* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download Catalog
Three-phase electric power wikipedia , lookup
Audio power wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Electrification wikipedia , lookup
Stray voltage wikipedia , lookup
Resilient control systems wikipedia , lookup
Distributed control system wikipedia , lookup
Electric power system wikipedia , lookup
Pulse-width modulation wikipedia , lookup
Amtrak's 25 Hz traction power system wikipedia , lookup
Electrical substation wikipedia , lookup
Oscilloscope types wikipedia , lookup
Buck converter wikipedia , lookup
Immunity-aware programming wikipedia , lookup
Control system wikipedia , lookup
History of electric power transmission wikipedia , lookup
Power engineering wikipedia , lookup
Voltage optimisation wikipedia , lookup
Power electronics wikipedia , lookup
Alternating current wikipedia , lookup
Power supply wikipedia , lookup
Power over Ethernet wikipedia , lookup
Switched-mode power supply wikipedia , lookup
1 Dear colleagues and partners! Thank you for your attention to the products and solutions of Engineering Center "Energoservis". We are pleased to present our new catalog. In 2015, we release upgraded devices with improved performance, enhanced functionality and renewed design. Our flagship product is ENIP-2 which opens new possibilities for substation automation and power plants. In 2014, ENIP2 IEC61850 complience was confirmed by numerous tests. Today, ENIP-2 is the leader among multi-functional transducers in Russia. ENIP-2 provides high accuracy measurements, and integrates easily into automated systems infrastructure. ENMV digital input/output device range welcomes a new modification that supports IEC 61850. Remote Terminal Units ENCS-3m are ready to operate in the remote control systems at the facilities of any level. We continue producing devices for Wide Area Measurement System (WAMS): phasor measurement unit (PMU) ENIP-2, phasor data concentrator ES PDC, analog input module ENMV-3 and diagnostic display panel ENMI-6. We focus our attention on the quality of our products, improving the production system, and creating our new laboratory for testing and research. Our products are certified to comply with the standards of electrical safety and electromagnetic compatibility. Each product passes interoperability tests, climatic and mechanical tests. Each manufactured device undergoes a full cycle of acceptance tests. The advantages of our products are based on scientific research and new developments, the continuous search for new ideas and focus on customer satisfaction. Success of our customers inspires us to new developments. 2 ENIP-2 multifunctional power meters 16ENMI display panels 20ENMV i/o modules 28 ENCS-2 30 ENCS-3M time sync module remote terminal units 34ENCM communication modules 38 ОPTIONS AND ACCESSORIES ENIP-2 ENIP-2 Family multifunctional power meters Flagship Line The series of ENIP-2 in plastic case housing for DIN-rail mounting includes four models that differ in cost and capabilities. The simplest meter comes with a single RS-485 interface to suit any low-cost solution. The most complex model comes with 2 RS-485 interfaces, 2 Ethernet ports, up to 8 digital inputs and 3 digital outputs. Additional communication interfaces may as well serve for pairing with external modules for extended digital I/O functionality and display. Compact Design The series of models in compact metal body is designed for use in 6–20 kV switchgear cells where only small devices can be installed. ENIP-2 is a series of multifunctional power meters for three-phase electrical networks. ENIP-2 is designed for metering and telecontrol in automated systems of electric power substations. ENIP-2 also can serve as a basic bay control unit. The success of ENIP-2 is the result of the following three factors: rich functionality, high quality, and reasonable price. These three factors combined together with supply terms provide great opportunities for electric power system engineers, designers and maintenance personnel. Outlined features increase observability of electric power systems, providing Smart Grids with state of the art automated process control systems. High quality of measurements is provided by the application of specific processing algorithms. Reliable and fast data transmission from remote facilities is implemented using redundant interfaces and contemporary communication protocols. ENIP-2 is connected to three- or four-wire network directly or through current and voltage transformers. ENIP-2 may be installed in protection compartments of enclosed switchgear, in panels and cabinets. Due to wide operating temperature range, ENIP-2 can be applied in unattended and non-heated facilities. ENMI display panels are designed to be a human interface of ENIP-2. ENMI is easily connected to ENIP-2 with RJ45 patch cord. Modbus RTU, Modbus TCP, IEC 60870-5-101, IEC 608705-104 and IEC 61850. Equipped with four to eight digital inputs (depending on the chosen model) ENIP-2 is capable of processing the state of several switchgears and protection relays. Single ENIP-2 can be sufficiently used as a bay controller unit. Apart from measurements, it provides remote signaling with digital inputs and switchgear control with electromagnetic relay outputs. This series has redundant data interfaces and power inputs to provide increased reliability. To control switchgears any model of ENIP-2 can be paired with an external ENMV module, or a model with three built-in digital outputs can be used. ENIP-2 provides ease of both protocol configuration and firmware upgrade via USB-port, which can be used for measurement data transfer as well. No driver installation is needed. Connected to USB, ENIP-2 operates without auxiliary power supply. ENIP-2 can be configured from a PC with included software or built-in web-console. Phasor Measurement Unit This is a series of phasor measurement units (PMUs) that are used for building wide area monitoring systems (WAMS). WAMS open new perspectives for: •• monitoring power grid state ENIP-2 is a large family of devices that can be divided into three branches: •• detecting and preventing further grid instabilities •• a series of power meters in plastic housing for DINRail mounting •• analysing system failures. •• a series of power meters in compact metal body •• a series of phasor measurement units in plastic housing combined with a color LCD display for mounting on panels or cabinets. •• verifying power grid model Time sync, which is critical for PMU devices, is provided by the global positioning systems. ENIP-2 uses a built-in GPS-receiver, or is synchronized by an external ENCS-2 module. ENIP-2 supports a range of communication protocols: 2 3 Flagship Line → minimal ENIP-2 measures the full set of three-phase electrical network parameters. Single RS-485 interface is used for data transfer. Flagship Line → basic This model is aimed for use at small substations and distribution points. This model is equipped with 4 or 8 digital inputs, and 3 or no digital outputs. For digital inputs, both wet and dry contacts are supported. Dry contacts are powered by built-in 24 V DC supply. Digital outputs are based on solid state relays. RS-485 interfaces operate independently. RS-485-2 may be used to connect an ENMI display panel and up to 4 ENMV-1 I/O modules. Measurements RMS and first harmonic values of: Power quality: •• voltages (phase, line-to-line and average) •• voltage sequences •• currents (phase and average) •• voltage unbalance and distortion •• power (active, reactive and apparent: phase and total) •• current sequences •• And also: •• current unbalance and distortion •• frequency •• THD •• power factor (phase and average) ENIP-2 uses 50 ms sliding window measurement calculation method. The values are updated every 20 ms. •• active and reactive energy in both forward and reverse directions. Digital inputs and outputs Dry contacts 24 V DC power supply RS-485-2 two RJ45 sockets are wired in parallel. ENMI panel is connected with a single patch cord to the right socket which also serves as power supply. The left socket is a regular RS-485 (Modbus RTU, IEC 60870-5-101). It may be used to connect other external modules, such as ENMV. For monitoring purposes ENIP-2 has a set of configurable thresholds. USB port RS-485-1 (Modbus RTU, IEC 60870-5-101) Flagship Line → extended Power supply input This model is equipped with 3 RS-485 interfaces and 1 Ethernet 100Base-T. ENIP-2 with an Ethernet 100Base-T port can be integrated into IEC 61850 digital substation infrastructure. ENIP-2 acts as MMS server and is capable of publishing and subscribing to GOOSE messages. Combined with logic expressions evaluation, it allows ENIP-2 to be used for circuit breaker interlocking. Current and voltage inputs RS-485-3 (Modbus RTU, IEC 60870-5-101) Ethernet 100Base-T, (IEC 61850, IEC 60870-5-104, Modbus TCP, SNTP, SNMP, NETBIOS, pass-through mode to any RS-485, and web-console for protocol configuration) 4 5 Specification Flagship Line → maximum This model comes with two Ethernet ports and a built-in switch that supports RSTP (Rapid Spanning Tree Protocol , IEEE 802.1D) and PRP (Parallel Redundancy Protocol, IEC 62439-3). 100Base-T or 100Base-FX (LC multi-mode) Ethernet implementations are available. Measurements rated current: 1 or 5 А, rated voltage: 57,7 (100) or 220 (380) V Voltage (input range: 20–150 %) ±0,2 % Current (input range: 1–200 %) ±0,2 % Power (active/reactive/apparent) ±0,5 % Frequency ±10 mHz Power quality U0, U1, U2, K2U, KU, I0, I1, I2, K2I, KI, THD Digital inputs/outputs 2 x Ethernet 100Base-T, (IEC 61850, IEC 60870-5-104, Modbus TCP, SNTP, SNMP, NETBIOS, pass-through mode to any RS-485, and web-console for protocol configuration) Inputs 0, 4 or 8 (dry or wet contact) Outputs 0 or 3 (solid state relay, 300 V DC / 250 V AC, 100 mA) Optional modules display ENMI digital inputs/outputs ENMV (up to 4 digital inputs and up to 12 electromagnetic relay outputs) Communication RS-485 1–3 ports — Modbus RTU, IEC 60870-5-101 (600–115200 bit/sec) Ethernet 100Base-T Ethernet 100Base-FX (LC sockets, fiber multi-mode) 1 or 2 ports — IEC 61850, IEC 60870-5-104, Modbus TCP, SNTP, SNMP, NETBIOS, pass-through mode to any RS-485, web-console for protocol configuration 2 port model comes with built-in switch that supports RTSP, PRP. Real time clock Maximum error 0,5 msec Time synchronization Ethernet (IEC 60870-5-104 C_CS_NA_1, SNTP) or RS-485 (IEC 60870-5-101 C_CS_NA_1) Event logging status of digital input and outputs, diagnostic messages; software update, configuration change, power supply events Power supply 2 x Ethernet 100Base-FX, (IEC 61850, IEC 60870-5-104, Modbus TCP, SNTP, SNMP, NETBIOS, pass-through mode to any RS-485, and web-console for protocol configuration) 6 Input voltage 18–36 V DC or universal 120–370 V DC / 100–265 V AC (45–55 Hz) Power consumption 4 VA (10 VA with ENMI powering from 24V= Port 2) Operating conditions and design Operating temperature from −40 to +70 °C Design and mounting plastic housing 75х100х110 mm, DIN-rail mounting IP40 7 Ordering Information Rated current 1–1А 5–5А Compact Design → basic ENIP-2 in metal housing combines compact design with extended functionality. Power supply voltage 220 – 100–265 V AC (45–55 Hz) or 120–370 V DC 24 – 18–36 V DC Measured parameters, metrological characteristics and processing speed are identical to those of standard ENIP-2 modification (see page 7). ENIP-2-4 X / X - X - X - X1 Rated voltage 100 – 57,7 V (L-L 100 V) 380 – 220 V (L-L 380 V) Mounting brackets for installation in enclosed switchgears of different type are available. Interfaces and digital inputs/outputs A1E0-01 – 1 x RS-485 A2E0-11 – 2 x RS-485, 4 digital inputs, 3 digital outputs A2E0-21 – 2 x RS-485, 8 digital inputs A3E4-21 – 3 x RS-485, 1 x Ethernet 100Base-T, 8 digital inputs A2E4x2-21 – 2 x RS-485, 2 x Ethernet 100Base-T, 8 digital inputs A2E4x2FX-21 – 2 x RS-485, 2 x Ethernet 100Base-FX, 8 digital inputs (wet contact) Distinguishing features: •• 3 additional voltage inputs for the detection of the presence of voltage on voltage divider insulators in 6–20 kV networks •• 3 built-in electromagnetic relays •• Two power supply inputs •• Two independent RS-485 interfaces 2 x RS-485, 2 x power supply inputs USB port 3 additional voltage inputs Voltage inputs Status LEDs (interfaces, I/O) 3 built-in electromagnetic relay outputs 12 digital inputs (wet contact) Current inputs Оptions and accessories Compact Design → minimal ES61850.enip IEC 61850-8-1 support for ENIP-2 (applies to А3Е4-21, А2Е4x2-21, А2Е4x2FX-21 only), MMS server (up to 4 clients), publish 8 GOOSE messages, subscribe to 10 GOOSE messages. Conformance to LVS EN 61010-1:2011 (EN 61010-1:2010), EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-11. 8 This model is one phase, current only (only additional voltages are measured). Digital inputs and outputs are the same as of basic compact model. This model will suit any a low-cost solution. Conformance to EU RoHS directive (№2002/95/EC). 9 Specifications Measurements Phasor measurement unit → PMU ENIP-2 family includes a series of devices with Phasor Measurement Unit (PMU) functionality. See page 7 Input/output Digital inputs 12 (dry or wet contact) Digital outputs 3 outputs (cascade of electromagnetic relays and high power solid state relays); switching capacity; 250 V, 6A DC / AC Analog inputs 3 additional voltage inputs (1–300 V AC) Optional modules see page 7 Communications 2 х RS-485 (600–115200 bit/sec) Modbus RTU, IEC 60870-5-101 PMUs are used in automated control systems of substations and power plants, being the key component of Wide Area Measurement Systems (WAMS). WAMS are used to monitor power grids, detect and prevent power grid instabilities. Signal processing algorithms of ENIP-2 are implemented in accordance with IEEE C37.118.1. The accuracy of synchrophasor measurements is not influenced by electromagnetic transients free components and higher harmonics. Time sync, which is critical for PMU devices, is provided by the global positioning systems. ENIP-2 uses a built-in GPS-receiver, or is synchronized by an external ENCS-2 module. Several devices can be synchronized by a single ENCS-2 or ENIP-2 with GPS-receiver. ENIP-2 PMU can be installed on panels or in cabinets. Typically it is installed in special cabinets, along with other components of WAMS. Real time clock Accuracy 0,5 msec Time synchronization RS-485, IEC 60870-5-101 C_CS_NA_1 (103) Event logging status of digital input and outputs, diagnostic messages; software update, configuration changing, power supply events Uninterruptible power supply and redundant communication channels are critical for WAMS stability. ENIP-2 PMU has 5 digital inputs and 3 interfaces: Ethernet 100Base-T, RS-485 (for IRIG-A synchronization), and RS-232 (service port). The following features are optional: •• built-in GPS-receiver •• TFT color touch screen display to view the measurement values as diagrams (synchrophasor or oscilloscope), or in tables ENIP-2 is one the most compact PMU devices ever. It is easy to install and connect in any environment. Current and voltage inputs are protected from unauthorized access by a cover that can be sealed. Data link protocols IEEE C37.118.2 and IEC 60870-5104 are supported. Datarate from 50 to 200 frames per second is supported. Both IEEE C37.118.1 measurement classes P and M are supported, and are cofigurable by end user. ENIP-2 with IEC 61850-9-2LE process bus input support can be used in digital substations. Power supply Input voltage / Power consumption 18–36 V DC / 5 VA Operating conditions and design Operating temperature Design and mounting from −40 to +70 °C 130х100х58 mm metal housing, IP40 DIN-rail mounting or special bracket (see Options and Accessories) Ordering Information Connection type 1 — one phase (minimal) 4 — three phase (basic) Rated current 1—1А 5—5А Rated voltage 100 — 57,7 V (L-L 100 V) 380 — 220 V (L-L 380 V) 0 — no voltage inputs ENIP-2-X X / X-24-А2Е0-32 Оptions and accessories DIN-BR Built-in GPS-receiver 4,3" TFT color touch screen display, 480х272 Ethernet 100Base-T RS-485 (IRIG-A) combined with RS-232 (service port) Power supply input Bracket for ENIP-2-..-32 (metal housing) for mounting on DIN-rail. Aluminum alloy 5 digital inputs RM6-BR Current and voltage inputs Bracket for ENIP-2-...-32. Stainless steel 1,5 mm 10 11 Specifications Measurements Phasor measurement unit → WAMS PMU ENIP-2 is ideal for creating Wide Area Measurement Systems. We provide all the necessary software and hardware to create WAMS on substations and power plants. See page 7 Digital inputs/outputs Inputs The WAMS equipment is located usually in one or more rack cabinet. We also produce special versions cabinets on request, which are made according to customer requirements. 5 (dry contact) Communications WAMS lets solved a number of problems: •• providing measurement synchrophasors in real time; •• global monitoring of transmission system conditions over large areas; •• detecting and preventing further grid instabilities. •• verifying model of power grid; •• emergency record archives and emergency events, visualization of dynamic characteristics of the system, analysis of power grid failures. RS-485 time sync using IRIG-A (with ENCS-2 time sync module) or transmitting IRIG-A to another PMU if PMU have built-in GPSreceiver RS-232 (19200 bit/sec) service port to update firmware WAMS based on equipment produced Engineering centre "Energoservice" include: Ethernet 100Base-T IEC 60870-5-104 (up to 4 clients), IEEE C37.118.2-2011 (up to 4 clients) •• ENIP-2 (PMU); •• ES PDC — phasor data concentrator; Real time clock Accuracy 1 µs if clock synced •• ENCS-2 — time sync module (IRIG-A time code sequence); If no time sync Within 10 minutes after the loss of time synchronization error in time is still 1 µs •• ENMV-3 — analog input modules for controlling the parameters of generator excitation (for power plants); Source of time sync ENCS-2 time sync modul, RS-485 (IRIG-A) •• ENMI-6 — diagnostic subsystem; •• UPS — uninterruptible power supply subsystem; Options •• communications equipment (switches, routers). Built-in GPS-receiver to receiving time and coordinates Built-in display 4,3’’ TFT color touch screen , 480х272 Power supply Voltage of power supply 18–36 V DC or universal 120–370 V DC / 100–265 V AC (45–55 Hz) Power consumption 10 VA PMU ENIP-2 Operating conditions and design Operating temperature Design and mounting from −40 to +70 °C or –10...+70°С if equiped with TFT display 160х165х83 mm plastic housing, panel or cabinet mounting, IP40 Terminal blocks of current and voltage ENCS-2 - time sync module Ordering Information Rated current 1–1А 5–5А ENMI-6 — display panel for diagnostic messages KVM with с 17’’ LCD monitor Power supply voltage 220 – 100–265 V AC (45–55 Hz) or 120–370 V DC 24 – 18–36 V DC ES PDC — phasor data concentrator UPS ENIP-2 - 4X / X - X - A1E4 - XX Rated voltage 100 – 57,7 V (L-L 100 V) - connection to potential transformer 380 – 220 V (L-L 380 V) - direct connection to power line 12 Options 03 – 1 x RS-485, 1 x Ethernet 100Base-T, 5 digital inputs, PMU functions 13 – ... + TFT color touch screen 23 – ... + built-in GPS/GLONASS-receiver 13 Specifications Ordering Information Measurements (PMU) Number of PMU ENIP-2 1…6 in one cabinet: maximum 40. Analog input PMU number of PMU ENIP-2 number of ENMV-3 in one enclosure Controlling the parameters of generator excitation Analog input modules ENMV-3 ENMV-3 are mounted in WAMS cabinets or on panels near the primary sensors Digital inputs 5 inputs "dry contacts" to monitoring state of the measuring circuits (cover of terminal blocks), state of cabinet door and other digital signals Phasor data concentrator Type ES-PDC, up to 40 inputs (PMU), up to 4 Outputs, 240/360Gb Number of PDC 1 or 2 (redundant) PDC type C – 1x ES PDC CR – 2 x ES PDC 0 – w/o PDC WAMS - X X - X - X .. X - X Additional requirments D – diagnostic subsystem (ENMI-6) FXS... – number of fiber optic ports (single-mode) FXM... – number of fiber optic ports (multi-mode) T100... – number of Ethernet 100Base-T ports T1000... – number of Ethernet 1000Base-T ports Type of power supply system 1 – 1 input + UPS 2 – 2 inputs + UPS 0 – 1 input, w/o UPS Time sync subsystem Time sync module ENCS-2 GPS-receiver with IRIG-A time code sequence Diagnostic subsystem Type Display panel ENMI-6 (4,3" TFT color touch screen, 480x272) with alarm digital output. Monitored equipments PMU, PDC, time sync subsystem, UPS, network Power supply Type of power supply system up to 2 power supply inputs, UPS with battery support (3000 VA) Voltage of power supply 160...286 V AC Power consumption 500 VA Operating conditions and design Operating temperature from 0 to +55 °C Housing Enclosure cabinet, sheet steel, glass door, 2200х800х800 mm Оptions and accessories GPS-B3.15, GPS-B3.45 GPS outdoor antenna (feeder long 15 m or 45 m, SMA connector) GPS-BR-mini Compact bracket for mounting GPS antenna. Stainless steel 1,5 mm GPS-BR-300, GPS-BR-500, GPS-BR-1000 Steel bracket for mounting GPS antenna, 300/500/1000 mm 14 15 ENMI Review of versions ENMI-3 LED display panels for ENIP-2 display panels 7-digit LED (3 lines of 4 digits), digit height 20mm Additional indicators, indicating the current display mode Brightness adjustment button Buttons for selecting the display mode ENMI displays values of main measured and calculated parameters received from ENIP-2. Also EMNI may used for displaying service data from other devices and systems. Display panel ENMI is designed for ENIP-2 to display of measured values. Usage of ENMI as switchboard instruments provides identity of measurements, transmitted to SCADA and readings on the devices at the facilities. ENMI-4 are based on 4", FSTN LCD displays and have extended functionality, allowing for display of different values in specific form: •• digital indicator; •• bar graph; •• diagram of switchgear device with displaying of basic nets parameters). ENMI produced in different version: LEDs, TFT color touch screen, monochrome LCD. Depending from version they have special functionality. The color touch screen ENMI-5 has a lot of information display forms and may looks even like pointer-type instrument. For example, ENMI-3 based on LEDs have a long life and extended temperature range. Its main purpose is to display measured values received from ENIP-2. Data from one ENIP-2 may be displayed on several ENMI or one ENMI can display data from several ENIP-2. It have big and bright LED digital display segments and allow well-read values. ENMI-3 displays values of main parameters of three-phase electrical network . ENIP-2 and ENMI connected via standard UTP patch cord. Patch cord used to power ENMI from ENIP-2 (24 V DC) and for connecting them via RS-485. Devices may mounted separately or together. When ENIP-2 constructively associated with ENMI it looks like single device. We call it "transformer". This flexibility allow to mount ENIP-2 differently: inside relay cell of high-voltage switchgear and on panels in substation control. ENMI-6 has a Ethernet port, which allows the use it for displaying data in automated systems of "digital substations". Another software version lets use ENMI-6 for diagnose WAMS equipment. ENMI may be mounted on panels in hole 110*110 mm. Also ENMI may be combined constructively with ENIP-2 and looks like one device. ENMI-4 4", FSTN monochrome LCD displays for ENIP-2 Main form showing schematic diagram of the high-voltage switchgear with active elements and displaying values of the main parameters. A large set of display modes: Function Data display Generation of alarms •• connects to ENIP-2 and displays values of measured and calculated parameters, digital inputs status; ENMI is capable of supervising the limits. When one of the parameters violates the preset limits, there is a specific indication and display visualizes this parameter on the screen. •• independent display unit for viewing equipment status, supervision of software and hardware units. Control Buttons for selecting the display mode and menus ENMI-5 provides sending control command to ENIP-2. 16 17 Specifications ENMI-5 4.3" TFT LCD touch screen displays for ENIP-2 ENMI-3 ENMI-5 serve to display measured values of ENIP-2 on several screens: Type of display •• as pointer-type instrument; LED 7-digit LED (3 lines of 4 digits), digit height 20x11 mm •• set of digital indicators; •• set of graphs; •• voltage and current phasors diagram. ENMI-4 ENMI-5 4", FSTN monochrome 240х128 pix ENMI-6 4.3", TFT touch screen 480х272 pix Communications Interface RS-485 (Modbus RTU) or Ethernet (IEC 61850, SNTP, SNMP) RS-485 (Modbus RTU) A large set of display modes: Power supply Input voltage 18–36 V DC Power consumption 5 VA 3 VA Operating conditions and design Operating temperature from −40 to +55 °C from −10 to +55 °C from 0 to +55 °C Design and mounting 120х120х49 mm plastic housing, panel or cabinet mounting, IP30 (111х111 mm square hole), ENMI constructively combines with ENIP-2. ENMI-6 4.3" TFT LCD touch screen multipurpose displays ENMI-6, depending on the firmware can be used in the following applications: •• Panel for displaying diagnostic information about WAMS equipment, it displays equipment status and has alarm digital output for outer systems; •• Display panel for substation control systems using IEC 61850: displaying values received over MMS or GOOSE. Ordering Information ENMI - X - 24 - 2 Type of display 3 – LED for ENIP-2 4 – LCD FSTN monochrome for ENIP-2 5 – LCD TFT touch screen for ENIP-2 6 – LCD TFT touch screen multipurpose display Conformance to LVS EN 61010-1:2011 (EN 61010-1:2010), EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-11. 18 Conformance to EU RoHS directive (№2002/95/EC). 19 ENMV Review of version Digital inputs and control ENMV-1-24/0 i/o modules Digital inputs of 24 "wet contacts" or "dry contacts". "Dry contacts" are powered by internal power supply of ENMV (24 V DC). 2 х RS-485 (Modbus RTU, IEC 60870-5-101) Power supply inputs USB port Ethernet 100Base-T (IEC 60870-5-104, Modbus TCP, IEC 61850) LEDs input statuses Terminal blocks of inputs ENMV is the series of i/o modules intended for use in the remote terminal units and automated systems at substations and power plants. ENMV, ENIP-2 and ENCS-3m together allow you to create distributed systems of remote control of various power facilities. Main purpose of ENMV is input and output digital and analog signals and data transfer via galvanically isolated interfaces RS-485 and Ethernet. ENMV may transfer data directly or through ENIP-2, ENCS-3m or other automation equipment. The series includes: •• ENMV-1 — i/o modules with 4, 12 or 24 digital inputs, 6 or 22 digital outputs based on solid state relay or 3 relay outputs; •• ENMV-2 — i/o modules with 4 digital inputs, 3 relay outputs and 4 analog inputs (3 voltages and 1 current); ENMV-1 and ENMV-2 equipped with relay outputs allow control switchgear. ENMV-2 — is designed for use in electric distribution networks 6-20 kV. ENMV-2 provides remote control, digital inputs, analog inputs and allows to control the voltage on the three phases (from the capacitive divider base insulators cable lines). ENMV real time clock is synchronized by ENCS-2 or by other time sync sources. ENMV has events log of i/o statuses. Each record of event log is marked with time stamp with 1 ms resolution. All data from ENMV are transmitting to the upper level via RS-485 or Ethernet. ENMV-1-0/22 Digital outputs for control switchgear or other equipment. ENMV-1-0/22 is designed to output the control commands via the 20 digital outputs (DO, low-voltage solid-state relays) and 2-speed output (TRIP, solid state relays for power applications). 2 х RS-485 (Modbus RTU, IEC 60870-5-101) Power supply inputs USB port Ethernet 100Base-T (IEC 60870-5-104, Modbus TCP, IEC 61850) LEDs output statuses •• ENMV-3 — analog input modules with 2 inputs. ENMV-3 is designed for WAMS to control the parameters of generator excitation (for power plants); •• ENMV-1W — input modules for interfacing with temperature sensors on the bus 1-Wire. Terminal blocks of outputs •• 20 21 Digital inputs and control i/o module for distribution 6-20 kV grids ENMV-1-0/3R ENMV-2-4/3R is the optional module for ENIP-2 and used for monitoring and control in 6-20 kV grids. ENMV-2-4/3R is connected to the ENIP-2 via RS-485-2 port. ENIP-2 transfers the parameters measured and controlled ENMV-2, together with the rest of the volume of data being processed. Digital outputs for control switchgear or other equipment. ENMV-1-0/3R independently or under the control of ENIP-2 provides remote control command execution via the built-in electromagnetic relays. Digital input ENMV-2-4/3R complements ENIP-2 with 4 digital inputs for "wet contact" or "dry contact" signals ("dry contacts" are powered by internal power supply of 24 V DC). Power supply inputs LEDs statuses: relay outputs, power, interface RS-485 (1 port on double RJ-45) (Modbus RTU, IEC 60870-101) Control ENIP-2 can control the switchgear via 3 built-in electromagnetic relays of ENMV-2-4/3R. Monitoring ENMV-2-4/3R has current and voltage inputs to control zero sequence current (3I0) and voltage from the capacitive dividers connected to the 6-20 kV. 3 relay outputs 3 electromagnetic relay outputs ENMV-1-4/3R 4 digital inputs Power supply inputs Digital inputs and outputs for control switchgear or other equipment. ENMV-1-4/3R is same ENMV-1-0/3R but added with 4 digital inputs for "wet contact" or "dry contact" signals ("Dry contacts" are powered by internal power supply of 24 V DC). LEDs statuses: relay outputs, voltage inputs RS-485 (Modbus RTU) 4 digital inputs Current and voltage inputs 22 23 Temperature monitoring Analog inputs for WAMS ENMV-1W designed to interfacing a remote control units of substations and non-electrical sensors such as temperature sensors, humidity sensors, security system sensors and so on. The exchange between ENMV-1W and sensors carried on the bus 1-Wire. ENMV-3 has two analog inputs. ENMV-3 can be used for remote control systems and other automated systems when necessary control the parameters of the DC network. Main purpose of ENMV-3 is control of parameters of generator excitation systems at power plants in WAMS applications. ENMV-3 converts the DC voltages (excitation voltage from the shunt and voltage set in the excitation circuit) and transmits the values to ES PDC. Input range signal for each input is specified when ordering. Thus EMNV-3 can be used for other applications. Power supply inputs LEDs statuses: relay outputs, power, interface Power supply inputs USB port USB port RS-485 (1 port on double RJ-45) (Modbus RTU, IEC 60870-101) RS-485 (IRIG-A) Analog inputs 2 х Ethernet 100Base-T 1-wire terminal blocks 2 digital outputs (SSR) By default ENMV-1W is used for temperature monitoring and support up to 30 sensors. The kit ENMV-1W includes two temperature sensors. Additional temperature sensors, as well as a protective screen against rain, wind and solar radiation ordered separately and are presented below. TS-1w — additional temperature sensor 24 TS-SRS — shield for temperature sensor 25 Specifications ENMV-1-24/0 Ordering Information ENMV-1-0/22 ENMV-2-4/3R ENMV-1-0/3R (ENMV-1ENMV-1W 4/3R) i/o module types 1 – digital input and output 1W – interfacing with 1-Wire temperature sensors 2 – i/o module for 6-20 kV grids 3 – analog input ENMV-3 Digital signals Inputs Outputs 24 WC — 4 WC 0 (4 WС) — — — 20 SSR, 2 TRIP 3 EMR (~10 А) 3 EMR (~7 A) 2 SSR — — 0,010...2 А AC; 0,050...10 А AC; 3…300 V AC. Analog signals Inputs — — temperature -55 °C ...+125° C (2 sensors in kit, up to 30 sensors) ±1000 V DC; ±10 V DC; ±200 mV DC; ±75 mV DC; ±20 mA DC; ±5 mA DC. Communications RS-485 (600...115200 bit/sec) 2 х RS-485: Modbus RTU, IEC 60870-5-101 1 х RS-485: Modbus RTU Ethernet 1 х 100Base-T: IEC 60870-5-104, Modbus TCP, IEC 61850 — 1 х RS-485: Modbus RTU, IEC 60870-5-101 — — IRIG-A 2 х 100Base-T: IEEE C37.118.22010 Event logging i/o statuses — — Diagnostic — — Power supply Voltage of power supply 18–36 V DC or universal 120–370 V DC / 100–265 V AC (45–55 Hz) Operating conditions and design Operating temperature Housing Mounting –40... +70°С Plastic, IP40 75х100х110 mm, Plastic, IP40 75х70х110 mm Metal, IP40 109x188x35 mm Power supply voltage 220 – 100–265 V AC (45–55 Hz) or 120–370 V DC 24 – 18–36 V DC ENMV - X - X - X - X i/o set Interfaces sets ENMV-1: 24/0 – 24 digital inputs 0/22 – 22 digital outputs 12/6 – 12 digital inputs / 6 digital outputs 0/3R – 3 relay outputs 4/3R – 4 digital inputs / 3 relay outputs ENMV-1-0/3R, ENMV-1-4/3R: А1 – 1 х RS-485 ENMV-1-12/6: А2Е0 – 2 х RS-485 А3Е4 – 3 х RS-485, 1 х Ethernet 100Base-T ENMV-1W: 0/2 – 1-wire bus, 2 digital outputs ENMV-1-24/0, ENMV-1-0/22: А2Е0 – 2 х RS-485 А2Е4 – 2 х RS-485, 1 х Ethernet 100Base-T ENMV-2: 4/3R – 4 digital inputs / 3 relay outputs, 3 voltage inputs, 1 current input ENMV-2-4/3R: А1 – 1 х RS-485 ENMV-3: X/... – DC voltage input (AI-1): A – ±1000 V B – ±10 V 0 – AI-1 not used .../X – DC voltage or current input (AI-2): B – ±10 V C – ±200 mV D – ±75 mV E – ±20 mA F – ±5 mA 0 – AI-2 not used ENMV-1W: А1 – 1 х RS-485 ENMV-3: А1Е4х2 – 1 х RS-485, 2 х Ethernet 100Base-T 35 mm DIN-rail mounting Designation: WC — "wet contact", DC — "dry contact", SSR — solid state relay (digital outputs — low-voltage electronic solid state switches), TRIP — digital outputs on power electronic solid state switches), EMR — electro-mechanical relay (outputs on electromechanical relays). Оptions and accessories ES61850.enmv IEC 61850-8-1 support for ENMV-1 I/O module TS-1w Temperature sensor for ENMV-1W TS-SRS shield for temperature sensor TS-1w 26 27 ENCS-2 GPS antenna (SMA connector) PPS output (SMA connector) Interfaces time sync module OLED display Control buttons Power supply input Specifications Accuracy ± 500 nsec — Relative timing error of the front of the output pulse of 1 Hz relative to UTC ± 500 nsec — absolute error of synchronization of the front label synchronization IRIG-A relative to UTC 11 nsec — the minimum quantum of time adjustment ± 0,4 sec/day — absolute timing errors in the absence of satellites Accuracy time synchronization computer is up to 0.5 sec and deteriorating due to delay execution OS API Reliability MTLB / Срок службы An important part of any automated control system is a time sync system. Time synchronisation is needed for any devices, servers and user workstations. The most significant is the exact timing in remote control systems: any event or value must have a time stamp. Precision time synchronizing is main factor in WAMS applications. To get better accuracy of time sync may use global navigation systems (GPS, GLONASS). We produce ENCS-2 — device for time sync special for using in remote control systems. In 2014 we have released upgraded hardware platform to improve usability and of ENCS-2. ENCS-2 may be set up to send commands protocol IEC 60870-5-101 C_CS_NA_1 (103) to synchronize several RTU or transducers. ENCS-2 has a bright OLED display, control buttons on the front panel and interfaces that provide a variety of options for sending time sync signals. To use ENCS-2 is needed install it on DIN-rail, connect GPS antenna, switch on power and configure settings of module. To get best receiving of satellite signals, recommend to install GPS antenna outside on the south side of the building. ENCS-2 receives GPS signals to synchronize remote terminal units, transducers, servers using standard protocols (NMEA 0183, SNTP). •• Time synchronization in remote control units according to IEC 60870-5-101; •• Time synchronization on servers, workstations, automated systems by using protocols NMEA 0183, SNTP; 28 Operating conditions and design Interfaces RS-232-1, RS-485-1: NMEA 0183, IEC 60870-5-101; RS-232-2: NMEA 0183; RS-485-2: IRIG-A; Ethernet 100Base-T: SNTP. Frequency of synchronization According to IEC 60870-5-101 C_CS_NA_1 (103) from 1 minute to 99 days in increments of 1 min, IRIG-A — 100 msec, SNTP — by client request Voltage of power supply 18–36 V DC or universal 120–370 V DC / 100–265 V AC (45–55 Hz), 5 VA Operating temperature from −40 to +70 °C Housing/mounting plastic, 83х100х110 mm, IP40 / 35 mm DIN-rail mounting Ordering Information ENCS - 2 - X . 1 . 1 Function •• receiving of the signals of the navigation satellite systems, the sync time of the internal clock; more than 35000 hours / more than 15 years Power supply voltage 1 — 100–265 V AC (45–55 Hz) or 120–370 V DC 2 — 18–36 V DC •• time synchronization of the internal clock of ENIP-2; •• generate a PPS signal for time correction.. Оptions and accessories GPS-B3.15, GPS-B3.45 GPS outdoor antenna (feeder length 15 m or 45 m, SMA connector) GPS-BR-mini Compact bracket for mounting GPS antenna. Stainless steel 1,5 mm GPS-BR-300, GPS-BR-500, GPS-BR-1000 Steel bracket for mounting GPS antenna, 300/500/1000 mm 29 ENCS-3m remote terminal units Review of version Base configuration ENCS-3m in base configuration have 6 x RS-485, 4 x RS-232, 2 x Ethernet, 1 x CAN. RTU is mounted on DIN-rail. The front panel has LEDs statuses: ports, power supply, mode status. Front view Interfaces LEDs statuses Power supply input GT option Sometimes there is not accessible channels except GSM — then may use GT option. ENCS-3m - is a reliable software and hardware platform for building remote control systems for substation and power plants. This is proven by a decade of experience operating of previous generation model ENCS-3. Remote terminal unit (RTU) ENCS-3m is designed to create geographically distributed systems: •• at the field level installed devices (ENIP-2, ENB series) which support measurement parameters values, monitoring digital signals and control by digital outputs to switchgears and mechanism; •• all this devices are connected to RTU ENCS-3m via RS-485 lines or local networks; •• RTU ENCS-3m collect, consolidate and distribute necessary data to a higher level of control systems. To control data traffic from field level devices ENCS-3m uses absolute and relative apertures. Timestamps of data are assigned by field devices. ENCS-3m build on 32bit ARM microcontroller and providing continuous operation for remote control systems. To increase reliability system ENCS-3m support 2 redundant modes: warm standby and hot standby. 30 ENCS-3m use hard real-time algorithm, and thus provides high performance and reliability. ENCS-3m polls devices according IEC 60870-5-101. ENCS-3m support up to 10 ports for device polling. ENCS-3m allows setup up to 16 channels to transmit data to upper level using 2 LAN and RS-232/RS485 ports. 2 RTUs ENCS-3m connect through CAN-bus to support warm standby in pair. GT option has built-in GSM (GPRS) module and built-in GPS-receiver. RTU synchronizes his own clock and clocks of polled devices by using built-in GPS-receiver. GT option, rear view GPS antenna (SMA connector) GSM antenna (SMA connector) RS-485 interface, RS-232, Ethernet can be distributed by the user between data collection from field devices and transmission of information to the top level. To communicate with the field devices are preferred protocol IEC 60870-5-101, which provides for the regulation of traffic between the RTU and devices, and allows you to send a data with timestamp directly from the sources of their formation. If you need compact and reliable RTU? Use ENCS-3m. SIM-card slot, USB (service port) 31 Ordering Information Specifications Data amount 8192 measurement values, 4096 digital signals Polled devices Maximum amount 240 Supporting type devices ENIP-2, ENMV series, Modbus RTU devices, IEC 60870-5-101 any device or RTU with supporting IEC 60870-5-101 Version: 648 – 6xRS-485, 4xRS-232, 2xEthernet 100Base-T 648GT – ... + GT option (GPS/GLONASS-receiver, GSM-module) ENCS-3m . X . 0 - X . X Power supply voltage 1 – 100–265 V AC (45–55 Hz) or 120–370 V DC 2 – 18–36 V DC Communications 6 х RS-485 (300–115200 bit/sec) 4 х RS-232 (300–115200 bit/sec) Mounting type 1 – 35 mm DIN-rail mounting, IP40; 2 – IP66, installation in the wall cabinet with accessories. Assigned by the user to poll devices or transmit data to the upper level 2 х Ethernet 100Base-T CAN to support "warm standby" GSM (GPRS) supported when option GT is available USB service port for GT option Amount of channels data transmitting to the upper level Up to 16 channels Asynchronous serial: RS-485/232 (up to 4 channels) TCP / IP - up to 12 channels through one port or two Ethernet ports. GPRS - up to 4 channels Amount port to poll devices Up to 10 ports Asynchronous serial: RS-485/232 (up to 10 ports) UDP — through one or two Ethernet port. Time sync Time synchronization of RTU and polled devices — from GPS-receiver (GT option), — from upper level or by ENCS-2 according IEC 60870-5-101 C_CS_NA_1 (103) Operating conditions and design Voltage of power supply 18–36 V DC or universal 120–370 V DC / 100–265 V AC (45–55 Hz) Power consumption 5 VA Operating temperature from −40 to +70 °C Housing/mounting plastic, 83х100х110 mm, IP40 / 35 mm DIN-rail mounting optional - installation in the wall cabinet with accessories, IP66 Оptions and accessories GSM-3G.3 outdoor GSM antenna on magnetic base (feeder length 3 m) GPS-B3.15, GPS-B3.45 GPS outdoor antenna (feeder length 15 m or 45 m, SMA connector) GPS-BR-mini Compact bracket for mounting GPS antenna. Stainless steel 1,5 mm GPS-BR-300, GPS-BR-500, GPS-BR-1000 Steel bracket for mounting GPS antenna, 300/500/1000 mm 32 33 ENCM Review of version For remote control system ENCM‑3‑X‑А2Т‑402 communication modules Top view Front view Ethernet 100Base-T GPS antenna GSM antenna (SMA connector) 4 digital inputs 1 or 2 analog inputs SIM-card slot Rear view RS-485-2 Power supply input RS-485-1 For AMR systems Communication modules ENCM phelps to collect data from various devices on the network GSM. ENCM series provides an implementation of communication channels for specific purposes: ENCM-1 — to collect data in energy accounting system, ENCM-3 — for remote control systems. The main feature of ENCM-1 is to provide a link from remote object to the Automatic Meter Reading (AMR) systems with minimal maintenance costs. ENCM-1 uses the GSM network and packet data mode GPRS. Also is available CSD mode. In most applications ENCM provides a constant TCP/IP connection between the center and object. ENCM support both connection type — server and client. The connection mode is depending what type of IP addresing in GPRS is used - dynamic or static IP. Also ENKC-1 can synchronize time of meters, using the built-in GPS-receiver. ENCM-3 modules are designed to help control distributed objects energy, transport and industry. ENCM-3 provides transmission of technological information (digital signals and measurements) over the GSM (GPRS) from various devices installed in controlled facilities. It could be multifunctional transducers, relay protection terminal units, meters, I/O modules, etc. ENCM-3 helps to build a remote control system for geographically distributed objects. ENCM‑1‑X‑АЕТ Front view Rear view Ethernet 100Base-T GPS antenna GSM antenna (SMA connector) SIM-card slot Power supply input RS-485-1 Function •• Provide transparent channels via GSM (CSD, GPRS). •• Synchronize devices clock 34 •• Creating remote control system with data transfer according IEC 60870-5-104 via GPRS. •• Supporting remote configuring 35 Ordering Information Specifications ENCM-1 ENCM-3 ENCM series: 1 – for AMR systems 3 – for remote control system Type of channels Wireless Wired GSM: GPRS, CSD Ethernet 100Base-T Interfaces to devices RS-485 (300–115200 bit/sec) Amount of devices to connect/poll 1 2 254 32 (if device support Modbus RTU) 64 (if device support IEC 60870-5-101) ENCM- X - X - X Power supply voltage 1 – 100–265 V AC or 120–370 V DC 2 – 18–36 V DC Optional features Digital and analog inputs 4 digital inputs («dry contact»); — Built-in GPS/GLONASS-receiver 2 analog inputs 0…20 mA DC or 1 analog input –20…20 mA DC Synchronize clock of meters ENCM-3: A – 1 х RS-485 AT – 1 х RS-485, built-in GPS/GLONASS-receiver A2T-401 – 2 х RS-485, Ethernet 100Base-T, built-in GPS/ GLONASS-receiver, 4 digital inputs, 1 analog input A2T-402 – 2 х RS-485, Ethernet 100Base-T, built-in GPS/ GLONASS-receiver, 4 digital inputs, 2 analog inputs Synchronize polled devices clock Power supply Voltage of power supply 18–36 V DC or universal 120–370 V DC / 100–265 V AC (45–55 Hz) Power consumption Interfaces and optional features ENCM-1: A – 1 х RS-485 AET – 1 х RS-485, Ethernet 100Base-T, built-in GPS/GLONASS-receiver 10 VA Operating conditions and design Operating temperature Housing mounting from −40 to +70 °C plastic, 150х90х45 mm, IP40 35 mm DIN-rail mounting plastic, 150х90х45 (150х90х60) mm, IP40 35 mm DIN-rail mounting Оptions and accessories GSM-3G.3 outdoor GSM antenna on magnetic base (feeder length 3 m) GPS-B3.15, GPS-B3.45 GPS outdoor antenna (feeder length 15 m or 45 m, SMA connector) GPS-BR-mini Compact bracket for mounting GPS antenna. Stainless steel 1,5 mm GPS-BR-300, GPS-BR-500, GPS-BR-1000 Steel bracket for mounting GPS antenna, 300/500/1000 mm 36 37 Оptions and Accessories Activate additional protocols ES61850.enip ES61850.enmv IEC 61850-8-1 support for ENIP-2: MMS-server, publicate/subscribe GOOSE. (for models А3Е4-21, А2Е4x2-21, А2Е4x2FX-21) IEC 61850-8-1 support for ENMV: MMS-server, publicate/subscribe GOOSE. (for models А2Е4) ENIP-2 accessories DIN-BR Bracket for ENIP-2-..-32 for mounting on DIN-rail. Aluminum alloy RM6-BR Bracket for ENIP-2-...-32. Stainless steel 1,5 mm Antennas and brackets GPS-BR-MINI GPS-B3.15 GSM-3G.3 GPS outdoor antenna, feeder length 15 m, SMA connector outdoor GSM antenna on magnetic base, feeder length 3 m, SMA connector Compact bracket for mounting GPS antenna. Stainless steel 1,5 mm GPS-B3.45 GPS outdoor antenna, feeder length 15 m, SMA connector GPS-BR-300 Steel bracket for mounting GPS antenna, 300 mm ENMV-1w accessories To simplified device installation and getting additional opportunities, we offer a number of options and accessories: supporting additional protocols, GSM and GPS antennas, brackets and fasteners. 38 TS-1w TS-SRS additional temperature sensor shield for temperature sensor — to protect temperature sensor from solar radiation, wind and sediments GPS-BR-500 GPS-BR-1000 Steel bracket for mounting GPS antenna, 500 mm Steel bracket for mounting GPS antenna, 1000 mm 39 WARRANTY AND SUPPORT The company's products Engineering Center "Energoservice ", Ltd. has established itself as a reliable device, trouble-free operation which is confirmed by many years of operating experience in industrial enterprises and power facilities. We control quality of used technologies, platforms and components at all stages from development to production. It make possible to provide high level quality of all our products. Warranty for all products is 3 years. Our customers can always get quality technical support on issues related to the use of our products. We offer free technical seminars for introduce with our products and solutions. We participate in exhibitions, provide consulting in the design and operation of our equipment. Use www.enip2.com to get more information about products and solutions. Please contact us if you need more information or you want to request an offer. Engineering Center "Energoservice" [email protected] www.enip2.com 40 All images are presented only as an example. Actual characteristics, such as color and screen forms may differ from what is shown. Specifications and design are subject to change without notice, so ask for confirmation of the information contained in this publication. 42