* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download Voltage Transducer LV 100-600 VPN = 600 V
Ground loop (electricity) wikipedia , lookup
Mercury-arc valve wikipedia , lookup
Brushed DC electric motor wikipedia , lookup
Transformer wikipedia , lookup
Spark-gap transmitter wikipedia , lookup
Pulse-width modulation wikipedia , lookup
Power inverter wikipedia , lookup
Power engineering wikipedia , lookup
Ground (electricity) wikipedia , lookup
Immunity-aware programming wikipedia , lookup
Stepper motor wikipedia , lookup
Electrical ballast wikipedia , lookup
Resonant inductive coupling wikipedia , lookup
Three-phase electric power wikipedia , lookup
Current source wikipedia , lookup
Schmitt trigger wikipedia , lookup
Electrical substation wikipedia , lookup
History of electric power transmission wikipedia , lookup
Distribution management system wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Power electronics wikipedia , lookup
Power MOSFET wikipedia , lookup
Voltage regulator wikipedia , lookup
Buck converter wikipedia , lookup
Surge protector wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Opto-isolator wikipedia , lookup
Alternating current wikipedia , lookup
Stray voltage wikipedia , lookup
Voltage Transducer LV 100-600 For the electronic measurement of voltages: DC, AC, pulsed..., with galvanic isolation between the primary circuit (high voltage) and the secondary circuit (electronic circuit). VPN = 600 V Electrical data VPN Primary nominal voltage rms VPM Primary voltage, measuring range IPN Primary nominal current rms R Measuring resistance M 600 0 .. ± 900 16.66 RM min RM max with ± 15 V 0210 Ω 0120 Ω ISN K N VC IC @ ± 600 V max @ ± 900 V max Secondary nominal current rms Conversion ratio Supply voltage (± 5 %) Current consumption 50 600 V : 50 mA ± 15 < 32 + IS V V mA mA V mA Accuracy - Dynamic performance data XG εL IO IOT Overall accuracy @ VPN, TA = 25°C ± 0.9 Linearity error < 0.1 Typ Max Offset current @ IP = 0, TA = 25°C ± 0.2 Temperature variation of IO 0°C .. + 70°C ± 0.2 ± 0.3 tr Response time to 90 % of VPN step 90 % % mA mA µs ●● Closed loop (compensated) voltage transducer using Hall effect ●● Isolated plastic case recognized according to UL 94-V0 ●● Primary resistor R1 incorporated within the housing. Advantages ●● ●● ●● ●● ●● ●● ●● Excellent accuracy Very good linearity Low temperature drift Optimized response time Wide frequency bandwidth No insertion losses High immunity to external interference. Applications General data TA TS NP P R 1 RS m Features Ambient operating temperature 0 .. + 70 Ambient storage temperature - 25 .. + 85 Turns ratio 6000 : 2000 Total primary power loss 10 Primary resistance @ TA = 25°C 36 Secondary coil resistance @ TA = 70°C 55 Mass 790 Standards EN 50178: 1997 °C °C W kΩ Ω g ●● AC variable speed drives and servo motor drives ●● Static converters for DC motor drives ●● Uninterruptible Power Supplies (UPS) ●● Power supplies for welding applications. Application domain ●● Industrial. Page 1/3 110413/5 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice www.lem.com Voltage Transducer LV 100-600 Isolation characteristic Vd Vw Rms voltage for AC isolation test, 50 Hz, 1 min Impulse withstand voltage 1.2/50 µs 6 8 kV kV dCp dCI CTI Creepage distance Clearance distance Comparative Tracking Index (group I) Min 55.12 27.9 600 mm mm Applications examples According to EN 50178 and IEC 61010-1 standards and following conditions: ●● Over voltage category OV 3 ●● Pollution degree PD2 ●● Non-uniform field dCp, dCI, Vw EN 50178 IEC 61010-1 Rated insulation voltage Nominal voltage Single insulation 600 V 600 V Reinforced insulation 600 V 600 V Safety This transducer must be used in electric/electronic equipment with respect to applicable standards and safety requirements in accordance with the manufacturer’s operating instructions. Caution, risk of electrical shock When operating the transducer, certain parts of the module can carry hazardous voltage (eg. primary busbar, power supply). Ignoring this warning can lead to injury and/or cause serious damage. This transducer is a build-in device, whose conducting parts must be inaccessible after installation. A protective housing or additional shield could be used. Main supply must be able to be disconnected. Page 2/3 110413/5 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice www.lem.com Dimensions LV 100-600 (in mm) Connection Remarks Mechanical characteristics ●● General tolerance ●● Transducer fastening Recommended fastening torque ●● Connection of primary ●● Connection of secondary ●● Connection of ground Recommended fastening torque ± 0.3 mm 2 holes Ø 6.5 mm, 2 M6 steel screws 5 Nm M5 threaded studs Faston 6.3 x 0.8 mm M5 threaded stud 2.2 Nm ●● IS is positive when VP is applied on terminal +HT. ●● The primary circuit of the transducer must be linked to the connections where the voltage has to be measured. ●● This is a standard model. For different versions (supply voltages, turns ratios, unidirectional measurements...), please contact us. Page 3/3 110413/5 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice www.lem.com