* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download Qualified Electrical Worker Test
Electronic engineering wikipedia , lookup
Voltage optimisation wikipedia , lookup
Electrical substation wikipedia , lookup
Electrical engineering wikipedia , lookup
Stray voltage wikipedia , lookup
Flexible electronics wikipedia , lookup
Electrician wikipedia , lookup
Ground (electricity) wikipedia , lookup
Earthing system wikipedia , lookup
Telecommunications engineering wikipedia , lookup
Mains electricity wikipedia , lookup
Qualified Electrical Worker Test Name _____________________ Crew _____________________ A. Fuse handling equipment, _______________________________ , shall be used to remove or install fuses when the fuse terminals are energized. 1. such as pliers or screwdrivers 2. insulated for circuit voltage 3. or electrical tester probes B. Portable ladders shall ______________________ if they are used where the employee or the ladder could contact exposed energized parts. 1. have nonconductive siderails 2. have no metal parts 3. be a minimum of three feet higher than the electrical panel C. Application of locks and tags. (A) A lock and tag shall be placed on each ___________ _____ used to deenergize circuits and equipment on which work is to be performed, except as provided in paragraphs (b) (2) (iii) (C) and (b) (2) (iii) (E) of this section. The lock shall be attached so as to prevent persons from operating the ___________ _____ unless they resort to undue force or the use of tools. Same answer for both blanks 1. the front of the panel 2. disconnecting means 3. doorway or gate Reenergizing equipment. These requirements shall be met, in the order given, before circuits or equipment are reenergized, even temporarily. D. (b) (2) (v) (A) A qualified person shall _____________________________, as necessary, to verify that all tools, electrical jumpers, shorts, grounds, and other such devices have been removed, so that the circuits and equipment can be safely energized. 1. call out to the nearest staff 2. make all repairs to the equipment 3. conduct tests and visual inspections E. (b) (2) (v) (B) Employees exposed to the hazards associated with reenergizing the circuit or equipment shall ______________________________________. 1. always wear rubber gloves 2. all be qualified electrical workers 3. be warned to stay clear of circuits and equipment F. A qualified person shall use _____________ to test the circuit elements and electrical parts of equipment to which employees will be exposed and equipment parts are deenergized. 1. test equipment 2. two fingers 3. a visual test to see if the equipment is running 05/13/17 BONUS Stored electric energy which might endanger personnel shall be released. Capacitors shall be discharged and high capacitance elements shall be short-circuited and grounded, if the stored electric energy might endanger personnel. NOTE: If the capacitors or associated equipment are handled in meeting this requirement, they shall be treated as energized. List one method of determining if the circuit you are working on has a capacitor? _____________________________________________________________ What does a typical one look like? _____________________________________________________________ How do you discharge a capacitor safely? _____________________________________________________________ 05/13/17