* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download PDS secondo le IEC 61800-n
Audio power wikipedia , lookup
History of electric power transmission wikipedia , lookup
Electric power system wikipedia , lookup
Power inverter wikipedia , lookup
Control theory wikipedia , lookup
Three-phase electric power wikipedia , lookup
Telecommunications engineering wikipedia , lookup
Electromagnetic compatibility wikipedia , lookup
Pulse-width modulation wikipedia , lookup
Induction motor wikipedia , lookup
Resilient control systems wikipedia , lookup
Opto-isolator wikipedia , lookup
Electrification wikipedia , lookup
Sound level meter wikipedia , lookup
Voltage optimisation wikipedia , lookup
Power engineering wikipedia , lookup
Buck converter wikipedia , lookup
Rectiverter wikipedia , lookup
Alternating current wikipedia , lookup
Electrical substation wikipedia , lookup
Control system wikipedia , lookup
Power electronics wikipedia , lookup
Amtrak's 25 Hz traction power system wikipedia , lookup
Brushed DC electric motor wikipedia , lookup
Distributed control system wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Mains electricity wikipedia , lookup
PDS secondo le IEC 61800-n IEC 61800-1 • • • • • • • • • • • System 2.1.1 Power drive system (PDS) (see figure 1) System consisting of power equipment (composed of converter section, d.c. motor and other equipment such as, but not limited to, the feeding section or the field supply), and control equipment (composed of switching control - on/off for example - speed control, current control, firing system, field control, protection, status monitoring, communication, tests, diagnostics, process interface/port, etc.) IEC 61800-2 • • • • • • • • • • 2.1.1 A.C. power drive system (PDS) (see figure 1) System consisting of power equipment (composed of converter section, a.c. motor and other equipment such as, but not limited to the feeding section), and control equipment (composed of switching control – on/off for example –, voltage, frequency, or current control, firing system, protection, status monitoring, communication, tests, diagnostics, process interface/port, etc.). IEC 61800-3 • 3.1 Overview • For the purposes of this document, definitions related to EMC and to relevant phenomena to • be found in IEC 60050(161), in CISPR, and also, the following additional definitions apply. • A power drive system (PDS) consists of a motor and a complete drive module (CDM). ... ... IEC 61800-3 • It does not include the equipment driven by the motor. The CDM consists of a basic drive module • (BDM) and its possible extensions such as the feeding section or some auxiliaries (e.g. • ventilation). The BDM contains converter, control and self-protection functions. Figure 1 • shows the boundary between the PDS and the rest of the installation and/or manufacturing • process. IEC 61800-1, IEC 61800-2 and IEC 61800-4 give details for these definitions. IEC 61800-4 • 3.1.1 A.C. power drive system (PDS) with voltage above • 1 kV (see figure 1) • System consisting of: • power equipment (possible harmonic filters, • input transformer, converter section, • possible output transformer, a.c. motor); • control, protection and auxiliaries. IEC 61800-5-1 • 3.20 • power drive system PDS • system for the speed control of an electric motor, including the CDM and motor but not the driven equipment (see Figure 1) IEC 61800-5-2 • .11 • PDS(SR) • adjustable speed electrical power drive system suitable for use in safety-related applications IEC TR 61800-6 • 2.1 Terms and definitions • For the purpose of this technical report the definitions given in IEC 61800-1, IEC 61800-2 • and IEC 60146-1-1 as well as the following, apply. IEC TR 61800-8 • 3.1 Overview of the system • A power drive system (PDS) consists of a motor and a complete drive module (CDM). It does • not include the equipment driven by the motor. The CDM consists of a basic drive module • (BDM) and its possible extensions such as the feeding section or some auxiliaries (e.g. • ventilation). ...... IEC TS 61800-8 • The BDM contains converter, control and selfprotection functions. Figure 1 • shows the boundary between the PDS and the rest of the installation and/or manufacturing • process. If the PDS has its own dedicated transformer, this transformer is included as a part • of the CDM.