Download HRC100/s

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Power engineering wikipedia , lookup

Control system wikipedia , lookup

Electrical substation wikipedia , lookup

Stray voltage wikipedia , lookup

Electrification wikipedia , lookup

Pulse-width modulation wikipedia , lookup

Islanding wikipedia , lookup

Buck converter wikipedia , lookup

Power electronics wikipedia , lookup

Variable-frequency drive wikipedia , lookup

Three-phase electric power wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Voltage optimisation wikipedia , lookup

Alternating current wikipedia , lookup

Distribution management system wikipedia , lookup

Mains electricity wikipedia , lookup

Transcript
Weifang series
HRC100/s
Generator model...........................................................HWF100/s
Rated Power............................................................80Kw/100Kva
Standby Power.........................................................88Kw/110Kva
Voltage............................................................................230/400V
Frequency..............................................................................50Hz
Speed..............................................................................1500rpm
Type.......................................................................3 Phase 4 Wire
Engine Model..................................................Weifang R6105ZLD
Alternator.....................................................................HWN-274C
Control System...................................................................G601A
Circuit Breaker.................................................................Standard
Notice:The picture is only for reference.
ATS (automatic transfer switch).......................................... Option
Engine: Weifang R6105ZLD
Silent Level...........................................................70dB-85B at 7m
Cooling Fan with fan guard and front guard
Fuel Tank Capacity.........................................8-12 hours fuel tank
■
Alternator: Single bearing, IP23, H class
Fuel Consumption..............................................................16.8L/h
■
2*12V Start Battery with connection cable
■
Equipped with Shock Absorber
■
Dry Air Filter, Dual Fuel Filter, Engine Oil Filter Coolant Filter
■
Standard Control Panel, Circuit Breaker
■
Storage Battery and battery line, Exhaust pipe
■
Corrugated pipe for anti-vibration, Cone Tube, Flange, Muffler
■
ATS (automatic transfer switch) receptacle
■
Soundproof Enclosure/Canopy for optional
■
Base fuel tank for at least 8hours running
■
Equipped with an industrial muffler
■
Engine oil pump
■
Drainage for fuel tank
■
Documents
■
■
* Voltage Available:
50Hz: 380-400-415V/220-230-240V;
60Hz: 220-380-416-440-480V/110-208-220-240V
Any special voltage is also available as client’s request
*Prime Power: Prime power is available for an unlimited number of annual
hours in variable load Application, in accordance with GB/T2820-97 (eqv
ISO8528); A 10% overload capability is available for a period of 1 hour within
a 12 hour period of operation.
*Standby Power: The standby power rating is applicable for supply emergency
power for the duration of a utility power interruption. No overload, utility
parallel or negotiated outage Operation capability is available at the rating.
Dimensions and Weights
Genset model
Length (L)
Width (W)
Height(H)
Weight
HWF100
2550mm
900mm
1400mm
1760kg
HWF100/s
2800mm
1150mm
1500mm
2200kg
Notice:the size and weight is just for reference, if you
Want to confirm it, please kindly confirm it with salesman,thanks.
1
■ Diesel engine
Steady state voltage regulation.............................................≤±1%
Efficiency..............................................................................93.8%
Cooling air flow..............................................................1.035m3/s
Power Factor…………………………………………………….…0.8
■ ATS (OPTION)
Engine brand....................................................................Weifang
Engine model................................................................R6105ZLD
Aspiration................................................................Turbocharged
Type.............................................Direct Injection, Inline,4-strokes
Speed/Frequency...................................................1500rpm/50Hz
Rated Power............................................................100Kw/130Hp
Cylinder........................................................................................6
Displacement........................................................................6.49L
 Upon detection of a mains(utility) failure the module
automatically starts the generator set, once the mails (utility)
power has been restored it instructs the generator set to stop
■ Control panel (OPTION)
Bore*Stroke..........................................................105mm*130mm
Compression Ratio.................................................................16:1
Fuel consumption........................................................ ≤225g/kw.h
Governing System..............................................................Electric
Starting method.....................................................Electric Starting
Cooling system.........................................................Water-cooled
■ Alternator
Our factory have Smartgen, Deep sea, Comap,Harson or other
brand controller for our customer’s choice, If you need these
controller, please kindly talk with the salesman about the
controller cost.
■ Single Phase& Three Phase Outlet (OPTION)
Alternator model..........................................................HWN-274C
Alternator manufacturer..........................................HAIWEINENG
Speed/Frequency...................................................1500rpm/50Hz
■ Mobile Generator (OPTION)
Two Wheels:
Rated power.............................................................80Kw/100Kva
Standby power.........................................................88Kw/110Kva
Connection............................................................3 Phase 4 Wire
Wings.......................................................................100% Copper
Altitude condition...............................................................≤1000m
Excitation...............................................Brushless, Self-excitation
Four Wheels:
Insulation class/Temp.rise class...............................................H/H
Tel.influence factor TIF.............................................................<50
Tel.Harmonic Factor THF........................................................<2%
2
■ Control system (Standard)
Measure and Display
The G601A is an auto control and protection module of generator.
1.The AC phase voltage of generator Vac
The control modes of manual or auto are selectable by buttons
2. Generator frequency Hz
on panel. Manual starts or stops Genset under manual mode by
3. Engine speed RPM (signal from generator frequency)
button on panel. Auto starts or stops Genset under auto Mode by
4. Battery voltage Vdc
remote switch input signal. The modules is adopted LCD, which
5. Engine running hours H
displays running status and operating parameters of generator.
6. Engine coolant temperature ℃/℉
___________________________________________________
7. Engine oil pressure BAR/PSI (engine from engine P-Sensor)
a. Generator Indicator
1.Stop/Reset/Value Descend
B. Voltage Change-Over Switch
2. Auto button/LED
c, Voltage Meter
3. Manual Start Button/LED
d. Engine Control Module
4. Start Button
e. Current Meter
5. Enter Into Submenu/menu
f. Current Change-Over Switch
6. Failure LED
g. Key Switch
Feature
Generator Protection
Warning
 The core adopts MPU.
1. Fail to Charge
2. Battery low voltage
 Flexible configure running parameters via buttons
3. Battery high voltage
4. Low oil pressure
5. High temperature
6. Over speed
7. Under speed
8.High voltage
Voltage for generator; battery voltage; oil pressure,
9. Low voltage
10.Auxiliary Warning
coolant temp and running hours for engine.
 When controller detects the warning signal, only
and LCD on panel.
 Measure and display parameters, such as frequency and
-
 The fuel mode (NC or NO) of engine can be set by procedure.
alarm and not Stop genset, the alarms are displayed
 Has five relays control output, others can be defined by user
in LCD.
except the outputs of fuel and start control are fixed.
 5 channels for switch input, others can be defined by user
except the inputs of oil pressure and coolant temperature
Shutdown Alarm
1. Fail to start
2. Fail to stop
are fixed.
3. Emergency stop
4.Low oil pressure
 Internal kinds of P-sensor and T-sensor for user choice.
5. High temperature
6. Over speed
 Optional internal communication interface can be used to
7. Auxiliary Failure
configure parameters via PC.
 All connections are connected by pin-like and locked up
terminal, easier and more convenient to connect, move,
 When controller detected shutdown alarm, it will
Send signal to breaker off and to stop, the alarms
And displayed in LCD.
maintain and replace the device.
3
■ Control system (AMF for Option)
Smartgen HGM6120 Genset controller integrating digital,
intelligent and network techniques is used for automatic control
system of diesel generator. It can carry out functions including
automatic start/stop, data measure and alarm protective. The
controller uses LCD display.
___________________________________________________
1.
Stop/Reset Button
2.
Manual Button
3.
Auto Button
4.
Running with load Button
5.
Set/Confirm Button
6.
Start
7.
Page up/increase Button
8.
Page down/ decrease Button
a. Generator Indicator
b. Key switch
c. Engine Control Module
Generator Protection
Warning
1. Lost Of Speed
2. Gens Over Current
Feature
6. Failed To Stop
4. Low Oil Level
 Using microprocessor as a core, symbol LCD with backlight
5. Charge Alternator Fail
6. Battery Low Voltage
display, the three languages display Chinese, English and
7. Battery High Voltage
8. Low Water Level
Spanish, Key touch operation.
 When controller detects the warning signal, only alarm
 Have a RS485 port with modus communication protocol.
and not Stop genset, the alarms are displayed in LCD.
 Adopt to 3Phase-4Wieres, Single Phase-2 or 2
Phase-3Wire,50/60Hz AC power system.
 Measure and display 3 phase voltage, 3 phase current,
Shutdown Alarm
1. Emergency Stop
2. High Tem Alarm
3. Lower OP Alarm
4.Over Speed Alarm
5. Under Speed Alarm
6.Speed Signal Lost Alarm
Control protection: Automatic crank/stop of diesel engine. Load
7. Gens Over Voltage
8.Gens Under Voltage
transfer and completely faults display protection.
9. Gens Over Current
10.Start Fail Alarm
frequency, power etc Mains and Gens.
 Precision measure and display parameters about engine..
 With ETS, idle control, pre-heat control, Raises speed control
functions, and all type of them are belong to relay output.
 Parameter setting: Allow user to modify setting and store them
by inside internal FLASH memory, the parameter can not be
11. Over Frequency Alarm 12.Under Frequency Alarm
13. Gens Failed Alarm
14.Oil Level Lower Alarm
15. Water Level Lower Alarm
 When controller detected shutdown alarm, it will
lost even with power off, all of parameters can be set not only
Send signal to breaker off and to stop, the alarms
from the front panel, but By PC via SG72 (an adaptor,
And displayed in LCD
USD-LINK-RS485) module, or through RS485 port Via PC
 All parameters use digital modulation, abandoning analog
Modulation using conventional electronic potentiometer, more
Reliability and Stability.
4
■ Standard Accessories
Standard Battery
Battery Charger
Battery Wire
Flexible Pipe
Cooling Radiator
Float Battery Charger
Control System
Base Frame
Flange
Wire diagram
Manual Book
ATS
External Fuel Tank
Silent Canopy
PMG
Water Preheater
Synchronization
Automatic Fuel Tank
Weatherproof
Auto-condensation
Lub Oil Preheater
Canopy
heater
Mobile trial
Paralles droop
■ Standard Accessories
Panel
ABB Breaker
Oil Drain Pump
Spare parts
■ Generator Structure
■ Quality Assurance
Factory Inspection, the test items before delivery are mainly as follows:
1. Each genset shall be put into commission more than 4 hours totally.
2. They are tested on idle load, fully load and 110% overload;
3. The noise level is tested
4. All of the meters on the control panel shall be tested
5. The appearance of the genset and all of the label and nameplate shall be checked
 Warranty
12 months or 1000 running hours from shipment date. If the quality problem arise during the warranty period,and
verified the problem is caused by our genset-body instead of external or natural reasons. (Refer to all kinds of
natural disaster, shipping, loading, unloading, wrong-operation, etc),we will supply the relevant spare parts free of
5
charge for maintenance;after the warranty period, we can supply the required spare parts for you under cost prices.
■ HAIWEINENG SILENT GENERATOR OVERVIES
HAIWEINENG Silent generator is designed according to the international quality standard, which meet the
special requirements of environmental protection and user , scientific design, acoustics, air flow in the field of
advanced technology, lower noise, adapt to the city environmental requirements mute cover , good ventilation
series and prevent heat radiation measures to ensure that the unit is always working in a suitable
environment temperature.
 Generator Feature
* Good ventilation system and prevent heat radiation measures to ensure
that the unit is always working in a suitable environment temperature
* Large capacity base fuel tank, available for 8 to 12 hours continuous load operation
* Dedicated noise reduction silencer material, to a great extent suppression of mechanical noise
* The efficient damping measures to ensure the smooth running of the diesel generator set
* The appropriate location of the muffler shell dedicated observation window and
emergency stop button , convenient to use operation and observation unit operating status
 The Installation of Generator
1 , the installation site need to maintain good ventilation , generator terminal should have sufficient air inlet , the
diesel engine side should be a good outlet . The vent area should be greater than 1.5 times more than the area of
the tank.
2, the installation of around should be kept clean to avoid the items placed in the vicinity of acidic, alkaline and
other corrosive gases and vapors can produce . Conditional fire extinguishing devices should be configured.
3. for indoor use, you must exhaust pipes pass to the outdoor, the diameter must be ≥ muffler smoke tube
diameter, connected to the pipes of the elbow should not be more than 3 to ensure the smooth flow of exhaust gas,
and shall pipe downward-sloping 5 - 10 degrees, avoid rain water injection; exhaust pipe is installed vertically
upwards, you must install rain cover.
4. The concrete foundation is required in the installation Use the level to measure the level of the unit fixed on the
basis of the level. Between the unit and the foundation should be a dedicated anti-vibration pad or foot bolt.
5, the unit housing must have reliable protection grounding directly grounded neutral point generator, it must be
carried out by professionals neutral ground, and equipped with lightning protection devices, prohibit the use of the
the mains grounding device neutral point directly to ground.
6, the two-way switch for generator and mains must be very reliable, to prevent reverse power transmission.
Two-way switch wiring reliability and subject to the approval of the inspection of the local electricity sector.
7 starter battery connections must be secure.
 Generator Application
The Silent Generator widely used: defense , hospitals , hotels , schools , factories , families , construction ,
building ,Telecommunications, marine , industrial and mining enterprises , railway and highway construction , oil
exploration , water conservancy construction , can be used as a backup power supply or emergency power
supply .
6
 Generator Transportation
1.Forkman hole can be choice
2.Lifting hole is standard mounted in the base fuel tank
 The Certificate of Generator Quality
1. Certificate of Europe (CE)
2. China Compulsory Certification (CCC)
3. International Organization for Standardization (ISO)
4. Standards Organization of Nigeria (SONCAP)
Note:We also can make SASO, COC, PVOC, BV etc for our customer. Please contact with salesman for these fee, thanks.
FUJIAN HAIWEINENG ELECTRICAL MACHINERY CO.,LTD
Add: No.37.Jinsha East Road, Yangtou Street,
Distributed by
Fuan City, Fujian Province, China
Tel:+86-593-6616768
Fax:+86-593-6580466
All information in this documents is just for reference only, if any changes without Notice,thanks.
7