Download CLASSIC LINE Eibiswald

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Mercury-arc valve wikipedia , lookup

Three-phase electric power wikipedia , lookup

Electric machine wikipedia , lookup

Electrical substation wikipedia , lookup

Ohm's law wikipedia , lookup

Variable-frequency drive wikipedia , lookup

Current source wikipedia , lookup

Coilgun wikipedia , lookup

History of electric power transmission wikipedia , lookup

Electromagnetic compatibility wikipedia , lookup

Voltage regulator wikipedia , lookup

Rectifier wikipedia , lookup

Resistive opto-isolator wikipedia , lookup

Voltage optimisation wikipedia , lookup

Stray voltage wikipedia , lookup

Power electronics wikipedia , lookup

Surge protector wikipedia , lookup

Metadyne wikipedia , lookup

Buck converter wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Mains electricity wikipedia , lookup

Alternating current wikipedia , lookup

Network analysis (electrical circuits) wikipedia , lookup

Opto-isolator wikipedia , lookup

Solenoid wikipedia , lookup

Transcript
direct current single direction linear solenoids
direct current bistable miniature linear
solenoids
kec
group
power of partnership and magnetism
classic line eibiswald
s m a l l p o w e rf u l
e
l
b
i
x
fle
about us
The KENDRION ELECTROMAGNETIC COMPONENTS Group
Our many years of experience in the development and
(KEC Group) sees itself as a centre of excellence in the field
manufacture of electromagnetic devices plus the skills and
of electromagnetism.
commitment of our employees enable us to recognise the
KENDRION MAGNETTECHNIK GmbH develops and
needs of the market. And we turn those needs into high-
manufactures a wide range of electromagnetic products in
quality products in cooperation with our customers.
the most diverse variations and designs for countless
technical applications. The company grew out of the
traditional operations of Binder, Thoma and Neue Hahn
We at KENDRION MAGNETTECHNIK achieve customer-
and is now Europe’s leading manufacturer of electro-
focused solutions in all corporate divisions.
magnetic components.
Those solutions bring maximum benefits for customers
and hence considerably strengthen their position in their
The Eibiswald works of KENDRION MAGNETTECHNIK
markets.
acts as the skills centre for small solenoid project
business.
We enter into development partnerships with our
customers not only to develop classic solenoids but also
• Customer-oriented market management
complete system solutions to meet specific local
• Innovative product development
conditions, requirements and economic demands. In
• Development partnerships
order to safeguard our customer’s competitive position,
• Automated manufacture
our constant aim is to manufacture equipment which
• Process-oriented logistics
meets market demands and which is also located at the
• And the power of magnetism ensure the success
optimum point on the cost/benefit curve.
kendri
2
of KENDRION MAGNETTECHNIK
l
k
o
i
n
s
o n m a g n e tt e c hone-stop
yo u r
www.kendrionmt.com
n
o
i
ut
classic line
Type 42E20108A04
Type 4000118AE29
Type 4000625AE19
Type 4000628AE34
Direct current single direction linear solenoids
Bistable direct current miniature linear solenoids
Direct current single direction linear solenoids are widely used as cost-effective
activating solenoids in precision engineering, industrial and locking/latching
applications.
They can be used in almost any position and push or pull actuation is possible.
Their use is, however, limited to axial movements as lateral loads lead to
increased bearing wear.
Further information on the use of electromagnetic devices can be obtained
from the Data Sheet “Technical Background”.
CE marks on solenoids and electronic components
Electromagnets, electromagnetic devices
Information on their working life and switching frequency can be obtained
from the manufacturer.
The electromagnetic products of Kendrion Magnettechnik are components for
incorporation and operation in electrical equipment and devices.
They therefore do not fall within the remit of the Low Voltage Directive
73/23/EEC.
The application of an electromagnetic force brings about a linear movement
from the initial position to the end position. The return movement is achieved
by a return spring or a permanent magnet. The devices are not fitted with a
plunger stop as standard.
However, the components comply with various standards for incorporation and
operation in devices covered by the Low Voltage Directive, in particular
DIN VDE 0580 / 07.2000. The corresponding data is given on the data sheets
for the individual components.
Modifications on request. For further information please contact
[email protected]
Tel: +43 (0) 34 66 42 3 22 21
Fax: +43 (0) 34 66 42 7 32
Standard rated voltage:
Standard duty cycle:
24V DC
100 %
The relative duty cycle is related to a maximum cycle time of 5 minutes.
Other voltages, duty cycles not given in the tables and stroke adjustments
available for an extra charge.
Maximum ambient temperature: 35°C
Thermal class:
Direct current single direction linear solenoids:
Bistable direct current miniature linear solenoids:
The products are manufactured and tested to
DIN VDE 0580 / 07.2000
F
E
On the other hand, the products are components in the meaning of the
Machinery Directive 98/37/EC. According to this directive, such products
incorporated in a machine may not be operated until the machine’s conformity
with the EC directive has been established.
A manufacturer’s declaration, which is not automatically supplied with the
product, can be obtained on request.
The user must ensure conformity with the EMC Directive 89/336/EEC by using
suitable switching devices or controls. When using the recommended electronic
switching devices and controls from Kendrion Magnettechnik, conformity with
the EMC Directive is stated on the appropriate data sheets.
Notes:
- Complies with DIN VDE 0580/7.2000 ICS29.020.53.020.01
(valid as the Manufacturer’s Declaration of Conformity)
- Directives 98/37/EC and 73/23/EEC
- CCC certificate for China not required
We reserve the right to make changes to the product design.
Protection Type: to IEC 60529
www.kendrionmt.com
3
direct current bistable miniature linear solenoids
Type 42E20108A04
Dimensions
Options
Position: II
Position: I
Stroke
Marking
Please enquire by contacting:
[email protected]
Phone: +43 (0) 34 66 42 3 22 21
Fax: +43 (0) 34 66 42 7 32
or your local partner
Design
Pin connection. Protection type: IPOD
to IEC 60529
Insulation class E
to DIN VDE 580/07.2000
The magnetic forces indicated are for
devices at operating temperature and
for 90% of the rated voltage. They are
achieved when moving horizontally and
apply for a supply voltage of 4.5V DC.
Other voltages and stroke adjustments
are available at a surcharge.
Different supply voltages may lead to
magnetic forces higher or lower than
the specified values owing to the changing copper factor.
Stroke
(in mm)
Unenergised
holding force
(in N)
0
0.1
2.5
0.05
4
Bistable direct current miniature linear solenoids
Bistable direct current miniature linear solenoids are
double-action linear solenoids for short term and
intermittent duty. After the response phase the
integral permanent magnets hold the plunger in the
end position with a specific holding force in the
unergenised state.
The electromagnetic force is used essentially for the
linear movement and the permanent magnetic force
to hold the plunger in the end position without the
use of electrical energy.
The return movement (overcoming the force of the
permanent magnets) is triggered by a reversed,
possibly lower, voltage impulse depending on the
magnitude of an external return force.
The integral return spring moves the plunger back to
the start position.
The customer can fix the solenoid can be fixed in
position by attachment screw on the external diameter.
Parts at risk of corrosion are electro-galvanised to
EN 12329. The plunger is electro-plated with nickel
to EN ISO 4526.
The holding forces of the permanent magnets in the
de-energised state are also reached at the operating
temperature.
Typical starting current:
0.3 A
Minimum release current: 0.2 A
Maximum release current: 0.4 A
Note:
No characteristic curve is given for this type.
This bistable direct current linear solenoid has very limited force and is switched backwards and forwards between
the two end positions.
www.kendrionmt.com
direct current single direction
linear solenoids
gleichstrom
- einfachhubmagnete
Dimensions
Type 4000118AE29
Solenoid in the energised state
Solenoid in the unenergised state
Marking
Options
Please enquire by contacting:
[email protected]
Phone: +43 (0) 34 66 42 3 22 21
Fax: +43 (0) 34 66 42 7 32
or your local partner
Stroke 8mm
Direct current single direction linear solenoids
The 400118AE29 direct current single direction linear
solenoid is an open construction solenoid with a
plunger and a punched C frame.
Maintenance-free DU bearings are used for the
plunger guides on both the axis and the plunger.
These bearings guarantee a long working life and are
not sensitive to lateral forces. A brass sleeve is used
for the bearing for shorter switching cycles.
The solenoid is fixed to the base of the C-frame by
screws.
Parts at risk of corrosion are galvanised and passivated
to EN 12329. The plunger is electro-plated with nickel to
EN ISO 4526.
Electromagnetic forces move the plunger from the start
to the end position; the plunger is returned to its initial
position by a compression spring.
They can be used in almost any position. Their use is,
however, limited to axial movements as lateral loads
lead to increased bearing wear.
4000118AE29 without spring
Duty Cycle Nominal output
(in %)
(in W)
20
100%
40%
5%
18
100
6
16
40
11.1
14
5
71.1
Force [N]
If additional output is required, a more highly
powered model can be supplied on request.
However, a cooling surface (Al) of minimum
200 x 100 x 3 mm must be available for
models with increased nominal output.
12
Design
Lead wires. Protection type:
IPOD to IEC 60529.
Insulation class F
to DIN VDE 580/17.2000.
The magnetic forces indicated are for
devices at operating temperature and
for 90% of the rated voltage. Alterations
in the magnetic force of + / - 10% can
occur due to perfectly natural variations.
Standard rated voltage = 24V DC
Standard duty cycle
= 100%
Other voltages, duty cycles not given in
the tables and stroke adjustments are
available at an extra charge.
Different supply voltages may lead to
magnetic forces higher or lower than
the specified values owing to the
changing copper factor.
10
8
6
4
2
0
0
2
4
www.kendrionmt.com
6
8
Stroke [mm]
5
direct current single direction linear solenoids
Dimensions
Insulation stripped
and galvanised
Type 4000625AE19
Sealed
Stroke
Options
Please enquire by contacting:
[email protected]
Phone: +43 (0) 34 66 42 3 22 21
Fax: +43 (0) 34 66 42 7 32
or your local partner
Direct current single direction linear solenoids
The 400625AE19 direct current single direction linear
solenoid is a solenoid with an enclosed construction
with a plunger, a punched frame and 2 plates.
Maintenance-free DU bearings are used for the
plunger guides on both the axis and the plunger. These
bearings guarantee a long working life and are not
sensitive to lateral forces. Brass or plastic bearings are
used for the bearing for shorter switching cycles. The
solenoid is fixed by screws/bolts either at the side or
the base of the frame.
Parts at risk of corrosion are galvanised and passivated to
EN 12329. The plunger is electro-plated with nickel to
EN ISO 4526.
Electromagnetic forces move the plunger from the start to
the end position; the plunger is returned to its start position
by a compression spring. They can be used in almost any
position. Their use is, however, limited to in axial movements as lateral loads lead to increased bearing wear.
If the supply voltage is, for example, 230V AV, the solenoid can be optionally supplied with a rectifier.
4000625AE19 without spring
Duty cycle Nominal output
(in %)
(in W)
100
9.2
40
17.3
5
152
25
20
If additional output is required, a more highly
powered model can be supplied on request.
However, a cooling surface (Al) of minimum
200 x 100 x 3 mm must be available for
models with increased nominal output.
15
10
5
0
6
100%
40%
5%
Force [N]
Design
Lead wires, Protection type:
IPOD to IEC 60529.
Insulation class F to
DIN VDE 580/17.2000.
The magnetic forces indicated are for
devices at operating temperature and
for 90% of the rated voltage.
Differences in the magnetic force of
+ / - 10% can occur due to perfectly
natural variations.
Standard rated voltage = 24V DC
Standard duty cycle
= 100%
Other voltages, duty cycles not given in
the tables and stroke adjustments are
available at an extra charge.
Different supply voltages may lead to
magnetic forces higher or lower than
the specified values owing to the
changing copper factor.
www.kendrionmt.com
0
2
4
6
8
Stroke [mm]
direct current single direction
linear solenoids
gleichstrom
- einfachhubmagnete
Type 4000628AE34
Stroke 10mm
Dimensions
Marking
Options
Please enquire by contacting:
[email protected]
Phone: +43 (0) 34 66 42 3 22 21
Fax: +43 (0) 34 66 42 7 32
or your local partner
Duty cycle Nominal output
(in %)
(in W)
100
13.4
40
25.6
5
180
If additional output is required, a more highly
powered model can be supplied on request.
However, a cooling surface (Al) of minimum
200 x 100 x 3 mm must be available for
models with increased nominal output.
Parts at risk of corrosion are galvanised and passivated to
EN 12329. The plunger is electro-plated with nickel to
EN ISO 4526.
Electromagnetic forces move the plunger from the start to
the end position; the plunger is returned to its start position
by a compression spring. They can be used in almost
position. Their use is, however, limited to in axial
movements as lateral loads lead to increased bearing wear.
If the supply voltage is, for example, 230V AV, the solenoid
can be optionally supplied with a rectifier.
4000628AE34 without spring
50
100%
40%
5%
40
30
Design
Plug-in connector 6.3 x 0.8 mm.
Protection type: IPOD to IEC 60529.
Insulation class F to
DIN VDE 580/17.2000.
The magnetic forces indicated are for
devices at operating temperature and
for 90% of the rated voltage. Changes
in the magnetic force of + / - 10% can
occur due to perfectly natural variations.
Standard rated voltage = 24V DC
Standard duty cycle
= 100%
Other voltages, duty cycles not given in
the tables and stroke adjustments are
available at an extra charge.
Different supply voltages may lead to
magnetic forces higher or lower than
the specified values owing to the
changing copper factor.
Force [N]
Direct current single direction linear solenoids
The 4000628AE34direct current single direction linear
solenoid is a solenoid with an enclosed construction
with a plunger, a punched frame and 2 plates.
Maintenance-free DU bearings are used for the
plunger guides on both the axis and the plunger.
These bearings guarantee a long working life and are
not sensitive to lateral forces. Brass or plastic
bearings are used for the bearings for shorter
switching cycles. The solenoid is fixed by screws/bolts
at the side.
20
10
0
0
2
4
6
www.kendrionmt.com
8
10
Stroke [mm]
7
kendrion magnettechnik worldwide
Kendrion Magnettechnik GmbH
August-Fischbach-Strasse 1
78166 Donaueschingen
Germany
Tel. +49 (0) 77 1 80 09-0
Fax +49 (0) 77 1 80 09-63 4
www.kendrionmt.com
[email protected]
Engelswies Works
Fred-Hahn-Strasse 33
72514 Inzigkofen-Engelswies, Germany
Tel. +49 (0) 75 75 20 8-0
Fax +49 (0) 75 75 20 8-1 90
www.kendrionmt.com
[email protected]
Kendrion Binder Magnete
Ges.m.b.H.
8552 Eibiswald 269, Austria
Tel. +43 (0) 34 66 42 32 2-0
Fax +43 (0) 34 66 42 72 2
[email protected]
Kendrion Binder Componentes,
S.L.
Parque Industrial “El Poligono”
c/.Rio Arba, 25
50410 Cuarte de Huerva /
Zaragoza, Spain
Tel. +34 9 76 46 30 40
Fax +34 9 76 46 30 42
[email protected]
Technical offices (Germany)
Kendrion Magnettechnik GmbH
Technisches Büro West
Bottroper Strasse 15
46244 Bottrop
Tel. +49 (0) 20 45 41 34 34
Fax +49 (0) 20 45 40 64 26
www.kendrionmt.com
[email protected]
Kendrion Magnettechnik GmbH
Technisches Büro Nord
Delmer Bogen 71
21614 Buxtehude
Tel. +49 (0) 41 61 73 37 77
Fax +49 (0) 41 61 60 07 39 3
www.kendrionmt.com
[email protected]
Representatives (Germany)
VOR-Steuerungstechnik
Friedrich Rudolph GmbH
Wichernstrasse 9
50389 Wesseling
Tel. +49 (0) 22 36 94 27 88
Fax +49 (0) 22 36 84 27 86
[email protected]
www.vor.de
Claus Kähne
Industrievertretungen GmbH
Kurmainzer Str. 199a
65936 Frankfurt
Tel. +49 (0) 69 34 05 90 20
Fax +49 (0) 69 34 05 90 27
[email protected]
RUG
Regler- und Gerätebau GmbH
Karl-Ehmann-Str. 50
73037 Göppingen
Tel. +49 (0) 71 61 85 70
Fax +49 (0) 71 61 85 72 9
[email protected]
Antriebstechnik Laipple GmbH
Burgstrasse 84
73614 Schorndorf
Tel. +49 (0) 71 81 97 94 92
Fax +49 (0) 71 81 97 94 93
[email protected]
Winfried Kerner GmbH
Ingenieurbüro
Kiebitzweg 11
85375 Neufahrn
Tel. +49 (0) 81 65 52 45
Fax +49 (0) 81 65 62 12 8
www.kerner-gmbh.de
[email protected]
Hans-Christian Pilder
Wirtschaftsingenieur
Ablers 119
88175 Scheidegg
Tel. +49 (0) 17 17 23 13 31
Fax +49 (0) 83 81 94 87 62
www.kendrionmt.com
[email protected]
Representatives (worldwide)
Austria
Kendrion Binder Magnete
Vertriebs. GmbH
Estermannstrasse 27
4020 Linz
Tel. +43 (0) 7 32 77 63 83
Fax +43 (0) 7 32 78 35 58
www.kendrion-binder.at
[email protected]
Belgium, Luxembourg
Bintz technics N.V.
Brixtonlaan 25
1930 Zaventem
Tel. +32 (0) 2 7 20 49 16
Fax +32 (0) 2 7 20 37 50
www.bintz-technics.be
[email protected]
Canada
VL Motion Systems Inc.
1105 Goodson Cres.
Oakville, Ontario L6H4A7
Tel. +01 905 842 0244
Fax +01 905 844 1293
[email protected]
Denmark
Lind Jacobsen & Co. A / S
Blokken 62
3460 Birkerød
Tel. +45 (0) 45 81 82 22
Fax +45 (0) 45 82 10 22
www.lind-jacobsen.dk
[email protected]
Desim Elektronik APS
Tasingevej 15
9500 Hobro
Tel. +45 (0) 70 22 00 66
Fax +45 (0) 70 22 22 20
www.desim.dk
[email protected]
Farstrup & Benzon A/S
Engholmvej 1, Saunte
3100 Hombaek
Tel. +45 (0) 49 70 40 33
Fax +45 (0) 49 70 40 32
www.safeline.dk
f&[email protected]
Finland
SKS-mekaniikka Oy
Martinkyläntie 50
P.O. Box 122
01721 Vantaa
Tel. +358 (0) 98 52 66 1
Fax +358 (0) 98 52 68 20
www.sks.fi
[email protected]
Moeller Electric Oy
Sahaajankatu 24
00811 Helsinki
Tel. +358 (0) 9 25 25 21 00
Fax +358 (0) 9 25 25 21 77
www.moeller.fi
[email protected]
France
Binder Magnetic
1, Allée des Barbanniers
92632 Gennevilliers Cedex
Tel. +33 (0) 1 46 13 80 80
Fax +33 (0) 1 46 13 80 99
[email protected]
Italy
SPII S.p.A
Via Don Volpi 37
21047 Saronno (VA)
Tel. +39 (0) 2 96 22 921
Fax +39 (0) 2 96 09 611
www.spii.it
[email protected]
Netherlands
Solar Electro B. V.
Effect 5
6921 RG Duiven
Tel. +31 (0) 26 3 65 29 11
Fax +31 (0) 26 3 65 23 90
www.solarelektro.nl
[email protected]
GTI Electroproject B.V.
Grote Tocht 102
1507 CE-Zaandam
Tel. +31 (0) 75 68 11 11 1
Fax +31 (0) 75 63 54 00 3
Norway
Industrielementer AS
Postboks 43
1556 Son
Tel. +47 (0) 64 95 81 32
Fax +47 (0) 64 98 29 29
www.industrielementer.no
[email protected]
siv. ing. J.F. Knudtzen A/S
Billingstadsletta 97
1396 Billingstad
Tel. +47 (0) 66 98 33 50
Fax +47 (0) 66 98 09 55
www.jfk.no
[email protected]
South Africa
Magnete Service Binder
P.O. Box 44051
2104 Linden
Tel. +27 (0) 11 46 2-32 08
Fax +27 (0) 11 46 2-33 04
[email protected]
www.kendrionmt.com
Spain, Portugal
Binder Magnete Iberica S.L.
Apartado de Correos 116
Costa Zefir 99
43892 Miami-Playa (Tarragona)
Tel. +34 9 77 17 27 07
+34 9 77 81 04 29
Fax +34 9 77 17 01 82
www.binder-es.com
[email protected]
Sweden
Industrikomponenter AB
Industrivägen 12
17148 Solna
Tel. +46 (0) 8 51 48 44 00
Fax +46 (0) 8 51 48 44 01
www.inkom.se
[email protected]
Uno Gunnarsson / Höör AB
Box 64
24322 Höör
Tel. +46 (0) 4 13 24 54 0
Fax +46 (0) 4 13 23 18 3
Moeller Electric AB
Granitvägen 2
55303 Jönköping
Tel.
+46 (0) 86 32 30 00
Fax
+46 (0) 86 32 32 99
Switzerland
Kendrion Binder Magnet AG
Albisstrasse 26
8915 Hausen a/A
Tel. +41 (0) 17 64 80 60
Fax +41 (0) 17 64 80 69
www.kendrion.ch
[email protected]
United Kingdom
Kendrion Binder Magnete
(U.K.) Ltd.
Huddersfield Road, Low Moor
Bradford, West Yorkshire,
BD12 0TQ
Tel. +44 (0) 12 74 60 11 11
Fax +44 (0) 12 74 69 10 93
www.kendrion-binder.co.uk
[email protected]
USA
Gradframe Inc.
950 E. Baldwin Road
Palatine IL 60074
Tel. +01 847 991 1788
Fax +01 847 991 1788
[email protected]
This publication is for information
purposes only and should not be
regarded as a binding presentation of
the products, unless we expressly
confirm otherwise.
We reserve the right to make changes
to the specification, form, price and
availability of the products described
herein at any time without prior notice.
Each product may be used only for its
intended purpose.
We reserve to make changes to the
product design.