Download 12 VOLT AC/DC POWER SUPPLY

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Standby power wikipedia , lookup

Wireless power transfer wikipedia , lookup

Variable-frequency drive wikipedia , lookup

Pulse-width modulation wikipedia , lookup

Power factor wikipedia , lookup

Ground (electricity) wikipedia , lookup

Three-phase electric power wikipedia , lookup

Stray voltage wikipedia , lookup

Opto-isolator wikipedia , lookup

Islanding wikipedia , lookup

Power inverter wikipedia , lookup

Power over Ethernet wikipedia , lookup

Audio power wikipedia , lookup

Electric power system wikipedia , lookup

Immunity-aware programming wikipedia , lookup

Electrical substation wikipedia , lookup

Electrification wikipedia , lookup

Rectifier wikipedia , lookup

Distribution management system wikipedia , lookup

History of electric power transmission wikipedia , lookup

Amtrak's 25 Hz traction power system wikipedia , lookup

Power electronics wikipedia , lookup

Earthing system wikipedia , lookup

Buck converter wikipedia , lookup

Power engineering wikipedia , lookup

Voltage optimisation wikipedia , lookup

Alternating current wikipedia , lookup

Power supply wikipedia , lookup

Switched-mode power supply wikipedia , lookup

AC adapter wikipedia , lookup

Mains electricity wikipedia , lookup

Transcript
012-02816C
1/95
$1.00
Instruction Sheet
for the PASCO
Model SF-9582
12 VOLT AC/DC POWER SUPPLY
Introduction
scientific
PASCO
PASCO
MODEL SF-9582
AC/DC POWER SUPPLY
ON
6
7
8
5
4
9
3
10
2
11
1
OFF
12
VOLTAGE ADJUST
AC OUTPUT
DC OUTPUT
6 AMPS MAX
➤NOTE: Both AC and DC output circuits are
protected with a thermally activated circuit breaker.
If at any time the power supply fails to come on, or if
it shuts down during operation because of a current
overload, press the RESET button on the front panel.
This will reset the circuit breaker. Of course, you
may have to reduce the voltage or increase the resistance of the load in order to resume operation.
RESET
6 AMPS MAX
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
The PASCO scientific Model SF-9582 12 Volt AC/DC
Power Supply provides AC and DC power in 1 volt increments, from 1 to 12 volts, at up to 6 amps. Since the AC
and DC power are delivered on separate output connectors, they can be utilized simultaneously. Both outputs
are unregulated, and protected from current overload by a
thermal circuit breaker. The DC output is full-wave rectified, but unfiltered.
To Use the Power Supply:
➀ Plug the power cord into a well-grounded 107-128
VAC, 60 Hz or 198-242 VAC, 50 Hz outlet. (See label on rear of unit).
CAUTION:
TO PREVENT THE RISK OF ELECTRIC SHOCK, DO
NOT REMOVE COVER ON UNIT. NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
The lightning flash with arrowhead, within
an equilateral triangle, is intended to alert
the user of the presence of uninsulated
“dangerous voltage” within the product’s
enclosure that may be of sufficient magnitude to constitute a risk of electric shock to
persons.
➁ Connect the appropriate output lines of the power supply to the circuit. (Connecting wires are not provided.)
➂ Set the VOLTAGE ADJUST knob to 1 volt.
➃ Flip the ON/OFF switch on the power supply to ON.
The switch will light to show that the power supply is on.
The exclamation point within an equilateral triangle is intended to alert the
user of the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance.
➄ Set the VOLTAGE ADJUST knob to the desired voltage setting (AC values are in RMS units).
© 1989 PASCO scientific
This instruction sheet edited by: Dave Griffith
better
10101 Foothills Blvd. • P.O. Box 619011 • Roseville, CA 95678-9011 USA
Phone (916) 786-3800 • FAX (916) 786-8905 • email: [email protected]
ways to
teach physics
12 Volt AC/DC Power Supply
012-02816C
Specifications
Equipment Return
AC: 1 to 12 volts (RMS), unregulated, selectable in 1 volt
increments; current up to 6 amps.
Should this product have to be returned to PASCO scientific, for whatever reason, notify PASCO scientific by letter or phone BEFORE returning the product. Upon notification, the return authorization and shipping instructions
will be promptly issued (see reverse side for packing
instructions).
DC: 1 to 12 volts, unregulated, unfiltered, (full wave rectified), selectable in 1 volt increments; current up to 6
amps.
AC and DC outputs are available simultaneously, and
both are protected from current overload by a common 6
amp thermally activated circuit breaker.
➤NOTE: NO EQUIPMENT WILL BE
ACCEPTED FOR RETURN WITHOUT AN
AUTHORIZATION.
Total maximum output current is limited to 6 amps.
When returning equipment for repair, the units must be
packed properly. Carriers will not accept responsibility
for damage caused by improper packing. To be certain
the unit will not be damaged in shipment, observe the following rules:
➤Caution: AC and DC outputs are not independently floating. Cross-connection could result in
internal damage
Other PASCO Power Supplies
➀ The carton must be strong enough for the item shipped.
PASCO scientific offers a variety of rugged, reliable
power supplies. From low-voltage, fixed-output supplies
to a 6 KV DC supply, all PASCO power supplies are easy
to use, ruggedly built, and short circuit protected for long
life in the student lab. For information, check our catalog
or call toll-free 1-800-772-8700.
➁ Make certain there are at least two inches of packing
material between any point on the apparatus and the
inside of the carton.
➂ Make certain that the packing material cannot shift in
the carton, or become compressed, thus letting the instrument come in contact with the edge of the carton.
Parts List*:
Limited Warranty
➤Caution: If repairs are needed, they should be
performed only by experienced personnel.
REFERENCE
PART
MDA 3502
D1
4 AMP SLOW
F1
THERM FUSE
F2
TERMINAL
Power
100R
R1
R100
R2
NT 15050
T1
PASCO scientific warrants this product to be free from
defects in materials and workmanship for a period of one
year from the date of shipment to the customer. PASCO
will repair or replace, at its option, any part of the product
which is deemed to be defective in material or workmanship. This warranty does not cover damage to the product
caused by abuse or improper use. Determination of
whether a product failure is the result of a manufacturing
defect or improper use by the customer shall be made
solely by PASCO scientific. Responsibility for the return
of equipment for warranty repair belongs to the customer.
Equipment must be properly packed to prevent damage
and shipped postage or freight prepaid. (Damage caused
by improper packing of the equipment for return shipment will not be covered by the warranty.) Shipping
costs for returning the equipment after repair will be paid
by PASCO scientific.
*
When ordering parts, be sure to indicate the product number (SF-9582), the part number, and the part description
2
012-02816C
12 Volt AC/DC Power Supply
Schematic:
3
12 Volt AC/DC Power Supply
012-02816C
Technical Support
Feed-Back
Contacting Technical Support
If you have any comments about this product or this
manual please let us know. If you have any suggestions
on alternate experiments or find a problem in the manual
please tell us. PASCO appreciates any customer feedback. Your input helps us evaluate and improve our product.
Before you call the PASCO Technical Support staff it
would be helpful to prepare the following information:
• If your problem is computer/software related, note:
Title and Revision Date of software.
Type of Computer (Make, Model, Speed).
Type of external Cables/Peripherals.
To Reach PASCO
• If your problem is with the PASCO apparatus, note:
For Technical Support call us at 1-800-772-8700 (tollfree within the U.S.) or (916) 786-3800.
Title and Model number (usually listed on the label).
Approximate age of apparatus.
A detailed description of the problem/sequence of
events. (In case you can't call PASCO right away, you
won't lose valuable data.)
If possible, have the apparatus within reach when calling. This makes descriptions of individual parts much
easier.
• If your problem relates to the instruction manual, note:
Part number and Revision (listed by month and year on
the front cover).
Have the manual at hand to discuss your questions.