Download GENERATOR DC / AC 60 HZ, SPEED = …3600 RPM

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Rectifier wikipedia , lookup

Electric power system wikipedia , lookup

Commutator (electric) wikipedia , lookup

Buck converter wikipedia , lookup

Electric motor wikipedia , lookup

History of electric power transmission wikipedia , lookup

Pulse-width modulation wikipedia , lookup

Islanding wikipedia , lookup

Stray voltage wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Electric machine wikipedia , lookup

Brushless DC electric motor wikipedia , lookup

Power engineering wikipedia , lookup

Power MOSFET wikipedia , lookup

Dynamometer wikipedia , lookup

AC motor wikipedia , lookup

Electrification wikipedia , lookup

Distribution management system wikipedia , lookup

Voltage optimisation wikipedia , lookup

Mains electricity wikipedia , lookup

Induction motor wikipedia , lookup

Brushed DC electric motor wikipedia , lookup

Alternating current wikipedia , lookup

Stepper motor wikipedia , lookup

Variable-frequency drive wikipedia , lookup

Three-phase electric power wikipedia , lookup

Transcript
Setting the Standard in Mobile Power
Instruction Manual for Model
HYDRO – 15-KP 21-3 PHASE GENERATOR
Hydraulic Generator
Manufacturing of: Vehicle Mounted Generators • Hydraulic Generators
P.O. Box 582 • Chester, NY 10918 • 845-469-9151 • Fax: 845-469-7871 • Web Site/E-mail: Www.fabcopower.com
Initial Installation and Start-Up
Be sure you set the hydraulic flow (GPM) to the generator at
Approximately 62.5 HZ or 3750 RPM with NO electrical load
on the generator.
By using this setting you will have approximately 60HZ (cycles) or 3600
RPM when you are running at full rated load.
One way this can be accomplished is by using a Photo Tachometer on
our generator coupling or generator
cooling fan.
A Photo Tachometer is an inexpensive tool that can be purchased at
McMasters, Grainger, Sears or any other electrical supplier.
ADVANTAGES OF USING A FABCO POWER TRI-PHASE GENERATOR
1. MOTORS AND WIRES ARE SMALLER THAN SINGLE PHASE INSTALLATIONS FOR THE SAME HORSE
POWER RATINGS.
2. MOTOR REVERSING ON BOOM AND LADDER TRUCKS WITHOUT USING MULTIPLE
HYDRAULIC LINES. LESS MAINTENANCE AND BREAK DOWNS USING ELECTRIC MOTORS AND
FLEXIBLE CABLES.
3. MATERIALS AND INSTILLATION COSTS ARE MUCH LESS THAN FULLY
HYDRAULICALLY ACTUATED SYSTEMS
SPECIFICATIONS FOR THREE PHASE GENERATORS
KW
8 KW
AMPS L1, L2, L3
23 AMPS
VOLTS LI, L2, L3
208 VOLTS
12 KW
34 AMPS
208 VOLTS
120 VAC L –TO- N
15 KW
42 AMPS
208 VOLTS
120 VAC L -TO- N
INSULATION CLASS
RATED AMB TEMP
POWER FACTOR
AC OUTPUT FREQUENCY
GENERATOR RPM
MOTOR
LI, L2, L3 –TO- NEUTRAL
120 VAC L -TO- N
H
40 C
1.0 TO 80%
60 HZ
3600
PISTON
FLOW RATES AND PRESSURES
8 KW 11.5 GPM AT 2700 PSI
12KW 11.5 GPM AT 3450 PSI AND 21 GPM AT 2250 PSI
15 KW 21 GPM AT 2250 PSI
DIMENSIONS 8, 12, & 15 KW L = 27” W = 9” H = 13”
HYD12KP-21-3
Rev-2-10/7/03-G.Briggs
TECHNICAL INFORMATION AND SPECIFICATIONS
GENERATOR AC 60 HZ, SPEED = 3600 RPM
GENERATOR VOLTAGE…120/208 THREE PHASE (Y) OR THREE
PHASE 120 DELTA
MOTOR STARTING SURGE = 300% OF CONTINUOUS
OUTPUT 15,000-WATTS CONTINUOUS AC
17,000-WATTS PEAK AC
AC AMPS @ 208 VOLT = 34.0 CONTINUOUS AND 40 PEAK
HYDRAULIC MOTOR SPECIFICATIONS
AXIAL PISTON TYPE ……21cc DISPLACEMENT
MOTOR SHAFT DIAMETER…………….ONE INCH
FLOW CONTROL (OPTIONAL)…CARTRIDGE TYPE
RATED FLOW = 21 GPM. ………MAXIMUM PSI = 2400
MOTOR SPEED = 3,600 RPM………MAXIMUM = 4,200 RPM
INLET PORT SIZE = 1 & 1/16 – 12 S.A.E
RETURN PORT SIZE = 1 & 1/16 – 12 S.A.E
CASE DRAIN PORT SIZE = 1 & 1/16 – 12 S.A.E
THREE PHASE (Y) CONNECTED 120/208 60 HZ
L-1, L-2 AND L-3 TO NEUTRAL = 120 VOLTS
NEUTRAL BUSS BAR
L-1
L-2
L-3
L-1 TO L-2 = 208 VOLTS L-2-TO L-3 = 208 VOLTS L-3 TO L-1 = 208 VOLTS
THREE PHASE DELTA
L-1
L-2
120 VOLT 60 HZ
L-3
L-1 TO L-2 = 120 VOLTS L-2 TO L-3 = 120 VOLTS L-3 TO L-1 = 120 VOLTS
FIXED DISPLACEMENT
TYPE GEAR PUMP
5
6
4
7
3
2
1
TYPICAL HYDRAULIC SCHEMATIC
8
9
*
1.
2.
3.
4.
5.
6.
7.
8.
9.
HYDRAULIC PUMP
PRESSURE RELIEF VALVE
CONTROL VALVE
PRIORITY FLOW CONTROL*
GENERATOR HYRAULIC MOTOR
CASE DRAIN LINE**
RETURN LINE FILTER
OIL COOLER
HYDRAULIC FLUID RESERVOIR
Some units may be equipped with integral priority flow control, refer to specific model number.
** External case drain line may be required on some units refer to specific model number.
When external case drain is required it should be unobstructed direct return to reservoir with a minimum I.D. no less
than that of case drain port on generator motor.
FOR SPECIFIC INSTALLATION RECOMMENDATIONS CONSULT FACTORY
FABCO BY-PASS FLOW CONTROL
FABCO PN 572233
NOTE: THIS ASSEMBLY ONLY NEEDED
WITH FIXED DISPLACEMENT TYPE
GEAR PUMP.
TROUBLESHOOTING
THREE PHASE GENERATOR
CAUSES
PROBLEMS
ALTERNATOR EXCITATION
FAILURE
1.
Low Speed
2.
3.
Faulty capacitor
Faulty winding
REMEDIES
1. Check RPM and set at nominal
value.
2. Check and replace.
3. Check that winding resistance is
as shown in the tables.
HIGH NO-LOAD VOLTAGE
1. Speed too high.
1. Check and adjust RPM’s
LOW NO-LOAD VOLTAGE
1. Speed too low.
2. Faulty rotary diodes.
3. Breakdown in windings.
1. Check and adjust RPM’s
2. Check and replace.
3. Check winding resistance, as
per tables.
PROPER NO-LOAD BUT LOW
LOADED VOLTAGE
1. Low loaded speed.
2. Load too large.
1. Check and regulate RPM.
2. Check and change.
3. Check and replace.
3.
Rotary diodes short-circuited
UNSTABLE VOLTAGE
1. Loose contacts.
2. Uneven rotation.
1. Check connections.
2. Check for uniform rotation
speed.
NOISY GENERATOR
1. Broken bearings.
2. Poor couplings.
1. Replace.
2. Check and repair.