* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download instructions to tenderers
Electrification wikipedia , lookup
Pulse-width modulation wikipedia , lookup
Three-phase electric power wikipedia , lookup
Electrical ballast wikipedia , lookup
Current source wikipedia , lookup
Electrical substation wikipedia , lookup
Power engineering wikipedia , lookup
Wind turbine wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
History of electric power transmission wikipedia , lookup
Power MOSFET wikipedia , lookup
Power inverter wikipedia , lookup
Intermittent energy source wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Surge protector wikipedia , lookup
Stray voltage wikipedia , lookup
Voltage regulator wikipedia , lookup
Distribution management system wikipedia , lookup
Buck converter wikipedia , lookup
Solar micro-inverter wikipedia , lookup
Power electronics wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Voltage optimisation wikipedia , lookup
Alternating current wikipedia , lookup
Code Specifications DL SUN-WIND SOLAR/WIND ENERGY MODULAR TRAINER – didactic equipment – Modular trainer for the theoretical and practical study of the electrical installations with photovoltaic solar energy and wind energy. It must be composed of: - A photovoltaic inclinable module, 90W, 12V, complete with a cell for measuring the solar irradiation and with a temperature sensor. - A wind turbine (12 Vdc, 160 W) together with a supporting frame 1.5 m long Anemometer and wind direction sensor mounted on relevant support. - A set of modules with a supporting frame composed of a battery control module, 12V, 32A, with battery; a load module including two 12V lamps, dichroic 20W and LED 3W, with independent switches a load module including two mains voltage lamps, dichroic 35W and LED 3W, with independent switches. an electronic regulation module, with LCD screen. a rheostat a module for the measurement of solar irradiation (W/m2), solar panel temperature (°C), current, voltage and power. a module for measuring wind speed and direction. a motor kit for indoor use of the wind turbine. a dc to ac converter module, with modified sinusoidal output at mains voltage. Rated power: 300 W. Aerogen This item shall have Three-blade wind turbine that provides 12 V, 160 W power. Weight 6 kg Rotor diameter 1.17 m Start up Wind Speed 2.7 m/s Maximum Wind Speed 177 Km/h Rated Power 160 watts @ 12.5 m/s wind speed Certifications CSA (certificate 1954979), CE Voltage regulation set point (factory setting): 14.1V Regulator Adjustment Range: 13.6 to 17.0V (approximately) Tower loads Shaft Thrust: 24Kg @ 160 Km/h wind speed (230 N @ 45 m/s) Quantity Anemometer Page 1 of 6 Code Specifications Quantity The Anemometer must include both wind speed and wind direction sensors. The wind speed sensor will be made up with three cups attached to a rotating system and includes a microprocessor that performs measurement and send data through a serial interface. Sensor Type Wind Speed - Wind cups Wind Direction - Wind vane Material Wind Sensor: UV resistant Separated support where anemometer is installed. Dimensions (length x width x height) – 250mm x 276 mm x 146 mm Weight – 0,500 kg Output Serial protocol Battery Control Module This module shall control the battery and shall integrate the following components: set of cables with terminals to connect a 12V battery. 32 A circuit breaker for control the activation/deactivation of the battery. LED indicator diode for battery correctly connected. 4 mm security connectors black/red, for the battery connection. Dc/Ac Inverter Module DC to AC voltage converter module; the AC output will be at the mains voltage. It will include control circuits against the output overload and against the deep discharge of the battery (voltage below 10.5V threshold). The inverter must be internally protected. Characteristics: Input voltage: 10.5 – 16 V Output voltage: 230 V, 50 Hz Rated power: 300 W Action on overload: 600 W Soft Start Function Connectors and Indicators of the Dc/Ac Inverter Module: DC 12V – DC Feed at the indicated voltage. ON - Status: On when the inverter is active. Page 2 of 6 Code Specifications Quantity Low Bat. & Overload – Status: battery low or output overload. MAINS – Output of the mains (230Vac / 127Vac). Module for Load at Network Voltage This module must incorporate a 35W halogen lamp and a 3W LED lamp, working to the voltage mains. Each lamp must incorporate an On/OFF control independent switch. Module for Load at 12VDC This module must incorporate a 20W halogen lamp and a 3W LED lamp, working at 12V. Each lamp must incorporate an On/OFF control independent switch. Measuring Instrument Module (wind part) The module must be made for realizing the measurements of a wind system. It will include a series of instruments, provided with an analog output in proportional voltage compared to the indicated value of the instrument. Aerogen Electrical Data: usable for measure of voltage, current and power provided by wind turbine generator; it must be possible to connect it to Aero generator output, but also use it as DC voltmeter to measure other variables in the laboratory; the unit of measurement must be V for voltage , A for current, W for power. Load or Battery Electrical Data: usable for measure of voltage, current and power flowing through the battery or to the connected load; typically it will be connected between the battery and the charge regulator connector (battery plugs). The measured value will be simply compared to the value indicated on the charge regulator (if available). The unit of measurement must be V for voltage , A for current, W for power. AC Electrical Data: usable for measure of AC voltage, current and power flowing to the AC load, connected at the inverter output. The unit of measurement are V for voltage , A for current, W for power. Wind Sensors Data: the instrument must measure typical environmental quantity that influence a wind turbine output: the wind speed close to the aero generator and the direction of the wind; the signal must be provided by the 5 poles cable; the unit of measurement must be m/s for anemometer and degree for compass. Instruments characteristics: 2 x Voltmeter DC ±65V 2 x Ammeter DC ±20A 2 x Wattmeter autoscale 1 Wind direction 0…360° 1 Wind Speed 0…40m/s 1 x AC Voltmeter 0…265V Page 3 of 6 Code Specifications Quantity 1 x AC Ammeter 0…2A 1 x Wattmeter autoscale Connections of the Measuring Instrument Module: Connector for anemometer and wind direction sensor Power supply connectors of the module, voltage must be between 9V and 30V. Connectors for the measuring of the signals. Connectors for the output power inverter measuring . RS 485 connector for MODBUS RTU communication Measuring Instrument Module (solar part) The module must be made for realizing the measurements of photovoltaic system. It will include a series of instruments, provided with an analog output in proportional voltage compared to the indicated value of the instrument. Solar Panel Electrical Data: usable for measure of voltage, current and power provided by photovoltaic panel to the load directly or to the charge regulator; it will be possible to connect it to PFS output, but also use it as DC voltmeter (with full scale of 32Vdc) to measure other variables in the laboratory; the unit of measurement must be V for voltage , A for current, W for power. Load or Battery Electrical Data: usable for measure of voltage, current and power flowing through the battery or to the connected load; typically it will be connected between the battery and the charge regulator connector (battery plugs). The measured value must be simply compared to the value indicated on the charge regulator (if available). The unit of measurement must be V for voltage , A for current, W for power. AC Electrical Data: usable for measure of AC voltage, current and power flowing to the AC load, connected at the inverter output. The unit of measurement must be V for voltage , A for current, W for power. Solar Panel Sensors Data: the instrument must measure typical environmental quantity that influence a solar panel output: the power of irradiation on the PV module and the temperature of PV cells; the signal must be provided by the 5 poles cable; the unit of measurement must be W/m2 for irradiation and °C for temperature. Instruments characteristics: 2 x Voltmeter DC ±65V 2 x Ammeter DC ±20A 2 x Wattmeter autoscale 1 Irradiation sensor 0..1200W/m2 1 Solar Panel temperature sensor 0..150°C Page 4 of 6 Code Specifications Quantity 1 x AC Voltmeter 0…265V 1 x AC Ammeter 0…2A 1 x Wattmeter autoscale Connections of the Measuring Instrument Module: Connector for irradiation and solar panel temperature sensor. Power supply connectors of the module, voltage must be between 9V and 30V. Connectors for the measuring of the signals. Connectors for the output power inverter measuring . RS 485 connector for MODBUS RTU communication It must be possible to perform the following exercises: Identification of the components Location of the photovoltaic module Measurement of solar irradiation Measurement of the voltage of the photovoltaic module at no load Current voltage graph of the photovoltaic module Measurement of the voltage of the photovoltaic module with overload Regulation and charging of the battery Direct current solar installation Alternating current solar installation Installing and testing wind turbine Installing and testing anemometer Connecting wind turbine and anemometer to trainer Activate the braking action Direct current wind installation Alternating current wind installation Complete system for Solar Complete system for Wind Complete system for Hybrid The trainer must include data acquisition and processing software. The trainer must be complete with connecting leads and experiment manual in English language. Page 5 of 6 Page 6 of 6