* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download Hall Current Sensor TK 350-CCS
Immunity-aware programming wikipedia , lookup
Utility frequency wikipedia , lookup
Pulse-width modulation wikipedia , lookup
Electric power system wikipedia , lookup
Power inverter wikipedia , lookup
Brushed DC electric motor wikipedia , lookup
Electrification wikipedia , lookup
Electrical substation wikipedia , lookup
Thermal runaway wikipedia , lookup
Ground (electricity) wikipedia , lookup
Electrical ballast wikipedia , lookup
Mercury-arc valve wikipedia , lookup
Power engineering wikipedia , lookup
Stepper motor wikipedia , lookup
Resonant inductive coupling wikipedia , lookup
Amtrak's 25 Hz traction power system wikipedia , lookup
Current source wikipedia , lookup
History of electric power transmission wikipedia , lookup
Three-phase electric power wikipedia , lookup
Power MOSFET wikipedia , lookup
Stray voltage wikipedia , lookup
Surge protector wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Earthing system wikipedia , lookup
Buck converter wikipedia , lookup
Power electronics wikipedia , lookup
Voltage optimisation wikipedia , lookup
Opto-isolator wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Thousand Hundred Industrial Co.,Ltd. Hall Current Sensor TK 350-CCS For the electronic measurement of currents:DC,AC,pulsed,mixed, with a galvanic isolation between the primary(high power) circuit and the secondary(electronic) circuit. IPN= 7-8-11-13-35 A Pb RoHS COMPLIANT ● Operating performances ( AT =25 ℃ ) Primary nominal r.m.s. current IPN Primary current measuring range IP Secondary nominal r.m.s. current ISN Measuring resistance RM Conversion ratio Supply voltage Current consumption Linearity Accuracy Offset current Thermal drift of Io KN VCC IC εL Response time di/dt accurately followed Hysteresis offset current Isolation voltage Frequency bandwidth X IO IOT tr di/dt IOH Vd with ± 15V 35 A A 0 .. ± 70 A 35 A mA RM min RM max @ ±35Amax 60 @ ±70Amax 60 1-2-3-4-5:1000 ±12~15 ( ±5% ) 10(@±15V)+IS 320 85 ≦±0.2 @0~±IPN ±1 @IPN,VC=±15V,TA=25 ℃, <±0.2 @IP=0,TA=25 ℃ ≦±0.6mA (type ±0.2) @-40~+85℃ <1 >50 ≦±0.3 @±3IPN→0 f 2.5 @50(60)HZ/1min 0~100 TO TS -25~+85℃ -40~+85℃ m 24 Ω Ω V mA % % mA µs A/µs mA KV KHz ● General data Operating temperature Storage temperature Mass g ● Applications ◆AC variable speed drives and servo motor drives ◆Battery supplied applications ◆Uninterruptible Power Supplies(UPS) ◆Static converters for DC motor drives ◆Switched Mode Power Supplies(SMPS) ◆Power supplies for welding applications ● Advantages ◆Excellent ◆Very ◆Low accuracy temperature drift ◆Wide frequency bandwidth ◆Very low insertion losses ◆Optimized T.H good linearity response time ◆High immunity to external interference ◆Current overload capability www.thic.net Thousand Hundred Industrial Co.,Ltd. ● Dimensions (unit: mm) 10.16-2.54*4 15 - 5.34 8.89 11.43 1 + M 15.24 26 5 TK 350-CCS 18.8 23.8 29 10- 0.9 Top view Left view Bottom view 35A/35mA M + - 1 3- 1 Secondary terminals Terminal + : supply voltage + 15 V Terminal M: measure Terminal - : supply voltage - 15 V Connection IN OUT 1~5 + 6~10 - M Mechanical characteristics ·General tolerance ± 0.2 mm ·Fastening & connection of primary 10 pins φ0.9mm ·Fastening & connection of secondary 3 pins φ 1 mm ·Recommended PCB hole 1.2 mm ◆Temperature T.H Is Rm + 0V - Remarks ·Is is positive when Ip flows from terminals 1, 2, 3, 4, 5 to terminals 10, 9, 8, 7, 6 ·This is a standard model. For different versions (supply voltages, turns ratios, unidirectional measurements...), please contact us. of the primary conductor should not exceed 100 ℃. www.thic.net