Download Hall Current Sensor TK 350-CCS

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Immunity-aware programming wikipedia , lookup

Utility frequency wikipedia , lookup

Transistor wikipedia , lookup

Pulse-width modulation wikipedia , lookup

Electric power system wikipedia , lookup

Power inverter wikipedia , lookup

Brushed DC electric motor wikipedia , lookup

Electrification wikipedia , lookup

Electrical substation wikipedia , lookup

Thermal runaway wikipedia , lookup

Ground (electricity) wikipedia , lookup

Electrical ballast wikipedia , lookup

Mercury-arc valve wikipedia , lookup

Power engineering wikipedia , lookup

Stepper motor wikipedia , lookup

Islanding wikipedia , lookup

Resonant inductive coupling wikipedia , lookup

TRIAC wikipedia , lookup

Amtrak's 25 Hz traction power system wikipedia , lookup

Current source wikipedia , lookup

Ohm's law wikipedia , lookup

History of electric power transmission wikipedia , lookup

Three-phase electric power wikipedia , lookup

Power MOSFET wikipedia , lookup

Stray voltage wikipedia , lookup

Rectifier wikipedia , lookup

Surge protector wikipedia , lookup

Resistive opto-isolator wikipedia , lookup

Earthing system wikipedia , lookup

Buck converter wikipedia , lookup

Power electronics wikipedia , lookup

Voltage optimisation wikipedia , lookup

Opto-isolator wikipedia , lookup

AC adapter wikipedia , lookup

Variable-frequency drive wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Alternating current wikipedia , lookup

Mains electricity wikipedia , lookup

Transcript
Thousand Hundred Industrial Co.,Ltd.
Hall Current Sensor TK 350-CCS
For the electronic measurement of currents:DC,AC,pulsed,mixed,
with a galvanic isolation between the primary(high power)
circuit and the secondary(electronic) circuit.
IPN= 7-8-11-13-35 A
Pb
RoHS COMPLIANT
● Operating performances ( AT =25 ℃ )
Primary nominal r.m.s. current
IPN
Primary current measuring range IP
Secondary nominal r.m.s. current ISN
Measuring resistance
RM
Conversion ratio
Supply voltage
Current consumption
Linearity
Accuracy
Offset current
Thermal drift of Io
KN
VCC
IC
εL
Response time
di/dt accurately followed
Hysteresis offset current
Isolation voltage
Frequency bandwidth
X
IO
IOT
tr
di/dt
IOH
Vd
with ±
15V
35 A
A
0 .. ± 70 A
35
A
mA
RM min RM max
@ ±35Amax 60
@ ±70Amax 60
1-2-3-4-5:1000
±12~15 ( ±5% )
10(@±15V)+IS
320
85
≦±0.2 @0~±IPN
±1 @IPN,VC=±15V,TA=25 ℃,
<±0.2 @IP=0,TA=25 ℃
≦±0.6mA (type ±0.2) @-40~+85℃
<1
>50
≦±0.3 @±3IPN→0
f
2.5 @50(60)HZ/1min
0~100
TO
TS
-25~+85℃
-40~+85℃
m
24
Ω
Ω
V
mA
%
%
mA
µs
A/µs
mA
KV
KHz
● General data
Operating temperature
Storage temperature
Mass
g
● Applications
◆AC
variable speed drives and servo motor drives
◆Battery
supplied applications
◆Uninterruptible Power Supplies(UPS)
◆Static
converters for DC motor drives
◆Switched Mode Power Supplies(SMPS)
◆Power supplies for welding applications
● Advantages
◆Excellent
◆Very
◆Low
accuracy
temperature drift
◆Wide frequency bandwidth
◆Very low insertion losses
◆Optimized
T.H
good linearity
response time
◆High immunity to external interference
◆Current overload capability
www.thic.net
Thousand Hundred Industrial Co.,Ltd.
● Dimensions (unit: mm)
10.16-2.54*4 15
-
5.34
8.89
11.43
1
+
M
15.24
26
5
TK 350-CCS
18.8
23.8
29
10- 0.9
Top view
Left view
Bottom view
35A/35mA
M
+
-
1
3- 1
Secondary terminals
Terminal + : supply voltage + 15 V
Terminal M: measure
Terminal - : supply voltage - 15 V
Connection
IN
OUT
1~5
+
6~10
-
M
Mechanical characteristics
·General tolerance ± 0.2 mm
·Fastening & connection of primary 10 pins φ0.9mm
·Fastening & connection of secondary 3 pins φ 1 mm
·Recommended PCB hole 1.2 mm
◆Temperature
T.H
Is
Rm
+
0V
-
Remarks
·Is is positive when Ip flows from terminals 1, 2, 3, 4, 5 to
terminals 10, 9, 8, 7, 6
·This is a standard model. For different versions (supply
voltages, turns ratios, unidirectional measurements...),
please contact us.
of the primary conductor should not exceed 100 ℃.
www.thic.net