SECTION 16210 CONTROLLED FREQUENCY MOTOR/GENERATOR SET: 400 HZ, AC 210.01 GENERAL A. Manufacturer Motor generator set shall be as manufactured by the Pillar Company. Substitutions shall require written HGST approval. B. Material Material and parts of the generator set shall be new and unused. Each component shall be of current manufacture from a firm regularly engaged in the production of such equipment. The bidder shall submit with his proposal, a list of three (3) installations of motor-generator sets engineered by the bidder, which have been installed within the past three (3) years and are operating satisfactorily, and which use major components of the same or similar type as the bidder proposed to furnish. 210.02 DESCRIPTION A. The motor shall be specified on the drawing as to load requirements with Class B insulation, 60C rise over 40C ambient, and drip-proof construction. B. Eddy Current Coupling The eddy current coupling shall be air-cooled, salient pole, Class B insulated field, 70C rise over 40C ambient, drip-proof enclosed. C. Generator The generator shall be revolving field type, with damper windings, specified on the drawing as to load requirements and rated for continuous duty, with temperature rise and design in accordance with NEMA and ANSI Standards. (70C rise over 40C for Class B insulation). The exciter shall be integral with the generator and shall have current characteristics to meet the requirements of the generator manufacturer's design. (Static excited type generators or brush less type generators are acceptable). 16210-rev0 16210 - 1 December 2004 SECTION 16210 CONTROLLED FREQUENCY MOTOR/GENERATOR SET: 400 HZ, AC D. Characteristics The motor and eddy current coupling shall drive the generator over the specified operating range without exceeding their nameplate ratings and temperature rises. The couplings shall be capable of operating continuously at any speed in the operating range under full load. The coupling shall be capable of controlling the generator output to +/1 Hz. E. Generator Voltage Regulator A generator voltage regulator shall be provided and controlled from the control panel board. The regulator shall be a voltage sensing static type with no electrolytic capacitors or electronic tubes. The regulator shall be equipped with a control for manual adjustment of the generator voltage level to +/- 10% of generator-rated voltage. The regulator shall provide excitation control over a load range of zero to 110 percent of the generator capacity at rated frequencies. F. Switchgear The control board shall contain the following controls: 1. Motor Circuit Breaker 2. Motor Starter 3. Start-Stop Pushbutton 4. Generator Voltage Regulator 5. Generator Voltmeter 6. Generator Ammeter 7. Generator Voltmeter-Ammeter Switch 8. Generator Frequency Meter 9. Generator Circuit Breaker Note: 16210-rev0 Feeder conduit for 400 Hz to be aluminum. 16210 - 2 December 2004 SECTION 16210 CONTROLLED FREQUENCY MOTOR/GENERATOR SET: 400 HZ, AC 210.03 CONSTRUCTION A. B. C. Coupling 1. The eddy current coupling frame shall be of fabricated steel construction of adequate strength for support of all rotating parts. 2. The eddy current coupling shall have double shaft extension for direct connection to driven and driving equipment. (No bolts or gears shall be used). Bearings 1. The drum and field shall be supported on both ends to eliminate a cantilever load. All bearings shall be arranged for relubrication when required by the maintenance schedule. 2. All bearings shall be rated by AFBMA Standards to have minimum, B-10 life. Field Poles The field poles of the eddy current coupling shall be laminated and either integral with the spider or securely attached to the spider with bolts or “T” tails. There shall be one field coil for each field pole. After the coils are assembled on the pole and the pole assembled on the spider, the coils and pole assembly shall be immersed in insulating varnish and baked dry. This is a final varnish coat in addition to the normal individual coil varnish treatment. D. Drum 1. The coupling drum shall be constructed of a high purity iron with high loss characteristics. 2. The drum shall be cooled by drawing air axially over the back from each end by means of axial blades welded to the periphery of the drum. The coupling frame shall have baffles to confine the air to the surface of the drum and permit exhaust at the middle. The coupling field shall be cooled by drawing air in both ends and exhausting it out the center of the field through the drum. A single air gap shall be used to allow drum expansion away from the field when operating at reduced speeds. The drum shall have a thermal capacity to operate at any speed from 0-97%, when driving a load where the torque varies as the square of the speed. 3. Slip Rings Collector ring systems shall be accessible for each maintenance. 16210-rev0 16210 - 3 December 2004 SECTION 16210 CONTROLLED FREQUENCY MOTOR/GENERATOR SET: 400 HZ, AC 210.04 QUALITY ASSURANCE A. Factory Testing The generator set shall be tested at the facility of the manufacturer. Testing shall include checking of all automatic controls for proper functioning and a load test at the standby rating of the unit for a period of two hours. This testing shall be run at 1.0 pf. During this time, all operating parameters of the motor and generator shall be monitored and recorded every thirty minutes. This test may be witnessed by HGST’s Engineer at his option. B. Job site Testing The generator set shall be tested at the Job site under the supervision of a representative of the manufacturer. Testing shall include checking of all automatic controls for proper functioning, and a load test at the standby rating of the unit for a period of two hours. This testing shall be run at 1.0 pf. The manufacturer of the generator set shall supply dummy load for this test. Following this test, the unit shall pickup the available building load and carry same for a period of one hour. Operating personnel will be instructed in the proper operation and maintenance of the unit. C. Test Data Assemble all test data in booklets for submittal. ***END OF SECTION 16210*** 16210-rev0 16210 - 4 December 2004