* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download Input / Output Control Module - GAI
Electric power system wikipedia , lookup
Electrical substation wikipedia , lookup
Power inverter wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Audio power wikipedia , lookup
Voltage optimisation wikipedia , lookup
Power engineering wikipedia , lookup
Pulse-width modulation wikipedia , lookup
Distributed control system wikipedia , lookup
Alternating current wikipedia , lookup
History of electric power transmission wikipedia , lookup
Buck converter wikipedia , lookup
Control theory wikipedia , lookup
Solar micro-inverter wikipedia , lookup
Amtrak's 25 Hz traction power system wikipedia , lookup
Power over Ethernet wikipedia , lookup
Opto-isolator wikipedia , lookup
Immunity-aware programming wikipedia , lookup
Resilient control systems wikipedia , lookup
Mains electricity wikipedia , lookup
Power electronics wikipedia , lookup
Distribution management system wikipedia , lookup
Control system wikipedia , lookup
Input / Output Control Module Model 12584-001 GAI-TRONICS® Features • • • • • Provides up to 32 Dry Contact Inputs Provides up to 32 digital outputs Supports Serial Data Interface RS232 and RS485 Compatible with Audio Messenger Interface and Zone Interface Module Customer-Configurable via switch settings or via GAI-Tronics® Controller Software Benefits • • • • • • Ease of Use and system flexibility Creates a stand-alone SCADA system Mates with GAI-Tronics® Emergency Notification products and systems Flexibility of Integration into systems and data transmission schemes Point-to-point or multi-point Multiple installations schemes; wire, fiber, ethernet, or wireless The Model 12584-001 I/O Control Module provides 32 dry contact inputs and 32 digital outputs. The control module requires a 12 or 24 volt dc power supply. For communication and control by other systems, the control module is equipped with two types of serial data interfaces (RS232 and RS485). The I/O Control Module supports both RS485 and RS232 data connections. A jumper is provided to select either RS485 or RS232 data communications. The use of either the RS485 or RS232 is dependent on the application. For RS485, the data connections are made directly to the terminal blocks. For RS232, a standard male DB-9 connector is provided. A null modem cable should be used when connecting to the controlling device. The Digital Output connectors each provide 16 digital (common ground) output connections designed to drive externally-mounted relays or other indicating circuits. Each output can sink up to 150 mA of the current. External circuitry (relays, indicators, etc.) must be powered from an external power supply of the same voltage used to power the I/O Control Module (12 to 24 V dc). The Digital Input Connections each provide connections for eight contact closure inputs. Switches or relay contact closures are used to activate the inputs. The input contacts may be any combination of momentary (pulsed) switches and maintained (latched) switches. They can be either N.O. or N.C. dry contacts rated at 5 mA minimum. The I/O Control Module requires a dc power supply. The dc power supply voltage must be between 12 and 24 V dc. Input / Output Control Module Model 12584-001 GAI-TRONICS® Specifications Power Supply Requirements Connection to a 12 to 24 V dc (UL listed) Class 2 power source . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 600 mA minimum Power consumed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 watts maximum Auxiliary outputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Sink 150 mA maximum, per output to circuit common and pulled up to the power input voltage Power Supply Requirements Enclosure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Steel body and cover; black fine-textured paint finish Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Wall or Shelf Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7.50 W× 5.625 D × 1.02 H inches (191 × 143 × 26 mm) Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 lbs. (0.902 kg) Environmental Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +32 °F to +122 °F (0 °C to +50 °C) ® GAI-TRONICS USA UK Italy Malaysia Australia Toll Free: 1 (800) 492-1212 Tel: (610) 777-1374 Fax: (610) 796-5954 www.gai-tronics.com Tel: +44 (0)1283 500500 Fax: +44 (0)1283 500400 www.gai-tronics.co.uk Tel: +39 02 48601460 Fax: +39 02 93663110 www.gai-tronics.it Tel: +60-3-8945-4035 / 8945-7348 Fax: +60-3-8945-4675 www.gai-tronics.com Tel: 011-61-28-851-5000 Fax: 011-61-29-899-2490 www.austdac.com.au Quality Management System Certified by DNV - ISO 9001:2008. The policy of GAI-Tronics is one of continuous improvement; therefore the company reserves the right to change specifications without notice. Pub. 060101