Pre-commissioning Checklist Primary Systems - Substations Substation batteries and chargers physical checks and tests Substation Equipment no. Manufacturer Voltage Rating(s) Serial no. Click here to enter text. Click here to enter text. Click here to enter text. Click here to enter text. Click here to enter text. Click here to enter text. Performed by Service no. Date Click here to enter text. Click here to enter text. Click here to enter a date. 1. Visual inspection Action/check Acceptable criteria Results Check battery charger frame is earthed Correctly earthed Click here to enter text. Check all charger alarms and trip settings Correct Click here to enter text. Check battery cells are not leaking No leaks Click here to enter text. Check battery terminals and connections for signs of rust or corrosion No signs of rust or corrosion Click here to enter text. All connections are correct and tightly terminated. Serviceable Click here to enter text. Initials 2. Functional checks Action/check Acceptable criteria Results Float and boost voltages Check within manufacturer’s recommended settings and record Click here to enter text. Ripple content in DC output According to SDI 535 schedules31 Click here to enter text. Functionality of all control devices and associated electrical circuits Serviceable Click here to enter text. Functionality of all protection devices and associated electrical circuits Serviceable Click here to enter text. Record results Click here to enter text. Batteries tests and checking. Measure: Cell temperature Individual cell impedance Float voltage of each cell Check: All connections, including inter-cell connectors are torqued to specifications FAE 3407 June 2015 SDI 535 Page 1 of 2 Initials 2. Discharge tests: Action/check Acceptable criteria Initials Results Perform discharge test on batteries. Disconnect batteries from the battery charger Record ambient temperature Perform discharge test and record discharge current and time against the cell voltage Discharge time according to battery capability and manufacturer’s recommendations Click here to enter text. 3. Insulation resistance tests (wiring): Action/check Perform insulation resistance test on all control wiring Acceptable criteria Tested using 1kV DC test voltage. Between AC to E > 5.0 MΩ between DC to E > 5.0 MΩ between AC to DC > 10 MΩ on DC bus (if any) > 0.1 MΩ on Pilots (if any) > 0.25 M Initials Results Click here to enter text. 4. Power frequency with stands voltage tests (wiring): Action/check Acceptable criteria Initials Results Perform insulation resistance test on all control wiring: Perform power-frequency withstand voltage of 2kV for 1 min, given as follows: All new wiring installed at site. All wiring not tested for PFWV in factory. All wiring disconnected and removed for transport. Note: If wiring has to be taken off or if electronic devices are in circuits, these circuits shall not be tested). Conducted/tested/ inspected by FAE 3407 June 2015 Service no. No disruptive discharge Witnessed by SDI 535 Service no. Click here to enter text. Reviewed/ reported by Page 2 of 2 Service no.