / IP 20 Test severity 3 -25 – +60 °C K 3-2 KS 250-3 2 1 x 0.2 – 6 or 2 x 0.2 to 2.5 mm 2 1 x 0.4 – 4 or 2 x 0.2 to 1.5 mm 0.11 kg – Overview of devices / Part numbers Type NGZ 12 Page 66 Rated voltage AC/DC 24-240 V 50-60 Hz NGZ 12 ON-delay time <0.1 ... 1 0.15 ... 3 0.5 ... 10 1.5 ... 30 5 ... 100 15 ... 300 50 ... 1000 0.5 ... 10 1.5 ... 30 3 ... 60 0.5 ... 10 1.5 ... 30 5 ... 100 s s s s s s s min min min h h h Part No. R2.064.0219.0 R2.064.0269.0 R2.064.0209.0 R2.064.0259.0 R2.064.0179.0 R2.064.0229.0 R2.064.0159.0 R2.064.0199.0 R2.064.0249.0 R2.064.0279.0 R2.064.0189.0 R2.064.0239.0 R2.064.0169.0 Subject to change without further notice NGZ 12 S NGZ 12 S ON-delay single-range timer relay • • • • • Multi voltage for AC/DC 24 up to 240 V 1 function: ON-delay (AV) 13 time ranges available from 0.1 s to 100 h 1 instantaneous and 1 timed change-over contact 2 LEDs for function display Circuit diagram Time ranges Available time ranges: <0.1 ... 1 s 5 ... 100 s 0.15 ... 3 s 15 ... 300 s 0.5 ... 10 s 50 ... 1000 s 1.5 ... 30 s 0.5 ... 10 min 1.5 ... 30 min 3 ... 60 min 0.5 ... 10 h 1.5 ... 30 h 5 ... 100 h Function Setting the time delay The desired delay time is set with a selecting wheel. It can be set using a screwdriver. Function diagrams LEDs show the state of the excitation input and the position of the contacts. You can monitor the countdown on a flashing LED. Notes The device is designed for multi-voltage. Phase L1 or L+ must be connected to terminal A1; neutral conductor N or M must be connected to terminal A2. You can change the delay time during operation. The change is effective immediately. Dimension diagram Subject to change without further notice NGZ 12 S Page 67 DZ NGZ 12 S Technical data NGZ 12-S Product standard (timer relays) Function type of the relay according to IEC 60050 Function display Function diagrams EN 61812-1:1999-08 445-01-02 + 445-04-05 2 LEDs green FD 250-4 Input circuit Rated voltage A1-A2 Rated consumption AC Rated consumption DC Rated voltage limits Rated frequency fn Release value of the input voltage (power capacity approx. 150 pF/m) Rated current on control connection (A1) Rated consumption on control connection (A1) Parallel loads permissible Internal half-wave rectification AC/DC 24 – 240 V 3.5 VA / 1.7 W 1.6 W 70 – 110 % 50 – 60 Hz ± 5 % ≥ AC/DC 10 V; permissible line capacity 0.2 µF 1 mA < 0.25 W A1-A2 yes A1-A2 no Time circuit Time setting / number of time ranges Setting ranges for time delay Recovery time 1/2 Minimum ON time 1/2 Setting tolerance Repeatability (to set value) Influence of temperature (within range) Influence of voltage (within range) analogous/ 1 See table "Time ranges" ≤ 50 / ≤ 50 ms – / – ms ≤±5% ≤ ± 0.01 % + ± 10 ms ≤ ± 0.002 % ≤ ± 0.002 % Output circuit Contact assignment Contact material Rated operating voltage Rated value for limiting continuous current Ith Minimum contact load Application category according to IEC 60947-5-1 Permissible switching frequency Mechanical life Electrical life 20/2 A, AC 250 V, cos ϕ = 0.3 Response time / release time at excitation of A1-A2 1 instantaneous and 1 timed change-over contact AgNi 90/10 AC/DC 24 – 240 V 5A ≥ AC/DC 5 V / ≥ 10 mA AC-15 Ue AC 230 V, Ie 3 A DC-13 Ue DC 24 V, Ie 2 A ≤ 3600 switching cycles/h 6 30 x 10 switching cycles 6 0.12 x 10 switching cycles AC-15 40 ms Other data Creepage distances and clearances Degree of pollution Overvoltage category Rated voltage Degree of protection according to IEC 60529 housing/terminals Noise immunity according to IEC 61000-4 Ambient temperature, operating range Dimension diagram (housing) Circuit diagram of the terminals Wire ranges stranded or solid stranded with ferrules Weight Accessories according to IEC 60664-1 3 outside, 2 inside III AC/DC 275 V IP 40 / IP 20 Test severity 3 -25 – +60 °C K 3-2 KS 250-5 2 1 x 0.2 – 6 or 2 x 0.2 to 2.5 mm 2 1 x 0.4 – 4 or 2 x 0.2 to 1.5 mm 0.1 kg – Overview of devices / Part numbers Type NGZ 12-S Page 68 Rated voltage AC/DC 24-240 V 50-60 Hz NGZ 12 S ON-delay time <0.1 ... 1 0.15 ... 3 0.5 ... 10 1.5 ... 30 5 ... 100 15 ... 300 50 ... 1000 0.5 ... 10 1.5 ... 30 3 ... 60 0.5 ... 10 1.5 ... 30 5 ... 100 s s s s s s s min min min h h h Part No. R2.064.0349.0 R2.064.0399.0 R2.064.0339.0 R2.064.0389.0 R2.064.0309.0 R2.064.0359.0 R2.064.0289.0 R2.064.0329.0 R2.064.0379.0 R2.064.0409.0 R2.064.0319.0 R2.064.0369.0 R2.064.0299.0 Subject to change without further notice NGZ 71 NGZ 71 ON-delay multi-range timer relay • • • • • Multi voltage for AC/DC 24 up to 240 V 1 function: ON-delay (AV) Setting range from 0.1 s to 300 h divided into 16 selectable time ranges 1 change-over contacts 2 LEDs for function display Circuit diagram Time ranges Setting range from 0.1 s to 300 h divided into: <0.1 ... 1 s 5 ... 100 s 1.5 ... 30 min 0.15 ... 3 s 15 ... 300 s 3 ... 60 min 0.5 ... 10 s 50 ... 1000 s 5 ... 100 min 1.5 ... 30 s 0.5 ... 10 min 0.15 ... 3 h 0.5 ... 1.5 ... 5 ... 15 ... 10 30 100 300 h h h h Function Setting the time delay The time range is set with the RANGE selector switch and displayed in the window next to it. The desired delay time is set with a selecting wheel. Function diagrams LEDs show the state of the excitation input and the position of the contacts. You can monitor the countdown on a flashing LED. Notes The device is designed for multi-voltage. Phase L1 or L+ must be connected to terminal A1; neutral conductor N or M must be connected to terminal A2. You can change the delay time during operation. The change is effective immediately. Dimension diagram Subject to change without further notice NGZ 71 Page 69 DZ NGZ 71 Technical data NGZ 71 Product standard (timer relays) Function type of the relay according to IEC 60050 Function display Function diagrams EN 61812-1:1999-08 445-01-02 2 LEDs green FD 250-1 Input circuit Rated voltage A1-A2 Rated consumption AC Rated consumption DC Rated voltage limits Rated frequency fn Release value of the input voltage (power capacity approx. 150 pF/m) Rated current on control connection (A1) Rated consumption on control connection (A1) Parallel loads permissible Internal half-wave rectification AC/DC 24 – 240 V 3.5 VA / 1.7 W 1.6 W 70 – 110 % 50 – 60 Hz ± 5 % ≥ AC/DC 10 V; permissible line capacity 0.2 µF 1 mA < 0.25 W A1-A2 yes A1-A2 no Time circuit Time setting / number of time ranges Setting ranges for time delay Recovery time 1/2 Minimum ON time 1/2 Setting tolerance Repeatability (to set value) Influence of temperature (within range) Influence of voltage (within range) analogous/ 16 See table "Time ranges" ≤ 50 / ≤ 50 ms – / – ms ≤±5% ≤ ± 0.01 % + ± 10 ms ≤ ± 0.002 % ≤ ± 0.002 % Output circuit Contact assignment Contact material Rated operating voltage Rated value for limiting continuous current Ith Minimum contact load Application category according to IEC 60947-5-1 Permissible switching frequency Mechanical life Electrical life 20/2 A, AC 250 V, cos ϕ = 0.3 Response time / release time at excitation of A1-A2 1 change-over contacts AgNi 90/10 AC/DC 24 – 240 V 5A ≥ AC/DC 5 V / ≥ 10 mA AC-15 Ue AC 230 V, Ie 3 A DC-13 Ue DC 24 V, Ie 2 A ≤ 3600 switching cycles/h 6 30 x 10 switching cycles 6 0.12 x 10 switching cycles AC-15 40 ms Other data Creepage distances and clearances Degree of pollution Overvoltage category Rated voltage Degree of protection according to IEC 60529 housing/terminals Noise immunity according to IEC 61000-4 Ambient temperature, operating range Dimension diagram (housing) Circuit diagram of the terminals Wire ranges stranded or solid stranded with ferrules Weight Accessories according to IEC 60664-1 3 outside, 2 inside III AC/DC 275 V IP 40 / IP 20 Test severity 3 -25 – +60 °C K 3-1 KS 250-1 2 1 x 0.2 – 6 or 2 x 0.2 to 2.5 mm 2 1 x 0.4 – 4 or 2 x 0.2 to 1.5 mm 0.1 kg – Overview of devices / Part numbers Type NGZ 71 Page 70 Rated voltage AC/DC 24-240 V 50-60 Hz NGZ 71 ON-delay time See table "Time ranges" Part No. R2.065.0069.0 Subject to change without further notice NGZ 110 Timer and switching relays Zeitrelais Rückfallverzögerung Register: NGZ 110 OFF-delay single-range timer relay without auxiliary supply • • • • • 3 Single supply voltages for AC/DC available 1 Function: OFF-delay (RV) 6 time ranges available from 0,05 to 300 s 1 change-over contacts 1 LED for function display Circuit diagram Time ranges Available time ranges: 0,05 ... 1 s 0,15 ... 3 s 0,5 ... 10 s 1,5 ... 30 s 5 ... 100 s 15 ... 300 s Function Setting the time delay The desired delay time is set with a selecting wheel. It can be set using a screwdriver. Function diagrams The LED indicates the status of the input excitation. Notes The unit is designed for single voltage. Terminal A1 must be connected to phase L1 or L+. Terminal A2 must be connected to the neutral conductor N or M. An adjustment of the ON-delay time during the operational sequence is admissible, the adjustment is effective immediately. Dimension diagram Subject to change without further notice NGZ 110 Page 71 NGZ 110 Technical data Product standard (timer relays) Function type of the relay according to IEC 60050 Function display Function diagrams Input circuit NGZ 110 EN 61812-1:1999-08 445-01-03 1 LED grün FD 250-16 Rated voltage A1-A2 Rated consumption AC Rated consumption at 50 Hz und UA1/A2 (AC) Rated consumption DC Starting current inrushstoß Rated voltage limits Rated frequency fn Release value of the input voltage Parallel loads permissible Internal half-wave rectification AC/DC AC 24 V 110-127 V 0,1 VA 0,8 VA 0,06 W 0,5 W 0,06 W 0,4 A / 40 ms 0,1 A / 40 ms 80 bis 110 % 50 – 60 Hz ± 5 % – A1-A2 yes A1-A2 yes Time circuit Time setting / number of time ranges Setting ranges for time delay Recovery time 1 Minimum ON time 1/2 Setting tolerance Repeatability (to set value) Influence of temperature (within range) Influence of voltage (within range) analogous/ 1 See table "Time ranges" approx. 250 ms approx. 200 / approx. 200 ms (bei 300 s: approx. 500 / approx. 500 ms) ≤±5% ≤ ± 1 % + ± 10 ms ≤ ± 0,04 % ≤ ± 0,05 % Output circuit Contact assignment Contact material Rated operating voltage Rated value for limiting continuous current Ith Application category according to IEC 60947-5-1 AC 230-240 V 1,3 VA 0,9 W 0,05 A / 150 ms Permissible switching frequency Mechanical life Electrical life Response time / release time at excitation of A1-A2 1 change-over contacts AgNi 0,15+HVT AC/DC 230/230 V 5A AC-15 Ue AC 230 V, Ie 2 A DC-13 Ue DC 24 V, Ie 2 A ≤ 3600 switching cycles/h 6 10 x 10 switching cycles 5 1 x 10 switching cycles bei Nennlast 15 ms Other data Creepage distances and clearances Degree of pollution Overvoltage category Rated voltage Degree of protection according to IEC 60529 housing/terminals Noise immunity according to IEC 61000-4 Ambient temperature, operating range Dimension diagram (housing) Circuit diagram of the terminals Wire ranges stranded or solid stranded with ferrules Weight Accessories according to IEC 60664-1 3 outside, 2 inside III AC/DC 275 V IP 40 / IP 20 Test severity 3 -25 – +60 °C K 3-1 KS 250-10 2 1 x 0.2 – 6 or 2 x 0.2 to 2.5 mm 2 1 x 0.4 – 4 or 2 x 0.2 to 1.5 mm 0,11 kg – Overview of devices / Part numbers Typ NGZ 110 Nennspannung AC/DC 24 V 50-60 Hz AC/DC 110-127 V 50-60 Hz AC/DC 230-240 V 50-60 Hz Page 72 Zeitverzögerung 0,05 ... 1 0,15 ... 3 0,5 ... 10 1,5 ... 30 5 ... 100 15 ... 300 0,05 ... 1 0,15 ... 3 0,5 ... 10 1,5 ... 30 5 ... 100 15 ... 300 0,05 ... 1 0,15 ... 3 0,5 ... 10 1,5 ... 30 5 ... 100 15 ... 300 s s s s s s s s s s s s s s s s s s Bestellnummer R2.067.0099.0 R2.067.0189.0 R2.067.0069.0 R2.067.0159.0 R2.067.0039.0 R2.067.0129.0 R2.067.0079.0 R2.067.0169.0 R2.067.0049.0 R2.067.0139.0 R2.067.0019.0 R2.067.0109.0 R2.067.0089.0 R2.067.0179.0 R2.067.0059.0 R2.067.0149.0 R2.067.0029.0 R2.067.0119.0 Subject to change without further notice NGZ 310 Timer and switching relays Zeitrelais Rückfallverzögerung Register: NGZ 310 OFF-delay single-range timer relay with auxiliary supply • • • • • Multi voltage for AC/DC 24 up to 240 V 1 function: OFF-delay (RV) 13 time ranges available from 0.1 s to 100 h 1 change-over contact 2 LEDs for function display Circuit diagram Time ranges Available time ranges: <0.1 ... 1 s 5 ... 100 s 0.15 ... 3 s 15 ... 300 s 0.5 ... 10 s 50 ... 1000 s 1.5 ... 30 s 0.5 ... 10 min 1.5 ... 30 min 3 ... 60 min 0.5 ... 10 h 1.5 ... 30 h 5 ... 100 h Function Setting the time delay The desired delay time is set with a selecting wheel. It can be set using a screwdriver. Function diagrams LEDs show the state of the excitation input and the position of the contacts. You can monitor the countdown on a flashing LED. Notes The device is designed for multi-voltage. Phase L1 or L+ must be connected to terminal A1; neutral conductor N or M must be connected to terminal A2. You can change the delay time during operation. The change is effective immediately. Dimension diagram Subject to change without further notice NGZ 310 Page 73 NGZ 310 Technical data NGZ 310 Product standard (timer relays) Function type of the relay according to IEC 60050 Function display Function diagrams EN 61812-1:1999-08 445-01-04 + 445-03-02 2 LEDs green FD 250-10 Input circuit Rated voltage A1-A2 Rated consumption AC Rated consumption DC Rated voltage limits Rated frequency fn Release value of the input voltage (power capacity approx. 150 pF/m) Rated current on control connection (B1-A2) Rated consumption on control connection (B1-A2) Parallel loads permissible Internal half-wave rectification AC/DC 24 – 240 V 3.5 VA / 1.7 W 1.6 W 70 – 110 % 50 – 60 Hz ± 5 % ≥ AC/DC 10 V; permissible line capacity 0.2 µF 1 mA < 0.25 W A1-A2 yes / B1-A1 yes A1-A2 no / B1-A1 yes Time circuit Time setting / number of time ranges Setting ranges for time delay Recovery time 1/2 Minimum ON time 1/2 Setting tolerance Repeatability (to set value) Influence of temperature (within range) Influence of voltage (within range) analogous/ 1 See table "Time ranges" 0 / 0 ms ≤ 25 / – ms ≤±5% ≤ ± 0.01 % + ± 10 ms ≤ ± 0.002 % ≤ ± 0.002 % Output circuit Contact assignment Contact material Rated operating voltage Rated value for limiting continuous current Ith Minimum contact load Application category according to IEC 60947-5-1 Permissible switching frequency Mechanical life Electrical life 20/2 A, AC 250 V, cos ϕ = 0.3 Response time / release time at excitation of A1-A2 Response time / release time at excitation of B1-A2 1 change-over contacts AgNi 90/10 AC/DC 24 – 240 V 5A ≥ AC/DC 5 V / ≥ 10 mA AC-15 Ue AC 230 V, Ie 3 A DC-13 Ue DC 24 V, Ie 2 A ≤ 3600 switching cycles/h 6 30 x 10 switching cycles 6 0.12 x 10 switching cycles AC-15 40 ms 20 ms Other data Creepage distances and clearances Degree of pollution Overvoltage category Rated voltage Degree of protection according to IEC 60529 housing/terminals Noise immunity according to IEC 61000-4 Ambient temperature, operating range Dimension diagram (housing) Circuit diagram of the terminals Wire ranges stranded or solid stranded with ferrules Weight Accessories according to IEC 60664-1 3 outside, 2 inside III AC/DC 275 V IP 40 / IP 20 Test severity 3 -25 – +60 °C K 3-1 KS 250-8 2 1 x 0.2 – 6 or 2 x 0.2 to 2.5 mm 2 1 x 0.4 – 4 or 2 x 0.2 to 1.5 mm 0.1 kg – Overview of devices / Part numbers Type NGZ 310 Page 74 Rated voltage AC/DC 24-240 V 50-60 Hz NGZ 310 ON-delay time <0.1 ... 1 0.15 ... 3 0.5 ... 10 1.5 ... 30 5 ... 100 15 ... 300 50 ... 1000 0.5 ... 10 1.5 ... 30 3 ... 60 0.5 ... 10 1.5 ... 30 5 ... 100 s s s s s s s min min min h h h Part No. R2.067.0329.0 R2.067.0379.0 R2.067.0319.0 R2.067.0369.0 R2.067.0289.0 R2.067.0339.0 R2.067.0269.0 R2.067.0309.0 R2.067.0359.0 R2.067.0389.0 R2.067.0299.0 R2.067.0349.0 R2.067.0279.0 Subject to change without further notice NGZ 710 NGZ 710 OFF-delay multi-range timer relay with auxiliary supply • • • • • Multi voltage for AC/DC 24 up to 240 V 1 function: OFF-delay (RV) with auxiliary supply Setting range from 0.1 s to 300 h divided into 16 selectable time ranges 1 change-over contact 2 LEDs for function display Circuit diagram Time ranges Setting range from 0.1 s to 300 h divided into: <0.1 ... 1 s 5 ... 100 s 1.5 ... 30 min 0.15 ... 3 s 15 ... 300 s 3 ... 60 min 0.5 ... 10 s 50 ... 1000 s 5 ... 100 min 1.5 ... 30 s 0.5 ... 10 min 0.15 ... 3 h 0.5 ... 1.5 ... 5 ... 15 ... 10 30 100 300 h h h h Function Function diagrams Setting the time delay The time range is set with the RANGE selector switch and displayed in the window next to it. The desired delay time is set with a selecting wheel. LEDs show the state of the excitation input and the position of the contacts. You can monitor the countdown on a flashing LED. Notes The device is designed for multi-voltage. Phase L1 or L+ must be connected to terminal A1; neutral conductor N or M must be connected to terminal A2. You can change the delay time during operation. The change is effective immediately. Dimension diagram Subject to change without further notice NGZ 710 Page 75 NGZ 710 Technical data NGZ 710 Product standard (timer relays) Function type of the relay according to IEC 60050 Function display Function diagrams EN 61812-1:1999-08 445-01-04 + 445-03-02 2 LEDs green FD 250-10 Input circuit Rated voltage A1-A2 Rated consumption AC Rated consumption DC Rated voltage limits Rated frequency fn Release value of the input voltage (power capacity approx. 150 pF/m) Rated current on control connection (B1-A2) Rated consumption on control connection (B1-A2) Parallel loads permissible Internal half-wave rectification AC/DC 24 – 240 V 3.5 VA / 1.7 W 1.6 W 70 – 110 % 50 – 60 Hz ± 5 % ≥ AC/DC 10 V; permissible line capacity 0.2 µF 1 mA < 0.25 W A1-A2 yes / B1-A2 yes A1-A2 no / B1-A2 yes Time circuit Time setting / number of time ranges Setting ranges for time delay Recovery time 1/2/3 Minimum ON time 1/2 Setting tolerance Repeatability (to set value) Influence of temperature (within range) Influence of voltage (within range) analogous/ 16 See table "Time ranges" 0 / 0 / – ms ≤ 25 / – ms ≤±5% ≤ ± 0.01 % + ± 10 ms ≤ ± 0.002 % ≤ ± 0.002 % Output circuit Contact assignment Contact material Rated operating voltage Rated value for limiting continuous current Ith Minimum contact load Application category according to IEC 60947-5-1 Permissible switching frequency Mechanical life Electrical life 20/2 A, AC 250 V, cos ϕ = 0.3 Response time / release time at excitation of A1-A2 Response time / release time at excitation of B1-A2 1 change-over contacts AgNi 90/10 AC/DC 24 – 240 V 5A ≥ AC/DC 5 V / ≥ 10 mA AC-15 Ue AC 230 V, Ie 3 A DC-13 Ue DC 24 V, Ie 2 A ≤ 3600 switching cycles/h 6 30 x 10 switching cycles 6 0.12 x 10 switching cycles AC-15 40 ms 20 ms Other data Creepage distances and clearances Degree of pollution Overvoltage category Rated voltage Degree of protection according to IEC 60529 housing/terminals Noise immunity according to IEC 61000-4 Ambient temperature, operating range Dimension diagram (housing) Circuit diagram of the terminals Wire ranges stranded or solid stranded with ferrules Weight Accessories according to IEC 60664-1 3 outside, 2 inside III AC/DC 275 V IP 40 / IP 20 Test severity 3 -25 – +60 °C K 3-1 KS 250-8 2 1 x 0.2 – 6 or 2 x 0.2 to 2.5 mm 2 1 x 0.4 – 4 or 2 x 0.2 to 1.5 mm 0.1 kg – Overview of devices / Part numbers Type NGZ 710 Page 76 Rated voltage AC/DC 24-240 V 50-60 Hz NGZ 710 ON-delay time See table "Time ranges" Part No. R2.065.0079.0 Subject to change without further notice NGZ 720 Timer and switching relays Zeitrelais Rückfallverzögerung Register: NGZ 720 OFF-delay multi-range timer relay with auxiliary supply • • • • • Multi voltage for AC/DC 24 up to 240 V 1 function: OFF-delay (RV) with auxiliary supply Setting range from 0.1 s to 300 h divided into 16 selectable time ranges 2 change-over contact 2 LEDs for function display Circuit diagram Time ranges Setting range from 0.1 s to 300 h divided into: <0.1 ... 1 s 5 ... 100 s 1.5 ... 30 min 0.15 ... 3 s 15 ... 300 s 3 ... 60 min 0.5 ... 10 s 50 ... 1000 s 5 ... 100 min 1.5 ... 30 s 0.5 ... 10 min 0.15 ... 3 h 0.5 ... 1.5 ... 5 ... 15 ... 10 30 100 300 h h h h Function Setting the time delay The time range is set with the RANGE selector switch and displayed in the window next to it. The desired delay time is set with a selecting wheel. Function diagrams LEDs show the state of the excitation input and the position of the contacts. You can monitor the countdown on a flashing LED. Notes The device is designed for multi-voltage. Phase L1 or L+ must be connected to terminal A1; neutral conductor N or M must be connected to terminal A2. You can change the delay time during operation. The change is effective immediately. Dimension diagram Subject to change without further notice NGZ 720 Page 77 NGZ 720 Technical data NGZ 720 Product standard (timer relays) Function type of the relay according to IEC 60050 Function display Function diagrams EN 61812-1:1999-08 445-01-04 + 445-03-02 2 LEDs green FD 250-11 Input circuit Rated voltage A1-A2 Rated consumption AC Rated consumption DC Rated voltage limits Rated frequency fn Release value of the input voltage (power capacity approx. 150 pF/m) Rated current on control connection (B1-A2) Rated consumption on control connection (B1-A2) Parallel loads permissible Internal half-wave rectification AC/DC 24 – 240 V 3.5 VA / 1.7 W 1.6 W 70 – 110 % 50 – 60 Hz ± 5 % ≥ AC/DC 10 V; permissible line capacity 0.2 µF 1 mA < 0.25 W A1-A2 yes / B1-A2 yes A1-A2 no / B1-A2 yes Time circuit Time setting / number of time ranges Setting ranges for time delay Recovery time 1/2/3 Minimum ON time 1/2 Setting tolerance Repeatability (to set value) Influence of temperature (within range) Influence of voltage (within range) analogous/ 16 See table "Time ranges" 0 / 0 / – ms ≤ 25 / – ms ≤±5% ≤ ± 0.01 % + ± 10 ms ≤ ± 0.002 % ≤ ± 0.002 % Output circuit Contact assignment Contact material Rated operating voltage Rated value for limiting continuous current Ith Minimum contact load Application category according to IEC 60947-5-1 Permissible switching frequency Mechanical life Electrical life 20/2 A, AC 250 V, cos ϕ = 0.3 Response time / release time at excitation of A1-A2 Response time / release time at excitation of B1-A2 2 change-over contacts AgNi 90/10 AC/DC 24 – 240 V 5A ≥ AC/DC 5 V / ≥ 10 mA AC-15 Ue AC 230 V, Ie 3 A DC-13 Ue DC 24 V, Ie 2 A ≤ 3600 switching cycles/h 6 30 x 10 switching cycles 6 0.12 x 10 switching cycles AC-15 40 ms 20 ms Other data Creepage distances and clearances Degree of pollution Overvoltage category Rated voltage Degree of protection according to IEC 60529 housing/terminals Noise immunity according to IEC 61000-4 Ambient temperature, operating range Dimension diagram (housing) Circuit diagram of the terminals Wire ranges stranded or solid stranded with ferrules Weight Accessories according to IEC 60664-1 3 outside, 2 inside III AC/DC 275 V IP 40 / IP 20 Test severity 3 -25 – +60 °C K 3-3 KS 250-9 2 1 x 0.2 – 6 or 2 x 0.2 to 2.5 mm 2 1 x 0.4 – 4 or 2 x 0.2 to 1.5 mm 0.13 kg – Overview of devices / Part numbers Type NGZ 720 Page 78 Rated voltage AC/DC 24-240 V 50-60 Hz NGZ 720 ON-delay time See table "Time ranges" Part No. R2.065.0099.0 Subject to change without further notice NGZP 32 NGZP 32 ON-delay single-range timer relay with remote potentiometer connection • • • • • • Multi voltage for AC/DC 24 to 240 V 1 function: ON-delay (AV) 13 time ranges available from 0.1 s to 100 h Remote potentiometer connection 2 change-over contact 2 LEDs for function display Circuit diagram Time ranges Available time ranges: <0.1 ... 1 s 5 ... 100 s 0.15 ... 3 s 15 ... 300 s 0.5 ... 10 s 50 ... 1000 s 1.5 ... 30 s 0.5 ... 10 min 1.5 ... 30 min 3 ... 60 min 0.5 ... 10 h 1.5 ... 30 h 5 ... 100 h Function Setting the time delay The desired delay time is set with a selecting wheel. It can be set using a screwdriver. Function diagrams Connecting a remote potentiometer allows you to set parameters at greater distances. When a remote potentiometer is used, the time selecting wheel is to be set to the right-hand stop above the largest value. Operation without remote potentiometer does not require a jumper on the device. LEDs show the state of the excitation input and the position of the contacts. You can monitor the countdown on a flashing LED. Notes The device is designed for multi-voltage. Phase L1 or L+ must be connected to terminal A1; neutral conductor N or M must be connected to terminal A2. You can change the delay time during operation. The change is effective immediately. Dimension diagram Accessories Accessories: Remote potentiometer FP 10 k Subject to change without further notice NGZP 32 Page 79 NGZP 32 Technical data NGZP 32 Product standard (timer relays) Function type of the relay according to IEC 60050 Function display Function diagrams EN 61812-1:1999-08 445-01-02 2 LEDs green FD 250-2 Input circuit Rated voltage A1-A2 Rated consumption AC Rated consumption DC Rated voltage limits Rated frequency fn Release value of the input voltage (power capacity approx. 150 pF/m) Rated current on control connection (A1) Rated consumption on control connection (A1) Parallel loads permissible Internal half-wave rectification AC/DC 24 – 240 V 3.5 VA / 1.7 W 1.6 W 70 – 110 % 50 – 60 Hz ± 5 % ≥ AC/DC 10 V; permissible line capacity 0.2 µF 1 mA < 0.25 W A1-A2 yes A1-A2 no Time circuit Time setting / number of time ranges Setting ranges for time delay Recovery time 1/2 Minimum ON time 1/2 Setting tolerance Repeatability (to set value) Influence of temperature (within range) Influence of voltage (within range) analog (intern + extern) / 1 See table "Time ranges" ≤ 50 / ≤ 50 ms –/– ≤±5% ≤ ± 0.01 % + ± 10 ms ≤ ± 0.002 % ≤ ± 0.002 % Output circuit Contact assignment Contact material Rated operating voltage Rated value for limiting continuous current Ith Minimum contact load Application category according to IEC 60947-5-1 Permissible switching frequency Mechanical life Electrical life 20/2 A, AC 250 V, cos ϕ = 0.3 Response time / release time at excitation of A1-A2 2 change-over contacts AgNi 90/10 AC/DC 24 – 240 V 5A ≥ AC/DC 5 V / ≥ 10 mA AC-15 Ue AC 230 V, Ie 3 A DC-13 Ue DC 24 V, Ie 2 A ≤ 3600 switching cycles/h 6 30 x 10 switching cycles 6 0.12 x 10 switching cycles AC-15 40 ms Other data Creepage distances and clearances Degree of pollution Overvoltage category Rated voltage Degree of protection according to IEC 60529 housing/terminals Noise immunity according to IEC 61000-4 Ambient temperature, operating range Dimension diagram (housing) Circuit diagram of the terminals Wire ranges stranded or solid stranded with ferrules Weight Accessories according to IEC 60664-1 3 outside, 2 inside III AC/DC 275 V IP 40 / IP 20 Test severity 3 -25 – +60 °C K 3-3 KS 250-4 2 1 x 0.2 – 6 or 2 x 0.2 to 2.5 mm 2 1 x 0.4 – 4 or 2 x 0.2 to 1.5 mm 0.14 kg Remote potentiometer FP 10 k Overview of devices / Part numbers Type NGZP 32 Page 80 Rated voltage AC/DC 24-240 V 50-60 Hz NGZP 32 ON-delay time <0.1 ... 1 0.15 ... 3 0.5 ... 10 1.5 ... 30 5 ... 100 15 ... 300 50 ... 1000 0.5 ... 10 1.5 ... 30 3 ... 60 0.5 ... 10 1.5 ... 30 5 ... 100 s s s s s s s min min min h h h Part No. R2.064.0619.0 R2.064.0669.0 R2.064.0609.0 R2.064.0659.0 R2.064.0579.0 R2.064.0629.0 R2.064.0559.0 R2.064.0599.0 R2.064.0649.0 R2.064.0679.0 R2.064.0589.0 R2.064.0639.0 R2.064.0569.0 Subject to change without further notice SSP 56 SSP 56 SSP 33 SSP 72 SSP 34 Flip-flop relay SSP 56, SSP 72 SSP 33, SSP 34 Wiring diagram • Devices for Mono voltage • Function: flip-flop relay • contact assembly: SSP 56 = 3 NO and 3 NC contacts SSP 72 = 2 changers SSP 33 = 3 changers SSP 34 = 4 changers Function The flip-flop relay consists of two separate magnet systems which mutually mechanically latch shut. Upon impulse or constant excitation of the magnet system equipped with contacts, the contacts toggle to the operating position. At the same time, the catches on the relay anchors latch shut, so that even in the event of a voltage failure and/or a voltage interruption, the operating position of the contacts is maintained. Upon excitation of the non-equipped magnet system, the latch is released and the contacts return to the default position. On the device types SSP 56 and SSP 72, a lever protruding from the front plate prompts a manual shift in the magnet system and indicates the position of the magnet and/or the contact. On the device types SSP 33 and SSP 34, two pushbuttons are available for this purpose. The relay contacts have no preferred position. If both inductors are excited simultaneously, the operating position of the contacts is maintained. Function diagram Dimensional drawings Subject to change without further notice SSP 56 Page 81 SSP 56 Technical Data SSP 56 Function type according to DIN VDE 0435 Section 110:04.89 Function indicator Function diagram Supply circuit Nominal voltage UN Rated output Re 1 at 50 Hz and UN (AC) Power-on SSP 72 Electro-mechanical flip-flop relay for Mono voltage Item 2.4: bi-stable relay Positioning lever Positioning lever Pushbuttons FD 0022a Rated output Re 2 at 50 Hz and UN (AC) Power-on Rated output Re 2 at 50 Hz and UN (AC) Hold Nominal frequency Operating voltage range see Device overview approx. 13 VA / approx. 13 VA / approx. 4.5 W approx. 4.5 W approx. 4 VA / approx. 4 VA / approx. 1.5 W approx. 1.5 W approx. 10.5 VA / approx. 3.5 W approx. 3 VA / approx. 1 W see Device overview 0.8 to 1.1 x UN Timing circuit Time setting/Numbers of time domains Available time domains Standby reactivation interval Minimum power-on time Fallback value Parallel consumer loads permissible Internal one-way rectification direction –/– – – – ≥ 15 % UN yes no Rated output Re 1 at 50 Hz and UN (AC) Hold Output circuit contact assembly Contact material Switching nominal voltage Un max. steady current In Usage category according to EN 60947-5-1:1991 Permissible frequency of operation Mechanical service life Response time Fallback time General Data Air and crawl sections between the electric circuits Rated surge voltage Over-voltage category Degree of contamination Rated voltage Testing voltage Ueff 50 Hz according to DIN VDE 0110-1, Table A.1 Safety class for casing/terminals according to DIN VDE 0470 Section 1:11.92 Interference emission Interference resistance Ambient temperature, work area Dimensional drawing Wiring diagram Weight Accessories SSP 33 3 NO contacts 2 changers and 3 NC contacts Ag Cu AC/DC 400 V 5A AC-15: Ue 230 V AC, Ie 2 A ≤ 3600 switching cycles/h 6 10 x 10 switching cycles ≤ 20 ms ≤ 25 ms SSP 34 Pushbuttons approx. 18 VA / approx. 6.5 W approx. 5.2 VA / approx. 1.8 W approx. 18 VA / approx. 6.5 W approx. 5.2 VA / approx. 1.8 W 3 changers 4 changers DC-13: Ue 24 V DC, Ie 2 A according to DIN VDE 0110-1:04.97 5 kV III 3 exterior, 2 interior 400 V AC 2.7 kV IP 30/IP 20 EN 50081-1:03.93. -2:03.94 EN 50082-2:1995 –10 to +55 °C S 3-5 S 3-5 KS 5161/2 KS 5172/2 0.5 kg 0.5 kg – S 2-1 KS 5143/2 0.6 kg S 2-1 KS 5137/2 0.6 kg Device overview / Order numbers Type SSP 56 Rated voltage AC 24 V 50 Hz AC 42 V 50 Hz AC 48 V 50 Hz AC 110 V 50 Hz AC 110 V 60 Hz AC 120-131 V 60 Hz AC 230 V 50 Hz AC 24 V 50 Hz AC 110-115 V 60 Hz AC 230 V 50 Hz AC 24 V 50 Hz AC 230 V 50 Hz AC 110 V 50 Hz AC 230 V 50 Hz SSP 72 SSP 33 SSP 34 Page 82 SSP 56 Order number R2.153.0149.0 R2.153.0089.0 R2.153.0049.0 R2.153.0059.0 R2.153.0079.0 R2.153.0139.0 R2.153.0109.0 R2.153.0099.0 R2.153.0109.0 R2.153.0029.0 R2.152.0099.0 R2.152.0179.0 R2.152.0119.0 R2.152.0079.0 Subject to change without further notice SSY 12 SSY 12 Interval ON and/or OFF fixed timer relay • • • • Single voltage 1 function: Interval ON and/or OFF (EAW) Fixed interval time 0.5 s 1 interval change-over contact and 1 interval NO Circuit diagram Time ranges Fixed interval time 0.5 s Function The function (interval ON, interval OFF, interval ON/OFF) is selectable with the jumpers on the terminals (see connection diagram). Jumper Z1/Z2 = Jumper Z2/Z3 = No jumper = interval ON interval OFF interval ON and OFF Function diagrams Dimension diagram Subject to change without further notice SSY 12 Page 83 SSY 12 Technical data SSY 12 Function type according to IEC 60050 (445) Electronic interval timer relay for single voltage; function selectable – Interval ON relay – Interval OFF relay – FD 0015 Function display Function diagrams Power supply circuit Rated voltage UN Rated consumption at 50 Hz and UN (AC) Rated consumption DC Starting current inrush stroke Rated frequency Operating voltage range AC/DC Time circuit Time setting / number of time ranges Available setting range Recovery time 1 Minimum ON time(after application of the rated voltage) Release value Parallel loads permissible Internal half-wave rectification Mean value of the error Dispersion Influence of the energizing quantity, supply voltage Influence of the ambient temperature Output circuit Contact assignment Contact material Rated operating voltage Un Max. continuous current In Application category according to EN 60947-5-1:1991 Permissible switching frequency Mechanical life Response time Release time General information Creepage distances and clearances between the circuits Rated impulse voltage Overvoltage category Degree of pollution Rated voltage Test voltage Ueff 50 Hz according to DIN VDE 0110-1, table A.1 Protection degree housing/terminal according to DIN VDE 0470 sec. 1:11.92 Noise immunity according to IEC 61000-4 Ambient temperature, operating range Dimension diagram Circuit diagram Weight Accessories Approvals 24 V 0.6 VA / 0.5 W 0.3 W 0.3 A / 6 ms 50 to 60 Hz 0.8 to 1.1 x UN 110 – 127 V 2.0 VA / 1.7 W 1.1 W 0.1 A / 20 ms 230 V 2.0 VA / 1.8 W 1.3 W 0.1 A / 100 ms fixed / 1 See table "Time ranges" approx. 250 ms at continuous operation, approx. 3 s after longer shutdown approx. 3 s – Yes no ≤ ± 20 % ≤ ± 1.5 % + ± 10 ms ≤ 1.2 % / % ∆ UN ≤ 0.5 % / K 1 passing change-over contact and 1 passing NO Ag alloy, gold-plated 230/230 V AC/DC 5A AC-15: Ue 230 V AC, Ie 2 A DC-13: Ue 24 V DC, Ie 2 A ≤ 6000 switching cycles/h 6 30 x 10 switching cycles approx. 20 ms – according to DIN VDE 0110-1:04.97 4 kV III 3 outside, 2 inside 250 V AC 2.21 kV IP 30 / IP 20 Test severity 3 –20 to +60 °C S 3-2 KS 0115-1 0.17 kg – – Overview of devices / Part numbers Type SSY 12 Page 84 Rated voltage AC 110-127 V 50-60 Hz AC/DC 24 V 50-60 Hz AC/DC 230 V 50-60 Hz SSY 12 ON-delay time See table "Time ranges" Part No. R2.133.0019.3 R2.133.0029.3 R2.133.0039.3 Subject to change without further notice UZD 51 UZD 51 Digital multi-function multi-range relay • • • • • • Multi-voltage for AC 100 to 240 V, Mono-voltage for AC/DC 24 V 8 functions 2 color high-contrast LCD displays Setting range digital 0.001 s to 999.9 h split into 8 time ranges Zero-voltage secure 1 timed change-over contact Circuit diagram Function The selection of the individual function and the time range is by a dual in-line switch that is located on the right-hand side wall of the equipment. The time selection is carried out on the front. The set target value is displayed digitally with a four-digit yellow LCD display and the individual actual value is displayed digitally with a four-digit red LCD display. The set value settings are retained even if the power supply drops out and is reinstated. Setting the function, the time range and the time preselection 1. Setting the function and the time range The new settings become active after switching off and on again of the power supply. Dual in-line switch Time ranges Setting range 0.001 s to 999.9 h split into: 0.001 s … 999.9 s 10 0.01 s … 99.99 s 0.1 0.1 s … 999.9 s 1 1s … 9999 s 0.1 s min min h … … … … 99 min 59 s 999.9 min 99 h 59 min 999.9 h Notes • Set the function and time range before installing the unit. • We recommend using the LOCK button to prevent inadvertent resetting of the set values. • Adjusting the set value during the time sequence is not permitted. • Gold-plated contacts should be used to ensure perfect switching. • Switching by transistor is possible; see technical data. Accessories Plug mount Plug mount AT8-DF8S AT8-RR for DIN rail for operating panel mount 1 2 3 4 5 6 7 8 Functions See Table 1 Minimum on time Setting time sequence 20 ms additive Time ranges See Table 2 1 ms subtractive Table 1: Setting the function Switch number 1 2 3 ON ON ON OFF OFF OFF ON OFF OFF OFF ON OFF ON ON OFF OFF ON OFF OFF OFF ON ON ON ON Functions Mode A: response delay (AV) A2: response delay (AV) B: response delay (AV) by excitation parameter C: fallback delay (RV) with excitation parameter D: switch-on wiper (EW) with excitation parameter E: response delay (AV) (impulse switching) F: clock generator starting with pause (TP) G: response delay (AV) (time addition or subtraction) Table 2: 2: Setting the time range Switch number 6 7 8 ON ON ON OFF OFF OFF ON OFF OFF OFF ON OFF ON ON OFF OFF OFF ON ON OFF ON OFF ON ON Subject to change without further notice Dual in-line switch OFF ON Range Time range 0.00 S 0.01 s 0.1 1 10 s 0.1 min 1 min 0.1 h to to to to to to to to UZD 51 9.999 s 99.99 s 999.9 s 9999 s 99 min 59 s 999.9 min 99 h 59 min 999.9 h Page 85 UZD 51 Function Function diagrams 2. Setting the time preselection Time preselection is carried out using the four buttons on the front. Front view 1 - LCD display for the specific actual value 2 - LCD display for the set value 3 - LED display that flashes when time running 4 - Display, output excited 5 - Display, reset input switched 6 - Display, blocked input 7 - Display of set time range 8 - UP button, additive change of set value 9 - DOWN button, subtractive change of set value 10 - RESET button, deletes the actual value and resets the output 11 - LOCK button, blocks the RESET, the UP and the DOWN buttons Dual in-line switch Dimension diagram Subject to change without further notice UID 51 Page 86 UZD 51 Technical data UZD 51 Function type according to IEC 60050 (445) Multi-function relay with 8 functions for multi or mono voltage - response delayed time relay - fallback delayed time relay with power supply - switch-on wiper - clock generator 4 digit red LCD display for actual value, character height 7 mm, 4 digit yellow LCD display for set value, character height 5.5 mm, Text fade-in FD 0239-5/1 to 8 Function display Function diagrams Power supply circuit Rated voltage UN AC/DC AC AC DC Rated consumption at 50 Hz and UN Rated output Rated frequency Operating voltage range Residual ripple of the rated voltage UN Time circuit Electrical isolation from power supply circuit Time setting / number of time ranges Available setting range Setting the time sequence (adjustable) Clock start Repeatability Setting acuity Influence of excitation or power supply Minimum ON time(adjustable) Reset / excitation parameter Recovery time Transistor starting (open collector)of connections 3 or 4 Input voltage Maximum input resistance (switched condition) Minimum input resistance (open condition) Maximum residual voltage (switched condition) Output circuit Contact assignment Contact material Switching voltage Un Max. continuous current In Application category according to EN 60947-5-1:1991 Permissible switching frequency Mechanical life Electrical life General information Creepage distances and clearances between the circuits Rated impulse voltage Overvoltage category Degree of pollution Rated voltage Test voltage Ueff 50 Hz according to DIN VDE 0110-1, table A.1 Protection degree housing/terminal according to DIN VDE 0470 sec. 1:11.92 Noise immunity according to IEC 61000-4 Ambient temperature, operating range Dimension diagram Circuit diagram Weight Accessories 24 V 100 to 240 V 10 VA 3W 50 to 60 Hz 0.85 to 1.1 x UN ≤ 20 % nein 4-digit digital / 8 See table "Time ranges" additive, subtractive Pause ± 0.005 % + 50 ms ± 0.005 % + 50 ms ± 0.005 % + 50 ms 20 ms / 1 ms (only with transistor starting) ≤ 100 ms VCEO 20 V min., IC 20 mA, ICBO 6 µA max 12 to 40 V DC ≤ 1 kΩ ≥ 100 kΩ ≤2V 1 timed change-over contact Ag alloy, gold-plated 230/30 V AC/DC 5A AC-15: Ue 250 V AC, Ie 0.75 A DC-13: Ue 30 V DC, Ie 2 A ≤ 3600 switching cycles/h 20 x 106 switching cycles 1 x 106 switching cycles according to DIN VDE 0110-1:04.97 4 kV III 3 outside, 2 inside 300 V AC 2.21 kV IP 66 ((only with rubber seal) / IP 20 Test severity 3 –10 to +55 °C U 3-1 KS 0362/1 0.11 Kg Plug mounts AT8-DF8S, AT8-RR Overview of devices / Part numbers Type UZD 51 ON-delay time See table "Time ranges" Subject to change without further notice Rated voltage AC/DC 24 V 50-60 Hz AC 110-240 V 50-60 Hz Part No. R2.063.0019.0 R2.063.0029.0 UZD 51 Page 87 Pre-set pulse counter Electronic timer UID 51 UID 51 Digital multi function pre-set pulse counter • Device for multi voltage AC 100 to 240 V for single voltage AC/DC 24 V • 5 input and 7 output modes; any combination possible • 2-color high-contrast LCD displays Protected against power failure • 1 normally open contact Circuit diagram Pulse range Available pulse ranges: –999 bis +9999 Function The functions are set by means of a dual in-line switch located on the right lateral side of the device. The setpoint value is set through four switches and is digitally indicated on a 4-digit yellow LCD display and the actual value is digitally indicated on a 4-digit red LCD display. The setpoint settings are protected against power failure and recovery. 1. Setting of the operating modes (input and output mode) Dual-in-line-Schalter Function Notes • Set the function prior to installing the device. • Press the LOCK key to avoid unintentional modifications to the set values. • Modifications to the setpoint value during the counting operation are permissible. • Use gold-plated contacts to achieve proper control. • Semiconductor input possible; see “Technical data” Accessories Pin holder Pin holder AT8-DF8S AT8-RR for DIN-rail for panel mounting 1 2 3 4 5 6 7 8 Dual-in-line-switch OFF ON Output mode See table 1 Min. reset input signal width Max. count rate 20 ms 30 kHz Input mode s See table 2 1 ms 5 kHz Table 1: Output mode DIP switch no. Output mode 1 2 3 ON ON ON ON pulse, SHOT-A OFF OFF OFF ON pulse, SHOT-B ON OFF OFF ON pulse, SHOT-C OFF ON OFF ON pulse, SHOT-D ON ON OFF Holding function, HOLD-A OFF OFF ON Holding function, HOLD-B ON OFF ON Holding function, HOLD-C OFF ON ON – (DIP Err appears on the display) T Table 2: Input mode DIP switch no. 6 7 8 ON ON ON OFF OFF OFF ON OFF OFF OFF ON OFF ON ON OFF OFF OFF ON ON OFF ON OFF ON ON Subject to change without further notice Input mode Additive input Subtractive input Direction input Independent inputs Phase input – (DIP Err appears on the display) – (DIP Err appears on the display) – (DIP Err appears on the display) UID 51 Page 88 Pre-set pulse counter Electronic timer UID 51 Function 2. Setting of the setpoint The setpoint is set using the four switches on the front. Function diagrams Input modes Front view 1 – LCD display for the current actual value 2 – LCD display for the selected setpoint value 3 – Indicator for energized output 4 – Indicator for controlled reset input 5 – Lock indicator 6 – UP keys, additive modification to the selected setpoint value 7 – DOWN keys, subtractive modification to the selected setpoint value 8 – RESET switch, clears the actual value and resets the output 9 – LOCK switch, locks the RESET key, the UP and DOWN keys Dual-in-line-switch Dimension diagram Subject to change without further notice UID 51 Page 89 Pre-set pulse counter Electronic timer UID 51 Function diagrams Output modes Subject to change without further notice Function diagrams Output modes UID 51 Page 90 Pre-set pulse counter Electronic timer UID 51 Technical data Function type UID 51 Multi-function pulse counter with 5 input and 7 output functions for multivoltage or single voltage 4-digit red LCD display for actual value, digit size 7 mm, 4-digit yellow LCD display for setpoint value, digit size 5.5 mm, Text indications See column "Function diagrams" Function display Function diagrams Power supply circuit Rated voltage UN AC/DC AC Rated consumption at 50 Hz und UN AC Bemessungsleistung DC Rated frequency Operating voltage range Residual ripple of the rated voltage UN Time circuit Electrical isolation from power supply circuit Setpoint setting / number of setpoint ranges Available setting range Setting of the counting modes Counting rate Min. counting pulse Reset input 24 V 100 – 240 V 10 VA / 3 W 3W 50 – 60 Hz 0,85 – 1,1 x UN ≤ 20 % Locking input Input signal Output circuit Contact assignment Contact material Switching voltage Un Max. continuous current In Application category according to EN 60947-5-1:1991 Permissible switching frequency Mechanical life General information Creepage distances and clearances between the circuits Rated impulse voltage Overvoltage category Degree of pollution Rated voltage Test voltage Ueff 50 Hz according to DIN VDE 0110-1, table A.1 Protection degree housing/terminal according to DIN VDE 0470 sec. 1:11.92 Ambient temperature, operating range Dimension diagram Circuit diagram Weight Accessories Approvals no 4-digit digital See table "Pulse range" additive, subtractive 30 Hz / 5 Hz (selectable with DIP switch) 16,7 ms at 30 Hz / 0,1 ms at 5 kHz, ON time : OFF time = 1 : 1 Signal reset / pressing a key, Min. input time 1 ms / 20 ms (selectable with DIP switch) Min. input signal width: 20 ms Contact or open collector input / input impedance: max. 1 kΩ, residual input voltage: max. 2 V, Open impedance: min. 100 kΩ, max. voltage load: DC 40 V 1 normally open contacts Ag-Legierung, hauchvergoldet 230/30 V AC/DC 5A AC-15: Ue 250 V AC, Ie 0,75 A DC-13: Ue 30 V DC, Ie 2 A ≤ 3600 switching cycles/h 20 x 106 switching cycles according to DIN VDE 0110-1:04.97 4 kV III 3 outside, 2 inside 250 V AC 2,21 kV IP 66 (only with rubber gasket) / IP 20 -10 – +55 °C U 3-2 – 0,11 Kg Pin holders AT8-DF8S, AT8-RR – Overview of devices / Part numbers Type UID 51 Rated voltage AC 24 V 50-60 Hz AC 110-240 V 50-60 Hz Subject to change without further notice Impulsbereich –999 bis +9999 Part No. R2.213.0069.0 R2.213.0079.0 UID 51 Page 91