Download What is a PDU?
Radio transmitter design wikipedia , lookup
Immunity-aware programming wikipedia , lookup
Surge protector wikipedia , lookup
Standby power wikipedia , lookup
Opto-isolator wikipedia , lookup
Audio power wikipedia , lookup
NEMA connector wikipedia , lookup
Power electronics wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Captain Power and the Soldiers of the Future wikipedia , lookup
PDUS Agenda Introduction to Power Product Overview Sales Tools Pricing (non-discountable) Modified/Custom PDUs Questions www.geistglobal.com © Geist 2012, Confidential & Proprietary Geist Global • Geist founded 1948 • 45 years of executive management experience in plastics & electronics manufacturing • Privately held, 20% employee owned • Worldwide Headquarters in Lincoln, Nebraska, USA • Offices & manufacturing: 14 locations in the USA, 1 in China, and 1 in EU • Customers on 6 continents. • 2 divisions, Data Center and Plastics. DC products are about 65% of global business. www.geistglobal.com © Geist 2012, Confidential & Proprietary Start to Finish Production www.geistglobal.com © Geist 2012, Confidential & Proprietary Quality and Reliability • Product is assembled using lean single piece flow manufacturing methods. • Every unit is Made-To-Order. • All units are 100% tested on-site. • Highest quality components and production methodologies. • Computer controlled testing and tracking methods. • ISTA packaging standards. • Quality management system validated by ISO 9001:2008 Certification. www.geistglobal.com © Geist 2012, Confidential & Proprietary What is a PDU? www.geistglobal.com © Geist 2012, Confidential & Proprietary Electrical Terminology • Amp (or Ampere): The standard measure of electrical current. o Electricity flows through a wire much like a water flowing through an open pipe. The flow of electricity (electric current) is measured in amps. o The Amp draw of a circuit is dependent on the needs of the devices plugged into it, and is limited by the branch circuit protection. • Voltage: The standard measure of electrical potential, and is a fixed value for every circuit. Voltage is measured with respect to a reference point (usually between two conductors of the circuit). o Voltage is analogous to pressure in a water closed pipe. Higher pressures, or higher voltages, allow more energy to flow within a given amount of time. o Standard voltages present in most data centers are 120V and 208V in the USA, and 230V in continental Europe. www.geistglobal.com © Geist 2012, Confidential & Proprietary Electrical Terminology • Volt-Amp: The amount of apparent power in an electrical circuit. o VA is calculated as: Volt-Amps = volts x amps (VA = V x A) • Watt: The measure of the work being performed -or- total power consumed by a system. o Watts are calculated as: Watts = volts x amps x power factor Single Phase (W = V x A x PF) 3 Phase (W = V x A x PF x 1.73) • Power Factor: The ratio of Real Power to Apparent Power. o A power factor of 100% represents perfect efficiency. o Lower values indicate that there is energy loss in the circuit. AMPS … WATTS … the rate of flow of electricity. the power that is used VOLTS … the push (or pressure), not the amount POWER FACTOR… the efficiency www.geistglobal.com © Geist 2012, Confidential & Proprietary What is De-rating? • Continuous Load = 80% Plug Rating Rule The National Electric Code (NEC) requires that the continuous load not exceed 80% of the plug rating. o 15A unit may supply 12A of power o 20A unit may supply 16A of power o 30A unit may supply 24A of power o 60A unit may supply 48A of power • How is Redundancy affected In a traditional 2 feed system where ‘A’ and ‘B’ are independent of each other the system needs account for the potential load if one feed fails. Example: Two 20A PDUs (A & B redundant) are each loaded to 40%, feed ‘A’ fails so the entire load in now transferred to ‘B’, or 80% (16A). www.geistglobal.com © Geist 2012, Confidential & Proprietary Single Phase Power • Single-phase power is like a 1-cylinder diesel engine. • Power is produced once each cycle. • North American power is 60Hz, which is 60 cycles per second. Single Phase www.geistglobal.com © Geist 2012, Confidential & Proprietary 3-Phase Power • A 3-cylinder diesel engine has one cylinder firing with each 120 degree rotation of the crankshaft…so that 3 power pulses are generated for each full cycle. • Like the 3-cylinder diesel engine, a 3phase power feed has 3 power lines that are offset from each other by 120 degrees. Three Phases www.geistglobal.com © Geist 2012, Confidential & Proprietary 3-Phase 4 Wire DELTA Configuration • In a delta configuration there is only one output voltage level available as there is no neutral conductor present. • A 3-phase delta power configuration consists of 4 conductors: o 3 “hot” lines o 1 ground line 3-Phase 208V Delta 208V output is achieved by wiring one “hot” line to another “hot” line (blue arrows) 208V 208V 208V Line 3 Ground www.geistglobal.com © Geist 2012, Confidential & Proprietary 3-Phase 5 Wire WYE Configuration • The neutral line in the circuit is what makes the 3-phase WYE configuration flexible and increasingly popular, as it allows the output of both 120V and 208V from the same PDU without using a transformer or multiple whips. • A 3-phase WYE power configuration consists of 5 conductors: o 3 “hot” lines o 1 ground line o 1 neutral line 3-Phase 120V/208V WYE 120V by wiring any “hot” line to “neutral.” (brown arrows) 120V Line 1 208V 208V Line 2 208V by wiring any “hot” line to another “hot” line. (blue arrows) 120V Neutral Ground 208V 120V Line 3 www.geistglobal.com © Geist 2012, Confidential & Proprietary Plugs and Receptacles • IEC - Popular Globally and on equipment o IEC plugs can output either 125 volts or 250 volts. o The most popular IEC configurations are C13 to C14 (similar to what you see on the back of your computer at home) and C19 to C20. • NEMA - The most popular standard for plugs and receptacles. o Locking configurations, the part begins with an ‘L’. o The next number represents voltage (5 for 125 volt, 6 for 250 volt). o The amperage rating of the plug or receptacle is listed after the dash. o The final character in the part number is a P (for plug) or R (for receptacle). • Examples o L5-20P = 20 Amp, 125 volt twist-lock plug o 5-20P = 20 Amp,125 volt straight-blade plug. o L6-30P = plug inserts into an L6-30R receptacle. www.geistglobal.com © Geist 2012, Confidential & Proprietary www.geistglobal.com © Geist 2012, Confidential & Proprietary www.geistglobal.com © Geist 2012, Confidential & Proprietary Standard Modified Custom • Standard: o All products Made-To-Order o Manufactured in Lincoln, NE o Usually Ship 2 to 5 days ARO • Modified: o Simple changes; Cord length, plug type, wiring configuration o Add/Delete Switch, meter o Lead time 3 to 7 days ARO • Custom: o New Chassis style, design, layout, firmware o Custom units, quantities of 30 or more o Power variations and new UL listing o Lead time 2 to 4 weeks www.geistglobal.com © Geist 2012, Confidential & Proprietary Meter Options • Basic - No Meter • Metered - Local Meter • • o Local current meter units allow for instant reading of PDU current load. o Power Meter option scrolls through Power Factor, Amps, Volts, and Watts. o Great for use in installations where in-depth remote monitoring is not required (single cabinet closet, non-critical equipment, POS stations). Monitored - Local Meter and Remote Monitoring Capabilities o Local current meter units allow for instant reading of PDU current load. o Remote monitoring and alerting to allow for centralized monitoring of many PDUs. o Accessible via any web browser including PDAs and Smart Phones. o Software is built into unit. Starts reading data as soon as power is connected. o Ideal for use in installations with limited or secure access. Switched - Local Meter and Advanced Remote Monitoring Capabilities o Reboot unresponsive equipment without rolling a truck. o Limit access to unused outlets to avoid potential overloading. o Remote monitoring and alerting to allow for centralized monitoring of many PDUs. o Monitor environmental conditions to make sure proper cooling is maintained. o Accessible via any web browser including PDAs and Smart Phones. o SNMP and E-mail notification of threshold breaches. o Software is built into unit. Starts reading data as soon as power is connected. o Ideal for use in installations with limited or secure access. www.geistglobal.com © Geist 2012, Confidential & Proprietary Environmental Control Devices • Features o Graphing and logging capabilities o Many available with POE o Environmental Monitoring built-in o Up to 16 external sensors can be added for expanded monitoring o Many sensor options available • Benefits o Trend data to discover problems before they result in downtime o Remote monitoring and alerting o Ideal for use in installations with limited or secure access o Monitor environmental conditions to make sure proper cooling is maintained o Accessible via any web browser including PDAs and Smart Phones o SNMP and E-mail notification of threshold breaches o Software is built into unit. Starts monitoring data as soon as power is connected www.geistglobal.com © Geist 2012, Confidential & Proprietary Environmental Control Devices • Built-in Temp, Humidity & Dew Point • (2) RJ-12 ports for connection of up to (4) external sensors • 10/100MB Full Duplex Ethernet port • PoE version available, or use standard 6VDC power supply • Logging and graphing of sensor data • Currently supports SNMP v1 and v2c and up to (5) email addresses for alarms www.geistglobal.com © Geist 2012, Confidential & Proprietary Page 20 Environmental Control Sensors www.geistglobal.com © Geist 2012, Confidential & Proprietary Technical Assistance • Dedicated Customer Service Group. Phone calls are answered by a person Mon-Fri 7:30AM-6:00PM CST • Standard product is built to order. Typically ships within 2-5 business days • Cost-effective customization is our specialty. Unmatched lead times (standard and custom) • In-house engineering department. Includes a group of mechanical, electrical, board layout and software specialists Jeff Miller 513.910.6601 [email protected] www.geistglobal.com Grant Young 800.432.3219 [email protected] © Geist 2012, Confidential & Proprietary SALES TOOLS Brochure Quick Reference Guide Plug and Outlet Images Naming Convention - PDUV-MT07-20T-NEMA PDUV-MT07-20T-NEMA All PDU related items begin with PDU PDUV-MT07-20T-NEMA H=(horizontal configuration) V=(vertical configuration) E=(environmental control device) A=(accessory) PDUV-MT07-20T-NEMA BA=(Basic PDU’s) MT=(metered PDU’s) MN =(monitored PDU’s) SW=(switched PDU’s) PDUV-MT07-20T-NEMA 01-99 =(a random differentiator - since there may be more than one 20T-NEMA versions) PDUV-MT07-20T-NEMA 20=(20 amp) 30=(30 amp) 60=(60 amp) PDUV-MT07-20T-NEMA S=(single phase) T=(3 phase) PDUV-MT07-20T-NEMA NEMA=(NEMA plug type) IEC=(IEC plug type) CA=(California plug type) NO=(direct wire) How Much Power Is Needed Website / Configurator The website has been updated. New PDUs will be available in Wrap on the Configurator. Pricing • Competitive within the market place. • Non-discountable • Existing PDUs have now been re-priced with an everyday value price point to appeal to a broader group of potential customers. Modified / Custom PDU Requests • The Process o Fill out the Custom PDU order form. o Submit to Mod quotes. o Crenlo will be the interface with Geist. • The Results o Geist will review to see if the request matches one of their 4000+ standard configurations - if there is not an exact match Geist will recommend a unit that is the closest. o If Geist recommendations doesn’t meet customer needs, Geist will provide quote and lead time for the custom PDU if quantity is appropriate. (Min Qty 30 on custom PDUs) Conclusion •4 Main Categories of PDUs + Environmental Monitoring Devices o Basic o Metered o Monitored o Switched •Modified/Custom PDUs available via modified quote process o Quantity o Time-line (one large order or multiple shipments that make up total quantity) •Technical questions - Get Geist on a CC with customer. •Pricing – Non-discountable. QUESTIONS?