Download Full Word texts

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Utility frequency wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Electric motor wikipedia , lookup

Transmission line loudspeaker wikipedia , lookup

Stray voltage wikipedia , lookup

Metadyne wikipedia , lookup

Alternating current wikipedia , lookup

Voltage optimisation wikipedia , lookup

Surge protector wikipedia , lookup

Three-phase electric power wikipedia , lookup

AC motor wikipedia , lookup

Brushed DC electric motor wikipedia , lookup

Induction motor wikipedia , lookup

Stepper motor wikipedia , lookup

Mains electricity wikipedia , lookup

Variable-frequency drive wikipedia , lookup

Transcript
Axial duct fan DZR 25/84 B
Features
Duct sleeve made of galvanised sheet steel, with flanges on both sides.
8-blade impellers made of glass-fibre filled polyamide. Dynamically balanced at two levels,
in accordance with performance level 6.3, DIN ISO 1940, Part 1.
Flange holes in accordance with DIN 24154, page 2, 7/66.
DZR 56/6 B and DZR 56/4 B: Flange holes in accordance with DIN 24145, part 2, 7/90.
To prevent transfer of vibrations onto the duct system: Use flexible couplings, feet and
vibration dampers.
High degree of protection IP 55. Exception EZR/DZR... D IP 54.
Can be fitted in any position.
Motor
Asynchronous motor, speed controllable. Exception: Type EZR 45/6 B, DZR 40/2 B.
Not suitable for ventilating steam-saturated air.
Reversing mode: The volumetric flow is reduced by approx. 35 % with abnormal air flow
direction.
Air flow direction is indicated on the unit with direction of rotation and air flow direction
arrows.
Three-phase AC motor
DZR model series
Rated voltage 400 V, 50 Hz.
Thermal overload protection as a standard feature. Exception: available on request for DZR
25/4 D and pole-changeable axial duct fans.
Potential-free terminal connections, which must be connected to e.g. an MV 25 protective
motor switch or the control circuit of a contactor.
Pole-changeable fans: Ensure overload protection is guaranteed by a motor protection
switch provided by the customer.
Electrical connection
Terminal box with cable sleeves fitted on the outside.
Safety instructions
The fan can be operated only if the protection against accidental contact with the impeller is
guaranteed to be in accordance with DIN EN 13857 for fans with a free inlet.
Special versions
The following special versions are available at extra cost on request:
Special voltages and frequencies.Single-phase motors with thermal contacts or PTC
thermistor, with potential-free terminal connections.Condensation drainage holes.Fans with
enhanced anti-corrosion protection.Impellers made of aluminium.
Information on operation at temperatures occasionally below -20°C available upon request.
If operating with frequency converters, the factory must be consulted.
Feasibility must be checked in each case.
Technical data
Article:
DZR 25/84 B
Air flow volume:
500 m³/h / 1.100 m³/h
Rotating speed:
715 1/min / 1.425 1/min
Impeller type:
axial
Speed controllable:
✔
Reversing capacity:
✔
Type of voltage:
Three-phase AC
Rated voltage:
400 V
Frequency:
50 Hz
Nominal output:
40 W / 80 W
Inom:
0,1 A / 0,3 A
Imax:
0,1 A / 0,3 A
Degree of protection:
IP 55
Insulation class:
B
Pole-changeable:
✔
Number of poles at high speed:
4
Number of poles at low speed:
8
Mains cable:
Installation site:
Installation position:
Material:
Weight:
Nominal size:
5 / 1,5 mm²
Duct
horizontal / vertical
Sheet steel, galvanised
7,3 kg
250 mm
Airstream temperature at nominal
current:
-20 °C up to 60 °C
Airstream temperature at IMax:
-20 °C up to 60 °C
Packing unit:
Range:
EAN:
Article number:
1 piece
C
4012799860402
0086.0040
Manufacturer: MAICO
DZR 25/84 B Axial duct fan