* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
Download LWW PPT Slide Template Master
Survey
Document related concepts
Transcript
CHAPTER 3 EQUIPMENT OPERATION AND QUALITY CONTROL EXAMINATION REVIEW FOR RADIOGRAPHY Copyright © 2014 Wolters Kluwer Health | Lippincott Williams & Wilkins ARRT Certification Exam: Equipment Operation and Quality Control • Twenty-two questions (11% of the examination) • Three primary sections – Principles of Radiation Physics – Imaging Equipment – Quality Control of Imaging Equipment and Accessories Copyright © 2014 Wolters Kluwer Health | Lippincott Williams & Wilkins Principles of Radiation Physics: X-ray Production • Primary requirements – Source of free electrons • Cathode (− charge) • Heated filament – Focusing of electrons – Acceleration of electrons • Applied kVp – Deceleration of electrons • Rotating tungsten anode (+ charge) • Focusing cup Copyright © 2014 Wolters Kluwer Health | Lippincott Williams & Wilkins Principles of Radiation Physics: X-ray Production—(cont.) • The x-ray tube produces x-rays due to the conversion of high-speed electrons (kinetic energy) into electromagnetic energy (x-ray photons, heat, and light). • X-ray tube efficiency: 1% x-ray production – 99% of energy produced: heat • Two primary atomic interactions occur in the x-ray tube – Bremsstrahlung (85% of radiation produced) – Characteristic (15% of radiation produced) Copyright © 2014 Wolters Kluwer Health | Lippincott Williams & Wilkins Bremsstrahlung Radiation • Projectile electron loses kinetic energy (KE) as it interacts with the nuclear field of a target atom. – Deceleration occurs due to a change in direction of the projectile electron. • Lost KE converted to x-ray photons • Produces varying energy levels and wavelengths of x-ray photons Copyright © 2014 Wolters Kluwer Health | Lippincott Williams & Wilkins Characteristic Radiation • Projectile electron ionizes a k-shell electron of a target atom. • Opening in K-orbit replaced by an outer shell electron (transition) • Characteristic radiation photon released • Produces fixed energy x-ray photons – In a tungsten target, no characteristic radiation will be produced under 69 kVp. Copyright © 2014 Wolters Kluwer Health | Lippincott Williams & Wilkins Fundamental Properties of Electromagnetic Radiation and X-ray Photons • Descriptive or controlling factors – Frequency – Wavelength – Velocity – Energy – Inverse square law Copyright © 2014 Wolters Kluwer Health | Lippincott Williams & Wilkins Characteristics of the X-ray Beam • Descriptive or controlling factors – Quality • Voltage – Quantity • Current – Filtration – Target material – Voltage waveforms/generators Copyright © 2014 Wolters Kluwer Health | Lippincott Williams & Wilkins Primary versus Remnant (Exit) Radiation • Primary radiation • Primary beam • Leakage radiation • Remnant or exit radiation Copyright © 2014 Wolters Kluwer Health | Lippincott Williams & Wilkins Imaging Equipment: Operating Console • Power: (on/off) • kVp control – Provides E for beam penetration • mA control – Controls quantity or intensity of x-ray beam • Timer – Used in conjunction with mA to control the intensity of x-ray beam Copyright © 2014 Wolters Kluwer Health | Lippincott Williams & Wilkins Imaging Equipment: Automatic Exposure Control • Components – Ion chambers or sensors – Density controls • −2 to +2 – Backup timer Copyright © 2014 Wolters Kluwer Health | Lippincott Williams & Wilkins Imaging Equipment: Circuit Components • X-ray tube – Produces x-rays • Transformers – Controls and varies voltage • Incoming current: 60 Hertz AC • Rectifers – Converts AC to DC • Generators – Single phase – Three phase – Each peak = one pulse Copyright © 2014 Wolters Kluwer Health | Lippincott Williams & Wilkins Imaging Equipment: Accessory Devices • Beam restriction devices – Adjustable collimator • Grids – Stationary – Reciprocating (Bucky device) – Aperture diaphragm – Cones and cylinders Copyright © 2014 Wolters Kluwer Health | Lippincott Williams & Wilkins Dedicated X-ray Equipment • Chest: freestanding system for upright imaging • Often incorporates – Automatic vertical tracking • Tomography: focuses on a single plane • Tube and IR move synchronously around a fulcrum – Automatic collimation Copyright © 2014 Wolters Kluwer Health | Lippincott Williams & Wilkins Fluoroscopic Equipment • Used for real-time imaging • Components – X-ray tube • Conventional and digital systems available – Image intensifier • Fixed or mobile (Carm) systems – Display screen/monitor – Automatic brightness control – Recording device(s) Copyright © 2014 Wolters Kluwer Health | Lippincott Williams & Wilkins Digital Imaging • Filmless equipment • Two types – Computed radiography (CR) – Digital radiography (DR) Copyright © 2014 Wolters Kluwer Health | Lippincott Williams & Wilkins Digital Imaging: Computed Radiography (CR) • Components and image acquisition – Reusable imaging plate – Photostimulable phosphor (PSP) • Stores latent image – Laser reader • Stimulates phosphor to release light photons – Monitor • Displays image – Fluorescent light • Erases PSP Copyright © 2014 Wolters Kluwer Health | Lippincott Williams & Wilkins Digital Imaging: Digital Radiography (DR) • Components and image acquisition (two types) – Direct panel DR (amorphous selenium) • Converts x-ray photons directly to an electric signal, sent to a computer – Indirect panel DR (amorphous silicon) • Converts x-ray photons to light to an electric signal, sent to a computer Copyright © 2014 Wolters Kluwer Health | Lippincott Williams & Wilkins Quality Control (QC) of Equipment and Accessory Devices • Beam restriction devices QC tests – X-ray/light field alignment: ±2% of SID – Central ray alignment • Shielding QC tests (aprons, gloves, and gonadal shields) – Visual inspection for tears or cracks – Fluoroscopy check for holes or cracks Copyright © 2014 Wolters Kluwer Health | Lippincott Williams & Wilkins Digital Imaging Quality Control: Artifacts • Types/causes – Debris/dust – Scratches – Incomplete erasure – Ghost images – Fog – Software Copyright © 2014 Wolters Kluwer Health | Lippincott Williams & Wilkins Digital Imaging: Monitor Quality Control • Checked monthly or quarterly • SMPTE (Society of Motion Picture and Television Engineers) test pattern – Tests monitor for • Sharpness • Distortion • Luminance Copyright © 2014 Wolters Kluwer Health | Lippincott Williams & Wilkins