Weifang series HRC100/s Generator model...........................................................HWF100/s Rated Power............................................................80Kw/100Kva Standby Power.........................................................88Kw/110Kva Voltage............................................................................230/400V Frequency..............................................................................50Hz Speed..............................................................................1500rpm Type.......................................................................3 Phase 4 Wire Engine Model..................................................Weifang R6105ZLD Alternator.....................................................................HWN-274C Control System...................................................................G601A Circuit Breaker.................................................................Standard Notice:The picture is only for reference. ATS (automatic transfer switch).......................................... Option Engine: Weifang R6105ZLD Silent Level...........................................................70dB-85B at 7m Cooling Fan with fan guard and front guard Fuel Tank Capacity.........................................8-12 hours fuel tank ■ Alternator: Single bearing, IP23, H class Fuel Consumption..............................................................16.8L/h ■ 2*12V Start Battery with connection cable ■ Equipped with Shock Absorber ■ Dry Air Filter, Dual Fuel Filter, Engine Oil Filter Coolant Filter ■ Standard Control Panel, Circuit Breaker ■ Storage Battery and battery line, Exhaust pipe ■ Corrugated pipe for anti-vibration, Cone Tube, Flange, Muffler ■ ATS (automatic transfer switch) receptacle ■ Soundproof Enclosure/Canopy for optional ■ Base fuel tank for at least 8hours running ■ Equipped with an industrial muffler ■ Engine oil pump ■ Drainage for fuel tank ■ Documents ■ ■ * Voltage Available: 50Hz: 380-400-415V/220-230-240V; 60Hz: 220-380-416-440-480V/110-208-220-240V Any special voltage is also available as client’s request *Prime Power: Prime power is available for an unlimited number of annual hours in variable load Application, in accordance with GB/T2820-97 (eqv ISO8528); A 10% overload capability is available for a period of 1 hour within a 12 hour period of operation. *Standby Power: The standby power rating is applicable for supply emergency power for the duration of a utility power interruption. No overload, utility parallel or negotiated outage Operation capability is available at the rating. Dimensions and Weights Genset model Length (L) Width (W) Height(H) Weight HWF100 2550mm 900mm 1400mm 1760kg HWF100/s 2800mm 1150mm 1500mm 2200kg Notice:the size and weight is just for reference, if you Want to confirm it, please kindly confirm it with salesman,thanks. 1 ■ Diesel engine Steady state voltage regulation.............................................≤±1% Efficiency..............................................................................93.8% Cooling air flow..............................................................1.035m3/s Power Factor…………………………………………………….…0.8 ■ ATS (OPTION) Engine brand....................................................................Weifang Engine model................................................................R6105ZLD Aspiration................................................................Turbocharged Type.............................................Direct Injection, Inline,4-strokes Speed/Frequency...................................................1500rpm/50Hz Rated Power............................................................100Kw/130Hp Cylinder........................................................................................6 Displacement........................................................................6.49L Upon detection of a mains(utility) failure the module automatically starts the generator set, once the mails (utility) power has been restored it instructs the generator set to stop ■ Control panel (OPTION) Bore*Stroke..........................................................105mm*130mm Compression Ratio.................................................................16:1 Fuel consumption........................................................ ≤225g/kw.h Governing System..............................................................Electric Starting method.....................................................Electric Starting Cooling system.........................................................Water-cooled ■ Alternator Our factory have Smartgen, Deep sea, Comap,Harson or other brand controller for our customer’s choice, If you need these controller, please kindly talk with the salesman about the controller cost. ■ Single Phase& Three Phase Outlet (OPTION) Alternator model..........................................................HWN-274C Alternator manufacturer..........................................HAIWEINENG Speed/Frequency...................................................1500rpm/50Hz ■ Mobile Generator (OPTION) Two Wheels: Rated power.............................................................80Kw/100Kva Standby power.........................................................88Kw/110Kva Connection............................................................3 Phase 4 Wire Wings.......................................................................100% Copper Altitude condition...............................................................≤1000m Excitation...............................................Brushless, Self-excitation Four Wheels: Insulation class/Temp.rise class...............................................H/H Tel.influence factor TIF.............................................................<50 Tel.Harmonic Factor THF........................................................<2% 2 ■ Control system (Standard) Measure and Display The G601A is an auto control and protection module of generator. 1.The AC phase voltage of generator Vac The control modes of manual or auto are selectable by buttons 2. Generator frequency Hz on panel. Manual starts or stops Genset under manual mode by 3. Engine speed RPM (signal from generator frequency) button on panel. Auto starts or stops Genset under auto Mode by 4. Battery voltage Vdc remote switch input signal. The modules is adopted LCD, which 5. Engine running hours H displays running status and operating parameters of generator. 6. Engine coolant temperature ℃/℉ ___________________________________________________ 7. Engine oil pressure BAR/PSI (engine from engine P-Sensor) a. Generator Indicator 1.Stop/Reset/Value Descend B. Voltage Change-Over Switch 2. Auto button/LED c, Voltage Meter 3. Manual Start Button/LED d. Engine Control Module 4. Start Button e. Current Meter 5. Enter Into Submenu/menu f. Current Change-Over Switch 6. Failure LED g. Key Switch Feature Generator Protection Warning The core adopts MPU. 1. Fail to Charge 2. Battery low voltage Flexible configure running parameters via buttons 3. Battery high voltage 4. Low oil pressure 5. High temperature 6. Over speed 7. Under speed 8.High voltage Voltage for generator; battery voltage; oil pressure, 9. Low voltage 10.Auxiliary Warning coolant temp and running hours for engine. When controller detects the warning signal, only and LCD on panel. Measure and display parameters, such as frequency and - The fuel mode (NC or NO) of engine can be set by procedure. alarm and not Stop genset, the alarms are displayed Has five relays control output, others can be defined by user in LCD. except the outputs of fuel and start control are fixed. 5 channels for switch input, others can be defined by user except the inputs of oil pressure and coolant temperature Shutdown Alarm 1. Fail to start 2. Fail to stop are fixed. 3. Emergency stop 4.Low oil pressure Internal kinds of P-sensor and T-sensor for user choice. 5. High temperature 6. Over speed Optional internal communication interface can be used to 7. Auxiliary Failure configure parameters via PC. All connections are connected by pin-like and locked up terminal, easier and more convenient to connect, move, When controller detected shutdown alarm, it will Send signal to breaker off and to stop, the alarms And displayed in LCD. maintain and replace the device. 3 ■ Control system (AMF for Option) Smartgen HGM6120 Genset controller integrating digital, intelligent and network techniques is used for automatic control system of diesel generator. It can carry out functions including automatic start/stop, data measure and alarm protective. The controller uses LCD display. ___________________________________________________ 1. Stop/Reset Button 2. Manual Button 3. Auto Button 4. Running with load Button 5. Set/Confirm Button 6. Start 7. Page up/increase Button 8. Page down/ decrease Button a. Generator Indicator b. Key switch c. Engine Control Module Generator Protection Warning 1. Lost Of Speed 2. Gens Over Current Feature 6. Failed To Stop 4. Low Oil Level Using microprocessor as a core, symbol LCD with backlight 5. Charge Alternator Fail 6. Battery Low Voltage display, the three languages display Chinese, English and 7. Battery High Voltage 8. Low Water Level Spanish, Key touch operation. When controller detects the warning signal, only alarm Have a RS485 port with modus communication protocol. and not Stop genset, the alarms are displayed in LCD. Adopt to 3Phase-4Wieres, Single Phase-2 or 2 Phase-3Wire,50/60Hz AC power system. Measure and display 3 phase voltage, 3 phase current, Shutdown Alarm 1. Emergency Stop 2. High Tem Alarm 3. Lower OP Alarm 4.Over Speed Alarm 5. Under Speed Alarm 6.Speed Signal Lost Alarm Control protection: Automatic crank/stop of diesel engine. Load 7. Gens Over Voltage 8.Gens Under Voltage transfer and completely faults display protection. 9. Gens Over Current 10.Start Fail Alarm frequency, power etc Mains and Gens. Precision measure and display parameters about engine.. With ETS, idle control, pre-heat control, Raises speed control functions, and all type of them are belong to relay output. Parameter setting: Allow user to modify setting and store them by inside internal FLASH memory, the parameter can not be 11. Over Frequency Alarm 12.Under Frequency Alarm 13. Gens Failed Alarm 14.Oil Level Lower Alarm 15. Water Level Lower Alarm When controller detected shutdown alarm, it will lost even with power off, all of parameters can be set not only Send signal to breaker off and to stop, the alarms from the front panel, but By PC via SG72 (an adaptor, And displayed in LCD USD-LINK-RS485) module, or through RS485 port Via PC All parameters use digital modulation, abandoning analog Modulation using conventional electronic potentiometer, more Reliability and Stability. 4 ■ Standard Accessories Standard Battery Battery Charger Battery Wire Flexible Pipe Cooling Radiator Float Battery Charger Control System Base Frame Flange Wire diagram Manual Book ATS External Fuel Tank Silent Canopy PMG Water Preheater Synchronization Automatic Fuel Tank Weatherproof Auto-condensation Lub Oil Preheater Canopy heater Mobile trial Paralles droop ■ Standard Accessories Panel ABB Breaker Oil Drain Pump Spare parts ■ Generator Structure ■ Quality Assurance Factory Inspection, the test items before delivery are mainly as follows: 1. Each genset shall be put into commission more than 4 hours totally. 2. They are tested on idle load, fully load and 110% overload; 3. The noise level is tested 4. All of the meters on the control panel shall be tested 5. The appearance of the genset and all of the label and nameplate shall be checked Warranty 12 months or 1000 running hours from shipment date. If the quality problem arise during the warranty period,and verified the problem is caused by our genset-body instead of external or natural reasons. (Refer to all kinds of natural disaster, shipping, loading, unloading, wrong-operation, etc),we will supply the relevant spare parts free of 5 charge for maintenance;after the warranty period, we can supply the required spare parts for you under cost prices. ■ HAIWEINENG SILENT GENERATOR OVERVIES HAIWEINENG Silent generator is designed according to the international quality standard, which meet the special requirements of environmental protection and user , scientific design, acoustics, air flow in the field of advanced technology, lower noise, adapt to the city environmental requirements mute cover , good ventilation series and prevent heat radiation measures to ensure that the unit is always working in a suitable environment temperature. Generator Feature * Good ventilation system and prevent heat radiation measures to ensure that the unit is always working in a suitable environment temperature * Large capacity base fuel tank, available for 8 to 12 hours continuous load operation * Dedicated noise reduction silencer material, to a great extent suppression of mechanical noise * The efficient damping measures to ensure the smooth running of the diesel generator set * The appropriate location of the muffler shell dedicated observation window and emergency stop button , convenient to use operation and observation unit operating status The Installation of Generator 1 , the installation site need to maintain good ventilation , generator terminal should have sufficient air inlet , the diesel engine side should be a good outlet . The vent area should be greater than 1.5 times more than the area of the tank. 2, the installation of around should be kept clean to avoid the items placed in the vicinity of acidic, alkaline and other corrosive gases and vapors can produce . Conditional fire extinguishing devices should be configured. 3. for indoor use, you must exhaust pipes pass to the outdoor, the diameter must be ≥ muffler smoke tube diameter, connected to the pipes of the elbow should not be more than 3 to ensure the smooth flow of exhaust gas, and shall pipe downward-sloping 5 - 10 degrees, avoid rain water injection; exhaust pipe is installed vertically upwards, you must install rain cover. 4. The concrete foundation is required in the installation Use the level to measure the level of the unit fixed on the basis of the level. Between the unit and the foundation should be a dedicated anti-vibration pad or foot bolt. 5, the unit housing must have reliable protection grounding directly grounded neutral point generator, it must be carried out by professionals neutral ground, and equipped with lightning protection devices, prohibit the use of the the mains grounding device neutral point directly to ground. 6, the two-way switch for generator and mains must be very reliable, to prevent reverse power transmission. Two-way switch wiring reliability and subject to the approval of the inspection of the local electricity sector. 7 starter battery connections must be secure. Generator Application The Silent Generator widely used: defense , hospitals , hotels , schools , factories , families , construction , building ,Telecommunications, marine , industrial and mining enterprises , railway and highway construction , oil exploration , water conservancy construction , can be used as a backup power supply or emergency power supply . 6 Generator Transportation 1.Forkman hole can be choice 2.Lifting hole is standard mounted in the base fuel tank The Certificate of Generator Quality 1. Certificate of Europe (CE) 2. China Compulsory Certification (CCC) 3. International Organization for Standardization (ISO) 4. Standards Organization of Nigeria (SONCAP) Note:We also can make SASO, COC, PVOC, BV etc for our customer. Please contact with salesman for these fee, thanks. FUJIAN HAIWEINENG ELECTRICAL MACHINERY CO.,LTD Add: No.37.Jinsha East Road, Yangtou Street, Distributed by Fuan City, Fujian Province, China Tel:+86-593-6616768 Fax:+86-593-6580466 All information in this documents is just for reference only, if any changes without Notice,thanks. 7