Download Manual REGULADORES DE FLUJO LUMINOSO CON

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Opto-isolator wikipedia , lookup

Ground (electricity) wikipedia , lookup

Solar micro-inverter wikipedia , lookup

Power inverter wikipedia , lookup

Electromagnetic compatibility wikipedia , lookup

Mercury-arc valve wikipedia , lookup

Portable appliance testing wikipedia , lookup

War of the currents wikipedia , lookup

Electric power system wikipedia , lookup

Islanding wikipedia , lookup

Variable-frequency drive wikipedia , lookup

Electrical substation wikipedia , lookup

Telecommunications engineering wikipedia , lookup

Buck converter wikipedia , lookup

Resistive opto-isolator wikipedia , lookup

Surge protector wikipedia , lookup

Rectifier wikipedia , lookup

Power engineering wikipedia , lookup

Stray voltage wikipedia , lookup

Distribution management system wikipedia , lookup

Voltage regulator wikipedia , lookup

Electrical ballast wikipedia , lookup

Electrification wikipedia , lookup

Rectiverter wikipedia , lookup

Metadyne wikipedia , lookup

Three-phase electric power wikipedia , lookup

LED lamp wikipedia , lookup

Switched-mode power supply wikipedia , lookup

History of electric power transmission wikipedia , lookup

Alternating current wikipedia , lookup

AC adapter wikipedia , lookup

Street light wikipedia , lookup

Voltage optimisation wikipedia , lookup

Mains electricity wikipedia , lookup

Transcript
Manual REGULADORES DE FLUJO
LUMINOSO
CON ESTABILIZACIÓN DE TENSIÓN PARA ALUMBRADO PÚBLICO Y VIAL 1
Manual “REGULADORES DE FLUJO LUMINOSO CON
ESTABILIZACIÓN DE TENSIÓN PARA ALUMBRADO PÚBLICO
Y VIAL”
ÍNDICE
1. SITUACIÓN DE PARTIDA ...................................................................................... 3
2. PRINCIPIO DE FUNCIONAMIENTO DE LOS REGULADORES DE FLUJO
PROPUESTOS ............................................................................................................ 3
3. CARACTERÍSTICAS DE LOS EQUIPOS ............................................................... 4
4. PROVEEDORES SELECCIONADOS ..................................................................... 4
5. SERVICIOS OFRECIDOS ....................................................................................... 4
6. VENTAJAS PARA LOS CLIENTES ....................................................................... 5
7. CRITERIOS DE PRIORIZACIÓN ............................................................................ 5
2
1. STARTING SITUATION
Most cities and some transport routes have lighting levels that, during low-volume off-peak
traffic periods, are excessive for current needs. This is having an extremely negative impact
on the following, among others:
- The environment (light pollution is an increasing problem for birds, air navigation, earth observations, etc.). - Energy consumption. To deal with this situation, IBERDROLA is encouraging the implementation of luminosity
regulators with voltage stabiliser for public and street lighting. 2. OPERATING PRINCIPLE OF THE PROPOSED LUMINOSITY
REGULATORS
They are centralised units installed at the head end of the public and street lighting supply
(next to the electrical panels). They perform two functions:
- They stabilise the voltage supplied to the lights and auxiliary equipment at the normal preset
value.
- They regulate the luminosity of all of the lights connected to each control cabinet, allowing
it to be reduced during pre-determined periods by 50% (lowering the voltage supplied to
the lights by up to 175-195 V).
3. EQUIPMENT FEATURES
IBERDROLA markets static equipment that covers the entire range of public lighting
panels:
3
- 230V single-phase supplies. - 3x230V three-phase supplies without neutral. - Conventional three-phase supplies: 3x400/230V. The power rating for mass-produced equipment generally goes up to 75 kVA, but customdesigned equipment can be manufactured for higher power ratings.
They apply to high pressure mercury vapour or sodium vapour lamps. They cannot be used with metal halide lamps. 4. SELECTED SUPPLIERS
IBERDROLA has selected the following suppliers: - SCORPIO ELEKTRO XXI. - CORPORACIÓN ZIGOR. The customer can choose a brand from the ones mentioned. 5. SERVICES OFFERED
The installation sale price includes:
- The regulator supply.
- Assembly to build the stand and installation for the equipment (including possible civil
engineering required).
- Preventative maintenance for three years, including two annual visits to check that the
units are working properly.
- Three-year warranty, including the cost of repairing damages components, labour and
travelling expenses. 4
The manufacturer (or whoever he/she appoints) will directly invoice for the assembly.
6. ADVANTAGES FOR CUSTOMERS
- Energy saving (up to 25% with high pressure mercury vapour lamps and 40% with high
pressure sodium vapour lamps).
- Installation paid without increase in electricity bill (the monthly cost would be similar to the
saving earned).
- Reduction of lamp and auxiliary equipment replacement cost (longer service life).
- Three-year equipment maintenance without affecting working conditions for the company
in charge of public lighting management.
7. PRIORITISATION CRITERIA
With a public lighting supply, depreciation is usually quicker:
- The greater the installed power.
- When all of the lamps are high pressure sodium vapour.
- In the case of three-phase supplies with 3x400/230 V voltage. - When the subscribed power is more than 15 kW. On the other hand, the depreciation period becomes excessively long, regardless of
the power, when the supply voltage is 3x230 V.
5