* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download Fixed capacitor bank 12kV spec
Power inverter wikipedia , lookup
Pulse-width modulation wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Ground (electricity) wikipedia , lookup
Power engineering wikipedia , lookup
Current source wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Electrical ballast wikipedia , lookup
Three-phase electric power wikipedia , lookup
History of electric power transmission wikipedia , lookup
Electrical substation wikipedia , lookup
Spark-gap transmitter wikipedia , lookup
Integrating ADC wikipedia , lookup
Oscilloscope history wikipedia , lookup
Power electronics wikipedia , lookup
Opto-isolator wikipedia , lookup
Voltage regulator wikipedia , lookup
Power MOSFET wikipedia , lookup
Surge protector wikipedia , lookup
Distribution management system wikipedia , lookup
Stray voltage wikipedia , lookup
Buck converter wikipedia , lookup
Alternating current wikipedia , lookup
Aluminum electrolytic capacitor wikipedia , lookup
Voltage optimisation wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Specification for Tender 769864581 General Specification for Fixed Capacitor Bank for Electrical Network up to 12KV General presentation of CP214 capacitor bank Standards Technical characteristics Electrical characteristics Operating conditions Factory tests Documents supplied in case of an order Last update : 2017-05-15 -1- Specification for Tender 769864581 Table of contents: 1. General presentation ……………………………………………..……................................. p. 3 2. Standards………………………………………………………………………….………….. p. 3 3. Technical characteristics ………………………………………………………………........ p. 3 4. Electrical characteristics ……………………………………………………….………....... p. 3 4.1 Acceptable overcurrent and overvoltage ………………………………………………......... p. 4 4.2 Design voltage, design power and marking……………………………................................. p. 4 4.3 Composition…………………………………………………………...................................... p. 4 4.4 General layout and single line diagram…………………………………………………….... p. 5 4.5 Enclosures……………………………………………………………………...................... p. 5 4.6 Capacitor units………………………………………………................................................. p. 5 4.7 Reactors…………………………………………………………………………..................... p. 5 4.8 Connections…………………………………………………………………………….......... p. 5 4.9 Quick discharge coils (optional)………………………………… ……………………....... p. 6 5. Operating conditions ……………………………………………………………………....... p. 6 5.1 Internal fault protection …………………………………………………………………….... p. 6 5.2 Additional protections………………………………………………..................................... p. 6 6. Factory tests ……………………………………………………………………………......... p. 6 6.1 For PROPIVAR capacitor units ……………………………………………........................ p. 6 6.2 For CP214 capacitor banks ……………………………………………………..................... p. 7 7. Documents ………………………………………………….................................................... p. 7 Last update : 2017-05-15 -2- Specification for Tender 769864581 1. General presentation CP 214 is a range of MV capacitor banks designed to be used in electrical networks up to 12kV. The capacitor bank is made of unpainted aluminium frame and painted steel panels, which is equipped with PROPIVAR capacitors, HRC fuses and inrush current limiting reactors. The bank is arranged in delta connection and the HRC fuses insure the protection against capacitor internal fault. 2. Standards The CP 214 equipment is designed, manufactured, and tested according to the relevant IEC recommendations. - High voltage capacitors IEC 60871-1 & 2, BS 1650, VDE 0560, C22-2 N° 190-M1985, - Reactors IEC 289 - HRC Fuses IEC 282.1, IEC 787 3. Technical characteristics CP 214 capacitor bank is made of unpainted aluminium frames and painted steel panels (RAL 9002). It is designed for the following installation conditions: - indoor installation, - altitude less than 1000m, - average daily ambient temperature of between -25°C and +35°C, and a maximum of 40°C. The protection degree of the enclosure is IP 23. Available options for the enclosure: - Door with lock for indoor type enclosure, - Outdoor type enclosure (unpainted aluminium panels), - Door with lock for outdoor type enclosure, (to be used with outdoor type cubicle option). 4. Electrical characteristics Last update : 2017-05-15 -3- Specification for Tender 769864581 CP 214 capacitor bank ranges are available for voltage up to 12kV, for 50Hz or 60Hz network. The insulation level of equipment is as follows: Rated voltage (Vdim) (V) Insulation level (kV) 4160 6600 12000 7,2 7,2 12 Power freq. voltage withstand (kVrms) 20 20 28 Impulse voltage withstand (kV peak) 60 60 75 The tolerance on the rated power of the capacitor bank is : 0/+10%, Capacitance variation according to temperature is : -3,5.10-4/°C 4.1 Acceptable overcurrent and overvoltage CP 214 capacitor banks are designed for: - 1,10 x Un overvoltage - 12 hours per day, - 1,15 x Un power frequency overvoltage - 30 minutes per day, - Permanent overcurrent : 1,3 x In. 4.2 Design voltage, design power and marking According to IEC 60871 recommendations, capacitor units or capacitor banks nameplates shall indicate the maximum power and voltage for which it is designed (Qdim & Vdim). Our capacitor units and capacitor banks have nameplates showing these design power and design voltage (Qdim and Vdim). Operating values can be equal or lower than these values (Qn and Vn). The documents supplied with our medium voltage products (price lists, order forms, catalogues, …) provide reactive power values for the most common network voltages. If the required voltage does not appear in the tables, it is possible to make a calculation using the formulae: Qn = (Vn/Vdim)² x Qdim 4.3 Composition Each stage of CP 214 capacitor bank includes the following components: 4.3.1 Basic components: - Painted steel cubicle (RAL 9002), IP23, for indoor installation, - PROPIVAR capacitor units, (1 or 2 units, depending on the rated power of the bank) - Three single-phase inrush current limiting reactors, - Three HRC fuses. 4.3.2 The following items are available as options: - Set of two quick discharge coils Last update : 2017-05-15 -4- Specification for Tender 769864581 4.4 General layout and single line diagram 4.5 Enclosures The capacitor banks enclosure is made of unpainted aluminium frames and painted steel panels. The banks are designed to include up to 2 capacitor units in delta connection. 4.6 Capacitor units The PROPIVAR capacitor units used in CP214 banks have the following characteristics: - All film technology, - Filled with biodegradable dielectric fluid, - Three-phase, delta connected, - Fitted with three epoxy resin bushings, - Fitted with internal discharge resistors (75V / 10min). According to IEC 60871 standard requirements, capacitor units include internal discharge resistors so that the residual voltage is less than 75V within 10 minutes after disconnection. 4.7 Reactors The reactors used are single-phase, dry type, with air core and natural air cooling. The rated current is equal or higher than 1,43 times the capacitor bank nominal current. The inductance value is calculated so that the peak inrush current value is lower than 100 times the nominal current of the capacitor bank, as per IEC recommendation. 4.8 Connections The connection supports are made of porcelain or epoxy resin. Connections are of bare copper bars. Last update : 2017-05-15 -5- Specification for Tender 769864581 4.9 Quick discharge coils (optional) Quick discharge coils allow a very fast discharge time (less than 10 s). Caution : In any case (without or with quick discharge coils), a time delay relay must be used to avoid connection of the capacitor bank within less than 5 minutes after its disconnection, either due to automatic control, protection tripping, voltage outage, … 5. Operating conditions 5.1 Internal fault protection PROPIVAR capacitors have to be protected according to Rectiphase instructions. Only HRC fuses types and ratings recommended by Rectiphase can be used for capacitor protection. 5.2 Additional protections To provide a suitable protection level for the equipment, the capacitor bank feeder must include the following additional protection devices: - Short-circuit protection: recommended setting values : 3 x In / 0,1s, - Overload protection: recommended setting values : 1,4 x In / 10s. Important note: The circuit-breaker used to protect the capacitor bank shall have the suitable rating and must have been specifically designed for capacitor current switching. 6. Factory tests The reference voltage used for testing is the design voltage (Vdim). Test reports will also mention this value which is allways higher or equal to service voltage. Each CP 214 capacitor bank manufactured by Rectiphase pass routine testing before delivery. The factory routine tests are performed according to IEC relevant recommendations and include the following: 6.1 For PROPIVAR capacitor units - capacitance measurement, - loss angle measurement (tg ), - sealing test, - internal discharge resistor value checking, - voltage test between terminals, - voltage test between terminals and container. Last update : 2017-05-15 -6- Specification for Tender 769864581 6.2 For CP214 capacitor banks - phase to phase capacitance measurement, - insulation measurement, - conformity checking. 7. Documents The following documents are part of Rectiphase supply: - three sets of routine test certificates (french / english), - three sets of drawings and diagrams (french / english or french / spanish), - one instruction manual (french / english / spanish). Last update : 2017-05-15 -7-